NC Technologies
Filter
Showing all 23 results
| Brand | NC Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | EA-IRMS-iRIS |
| Pricing | Upon Request |
| Brand | NC Technologies |
|---|---|
| Origin | Italy |
| Model | ECS 4010 |
| Analysis Principle | High-Temperature Catalytic Combustion (Dumas Method) |
| Elements Determined | C, H, N, S (optional O) |
| Detection Method | Thermal Conductivity Detection (TCD) |
| Chromatographic Separation | Isothermal GC column (30–110 °C) |
| Automation Level | Fully Automated with Microprocessor Control |
| Sample Introduction | Pneumatic or Zero-Blank Electric Autosampler |
| Isotope Ratio Compatibility | Yes (for δ¹³C, δ¹⁵N, δ³⁴S, etc.) |
| Software | PC-based acquisition and reporting suite with audit trail capability |
| Compliance Support | Designed for GLP/GMP environments |
| Brand | NC Technologies |
|---|---|
| Origin | Italy |
| Model | ECS 4010 |
| Analysis Principle | High-Temperature Catalytic Combustion (Dumas Method) |
| Elements Measured | C, H, N, S (optional O) |
| Detection | Thermal Conductivity Detector (TCD), self-calibrating, reference-gas-free |
| Chromatographic Separation | Isothermal GC column (30–110 °C) |
| Automation Level | Fully automated microprocessor-controlled system with PC integration |
| Sample Introduction | Pneumatic and Zero-Blank electric autosamplers |
| Isotope Ratio Compatibility | Yes (MS-coupling enabled) |
| Compliance Framework | Designed for GLP/GMP environments |
| Brand | NC Technologies |
|---|---|
| Origin | Italy |
| Model | ECS 4010 Classic CHNS-O Elemental Analyzer |
| Detection Principle | Flash Combustion coupled with Gas Chromatographic Separation |
| Elements Analyzed | C, H, N, S, O |
| Detection Range | 200 ppm – 100% |
| Sample Mass | 0.01–100 mg (matrix-dependent) |
| Accuracy | < 0.2% (vs. certified reference materials) |
| Precision | < 0.1% RSD (vs. certified reference materials) |
| Column Temperature Control | 30–110 °C (user-programmable) |
| Oxidation Reactor Temp | 800–1100 °C |
| Reduction Reactor Temp | 600–1100 °C |
| Analysis Time | ~15 min (CHNS), ~3 min (CN only, 2-m column) |
| Detector | Thermal Conductivity Detector (TCD) |
| LOQ | 1–5 µg |
| Auto-samplers | Pneumatic (up to 147 positions), Electronic (32/50/100 positions), Manual |
| Software | EAS CLARITY v.x.x (Windows OS) |
| Gas Requirements | He (99.999%, 3–5 bar), O₂ (99.999%, 3–5 bar), Oil-free Dry Compressed Air |
| Dimensions | 760 × 350 × 700 mm (L×W×H) |
| Power | 230 VAC ±10%, 1–10 A |
| Brand | NC Technologies |
|---|---|
| Origin | Italy |
| Model | ECS 4024 Classic CHNS-O Elemental Analyzer |
| Detection Principle | Flash Combustion coupled with Gas Chromatographic Separation |
| Elements Analyzed | C, H, N, S, O |
| Detection Range | 200 ppm – 100% |
| Sample Mass | 0.01–100 mg (matrix-dependent) |
| Accuracy | < 0.2% (vs. certified reference materials) |
| Precision | < 0.1% RSD (vs. certified reference materials) |
| Combustion Furnace Temperature | 800–1100 °C |
| GC Column Temperature Range | 30–110 °C |
| TCD Limit of Quantification | 1–5 µg |
| Analysis Time | 15 min (CHNS), 3 min (CN, using 2-m GC column) |
| Auto-samplers | Pneumatic (up to 147 positions), Electronic (32/50/100 positions), Manual |
| Software | EAS CLARITY for Windows |
| Gas Requirements | He (99.999%, 3–5 bar), O₂ (99.999%, 3–5 bar), Oil-free dry compressed air |
| Dimensions | 760 × 350 × 700 mm (L×W×H) |
| Power Supply | 230 VAC ±10%, 1–10 A |
| Brand | NC Technologies |
|---|---|
| Origin | Italy |
| Model | ECS 4024 |
| Analysis Principle | High-Temperature Catalytic Combustion (Dumas Method) |
| Elements Determined | C, H, N, S (O optional) |
| Detection Method | Thermal Conductivity Detection (TCD) |
| Gas Separation | Isothermal Chromatographic Column (30–110 °C) |
| Automation Level | Semi-Automatic |
| Software Interface | PC-Connected Dedicated Data Acquisition & Processing Software |
| Isotope Compatibility | Yes (via external MS coupling) |
| Sample Type | Homogeneous Solid or Liquid Organic Samples (Micro-Weighing Compatible) |
| Brand | NC Technologies |
|---|---|
| Origin | Italy |
| Model | ECS 4024 |
| Analysis Principle | High-Temperature Catalytic Combustion (Dumas Method) |
| Elements Determined | C, H, N, S (O optional) |
| Detection Method | Thermal Conductivity Detection (TCD) |
| Chromatographic Separation | Isothermal GC column (30–110 °C) |
| Automation Level | Semi-automatic |
| Software Interface | PC-based dedicated acquisition and reporting software |
| Isotope Compatibility | Compatible with IRMS (Isotope Ratio Mass Spectrometry) coupling |
| Sample Type | Homogeneous solid or liquid organic samples (micro-weighing capable) |
| Regulatory Alignment | Designed for GLP-compliant workflows |
| Brand | NC Technologies |
|---|---|
| Origin | Italy |
| Model | ECS 8020 |
| Analysis Principle | High-Temperature Catalytic Combustion (Dumas Method) |
| Elements Measured | C, H, N, S (O optional) |
| Detection Method | Thermal Conductivity Detection (TCD) |
| Chromatographic Separation | Isothermal GC column (30–110 °C) |
| Automation Level | Fully automated with microprocessor control and PC integration |
| Sample Introduction Options | Manual, Pneumatic, Electric Zero-Blank autosampler |
| Detector Features | Reference-gas-free TCD with auto-calibration |
| Interface Capability | IDMicro EA port for stable isotope ratio mass spectrometry (IRMS) coupling |
| Compliance Context | Designed for GLP/GMP-aligned workflows |
| Brand | NC Technologies |
|---|---|
| Origin | Italy |
| Model | ECS 8020 CHNS-O Organic Elemental Analyzer |
| Measurement Principle | Dumas combustion coupled with gas chromatographic separation and thermal conductivity detection (TCD) |
| Elemental Modes | CHNS, CHN, CN, CNS, O |
| Sample Types | Solid and liquid |
| Sample Weight Range | C/H/N/S: 0.002–20 mg |
| O | 0.002–2 mg |
| Analysis Time | CHN: 5 min |
| CHNS | 10–25 min |
| O | 4 min |
| Accuracy | <0.2% (certified reference materials, purity >99.9%) |
| Precision (RSD) | <0.1% |
| Dual Combustion Furnaces | Max. 1100 °C each |
| Separation Oven Temp. | Up to 110 °C |
| Carrier Gas | Helium |
| Oxygen Delivery | Integrated mass-flow controlled O₂ dosing |
| GC Column Length | 0.8–4 m |
| Detector | High-sensitivity TCD, reference-gas-free operation |
| Autosamplers | Pneumatic (147 positions), electronic (32/50/100 positions), manual |
| Software | EAS Clarity v.x.x with linear/quadratic/cubic calibration, active recalibration, audit trail, GLP-compliant data handling |
| Compliance | Designed for ISO 17025, ASTM D5291, ASTM D7622, USP <28>, EN 15407, and FDA 21 CFR Part 11-ready configurations |
| Brand | NC Technologies |
|---|---|
| Origin | Italy |
| Model | ECS 8020 |
| Analysis Principle | High-Temperature Catalytic Combustion (Dumas Method) |
| Elements Determined | C, H, N, S (O optional) |
| Detection Method | Thermal Conductivity Detection (TCD) |
| Chromatographic Separation | Isothermal GC column (30–110 °C) |
| Automation Level | Fully automated with microprocessor control and PC integration |
| Sample Introduction Options | Manual, Pneumatic, Motorized Zero-Blank Autosampler |
| Detector Features | Reference-gas-free TCD with auto-calibration |
| Software Interface | Dedicated Windows-based acquisition and reporting software with audit trail capability |
| Compliance Support | Designed for GLP/GMP environments |
| Isotope Interface | Integrated IDMicro EA port for coupling to isotope ratio mass spectrometers (IRMS) |
| Power & Gas Management | Standby mode reduces carrier gas consumption (He or Ar), energy use, and idle time |
| Brand | NC Technologies |
|---|---|
| Origin | Italy |
| Model | ECS 8020 |
| Instrument Type | CHNSO Elemental Analyzer |
| Analysis Principle | Dumas Combustion Method |
| Measurable Elements | C, H, N, S, O |
| Sample Throughput | Up to 147 samples (pneumatic autosampler) |
| Analysis Time | C/N: 5 min |
| C/H/N | 8 min |
| C/H/N/S | 13–25 min |
| O | 4 min |
| Measurement Range | C: 0.002–20 mg |
| H | 0.002–5 mg |
| N | 0.002–2 mg |
| S | 0.002–6 mg |
| O | 0.002–2 mg |
| Accuracy | <0.2% (certified reference materials, purity >99.9%) |
| Precision | <0.1% RSD (certified reference materials, purity >99.9%) |
| Detection Sensitivity | <0.3% |
| Furnace Temperature | Dual-zone combustion furnace, up to 1100 °C per zone |
| Separation Oven Temp | Up to 110 °C |
| Carrier Gas | Helium (99.999%), 3–5 bar |
| Oxygen Supply | High-purity O₂ (99.999%), 3–5 bar |
| Auxiliary Gas | Oil-free compressed air |
| GC Column | 0.8–4 m packed capillary column |
| Detector | Self-calibrating high-sensitivity TCD |
| Software | EAS Clarity v5.x with linear, quadratic, and cubic calibration algorithms |
| Sample Form | Solid or liquid |
| Sample Mass | 0.1–500 mg (up to 1000 mg for soil matrices) |
| Sample Containers | High-purity tin or silver crucibles |
| Power Supply | 230 V, 50/60 Hz, 5 A, 1100 W |
| Dimensions | 81 × 50 × 37 cm |
| Weight | 68 kg |
| Brand | NC Technologies |
|---|---|
| Origin | Italy |
| Model | ECS 8022 |
| Measured Elements | C, N |
| Sample Forms | Solid and Liquid |
| Detection Principle | Dumas Combustion Coupled with Gas Chromatography–Thermal Conductivity Detection (GC-TCD) |
| Measurement Range | C/N: 0.002–20 mg |
| Accuracy | <0.2% (vs. certified reference materials, purity >99.9%) |
| Precision | <0.1% RSD (vs. certified reference materials, purity >99.9%) |
| Analysis Time | ~5 min per CN determination |
| Furnace System | Dual-zone high-temperature combustion furnaces (up to 1100 °C each) |
| Separation Column | 3 m GC column |
| Detector | Self-calibrating high-resolution TCD (no reference gas required) |
| Carrier Gas | Ultra-high-purity helium (99.999%, 3–5 bar) |
| Oxidant | Ultra-high-purity oxygen (99.999%, 3–5 bar) |
| Autosamplers | Pneumatic (147-position), Electromechanical (32/50/100-position), Manual |
| Software | EAS Clarity™ with linear/quadratic/cubic calibration, real-time process monitoring, catalyst consumption tracking, and audit-ready data logging |
| Compliance | Designed for GLP/GMP environments |
| Dimensions | 81 × 50 × 37 cm |
| Weight | 68 kg |
| Power | 230 V, 50/60 Hz, 5 A, 1100 W max |
| Brand | NC Technologies |
|---|---|
| Origin | Italy |
| Model | ECS 8024 |
| Measurable Elements | C, N |
| Sample Types | Solid (e.g., soil, sediment, plant tissue) and liquid |
| Detection Principle | Dumas combustion coupled with gas chromatographic separation and thermal conductivity detection (TCD) |
| Measurement Range | C/N: 0.002–20 mg |
| Accuracy | <0.2% (certified reference materials, purity >99.9%) |
| Precision | <0.1% RSD (n=10, CRM) |
| Analysis Time | ~5 min per CN determination |
| Furnace System | Dual-zone high-temperature combustion furnaces (up to 1100 °C each) |
| Separation Column | 3 m GC column |
| Detector | Self-calibrating high-resolution TCD (no reference gas required) |
| Gas Requirements | Helium (99.999%, 3–5 bar), Oxygen (99.999%, 3–5 bar), oil-free compressed air |
| Auto-sampling Options | Pneumatic (147-position), Electronic (32/50/100-position), or manual |
| Software | EAS Clarity v5.x with GLP-compliant audit trail, calibration curve fitting (linear, quadratic, cubic), and method validation tools |
| Compliance | Designed to support ISO 13879, ASTM D5373, EPA Method 9060A, and USP <231> for elemental carbon/nitrogen quantification in environmental matrices |
| Dimensions | 81 × 50 × 37 cm |
| Weight | 68 kg |
| Power | 230 V, 50/60 Hz, 5 A, 1100 W max |
| Brand | NC Technologies |
|---|---|
| Origin | Italy |
| Model | ECS 8024 Soil-Specific CN Elemental Analyzer |
| Measurement Principle | Dumas combustion coupled with gas chromatographic separation |
| Detection | High-resolution thermal conductivity detector (TCD) |
| Sample Throughput | Up to 147 positions (pneumatic/electronic/manual samplers) |
| Analysis Time | ~5 min per CN determination |
| Quantification Range | 0.002–20 mg C and N per sample |
| Accuracy | <0.2% RSD (relative standard deviation) |
| Precision | <0.1% RSD |
| Dual-Furnace System | Left & right furnaces, up to 1100 °C each |
| Separation Oven Temperature | Up to 110 °C |
| Carrier Gas | Helium |
| Oxidant | Automated oxygen dosing |
| GC Column | 3 m packed capillary column |
| Software | EAS Clarity™ with linear/quad/cubic calibration, active recalibration, audit trail, and GLP-compliant data handling |
| Compliance | Designed for ASTM D5373, ISO 13878, USP <281>, and EN 15936 workflows |
| Brand | NC Technologies |
|---|---|
| Origin | Italy |
| Model | ECS 8024 NC SOIL SPECIAL |
| Detection Principle | High-Temperature Catalytic Combustion (Dumas Method) |
| Elements Measured | Total Carbon (TC), Total Nitrogen (TN) |
| Optional Coupling | TIC DISCOVER for Total Inorganic Carbon (TIC) |
| Detector Type | Thermal Conductivity Detector (TCD) |
| Column Temperature Range | 30–110 °C |
| Sample Types | Soils, Fertilizers, Sludges, Sediments, Plant Tissues |
| Automation Level | Fully Automated with Motorized/Pneumatic/Manual Sampler Options |
| Software Control | PC-based with Touchscreen Interface |
| Compliance Ready | Supports GLP/GMP audit trails, ASTM D5373, ISO 10694, USP <281>, EN 15936 |
| Brand | NC Technologies |
|---|---|
| Origin | Italy |
| Model | ECS 8040 |
| Analysis Principle | High-Temperature Catalytic Combustion (Dumas Method) |
| Elements Measured | C, H, N, S (O optional) |
| Detection Method | Thermal Conductivity Detection (TCD) |
| Gas Separation | Isothermal Chromatographic Column (30–110 °C) |
| Automation Level | Fully Automated with Microprocessor Control and PC Integration |
| Sample Introduction Options | Manual, Pneumatic, Motorized Zero-Blank Autosampler |
| Compliance Ready | ASTM D5291, ISO 16968, USP <281>, EN 15104, DIN 51725 |
| Software Features | Real-Time Parameter Monitoring, Catalyst Life Tracking, Leak Detection, Audit Trail Logging (21 CFR Part 11–compliant mode available) |
| Brand | NC Technologies |
|---|---|
| Origin | Italy |
| Model | ECS 8040 CHNS-O Organic Elemental Analyzer |
| Measurement Principle | Dumas combustion coupled with gas chromatographic separation and thermal conductivity detection (TCD) |
| Elemental Range | C, H, N, S, O (0.002–20 mg for C/H/N |
| Accuracy | <0.2% (certified reference materials, purity >99.9%) |
| Precision | <0.1% RSD (certified reference materials, purity >99.9%) |
| Combustion Temperature | up to 1100 °C |
| Reduction Oven Temperature | up to 110 °C |
| Carrier Gas | Helium |
| Oxygen Delivery | Automated dosing with electronic flow control |
| GC Column | 0.8–4 m capillary or packed GC column (dedicated for CO₂, H₂O, N₂, SO₂ separation) |
| Detector | High-sensitivity, reference-free TCD |
| Sample Throughput | Up to 147 positions (pneumatic autosampler), 32/50/100 positions (electronic autosampler), manual option available |
| User Interface | Integrated touchscreen display |
| Software | EAS Clarity™ with linear/quadratic/cubic calibration, active recalibration, audit trail, and GLP-compliant data handling |
| Power Management | Standby mode for reduced He/O₂ consumption and energy use |
| Compliance | Designed to support ASTM D5291, ISO 16968, USP <28>, and FDA 21 CFR Part 11 requirements (when configured with full audit trail and electronic signature modules) |
| Brand | NC Technologies |
|---|---|
| Origin | Italy |
| Model | ECS 8040 |
| Analysis Principle | High-Temperature Catalytic Combustion (Dumas Method) |
| Elements Measured | C, H, N, S, O (O optional) |
| Detection Method | Thermal Conductivity Detection (TCD) |
| Gas Separation | Isothermal Capillary Chromatography (30–110 °C) |
| Automation Level | Fully Automated with Microprocessor Control & PC Integration |
| Sample Introduction Options | Manual, Pneumatic, Motorized Zero-Blank Autosampler |
| Detector Configuration | Dual TCD with Reference-Free Operation |
| Software | Dedicated Windows-Based Acquisition & Quantification Suite with Audit Trail Capability |
| Compliance Framework | Designed for GLP/GMP environments |
| Power Supply | 230 V AC, 50/60 Hz |
| Dimensions (W×D×H) | 700 × 650 × 550 mm |
| Weight | ~75 kg |
| Brand | NC Technologies |
|---|---|
| Origin | Italy |
| Model | ECS 8060 |
| Analysis Method | Dumas Combustion |
| Detected Elements | Nitrogen (N) |
| Protein Calculation | Based on N × Conversion Factor (e.g., 6.25 for food) |
| Analysis Time | 2–8 min per sample |
| Sample Mass Range | 0.1–400 mg (up to 1000 mg for low-carbon samples) |
| Detection Limit (LOQ) | 5 µg N |
| Detector | Self-Calibrating High-Sensitivity TCD |
| Carrier Gas | Helium (99.999%, 3–5 bar) |
| Oxidant Gas | Oxygen (99.999%, 3–5 bar) |
| Auxiliary Gas | Oil-free compressed air |
| Sample Types | Solid and liquid organic matrices |
| Automation | Fully automated oxygen dosing, leak check, flow optimization, catalyst monitoring |
| Interface | Touchscreen HMI |
| Isotope Compatibility | Yes — direct coupling to IRMS systems (e.g., Thermo Fisher, Elementar, Sercon) |
| Compliance | Designed for GLP/GMP environments |
| Brand | NC Technologies |
|---|---|
| Origin | Italy |
| Model | ECS 8070-IRMS-iRIS |
| Sample Throughput | 10–60 min (CO₂ prep), 10 min (δ¹³C via ID Micro), 30–60 min (¹⁴C via PEM iRIS) |
| CO₂ Capture Capacity | 10–100 mg per sample |
| δ¹³C Precision | ±0.083–±0.152 ‰ (1σ, n=6) |
| ¹⁴C Accuracy | <1% pMC |
| Detection Medium | Pure CO₂ gas (≥10 mg C) |
| Compliance | Designed for ISO/IEC 17025-aligned workflows, compatible with GLP/GMP data integrity requirements |
| Brand | NC Technologies |
|---|---|
| Origin | Italy |
| Model | Respirometer 3024B |
| Measurement Principle | Polarographic Oxygen Consumption |
| Oxygen Range | 0–25 % |
| Temperature Range | 0–100 °C |
| Airflow Rate | 10–500 L/h |
| Oxygen Resolution | 0.1 % |
| Temperature Resolution | 0.1 °C |
| Flow Resolution | 0.1 L/h |
| Oxygen Accuracy | ±0.3 % of reading |
| Temperature Accuracy | ±0.5 °C |
| Flow Accuracy | ±1 % of full scale |
| Dimensions | 900 × 750 × 1000 mm |
| Weight | 27 kg |
| Power Supply | 230 V~50 Hz, Max. 2 A |
| Connectivity | Ethernet (RJ45, Cat.5) |
| Gas Supply | High-purity compressed air (3 bar) |
| Software | Respi On Line (embedded), Respi Off Line (data analysis & export to TXT/XLS) |
| Brand | NC Technologies |
|---|---|
| Origin | Italy |
| Model | NCT ECS 4010 |
| Detection Principle | Dumas Combustion Coupled with Gas Chromatographic Separation |
| Elements Analyzed | C, H, N, S, O |
| Sample Mass Range | 0.01–200 mg |
| Accuracy (std. materials) | < 0.2% |
| Precision (std. materials) | < 0.1% |
| LOQ | 1–5 µg |
| Oxidation Furnace Temp. | 800–1100 °C |
| Reduction Furnace Temp. | 600–1100 °C |
| GC Column Temp. Range | 30–110 °C |
| Analysis Time (CHNS) | ~15 min |
| GC Column Length | 2 m |
| Detector | Patented NCT Thermal Conductivity Detector (TCD), Self-Calibrating |
| Autosampler Options | Pneumatic (up to 147 positions), Electronic (32/50/100 positions), Manual |
| Gas Requirements | High-purity He (99.999%, 3–5 bar), O₂ (99.999%, 3–5 bar), Compressed Air |
| Power | 230 VAC ±10%, 1–10 A |
| Dimensions (L×W×H) | 760 × 350 × 700 mm |
| Brand | NC Technologies |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Paeonia IR |
| Price Range | USD 1,400 – 140,000 |