| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Xe-3 |
| Light Source | Air-Cooled Xenon Arc Lamp (3-lamp configuration) |
| Spectral Range | Full-spectrum solar simulation (290–800 nm) |
| Irradiance Control | SOLAR EYE® broadband or narrowband (340 nm, 420 nm, TUV) |
| Temperature Control | Black panel temperature (42–120 °C), chamber air temperature (ambient to 80 °C) |
| Humidity Control | Relative humidity (10–95% RH, standard) |
| Optional Features | Water spray (single/dual), back-spray, refrigerated cooling unit (-10 to 80 °C operating range with chiller), Window-Q / Window-B/SL / Window-IR / Daylight / Extended UV-Q/B filters |
| Sample Tray Dimensions | 451 mm × 718 mm |
| Max. Sample Capacity | 51 specimens (51 mm × 102 mm) |
| Lamp Life | ~1500 hours |
| Calibration | AUTOCAL®-enabled, CT202 black panel thermometer & CR20 irradiance meter compatible |
| Compliance | ISO 11341, ISO 4892-2, ASTM G155, ASTM D4459, SAE J2527, AATCC TM16, ISO 105-B02, IEC 60068-2-9 |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Xe-3-H |
| Lamp Type | Air-Cooled Xenon Arc Lamp (3-lamp configuration) |
| Lamp Life | 1500 hours |
| Spectral Filtering Options | Daylight, Window Glass (Window-Q, Window-B/SL, Window-IR), Extended UV (UV-Q/B) |
| Irradiance Control | SOLAR EYE® broadband or narrowband (340 nm, 420 nm, TUV) |
| Temperature Control | Black Panel Temperature (42–120 °C), Chamber Air Temperature (ambient to ~80 °C) |
| Humidity Control | Relative Humidity (10–95% RH, standard) |
| Sample Tray Dimensions | 451 mm × 718 mm |
| Max Sample Capacity | 51 specimens (51 mm × 102 mm) |
| Calibration Support | CR20 Irradiance Calibrator, CT202 Black Panel Thermometer |
| Compliance Ready | ASTM G155, ISO 4892-2, SAE J2527, AATCC TM16, ISO 11341, GB/T 16422.2, FDA 21 CFR Part 11 (via optional software audit trail) |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-LAB Xe-3-H |
| Lamp Configuration | Triple independent xenon arc lamps |
| Sample Tray Dimensions | 451 mm × 718 mm (universal 3D sample support) |
| Exposure Area | 3250 cm² |
| Capacity | Up to 55 standard specimen holders |
| External Dimensions | 179.1 cm (H) × 91.4 cm (W) × 94 cm (D) |
| Irradiance Control | SOLAR EYE broadband feedback system with selectable monitoring at 340 nm, 420 nm, or TUV band |
| Humidity Control | Precision electronic relative humidity sensor |
| Temperature Monitoring | Dual-point control — chamber air temperature and black panel/black standard temperature |
| Spectral Output | Full-spectrum xenon arc radiation filtered to meet international daylight simulation requirements |
| Compliance | ASTM G151, ASTM G155, ISO 4892-2, ISO 105-B02/B04/B06, AATCC TM16/TM169, SAE J2412/J2527, IEC 60068-2-5, GB/T 8427–2019, GB/T 14576–2013, and over 50 additional global weathering standards |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-LAB Xe-3-HBS |
| Xenon Lamp Power | 1800 W |
| Lamp Configuration | 3 air-cooled xenon arc lamps |
| Lamp Lifetime | 1500 hours |
| Sample Tray Dimensions | 451 mm × 718 mm |
| Max Sample Capacity | 51 pieces (51 mm × 102 mm) |
| Irradiance Control | SOLAR EYE broadband or narrowband (340 nm, 420 nm, TUV) |
| Temperature Control | Black panel temperature (42–120 °C), chamber air temperature (ambient to 90 °C), optional refrigerated cooling unit |
| Humidity Control | Relative humidity (RH) range: 10–95% RH, standard feature |
| Water Spray Options | Front spray (top-mounted dual nozzles), rear spray (backside wetting), dual-fluid spray (e.g., deionized water + acid rain simulant) |
| Filter Types | Daylight, Window Glass (Window-Q, Window-B/SL, Window-IR), Extended UV-Q/B |
| Compliance Support | ASTM G155, ISO 4892-2, SAE J2527, J2412, ISO 11341, IEC 60068-2-9, GB/T 16422.2, AATCC TM16, ISO 105-B02 |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Xe-3-HBS |
| Lamp Configuration | 3 x air-cooled xenon arc lamps |
| Spectral Range | Full-spectrum solar simulation (290–800 nm) |
| Irradiance Control | SOLAR EYE broadband or narrowband (340 nm, 420 nm, TUV) |
| Black Panel Temperature Range | 42–120 °C |
| Chamber Air Temperature Range | Ambient to 85 °C |
| Relative Humidity Control | 10–95% RH |
| Water Requirements | Deionized or purified water for spray and humidity systems |
| Spray Options | Front spray (top-mounted dual nozzles), optional rear spray (dual-sided wetting), optional secondary liquid spray (e.g., acid rain simulation) |
| Sample Tray Dimensions | 451 mm × 718 mm |
| Max Sample Capacity | 51 × 51 mm × 102 mm specimens |
| Calibration | Patented AUTOCAL system |
| Compliance Support | ASTM G155, ISO 4892-2, SAE J2527, J2412, AATCC TM16, ISO 11341, GB/T 16422.2, FDA 21 CFR Part 11 (via optional software audit trail) |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Xe-3-HC |
| Xenon Lamp Power | 1800 W (3 lamps) |
| Temperature Range | Ambient to 90°C (operational, with refrigeration option) |
| Humidity Range | 20–95% RH |
| Sample Capacity | 55 specimens |
| Sample Tray Dimensions | 45 × 72 cm |
| Sample Tilt Angle | 10° from horizontal |
| Black Panel Temperature Range | 35–110°C (adjustable per sensor) |
| Black Standard Temperature Range | 36–120°C |
| Water Consumption | 0.1 L/min (spray), 44 L/day (humidification) |
| External Dimensions | 78 × 94 × 94 cm |
| Refrigeration Unit Weight | 85 kg |
| Lamp Life Warranty | 1500 hours |
| Compliance | ASTM D2565, D4459, D6695, D7356, ISO 4892-2, ISO 11341, SAE J2527, J2412, GB/T 16422.2, and others |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Xe-3-HDS |
| Lamp Type | Air-Cooled Xenon Arc Lamp (3-lamp configuration) |
| Spectral Range | Full-spectrum solar simulation (290–800 nm) |
| Irradiance Control | SOLAR EYE® broadband or narrowband (340 nm, 420 nm, or TUV 300–400 nm) |
| Black Panel Temperature Range | 42–120 °C |
| Chamber Air Temperature Range | Ambient to 90 °C (with optional refrigerated cooling unit) |
| Relative Humidity Control | 10–95% RH (standard) |
| Sample Tray Dimensions | 451 mm × 718 mm |
| Sample Capacity | Up to 51 specimens (51 mm × 102 mm) |
| Dual Spray System | Standard (deionized water + secondary solution, e.g., acid rain or detergent) |
| Calibration | AUTOCAL® automated calibration system |
| Compliance | ASTM G155, ISO 4892-2, SAE J2527, AATCC TM16, ISO 11341, IEC 60068-2-9 |
| Interface | Touchscreen controller with built-in Ethernet, self-diagnostic alerts, GLP/GMP-ready audit trail logging |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Xe-3-HS |
| Cooling Type | Air-Cooled |
| Lamp Power | 1800 W |
| Spectral Range | Full-Spectrum Solar Simulation (UV, Visible, IR) |
| Humidity Control | Standard RH Regulation (10–95% RH) |
| Water Spray Function | Dual Nozzle Top-Mounted Spray System |
| Sample Tray Dimensions | 45 × 72 cm |
| Max Sample Capacity | 55 specimens (51 × 102 mm each) |
| Black Panel Temperature Range | 35–110 °C |
| Chamber Air Temperature Range | 25–80 °C |
| Compliance | ASTM G155, ISO 4892-2, SAE J2527, AATCC TM16, ISO 11341, IEC 60068-2-9 |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Xe-3-HS |
| Light Source | High-Stability Xenon Arc Lamp |
| Spectral Range | 290–800 nm (full-spectrum solar simulation) |
| Black Standard Temperature Control | 35–110°C |
| Relative Humidity Range | 10–95% RH |
| Water Spray Function | Programmable intermittent rain simulation |
| Lamp Life | ≥1500 hours |
| Compliance | ASTM G155, ISO 4892-2, AATCC TM16, SAE J2527, and other international weathering standards |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Xe-3-HSC |
| Humidity Control | Standard RH control (20–95% RH, ±2% RH accuracy) |
| Temperature Range | 31–120°C (black panel), ambient air temperature independently monitored and controlled |
| Irradiance Control | SOLAR EYE broadband feedback system at 340 nm, 420 nm, or TUV |
| Lamp Configuration | 3 × air-cooled xenon arc lamps (1500 h rated life) |
| Sample Tray Dimensions | 451 mm × 718 mm |
| Max Sample Capacity | 51 × 51 mm × 102 mm specimens |
| Optional Features | Water spray (dual-nozzle, purified water only), refrigerated cooling unit (enables sub-ambient black panel temperatures), dual-fluid spray (e.g., acid rain simulation) |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | Xe-3HSE |
| Xenon Lamp Power | 1800 W × 3 |
| Irradiance Range | 0.55–1.3 W/m²/nm @ 340 nm |
| Light Exposure Cycle | 1–999 h |
| Humidity Range | 20–95% RH |