Q-LAB
Filter
Showing 31–60 of 281 results
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-FOG CRH 1100 |
| Salt Spray Deposition Rate | 0.5–3 mL/h·80 cm² |
| Temperature Range | Ambient to 70 °C |
| Chamber Capacity | 1103 L |
| RH Control | Yes (via air pre-conditioning system) |
| Optional Spray Function | Yes |
| Internal DI Water Requirement | Yes |
| Calibration Interval | Every 6 months (temperature & RH sensors) |
| Compliance | ASTM B117, ISO 9227, ISO 11997, GMW 14872, SAE J2334, Ford CETP, VW PV1210, Renault D17 2025, GB/T 10587, VDA 621-415 |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | CRH 600 |
| Salt Spray Deposition Rate | 0.5–3.0 mL/(h·80 cm²) |
| Temperature Range | Ambient to 70 °C |
| Chamber Capacity | 640 L |
| Humidity Control | Yes (via Air Preconditioner + Fogging Humidification) |
| Compliance | GMW 14872, SAE J2334, ISO 9227, VW 20108, Ford CETP, Renault D17 2020, Volvo STD 5110, GB/T 10125 |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | CRH 600-HSC |
| Category | Cyclic Corrosion Test Chamber (CCT) with RH Control and Spray Functionality |
| Compliance | ASTM B117, ISO 9227, ISO 16701, GMW 14872, SAE J2334, Ford CETP, VW PV1210, Renault D17 2025, Volvo STD 515, Chrysler PF-9802, GB/T 10125 |
| Humidity Control | Programmable RH (30–95% RH, ±2% RH accuracy) via air pre-conditioning system |
| Temperature Range | 10–60 °C (±0.5 °C uniformity) |
| Salt Solution Delivery | Dual-mode — atomized fog (via compressed-air-driven nozzles) and programmable liquid spray (via peristaltic pump, flow-adjustable 0–500 mL/min) |
| Nozzle Maintenance | Automated self-cleaning cycle to prevent crystallization-induced clogging |
| Heating Method | Direct air-heating (non-steam, avoids salt concentration drift) |
| Water Requirement | Deionized water (resistivity ≥5 MΩ·cm) |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Q-FOG CRH1100 |
| Spray Mode | Continuous Atomization |
| Spray Rate | 1–5 L/h per 180 cm² |
| Nozzle Pressure | 0.7–1 kg/cm² |
| De-misting Method | Air-pressurized Exhaust |
| Temperature Range | 20–60 °C |
| Humidity Control | Integrated Air Pre-conditioning System with RH Regulation |
| Optional Spray Module | Programmable High-Volume Liquid Spray |
| Internal Solution Reservoir | 120 L (≥7-day autonomy) |
| Chamber Capacity | 1103 L |
| Sample Capacity | 240 × 75 mm × 150 mm test panels |
| Structural Load Capacity | 544 kg (uniformly distributed) |
| Compliance | ASTM B117, ISO 9227, ISO 11997-1/2, SAE J2334, GMW 14872, Ford CETP, VW PV1210, Renault D17 2025, GB/T 10125, VDA 621-415 |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Q-FOG CRH |
| Spray Mode | Continuous Spray |
| Spray Rate | 1–5 L/h per 180 cm² |
| Nozzle Pressure | 0.7–1 kg/cm² |
| Fog Removal Method | Air-Pressure Exhaust |
| Salt Fog Deposition Rate | 1–2 mL / 80 cm²·h |
| Temperature Range | 20–60 °C |
| Humidity Control | Yes (via Air Pre-Conditioning System) |
| Optional Spray Module | Yes |
| Chamber Volumes | 640 L (CRH600), 1103 L (CRH1100) |
| Compliance | ASTM B117, ISO 9227, GMW 14872, SAE J2334, Ford CETP, VW PV1210, Renault D17 2025, GB/T 10125, ISO 16701 |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | CRH |
| Chamber Capacity | 640 L (CRH600-HSC) / 1103 L (CRH1100-HSC) |
| Temperature Range | Ambient to 50 °C (operational control range) |
| Relative Humidity Control | 30–95% RH (with air pre-conditioning system) |
| Salt Spray Deposition Rate | Adjustable via variable-speed peristaltic pump and regulated air pressure |
| Spray Nozzle Type | Self-cleaning, corrosion-resistant ceramic nozzles |
| Internal Solution Reservoir | 120 L (supports ≥7 days unattended operation) |
| Compliance | ASTM B117, ISO 9227, GMW 14872, SAE J2334, Ford CETP, VW PV1210, Renault D17 2025, GB/T 10125, Prohesion™ protocol |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | CRH |
| Compliance | ASTM B117, ISO 9227, GMW14872, SAE J2334, VW PV1210, Ford CETP, Renault D17 2025, Volvo VCS 1027, Chrysler MSJC307 |
| Humidity Control Range | 10–95% RH (programmable) |
| Temperature Range | Ambient +10°C to 50°C |
| Spray System | Air-saturated compressed air + corrosion solution (NaCl, CuCl₂, acetic acid, etc.) |
| Preconditioned Air System | Integrated air pre-conditioner for precise RH ramping |
| Programmable Spray Option | Yes |
| Controller | Microprocessor-based with dual 80-character LCD interface |
| Built-in Test Cycles | ASTM B117, Prohesion™, CCT-1/CCT-IV, GMW14872, SAE J2334, and custom multi-step cycles |
| Data Logging | Time-stamped cycle step tracking, event history, audit trail capability |
| Software Interface | Q-FOG® Control Software (optional PC connectivity) |
| Construction | Fiberglass-reinforced polymer (FRP) chamber body, corrosion-resistant stainless steel hardware |
| Safety Features | Over-temperature protection, low-level solution alarm, door interlock, leak detection |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Q-FOG CRH |
| Temperature Range | 20–60 °C (spray/soak), 20–70 °C (dry), 20–60 °C (RH) |
| Humidity Control | Fully adjustable relative humidity (RH), 10–95% RH (CRH-specific capability) |
| Internal Solution Reservoir | 120 L |
| Chamber Capacity | 640 L (CRH-600) or 1103 L (CRH-1100) |
| Sample Capacity | 160 plates (75 × 150 mm) or 240 plates (75 × 150 mm) |
| Water Purity Requirement | <8 ppm TDS, resistivity >50 kΩ·cm |
| Compressed Air | 4–10 bar (60–150 psi), max. 1.7 L/s (3.5 CFM) |
| Power Supply | 208–230 V, 50/60 Hz, up to 38 A |
| Weight (dry) | 333 kg (CRH-600), 378 kg (CRH-1100) |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Q-FOG CRH |
| Spray Method | Dual-mode (Atomized Salt Fog + Programmable Spray) |
| Nozzle Pressure | 0.7–1.4 bar |
| Salt Deposit Rate | 1.0–2.0 mL / 80 cm² / h |
| Temperature Range | 35–70 °C |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-FOG CRH |
| Chamber Capacity | 640 L (CRH600-HSC) / 1103 L (CRH1100-HSC) |
| Temperature Range | Ambient to 70 °C (operational range per test standard) |
| Relative Humidity Control | 30–95% RH (with air pre-conditioning system) |
| Salt Spray Deposition Rate | Adjustable via precision peristaltic pump and compressed air regulation |
| Spray Nozzle Type | Corrosion-resistant, self-cleaning atomizing nozzles |
| Optional Features | Integrated spray module (high-volume liquid delivery), programmable dry/wet/humidity/cycle sequences |
| Compliance | Designed to meet ASTM B117, ISO 9227, ISO 16701, GMW 14872, SAE J2334, Ford CETP, VW PV1210, Renault D17 2027, GB/T 10587, and other automotive & industrial cyclic corrosion standards |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | CRH-600 |
| Temperature Range | 20–60 °C (spray/soak), 20–70 °C (dry), 20–60 °C (RH) |
| Internal Chamber Volume | 640 L (incl. lid) |
| Salt Solution Reservoir | 120 L |
| Sample Capacity | 160 × 75 mm × 150 mm panels |
| RH Control Range | Fully adjustable 10–95% RH (CRH model only) |
| Compressed Air Requirement | 4–10 bar, ≤1.7 L/s |
| Deionized Water Specification | <8 ppm TDS, >50 kΩ·cm resistivity |
| Power Supply | 230 V ±10%, 50/60 Hz, 32 A single-phase |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Q-FOG CRH1100 |
| Spray Mode | Continuous Atomization |
| Fog Output | 1–5 L/h per 180 cm² |
| Nozzle Pressure | 0.7–1.0 kg/cm² |
| De-fogging Method | Air-pressurized Exhaust |
| Salt Fog Deposition Rate | 1–2 mL per 80 cm²·h |
| Temperature Range | 20–60 °C |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | CRH1100 |
| Chamber Capacity | 1103 L |
| Salt Spray Deposition Rate | Adjustable via precision peristaltic pump and regulated air pressure |
| Temperature Range | 10–70 °C (operational), with rapid thermal transition capability |
| Relative Humidity Control | 10–95% RH (via integrated air pre-conditioning system) |
| Spray Function | Optional high-flow liquid spray module with user-adjustable duration and flow rate |
| Internal Water Reservoir | 120 L deionized water tank with particulate filtration and low-level alarm |
| Compliance | Designed to meet GMW 14872, SAE J2334, ISO 9227, ISO 11997, ASTM B117, ASTM G85 Annex A5 (Prohesion), VW PV1210, Ford CETP, Renault D17 2025, GB/T 2423.17, GB/T 2423.36 |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-FOG CRH1100 |
| Chamber Capacity | 1103 L |
| Temperature Range | Ambient +10°C to 50°C (operational, adjustable per cycle phase) |
| Relative Humidity Control Range | 10% to 95% RH (±2% RH accuracy, typical) |
| Salt Fog Deposition Rate | 1.0–2.0 mL/80 cm²/h (adjustable via variable-speed peristaltic pump and regulated air pressure) |
| Spray Nozzle Type | Self-cleaning, corrosion-resistant ceramic nozzle array |
| Preconditioned Air System | Integrated dual-stage air pre-conditioning module for precise RH ramping and stabilization |
| Optional Features | Programmable rinse/spray module, internal LED lighting, viewing window, DI water requirement, built-in 120 L solution reservoir with level sensor and particulate filtration |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-FOG CRH600 |
| Spray Mode | Continuous Atomization |
| Spray Rate | 1–5 L/h per 180 cm² |
| Nozzle Pressure | 0.7–1 kg/cm² |
| Fog Removal Method | Air-Driven Mechanical Exhaust |
| Salt Deposit Rate | 1–2 mL / 80 cm²·h |
| Temperature Range | 20–60 °C |
| Humidity Control | Integrated Preconditioned Air System with Adjustable RH (20–95% RH, typical operating range) |
| Chamber Volume | 640 L |
| Compliance | ASTM B117, ISO 9227, ISO 11997-1/2, GMW 14872, SAE J2334, Ford CETP, VW PV1210, Volvo VCS 1027,000, Renault D17 2020, GB/T 10125 |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-FOG CRH600 |
| Spray Mode | Continuous Atomization |
| Spray Rate | 1–5 L/h per 180 cm² |
| Nozzle Pressure | 0.7–1 kg/cm² |
| Fog Removal Method | Air-Driven Exhaust |
| Salt Fog Deposition Rate | 1–2 mL / 80 cm²·h |
| Temperature Range | 10–80 °C |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-FOG CRH600 |
| Salt Fog Deposition Rate | Adjustable and Calibratable per ASTM B117 & ISO 9227 |
| Temperature Range | 10°C to 70°C (operational, with ±0.5°C uniformity) |
| Humidity Control | 10–99% RH, programmable via integrated air pre-conditioning system |
| Cycle Programming | Multi-step sequences including salt spray, dry-off, high-humidity soak, and ambient recovery |
| Compliance | ASTM B117, ASTM G85 (Annexes A1–A5), ISO 9227, ISO 11997, GMW14872, SAE J2334, VW PV1210, Ford CETP, Renault D17 2025, Chrysler MS-AE-0004 |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | CRH600-HSC |
| Salt Spray Deposition Rate | 0.5–3 mL/h·80 cm² |
| Temperature Range | Ambient to 70 °C |
| Chamber Capacity | 640 L |
| Humidity Control | Yes (RH 10–95% RH, ramp rate programmable) |
| Optional Features | Spray Module, Nozzle Auto-Cleaning System, Preconditioned Air Humidification |
| Compliance | ASTM B117, ISO 9227, GMW 14872, SAE J2334, Ford CETP, VW PV1210, Renault D17 2027, GB/T 10125, ISO 16701, Prohesion™ |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | CRH600-HSC |
| Chamber Capacity | 640 L |
| Humidity Control Range | 10–95% RH (±2% RH typical accuracy) |
| Temperature Range | Ambient +10°C to 70°C |
| Salt Fog Deposition Rate | 1.0–2.0 mL/80 cm²/h (adjustable per ASTM B117) |
| Heating Method | Forced-air convection (no steam generation) |
| Compliance | ASTM B117, ISO 9227, GMW 14872, SAE J2334, Ford CETP, VW PV1210, Renault D17 2025, GB/T 10125, ISO 16701, Prohesion™ protocol |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-LAB Q-FOG SSP-600 / SSP-1100 / CCT-600 / CCT-1100 |
| Spray Mode | Continuous Atomization |
| Spray Rate | 1–5 L/h per 180 cm² |
| Nozzle Pressure | 0.7–1.0 kg/cm² |
| Fog Removal Method | Air-Pressure-Assisted Exhaust |
| Salt Fog Deposition Rate | 1–2 mL per 80 cm²·h |
| Temperature Range | 10–80 °C |
| Chamber Capacities | 640 L (SSP-600/CCT-600), 1103 L (SSP-1100/CCT-1100) |
| Sample Capacity | 160 specimens (75 mm × 150 mm) for 600-series |
| Humidity Control | Up to 100% RH (CCT models only) |
| Integrated Solution Reservoir | 120 L with built-in saltwater filter and low-level alarm |
| Heating/Cooling System | Internal resistive heaters + high-capacity forced-air cooling/drying fan |
| Controller | Microprocessor-based with self-diagnostic functions, cycle programming, service reminders, and safety shutdown |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor (not OEM) |
| Product Origin | Imported |
| Model | Q-FOG Series (e.g., Q-FOG CRH, Q-FOG SST, Q-FOG CCT) |
| Pricing | Available Upon Request |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Q-FOG |
| Spray Mode | Continuous Spray |
| Spray Rate | 1–5 L/h per 180 cm² |
| Nozzle Pressure | 0.7–1 kg/cm² |
| Fog Removal Method | Air-Compression Exhaust |
| Salt Fog Deposition Rate | 0.5–3 mL/h·80 cm² |
| Temperature Range | Ambient to 70 °C |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-FOG Gas Corrosion Test Chamber |
| Temperature Range (°C) | Consult Technical Specifications |
| Corrosive Gas Compatibility | SO₂, H₂S, Cl₂, NO₂, CO₂, NH₃ (configurable per test standard) |
| Chamber Volume | Standard 60 L / 110 L / 1400 L options |
| Control System | Integrated microprocessor-based controller with real-time monitoring and programmable cycle sequencing |
| Compliance | ASTM B809, IEC 60068-2-60, ISO 21207, DIN EN ISO 16701, JIS Z 2371 (gas corrosion variants), UL/CSA certified electrical safety |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Q-FOG SSP 1100 |
| Spray Mode | Continuous Atomization |
| Spray Rate | 1–5 L/h per 180 cm² |
| Nozzle Air Pressure | 0.7–1.0 kg/cm² |
| Fog Removal Method | Compressed-air-assisted雾 expulsion |
| Salt Fog Deposition Rate | 1–2 mL per 80 cm²·h |
| Temperature Range | 20–60 °C |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Q-FOG SSP and CCT |
| Spray Method | Multiple (including continuous salt spray, Prohesion™, and cyclic humidity/dry phases) |
| Nozzle Pressure | 0.7–1.4 bar |
| Salt Solution Deposition Rate | 1.0–2.0 mL per 80 cm² per hour |
| Temperature Range | 35–70 °C |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Q-FOG SSP |
| Spray Mode | Continuous Spray |
| Spray Rate | 1–5 L/h per 180 cm² |
| Nozzle Air Pressure | 0.7–1 kg/cm² |
| De-misting Method | Pneumatic Air-Driven Fog Exhaust |
| Salt Solution Reservoir Capacity | 120 L |
| Operating Temperature Range | Ambient to 50°C (controlled per cycle phase) |
| Cycle Phases | Salt Fog, Dry-off, Rest (Static), Optional Humidity (CCT only) |
| Compliance | ASTM B117, ASTM G85 (Annex A1–A5), ISO 9227, BS 3900 F4/F9, DIN 50021 |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-FOG SSP |
| Compliance | ASTM B117, ASTM G85, ISO 9227, BS 3900 F4/F9, DIN 50021 |
| Cycle Capabilities | Salt Spray, Prohesion®, Dry-off, Optional Humidity (CCT only) |
| Control System | Microprocessor-based dual-line LCD interface with programmable multi-step cycling |
| Construction | Fiberglass-reinforced polymer (FRP) chamber body, corrosion-resistant stainless steel hardware |
| Temperature Range | Ambient to 50 °C (spray/dry modes), up to 60 °C (optional humidified mode in CCT models) |
| Solution Delivery | Pneumatic air-assisted atomization via adjustable nozzles, bubble-tower humidified air (except Prohesion®) |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | SSP |
| Salt Fog Deposition Rate | 0.5–3 mL/h·80 cm² |
| Temperature Range | Ambient to 70°C |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Q-FOG SSP |
| Compliance | ASTM B117, ASTM G85 (Prohesion), ISO 9227, BS 3900 F4/F9, DIN 50021 |
| Chamber Volume | 640 L (SSP-600) or 1103 L (SSP-1100) |
| Temperature Range | Ambient to 50 °C (operational during salt fog cycle) |
| Salt Solution Delivery | Precision metered pneumatic spray system with adjustable nozzle pressure and calibrated collection rate (1.0–2.0 mL/80 cm²/h per ASTM B117) |
| Control System | Touchscreen programmable controller with multi-step cycling capability, real-time logging, and audit-trail-ready event history |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | SSP Series |
| Compliance | ASTM B117, ASTM G85 (Prohesion™), ISO 9227, BS 3900-F4/F9, DIN 50021 |
| Temperature Range | Ambient to 50 °C (operational range for salt fog and dry-off cycles) |
| Salt Solution Delivery | Precision metered spray via pneumatic atomization |
| Chamber Capacity | Available in multiple standard sizes (e.g., SSP-600, SSP-1200) |
| Control System | Touchscreen PLC-based controller with cycle programming and real-time logging |
| Humidity Control | Not applicable (non-humidity-controlled |
| Salt Fog Deposition Rate | 1.0–2.0 mL/80 cm²/h (adjustable per ASTM B117) |