Q-LAB
Filter
Showing 211–240 of 281 results
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | QUV/Se |
| Test Duration | Adjustable |
| Irradiance Range | Adjustable |
| Lamp Power | Adjustable |
| Humidity Range | Adjustable |
| Light Exposure Temperature Range | 45–80 °C |
| Black Panel Temperature Range | 45–80 °C |
| UV Wavelength Range | 320–400 nm |
| Chamber Dimensions (L×W×H) | 48 cm × 75 cm × 150 cm |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | QUV/SE |
| Chamber Dimensions (L×W×H) | 114 × 50 × 40 cm |
| Light Source Options | UVA-340 or UVB-313 fluorescent lamps |
| Irradiance Control | Solar Eye® closed-loop feedback system |
| Black Panel Temperature Range | 35–80 °C |
| Condensation Temperature Range | 40–60 °C |
| Illumination Temperature Range | 45–80 °C |
| Sample Capacity | 48 specimens (75 × 150 mm) |
| Power Supply | 120 V / 60 Hz, 16 A or 230 V / 50–60 Hz, 8 A |
| Water Consumption | 8 L/day (condensation mode) |
| Lamp Life (avg.) | 5000 h |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | QUV/se |
| UV Wavelength Range | 280–400 nm |
| Sample Capacity | 24 pieces of 75 mm × 300 mm specimens or 48 pieces of 75 mm × 150 mm specimens |
| Lamp Options | UVB-313 (for aggressive, high-intensity UV stress) and UVA-340 (spectrally matched to terrestrial solar UV, 295–365 nm) |
| Compliance | ASTM G154, ASTM G151, ISO 4892-3, ISO 11507, JIS K 5600-7-8, SAE J2020, DIN 53384, GB/T 14522, and other international weathering standards |
| Condensation Capability | Yes, for realistic moisture cycling simulation |
| Irradiance Control | Solar Eye® closed-loop feedback system calibrated per ISO/IEC 17025-accredited procedures |
| Chamber Construction | Stainless steel interior, corrosion-resistant housing, precision-engineered UV reflector geometry |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | QUV/se |
| Price | Upon Request |
| UV Irradiance Control | SOLAR EYE Feedback System |
| UV Lamp Types | UVA-340, UVA-351, UVB-313, QFS-40, Cool White (QUV/se/cw only) |
| Black Panel Temperature Range | 35–80 °C |
| Chamber Temperature Range | 25–80 °C |
| UV Wavelength Range | 295–400 nm (lamp-dependent) |
| Test Chamber Dimensions (L×W×H) | 114 × 51 × 42 cm |
| Sample Capacity | Up to 48 specimens (75 mm × 150 mm) |
| Condensation Mechanism | Distilled-water-equivalent cold condensation using tap water |
| Compliance | ASTM G154, ISO 4892-3, JIS D0205, SAE J2020, GB/T 14522, MIL-STD-810, FDA 21 CFR Part 11 (with optional software) |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-LAB-QUV/se |
| Sample Capacity | 48 × 75 mm × 150 mm specimens |
| UV Lamp Options | UVA-340 (295–365 nm), UVB-313 (peak at 313 nm) |
| Condensation Humidity Simulation | Yes, via heated water pan |
| SOLAR EYE Irradiance Control System | Yes, with ISO-traceable calibration |
| Temperature Control | Black panel temperature range up to 80 °C, chamber air temperature up to 70 °C |
| Compliance | ASTM G154, ISO 4892-3, JIS D0205, SAE J2020, GB/T 14522, and other international UV weathering standards |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | QUV/se |
| Light Exposure Temperature Range | 45–80 °C |
| Condensation Temperature Range | 40–60 °C |
| UV Wavelength Range | 290–400 nm (UVA-340 & UVB-313 lamp options) |
| Chamber Internal Dimensions (L×W×H) | 110 × 105 × 50 cm |
| Sample Capacity | 48 standard panels (75 × 150 mm) |
| Power Supply | 230 V / 50 Hz, 1500 W |
| Weight | 136 kg |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | QUV/se |
| Sample Capacity | 24 pcs (75 mm × 300 mm) or 48 pcs (75 mm × 150 mm) |
| UV Irradiance Control | Yes (Solar Eye® feedback system) |
| Condensation Simulation | Yes |
| Compliance | ASTM G154, ISO 4892-3, JIS K 5600-7-8, SAE J2020, GB/T 14522, and other international standards |
| Chamber Dimensions (L×W×H) | As specified in technical documentation |
| Black Panel Temperature Range | As specified in technical documentation |
| UV Wavelength Range | UVA-340 (315–400 nm) or UVB-313 (280–315 nm), configurable per lamp type |
| Illumination Uniformity | ±15% across specimen plane per ASTM G154 Annex A1 |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | QUV/se |
| UV Wavelength Range | 280–400 nm |
| Condensation System | Yes |
| Irradiance Control | SOLAR EYE® Feedback-Controlled UV Intensity |
| Sample Capacity | Up to 48 specimens (75 mm × 150 mm) |
| Temperature Control | Precise black-panel and chamber air temperature regulation |
| Compliance | ASTM G154, ISO 4892-3, JIS D0205, SAE J2020, FDA 21 CFR Part 11 (with optional software), GLP/GMP-ready data logging |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | QUV/se |
| UV Wavelength Range | 295–400 nm (UVA-340), 280–360 nm (UVB-313) |
| Black Panel Temperature Range | 30–75 °C |
| Irradiance Control | SOLAR EYE® Closed-Loop Radiometric Feedback System |
| Condensation Mechanism | Water Jacket Heating with 100% RH Saturation |
| Compliance | ASTM G154, ISO 4892-3, JIS D0205, SAE J2020, GB/T 14522, FDA 21 CFR Part 11 (via optional audit trail software) |
| Sample Capacity | Configurable per standard chamber dimensions (standard internal volume: 45 L) |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model Variants | QUV/se, QUV/spray, QUV/cw, QUV/uvc |
| Lamp Power | 1800 W |
| Humidity Range | ≥95% RH |
| Black Panel Temperature Range | 45–80 °C |
| UV Wavelength | 340 nm (UVA-340) |
| Chamber Dimensions (L×W×H) | 137 × 53 × 135 cm |
| Test Duration Capability | Up to 5000 hours |
| Compliance | ASTM G154, ASTM G151, ISO 4892-3, JIS D0205, SAE J2020, ISO 11507, IEC 60335, AATCC TM186, and others |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | QUV/se/Spray |
| Quotation | Upon Request |
| UV Wavelength Range | 340–400 nm |
| Chamber Dimensions (L×W×H) | 137 × 53 × 135 cm |
| Black Panel Temperature Range | Consult Technical Support |
| Irradiance Control | Solar Eye® Feedback System |
| Condensation Simulation | Yes |
| Water Spray Function | Yes |
| Sample Capacity | Up to 48 standard specimen racks (each holds two 75 × 150 mm samples) |
| Calibration | ISO/IEC 17025-compliant via CR-10 UV Radiometer traceable to NIST |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | QUV/SP |
| Pricing | Upon Request |
| UV Irradiance Control | SOLAR EYE® Radiometric Feedback System |
| Black Panel Temperature Range | 35–80 °C (adjustable) |
| Cabinet Dimensions (L×W×H) | 1120 × 570 × 540 mm |
| Internal Chamber Volume | ~34 L |
| UV Lamp Type | UVA-340 or UVB-313 Fluorescent Lamps |
| Condensation Cycle | Automatic distilled-water condensation via heated water pan |
| Spray Function | Optional integrated water spray (deionized water recommended) |
| Compliance | ASTM G154, ISO 4892-3, SAE J2020, IEC 61215, GB/T 14522, MIL-STD-810G |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | QUV/SP |
| Light Source Options | UVA-340, UVA-351, UVB-313, QFS-40, Cool White Fluorescent |
| Temperature Control | Black Panel & Chamber Air Temperature |
| Condensation Simulation | Yes |
| Irradiance Control | Solar Eye® (Standard on QUV/SP) |
| Compliance | ASTM D4329, ASTM D4587, ISO 11507, IEC 61345, AATCC TM186, and over 30 additional international standards |
| Chamber Dimensions | See technical datasheet |
| Warranty | 5,000-hour lamp life guarantee |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | QUV/Spray |
| Test Duration | 1–5000 h |
| Irradiance Range | Adjustable |
| Lamp Power | Adjustable |
| Humidity Range | 0–95% RH |
| Black Panel Temperature Range | 45–80 °C |
| UV Wavelength Range | 280–400 nm |
| Spray Nozzles | 12 (Total Flow Rate: 7 L/min) |
| Sample Capacity | 48 standard panels (75 × 150 mm) |
| Irradiance Control | Closed-loop “SunEye” system with ±0.01 W/m² @ 340 nm display resolution |
| Compliant Standards | ASTM G154, ISO 4892-3, JIS D0205, SAE J2020, GB/T 14522, DIN 50017, BS EN 60068-2-5 |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | QUV/spray |
| UV Wavelength Range | 280–340 nm |
| Sample Capacity | 48 specimens (75 × 150 mm) |
| Condensation Temperature Range | 40–60 °C |
| Irradiance Control | Solar Eye® closed-loop feedback system |
| Lamp Options | UVA-340, UVB-313, Cool White fluorescent |
| Lamp Lifetime (avg.) | 5,000 h (UVA-340/UVB-313) |
| Power Supply | 120/60 V/Hz, 20 A or 230/50–60 V/Hz, 9 A |
| Water Consumption | 8 L/day (condensation) + spray cycle |
| Compliance | ASTM G154, ISO 4892-3, SAE J2020, JIS D0205, GB/T 14522, FDA 21 CFR Part 11 (software-enabled audit trail) |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | QUV/Spray |
| Sample Capacity | Up to 48 specimens (75 mm × 150 mm) |
| UV Lamp Types | UVA-340, UVA-351, UVB-313 |
| Condensation System | Integrated water condensation with self-purifying distilled water cycle |
| Spray Function | Deionized water spray for thermal shock and mechanical erosion simulation |
| Compliance | ASTM G154, ISO 4892-3, JIS D0205, SAE J2020, GB/T 14522 |
| Calibration Support | AUTOCAL-compatible, UC1/UC10/CR10 irradiance calibration systems |
| Temperature Control | Black panel thermometer (BPT) and chamber air temperature monitoring |
| Optional Accessories | Pure Water Recycling System, Space-Saving Stacking Frame, Multi-geometry sample holders (lenses, 3D parts, textiles, vials) |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | QUV/spray |
| UV Wavelength Range | 320–400 nm (UVA-340, UVA-351, UVB-313, QFS-40, Cool White options) |
| Sample Chamber Dimensions | Custom-configurable (standard internal volume: 160 L) |
| Black Panel Temperature Range | 35–80 °C |
| Irradiance Control | SOLAR EYE® broadband or narrowband (340 nm or 313 nm) |
| Condensation Cycle | Distilled-quality water generated via in-situ evaporation/condensation |
| Lamp Life | Up to 5,000 hours (spectral stability maintained per ASTM G154 Annex A1) |
| Compliance | ASTM G154, ISO 4892-3, SAE J2020, JIS D0205, GB/T 14522, FDA 21 CFR Part 11 (via optional software audit trail) |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Q-Lab QUV/spray |
| Test Duration | Adjustable |
| Irradiance Range | Adjustable |
| Lamp Power | Adjustable |
| Humidity Range | Adjustable |
| Light Exposure Temperature Range | 45–80 °C |
| Black Panel Temperature Range | 45–80 °C |
| UV Wavelength Range | 320–400 nm |
| Chamber Internal Dimensions (L×W×H) | 480 mm × 750 mm × 1500 mm |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | QUV/spray |
| Pricing | Upon Request |
| UV Irradiance Control | Yes |
| Black Panel Temperature Range | 35–80 °C (adjustable) |
| Condensation Temperature Range | 25–60 °C |
| UV Wavelength Range | UVA-340 (310–400 nm), UVB-313 (280–360 nm) |
| Test Chamber Dimensions (L×W×H) | 115 × 50 × 40 cm (45.3 × 19.7 × 15.7 in) |
| Lamp Type | Fluorescent UV-A and UV-B tubes (Q-Lab proprietary design) |
| Humidity Simulation | Condensation + Optional Water Spray |
| Compliance | ASTM G154, ISO 11507, JIS D0205, SAE J2020, GB/T 14522, and over 50 international standards |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | QUV/Spray |
| Chamber Internal Dimensions (L×W×H) | Configurable per standard specimen rack layout (supports 48 × 75 mm × 150 mm specimens) |
| UV Lamp Options | UVA-340, UVB-313 |
| Irradiance Control | Yes (calibrated broadband UV sensor) |
| Temperature Range | 45–80 °C (irradiation), 40–60 °C (condensation) |
| Humidity Simulation | Condensation (distilled water, ~8 L/day) + Spray Cycle (distilled water, ~7 L/min) |
| Power Supply | 230 V / 50 Hz, 1500 W |
| Weight | 136 kg |
| Compliance | ASTM G154, ISO 4892-3, JIS D0205, SAE J2020, FDA 21 CFR Part 11 (via optional software package) |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | QUV/spray |
| UV Wavelength Range | 340–420 nm |
| Sample Capacity | 48 × 75 mm × 150 mm specimens |
| Lamp Life (avg.) | 5000 h |
| Power Supply | 120/60 V/Hz, 20 A |
| Water Consumption | Condensation: 8 L/day |
| Spray | 7 L/min |
| Compliance | ISO 9000, ASTM G154, ISO 4892-3, IEC 60068-2-5, FDA 21 CFR Part 11 (via optional software audit trail) |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | QUV/spray |
| UV Wavelength Range | 280–400 nm |
| Compliance | ASTM G151, ASTM G154, ISO 4892-3, ISO 11507, JIS D 0205, SAE J2020, GM 9125P, NACE TM-01-84, and over 50 additional international standards |
| Irradiance Control | Solar Eye® closed-loop feedback system |
| Sample Capacity | 48 specimens (75 mm × 150 mm) |
| Condensation Cycle Temperature Range | 40–60 °C |
| UV Irradiation Cycle Temperature Range | 45–80 °C |
| Lamp Life | 5,000 hours (UVA-340 lamps) |
| Power Supply | 120 V/60 Hz, 20 A or 230 V/50–60 Hz, 9 A |
| Water Consumption | 8 L/day (deionized water for spray) |
| Brand | Q-LAB |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | QUV/spray |
| Illumination Temperature Range | 45–80 °C |
| Black Panel Temperature Range | 40–60 °C |
| UV Wavelength | UVA-340, UVB-313EL, UVA-351 selectable |
| Chamber Internal Dimensions (L×W×H) | 114 × 52 × 42 cm |
| Sample Capacity | 48 specimens (75 mm × 150 mm) |
| Irradiance Control Point | 340 nm |
| Adjustable Irradiance Range | 0.25–1.80 W/m² @ 340 nm |
| Irradiance Display Accuracy | ±0.01 W/m² |
| Lamp Life | ~5,000 hours (dependent on irradiance setting and cycle profile) |
| Power Supply | 230 V / 50 Hz, 1500 W max |
| Weight | 136 kg |
| Water Requirements | Deionized water, resistivity ≥ 200 kΩ·cm, total solids ≤ 1.0 ppm, colloidal silica ≤ 0.1 ppm, pressure 25–80 psi, flow rate ≥ 20 L/min |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | QUV/Spray |
| UV Wavelength Range | 280–400 nm |
| Sample Capacity | Up to 48 specimens (75 mm × 150 mm) |
| Lamp Life | 5,000 hours |
| Compliance | ASTM G154, ISO 11507, ASTM D4587, JIS D0205, SAE J2020, AATCC TM186, ISO 4892-3 |
| Control System | SOLAR EYE irradiance feedback control with AUTOCAL calibration |
| Humidity Simulation | Condensation + Water Spray (deionized water recommended) |
| Temperature Control | Black panel and chamber air temperature regulation |
| User Interface | Multilingual (English, French, Spanish, Italian, German) |
| Connectivity | Ethernet-enabled for data logging and remote diagnostics |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | QUV/spray |
| UV Wavelength Range | 295–400 nm (UVA-340, UVA-351, UVB-313, QFS-40, Cool White options) |
| Sample Capacity | Up to 48 specimens (75 mm × 150 mm) |
| Condensation System | Distillation-purified water cycle |
| Spray Function | Deionized water only |
| Compliance | ASTM G154, ISO 4892-3, SAE J2020, GB/T 14522, IEC 61215, MIL-STD-810, FDA 21 CFR Part 11 (with optional software) |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | QUV/spray |
| UV Wavelength | 340 nm |
| Compliance | ASTM G151, ASTM G154, ISO 11507, ISO 4892-3, JIS D 0205, SAE J2020, GM 9125P, NACE TM-01-84, ANSI C57.12.28, UNE 53.104, and others |
| Irradiance Control | Solar Eye® closed-loop feedback system |
| Spray Function | Integrated deionized water spray cycle |
| Condensation | Yes |
| Lamp Type | UVA-340 (standard), UVB-313 (optional) |
| Sample Capacity | 48 specimens (75 × 150 mm) |
| Operating Temperature Range (Irradiation) | 45–80 °C |
| Operating Temperature Range (Condensation) | 40–60 °C |
| Power Supply | 120 V/60 Hz, 20 A or 230 V/50–60 Hz, 9 A |
| Water Consumption | 8 L/day (spray + condensation) |
| Lamp Lifetime | 5,000 h (UVA-340) |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | QUV/spray |
| Exposure Time Range | 1–5000 h |
| Irradiance Control | 10 W/m² (UVA-340 calibrated) |
| UV Lamp Options | UVA-340, UVB-313, Cool White |
| Condensation Temperature Range | 40–60 °C |
| Irradiation Temperature Range | 45–80 °C |
| Sample Capacity | 48 specimens (75 × 150 mm) |
| Power Supply | 120 V/60 Hz, 20 A or 230 V/50–60 Hz, 9 A |
| Water Consumption | 8 L/day (spray mode) |
| Compliance | ASTM G154, ISO 4892-3, SAE J2020, GB/T 14522, JIS D0205 |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | QUV/Spray |
| Compliance | ASTM G154, ASTM G151, ISO 4892-3, JIS D0205, SAE J2020, ISO 11507, ASTM D4587, ASTM D4329 |
| Sample Capacity | 48 × 75 mm × 150 mm specimens |
| UV Lamp Options | UVA-340 (295–365 nm), UVB-313 (280–365 nm) |
| Irradiance Control | Yes |
| Condensation & Spray Cycles | Integrated |
| Temperature Range | 30–80 °C (black panel) |
| Humidity Control | Not applicable (non-hygrometric) |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Q-LAB QUV/spray |
| Price | Upon Request |
| UV Wavelength Range | 290–400 nm (UVA-340 & UVB-313 lamp options) |
| Irradiance Control | Yes (SOLAR EYE sensor optional) |
| Black Panel Temperature Range | 35–80 °C |
| Chamber Temperature Range (Air) | 25–80 °C |
| Condensation Temperature Range | 35–60 °C |
| Chamber Dimensions (L×W×H) | 114 × 51 × 42 cm (45 × 20 × 16.5 in) |
| Sample Capacity | Up to 48 specimens (75 mm × 150 mm) |
| Spray Function | Integrated deionized water spray system with adjustable duration/frequency |
| Compliance | ASTM G154, ISO 4892-3, SAE J2020, GB/T 14522, JIS D0205 |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Distributor Type | Authorized Distributor |
| Import Status | Imported |
| Model | QUV/Spray |
| Irradiance Range | 0.48–0.95 W/m² @ 340 nm |
| Test Duration | Adjustable from 1 to 9999 hours |
| UV Wavelength Range | 250–400 nm |
| Chamber Capacity | Up to 48 specimens (75 mm × 150 mm each) |
