PMM
Filter
Showing 1–30 of 43 results
| Brand | PMM |
|---|---|
| Model | VDH-01 |
| Compliance | IEC 62493 |
| Frequency Range | 20 kHz – 10 MHz |
| Output Impedance | 50 Ω |
| Interface | BNC |
| Weight | 1.7 kg |
| Components | Measurement Probe, Protection Network, Coaxial Cables, Wooden Tripod |
| Optional Accessories | RF Switching Unit, PMM 9010 EMI Receiver |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Other Test Accessories |
| Pricing | Upon Request |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model | PMM 1000 |
| Processor | Motorola DSP56002 & Intel 80C186/187 |
| Input Resolution | 18-bit per channel |
| ADC Interface | IEEE-488 (GPIB) |
| Self-test | On power-up |
| Power Supply | 180–250 VAC / 90–125 VAC, 50–60 Hz |
| Max Power Consumption | 40 W |
| Dimensions | 460 × 448 × 132 mm |
| Weight | 12 kg |
| Operating Temperature | 0–50 °C |
| Storage Temperature | −20–80 °C |
| Storage Humidity | ≤92% RH, non-condensing |
| Software Platform | Windows-based |
| Harmonic Standards Compliance | IEC 61000-3-2, IEC 61000-3-4, IEC 61000-4-7, IEC 555-2 |
| Flicker Standards Compliance | IEC 61000-3-3 (replaces IEC 1000-3-3), IEC 60468 (Amend. 1), IEC 60555-3 (Amend. 1), IEC 60868 (Amend. 1) |
| Voltage Input Range | 90–300 Vrms (flicker: 40–504 Vrms) |
| Current Input Range | 5 mA–16 A (shunt ranges: 0.16 / 0.8 / 4 / 20 A) |
| Voltage Channel Input Impedance | >8 MΩ |
| Current Channel Impedance | <3.03 mΩ (max range) |
| Max Potential Difference | 150 mV |
| Accuracy | Better than ±0.2% for harmonics |
| Anti-aliasing Filter Attenuation | 70 dB |
| Transient Harmonic Smoothing | Low-pass filter, 1° phase shift (1.5 s period) |
| Measurement Modes | Single-shot, time-limited, continuous |
| Data Storage | Ring-buffer architecture retaining last 2.5 minutes of continuous measurement |
| FFT Points | 2048 |
| Frequency Range | 45–65 Hz (extendable to 16–2500 Hz) |
| Flicker Metrics | Pst, Plt, Pmax, P50%, P10%, P3%, P1%, P0.1%, CPF, d(t), dmax, dc |
| Voltage Fluctuation Resolution | ±2% error for d(t) and dmax |
| AC Power Supply Options | TPS 1500 (1-phase, 1.5 kVA), TPS-K10 (3-phase, 10 kVA), TPS-K20 (3-phase, 20 kVA) |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PMM 1008 |
| Quotation | Upon Request |
| Compliance | IEC 61000-4-8, EN 61000-4-8, EU EMC Directive 2014/30/EU (replacing 89/336/EEC), Low Voltage Directive 2014/35/EU (replacing 73/23/EEC) |
| Generator Output | Continuous up to 160 A / Transient up to 1200 A |
| Magnetic Field Levels | Continuous — Class 1 (1 A/m) to Class 5 (100 A/m), Custom |
| Open-Circuit Voltage | ≤4 V |
| Coil Dimensions | 1035 mm × 1035 mm × 35 mm (square loop) |
| Antenna Factor | 0.87 |
| Inductance | ~0.6 µH |
| DC Resistance | 670 µΩ |
| Height Adjustment Range | 0–2000 mm |
| Weight (Net) | 28 kg |
| Dimensions (W×H×D) | 385 × 400 × 215 mm |
| Power Supply | AC 198–264 V, 50/60 Hz |
| Communication Interface | RS-232 / RS-485 (DB9) |
| Safety Features | Thermal cutoff, magnetic overcurrent protection, safety interlock port, fanless design |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model | PMM 1008 |
| Generator Output | 160 A (continuous), 1200 A (transient) |
| Continuous Field Levels | 1–100 A/m (IEC/EN 61000-4-8 Classes 1–5) |
| Transient Field Levels | 300–1000 A/m |
| Coil Dimensions | 1.035 m × 1.035 m × 35 mm |
| Antenna Factor | 0.87 |
| Coil Inductance | ~0.6 µH |
| Coil Resistance | 670 µΩ |
| Generator Dimensions (W×D×H) | 385 × 215 × 400 mm |
| Generator Weight | 28 kg |
| Coil + Trolley + Stand Total Weight | 50 kg |
| Power Supply | 198–264 V AC, 50/60 Hz |
| Interface | RS232/RS485 (DB9) |
| Safety | Interlock-enabled, thermal cutoff, ≤4 Vrms open-circuit voltage |
| Compliance | IEC/EN 61000-4-8, EU Directives 89/336/EEC & 73/23/EEC |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model | PMM 3010 / PMM 3030 |
| Frequency Range | 9 kHz – 1 GHz (3010) / 9 kHz – 3 GHz (3030) |
| Output Level | −107 dBm to +10 dBm |
| Modulation | Internal AM & Pulse Modulation |
| Interface | RS232, USB, User I/O Port |
| Power Supply | Internal Rechargeable Li-ion Battery (PMM 3030-2), AC Adapter |
| Compliance | IEC 61000-4-3, IEC 61000-4-6 |
| Sweep Mode | Yes |
| Programmable | Yes |
| Correction Table Support | Yes |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model | 6000A |
| RF Signal Source | PMM 3010 |
| Power Amplifier Options | PMM 5042 or 7034 |
| Power Meter | PMM 6630 |
| Current Injection Clamp | OIP400 |
| Injection Current Capability | 200 mA, 300 mA, and 400 mA (peak) |
| Software | PIMS (Programmable Immunity Measurement System) |
| Hardware Architecture | Decentralized modular design |
| Instrument Interoperability | Compatible with R&S SMB100 series signal sources and third-party amplifiers/clamps per ISO 11452-4 |
| Compliance | Designed for ISO 11452-4, ISO 10605, SAE J1113/4, and CISPR 25 immunity validation |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model | 6000C |
| Compliance Standards | IEC 61000-4-6, GB/T 17626.6 |
| Calibration Levels | 1 V, 3 V, and 10 V (per IEC 61000-4-6 Annex A) |
| Core Components | PMM 3010 RF Signal Generator, PMM 6000N/5048FE Power Amplifier, M3-16 Coupling/Decoupling Network (CDN), ATT-25W Attenuator, SW-06 Control & Calibration Software, Cab-06 Interconnection Cables |
| Optional Accessories | M-, AF-, S-, and T-type CDNs |
| Amplifier Upgrade Range | 15 W to 10,000 W |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | PMM 6000S/10 |
| Price | Upon Request |
| RF Signal Generator | PMM 3010 |
| Power Amplifier | PMM 6000N (10/15 W, optional 40/80/100 W) |
| Power Meter | PMM 6600 or 6600D, Boonton 4220/4230/9200 |
| Coupling Devices | M3-16 (220 V / 16 A CDN), M3-32, M4-32, M5-32, CDN-S, CDN-F, CDN-T series |
| Probes | F-120-9A Absorbing Probe, F-33 Current Probe, F-203I-23 Absorbing Clamp |
| Attenuators | ATT-25W (6 dB, 25 W), ATT-30W (6 dB, 30 W) |
| Software | SW-06 Immunity Control & Calibration Suite |
| Frequency Range | 100 Hz – 1000 MHz |
| Test Level Range | 1–100 V (0.01 V resolution) |
| Modulation | AM (400 Hz–1 kHz internal/external), Pulse (1 Hz / 200 Hz), Depth: 1–100% |
| Dwell Time | 100 ms – 10 s |
| Calibration Support | Automatic CDN/probe/clamp calibration with traceable correction factors |
| Compliance Standards | IEC/EN 61000-4-6, IEC/EN 61000-4-3, MIL-STD-461G RS103, DO-160 Section 20, ISO 11452-4/2013 |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model | PMM 7000 |
| Frequency Range | 150 kHz – 1 GHz |
| Input A (Conducted) | 150 kHz – 30 MHz, 50 Ω BNC |
| Input B (Radiated) | 30 MHz – 1 GHz, 50 Ω N-type |
| Built-in LISN | 2 × 16 A, 50 Ω/50 µH |
| VSWR | <1.2 (≥10 dB attenuation), <2 (≥0 dB attenuation) |
| Max Input | <127 dBµV (sinusoidal AC) |
| Detectors | Peak, Quasi-Peak, Average (hardware-based) |
| Measurement Uncertainty | ±2 dB (150 kHz–30 MHz), ±2–3 dB (30–300 MHz), ±2–4 dB (300–1000 MHz) |
| Display Units | dBµV, dBµV/m, dBpW |
| IF Bandwidths | 9 kHz / 120 kHz (CISPR-compliant) |
| AM/FM Demodulation Module | Integrated with headphone output |
| Dimensions | 364 × 120 × 376 mm |
| Weight | 5 kg |
| Operating Temperature | 5–40 °C |
| Power Supply | 115/230 VAC ±10%, 50/60 Hz, max. 30 VA |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model | PMM 9010 + 9030 |
| Frequency Range | 10 Hz – 3 GHz |
| Detection Modes | Peak (PK), Quasi-Peak (QP), Average (AVG), RMS |
| Interface | RS-232, Bluetooth (optional), High-Speed Optical Fiber (≥2.5 GB/s) |
| Compliance | CISPR 16-1-1, CISPR 16-2-3, MIL-STD-461G, EN 55032/55035, IEC 61000-4-3 |
| Built-in Signal Generator | 10 Hz – 50 MHz, programmable output |
| Scalar Network Analysis Capability | Yes |
| Real-Time FFT Processing | Yes |
| Internal Memory | High-capacity embedded storage |
| Preselector | Integrated analog preselector with pulse-handling capability |
| Digital LO Architecture | Fully synthesized complex digital IF local oscillator |
| Adaptive RF Attenuation | FPGA-controlled, DSP-driven automatic gain control |
| Click Analyzer | Optional (1-channel internal, 3-channel external) |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model | 9010 |
| Type | CISPR 14-1 Compliant Click Analyzer Module |
| Channel Options | Single-channel or 4-channel (base unit + optional 3-channel expansion) |
| Compliance | Fully compliant with CISPR 14-1:2005, including all clauses E3 and E4 |
| Detection Mode | Quasi-Peak (QP) and Peak, with real-time IF dynamics |
| Data Storage | High-capacity internal memory for full event logging (duration, interval, amplitude, timestamp per click) |
| Analysis Engine | Automated click rate (N) calculation, upper-quartile (UQ) method implementation, exception clause auto-application, “Smart Test” adaptive sequencing |
| Reporting | Fully automated, standards-mandated report generation (PDF/CSV), including all CISPR 14-1 required parameters and metadata |
| Receiver Architecture | Full-digital, integrated quasi-peak receiver with real-time QP value display |
| Software Interface | PC-based control with live waveform/event visualization, multi-level event filtering, and GLP-compliant audit trail support |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model | PMM 9010 |
| Frequency Range | 10 Hz – 30 MHz (expandable to 3 GHz / 6 GHz) |
| Weight | 4 kg (main unit) |
| Power Supply | DC battery-operated (integrated Li-ion) |
| Compliance | Fully compliant with CISPR 16-1-1:2023, EN 55016-1-1, MIL-STD-461G, DO-160G, FCC Part 15/18 |
| Calibration Architecture | Fully digital signal path with built-in RF self-calibration source |
| Detection Modes | Peak, Quasi-Peak, Average, RMS, CISPR-Average, CISPR-RMS |
| RBW Filters | Digital implementation per CISPR 16-1-1 (200 Hz, 9 kHz, 120 kHz, 1 MHz) |
| Software Control | Native Narda STS EMCO software |
| Module Architecture | Pre-calibrated hot-swap functional modules (e.g., click noise analyzer, LISN interface, near-field probes) |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model | 9010 |
| Frequency Range | 10 Hz – 30 MHz (expandable to 2.7 GHz) |
| RF Input | 50 Ω, BNC female |
| Attenuator | 0–35 dB (5 dB steps) |
| Preamp Gain | 10 dB / 20 dB (post-preselector) |
| Max Input (non-destructive) | 137 dBµV (1 W sine), 97 dBµV/MHz (pulse spectral density) |
| Preselector | 7 filters (<9 kHz, 9–150 kHz, 150 kHz–500 kHz, 500 kHz–3 MHz, 3–10 MHz, 10–20 MHz, 20–30 MHz) |
| IF Bandwidths (6 dB) | 10 Hz, 100 Hz, 1 kHz, 10 kHz |
| Detector Modes | Peak, Quasi-Peak, RMS, Average (parallel) |
| Measurement Time | 1 ms – 30 s |
| Display Units | W, V, A, dBm, dBµV, dBµA, dBpW, dBµV/m, dBµA/m |
| Span/Division | 1–100 kHz |
| IF Resolution | 0.1–10 kHz |
| Amplitude Accuracy (S/N > 20 dB) | ±1.0 dB (1–150 kHz), ±0.8 dB (150 kHz–30 MHz) |
| Tracking Generator | 10 Hz–50 MHz, output 60–90 dBµV (0.1 dB steps), accuracy ±0.3 dB (9 kHz–30 MHz) |
| Demodulation | AM/FM |
| Interfaces | RS-232, USB, IEEE-488 (optional), wireless (optional) |
| Operating Temperature | 0–40 °C |
| Power | 12 V DC |
| Dimensions | 235 × 105 × 330 mm |
| Weight | 5 kg |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model | 9010F |
| Frequency Range | 10 Hz to 30 MHz (extendable to 3 GHz / 6 GHz / 18 GHz with optional modules 9030 / 9060 / 9018) |
| Compliance | CISPR 16-1-1, MIL-STD-461, DO-160 |
| Detection Modes | Peak, Quasi-Peak, Average, RMS, RMS-Average, CISPR-Average, APD |
| IF Bandwidths | 200 Hz, 9 kHz, 1 kHz–300 kHz (6 dB) |
| Resolution | 0.1 Hz |
| Frequency Accuracy | <1 ppm |
| Input Impedance | 50 Ω (BNC-f) |
| VSWR | <1.20 @ 10 dB attenuation |
| Max. Input Level | 137 dBµV (CW), 97 dBµV/MHz (pulse spectral density) |
| Built-in Preamp | +20 dB |
| Attenuation | 0–35 dB (5 dB steps) |
| Real-time FFT Sweep Speed | <5 s for CISPR Band A, <20 s for Band B (QPK, 1 s dwell) |
| Operating Temperature | –5 °C to +45 °C |
| Weight | 4.1 kg (with integrated Li-ion battery) |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | PMM 9030 |
| Pricing | Upon Request |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model | PMM 9060 |
| Frequency Range | 30 MHz – 6 GHz |
| Frequency Resolution | 0.1 Hz |
| Measurement Accuracy | < 2 ppm |
| Input Impedance | 50 Ω, N-type female |
| VSWR | < 1.2 @ 0 dB attenuation, < 2.0 @ full attenuation |
| Attenuation Range | 0–55 dB (5 dB steps) |
| Pre-amplifier Gain | 10 dB |
| Max. Input Level (non-damaging) | 137 dBµV (1 W sine), 97 dBµV/MHz (pulse spectral density) |
| Preselector | Low-pass + six band-pass filters covering 30 MHz–1000 MHz and >1000 MHz |
| IF Bandwidths (3 dB) | 3, 10, 30, 100, 300 kHz, 1 MHz |
| IF Bandwidths (6 dB) | 120 kHz (CISPR 16-compliant) |
| Noise Floor | < 2 dBµV (QP, 200 Hz BW, 9–150 kHz), < −2 dBµV (AV, same BW) |
| Detectors | Peak, Quasi-Peak, Average, RMS, Smart Detector |
| Parallel Detection | Supported for Peak, QP, RMS, AV |
| Sweep Time | 1 ms – 30 s (CISPR 16 default) |
| Display Units | dBm, dBµV |
| SNR | > 20 dB |
| Amplitude Probability Distribution (APD) Capability | Yes |
| Tracking Generator Output | 10 Hz – 30 MHz, AM demodulation via PMM 9010 |
| Interface | High-speed optical fiber (≥2.5 Gb/s), RS-232 (service only) |
| Power Supply | 10–15 VDC, 2.5 A |
| Operating Temperature | 0 °C – 40 °C |
| Dimensions | 235 × 105 × 105 mm |
| Weight | 2.0 kg |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model | PMM 9180 |
| Frequency Range | 6–18 GHz |
| Resolution | 100 Hz |
| Reference Frequency Accuracy | < 2 ppm |
| RF Input | 50 Ω, N-type female (SMA compatible) |
| VSWR (10 dB attenuation) | < 2 |
| VSWR (0 dB attenuation) | < 3 |
| Attenuator Range | 0–45 dB (5 dB steps) |
| Preamp Gain | 20 dB |
| Max Input (Sinusoidal AC) | 137 dBμV (1 W, non-damaging) |
| Preselector Bands | 6–9 GHz, 9–12 GHz, 12–15 GHz, 15–18 GHz |
| IF Bandwidths | 3/10/30/100/300 kHz (–6 dB) |
| Displayed Average Noise Level (DANL), RBW = 1 MHz, preselector ON, preamp ON | PK < 8 dBμV (typ. 6 dBμV) |
| DANL, RBW = 1 MHz, preselector ON, preamp OFF | PK < 28 dBμV (typ. 26 dBμV) |
| DANL, RBW = 10 kHz, preselector ON, preamp ON | PK < –12 dBμV (typ. –14 dBμV) |
| Spurious Response | < 20 dBμV |
| Measurement Accuracy (S/N > 20 dB) | ±2.0 dB (6–18 GHz) |
| Interface | High-speed optical fiber |
| Operating Temperature | –5 °C to +45 °C |
| Power Supply | 10–15 VDC, 2.5 A |
| Rechargeable Li-ion Battery | 4 h continuous operation |
| Dimensions | 235 × 105 × 105 mm (L × W × H) |
| Weight | 2.2 kg |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BC-01 |
| Frequency Range | 30–200 MHz |
| Impedance | 50 Ω |
| Polarization | Linear (Vertical/Horizontal) |
| VSWR | ≤2.5:1 (typ. across band) |
| Gain | −2.5 to +1.5 dBi (frequency-dependent) |
| Connector | N-type (female) |
| Max Input Power | 1 kW (CW), 5 kW (peak, pulsed) |
| Operating Temperature | −40 °C to +70 °C |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | C106209 |
| Price Range | USD 1,400 – 7,000 |
| Brand | PMM |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | C4 |
| Price | Upon Request |
| Frequency Range | 1 Hz to 40 GHz |
| Measurement Resolution | 0.01 V/m |
| Electric Field Measurement Range | Determined by Connected E-Field Probe Specifications |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model | PMM CA0010 |
| Frequency Range | 150 kHz – 30 MHz |
| Frequency Accuracy | ±100 Hz |
| Amplitude Range | 20 dBµV – 95 dBµV |
| Amplitude Accuracy | ±0.1 dB |
| Pulse Rise Time | ≥100 µs |
| Pulse Interval | ≥100 µs |
| Time Step Resolution | 10 µs |
| Pulse Repetition Rate | 1 Hz – 500 Hz |
| Repetition Rate Accuracy | ±1 Hz |
| Amplitude Flatness | ≤1.8 dB (150 kHz – 30 MHz) |
| Amplitude Resolution | 0.1 dB |
| Max Input Level | 140 dBµV (2 W) |
| Built-in LISN | Single-phase, 16 A, compliant with CISPR 16-1-2 (150 kHz – 30 MHz) |
| RF Connector | BNC (F) |
| Operating Temperature | −5 °C to +45 °C |
| Dimensions | 235 mm × 105 mm × 335 mm |
| Weight | 4.1 kg |
| Standards Compliance | CISPR 16-1-1, CISPR 16-1-2, CISPR 14-1 |
| Dynamic Range Enhancement | Integrated preselector |
| Signal Generation Capabilities | CW, click, and CISPR pulse signals |
| Software Resolution | 500 µs QP detection, full IF bandwidth display |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model | Click4E |
| Compliance | CISPR 14-1:2005 (incl. Exceptions E3 & E4) |
| Channel Configuration | 1–4 channels (software-activated, hardware-expandable) |
| Measurement Mode | Fully automatic parallel testing or manual single-channel operation |
| Detection Method | Quasi-Peak (QP) detection per CISPR 16-1-1 |
| Data logging | Per-pulse duration, interval, amplitude, and timestamp per IEC/CISPR requirements |
| Report generation | Auto-generated, audit-ready PDF/CSV with full traceability |
| Storage | High-capacity embedded flash memory for ≥10⁶ pulse events |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model | EHP-50B & EHP-50C |
| Frequency Range | 5 Hz – 100 kHz |
| Axes | X/Y/Z triaxial measurement |
| Calibration Data Storage | Built-in EEPROM |
| Interface | Fiber-optic (compatible with PMM 8053A analyzer) |
| Power Supply | Rechargeable battery (up to 7 days in autonomous monitoring mode) |
| Sensor Architecture | Orthogonal magnetic coils + orthogonal parallel-plate capacitors |
| DSP Engine | Integrated digital signal processor with 7 selectable resolution bandwidths (RBW) |
| Spectral Analysis | Real-time FFT-based spectrum display on host unit |
| Compliance | Designed for IEC 61786-1, ICNIRP 2010/2020, IEEE C95.1, and EU Directive 2013/35/EU |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model | EHP-50C |
| Frequency Range | 5 Hz – 100 kHz |
| Axes | Simultaneous X/Y/Z vector measurement |
| Calibration Data Storage | Built-in EEPROM |
| Interface | Optical fiber (compatible with PMM 8053A field meter) |
| Signal Processing | Integrated DSP with selectable 7-band spectral resolution |
| Operating Temperature | −10 °C to +40 °C |
| Physical Form Factor | Compact cubic probe (dimensions not specified) |
| Power Management | Internal rechargeable battery with charging port |
| Status Indication | LED indicators for power/on/off and operational mode |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model | EP-408 |
| Frequency Range | 1 MHz to 40 GHz |
| Electric Field Measurement Range | 0.8 V/m to 800 V/m |
| Measurement Resolution | 0.01 V/m |
| Isotropy (typ.) | ±1 dB @ 200 MHz |
| H-Field Rejection | >20 dB |
| Dynamic Range | >60 dB |
| Overload Protection | >1000 V/m |
| Calibration Memory | Built-in EEPROM |
| Dimensions | 317 mm × Ø52 mm |
| Weight | 90 g |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model | EP 601 |
| Frequency Range | 10 kHz – 9.25 GHz |
| Electric Field Measurement Range | 0.5 – 500 V/m |
| Resolution | 0.01 V/m |
| Overload Protection | > 1000 V/m |
| Dynamic Range | > 60 dB |
| Isotropy | ±0.5 dB |
| Amplitude Flatness | ±0.4 dB |
| Sensor Type | Six Monopole Antennas (Triaxial X/Y/Z) |
| Weight | 23 g |
| Dimensions | 21 mm (sphere diameter) × 16 mm (sensor length) × 53 mm (total length) |
| Operating Temperature | –10 °C to +50 °C |
| Power Supply | Rechargeable Li-ion Battery or External DC Input |
| Temperature Compensation | 0.1 °C per °C |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model | EP-602 |
| Frequency Range | 5 kHz to 9.25 GHz |
| Electric Field Measurement Range | 1.5 V/m to 1500 V/m |
| Measurement Resolution | 0.01 V/m |
| Isotropy (Typical) | ±0.2 dB |
| Frequency Response Flatness (with correction enabled) | ±0.4 dB (50 MHz – 7.5 GHz) |
| Dynamic Range | >60 dB |
| Weight | 22 g |
| Operating Time | Up to 100 h (rechargeable Li-Mn battery) |
| Communication | Duplex optical fiber (up to 60 m) |
| Sensor Type | Spherical symmetric monopole array (6-axis isotropic sensing) |
| Overload Protection | >3000 V/m |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model | EP600 / EP601 |
| Frequency Range | 100 kHz–9.25 GHz (EP600), 10 kHz–9.25 GHz (EP601) |
| Flatness | ±0.4 dB (typ.), ±0.5 dB (typ.) |
| Dynamic Range | 0.14–140 V/m (60 dB), 0.5–500 V/m (60 dB) |
| Linearity | ±0.4 dB (50 MHz, 0.3–100 V/m |
| Resolution | 0.01 V/m |
| Isotropy | ±0.5 dB (±0.3 dB typical) |
| Overload | 300 V/m (EP600), 1000 V/m (EP601) |
| Sampling Rate | 22 samples/s (max), adjustable down to 0.03 samples/s |
| Digital Filter | Adjustable low-pass, 2.3–28 Hz |
| Power Supply | Rechargeable 3 V Li-Mn battery (capacity: mAh not specified) |
| Operating Time | 80 h |
| Charging | Trickle charge, full capacity in 48 h |
| Temperature Sensor Resolution | 0.1 °C |
| Battery Voltage Sensing Resolution | 10 mV |
| Dimensions | ≤53 mm (probe body: 17 mm, sensor core: 17 mm) |
| Weight | 25 g (including 1 m fiber pigtail) |
| Connector | 20-UNF female |
| Fiber Interface | Duplex optical fiber, standard length 10 m (20/40 m optional) |
| PC Interface | USB via fiber-optic transceiver |
| Compliance | CE, RoHS, IEC 61000-4-3 (radiated immunity test support), ISO/IEC 17025 traceable calibration |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model | FR4003 |
| Frequency Range | 9 kHz – 30 MHz |
| Frequency Resolution | 1 Hz |
| Frequency Accuracy | ±1 ppm |
| Internal Attenuation | 0–30 dB (10 dB steps) |
| Preamp Gain | 20 dB |
| Field Strength Limit | 500 V/m (CW, ATT ≥ 20 dB) |
| Noise Floor | 13 dBμV/m (peak), 2 dBμV/m (average) |
| Spurious Response Suppression | < −10 dBμV (ATT = 0 dB, avg, dwell time 10 ms, auto RBW, 50 Ω port) |
| Measurement Accuracy | ±0.8 dB |
| Compliance | CISPR 16-1-1, CISPR 12/16/25, MIL-STD-461, DO-160 |