Thermo Fisher
Filter
Showing 61–90 of 376 results
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Portable Dose Rate and Integrated Dose Meter |
| Detector Compatibility | Interchangeable (NaI(Tl), He-3 neutron, GM, scintillation, or proportional detectors) |
| Measurement Range Extension | Up to 4 m via modular fiberglass telescopic pole |
| Weight | 2.6 kg |
| Compliance | Meets IEC 60846-1:2014, IEC 61526:2010, and EURATOM Basic Safety Standards Directive 2013/59 |
| Software Interface | USB and Bluetooth connectivity for real-time data logging and remote monitoring via Thermo Fisher RadEye Suite |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | FHT 1377 PackEye |
| Instrument Category | Dose Rate Meter |
| Portability | Portable |
| Measured Radiation Types | Gamma and Neutron |
| Detector Configuration | Dual Plastic Scintillator + Two He-3 Proportional Counters |
| Dose Rate Range | 50 nSv/h – 2 mSv/h |
| Sensitivity | 50 nSv/h |
| Power Consumption | 350 mW |
| Battery Life | ~70 h (7.2 V, 3600 mAh rechargeable Li-ion) |
| Dimensions | 58 cm (H) × 30 cm (W) × 18 cm (D) |
| Weight | 6 kg |
| Data Update Interval | 100 ms |
| LED Indication | 10-level gamma / 10-level neutron |
| Communication | Bluetooth + GPS interface |
| Compliance | IAEA-recommended system for orphan source search |
| Key Technology | Patented Natural Background Rejection (NBR), Digital Filtering, Low-Power Embedded Electronics |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Portable Dose Rate Meter |
| Model | FHT 40NBR |
| Detector Configuration | Dual-detector (NaI(Tl) scintillation crystal + plastic scintillator) |
| Measurement Principle | Gamma photon energy discrimination via pulse-height analysis and NBR (Natural Background Rejection) algorithm |
| Compliance | Designed for field-deployable radiological survey per IEC 60846-1:2014, ANSI N42.33, and EURATOM Directive 2013/59/Euratom |
| Data Interface | USB and Bluetooth® 4.0 |
| Storage Capacity | Up to 10,000 timestamped dose rate records |
| Operating Temperature | –10 °C to +50 °C |
| IP Rating | IP67 |
| Battery Life | >100 hours (alkaline) or >200 hours (rechargeable Li-ion) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | 4640040 |
| Instrument Type | Single-Channel Pipette |
| Automation Level | Manual |
| Channels | 1 |
| Volume Range | 10–100 µL |
| Accuracy | ±3.0% to ±0.8% (volume-dependent, per ISO 8655) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Italy |
| Model | FlashSmart CHN |
| Measurement Elements | C, H, N (expandable to CHNSO, CHNS, NCS, NC, N, S, O) |
| Analysis Time | 5–10 min (sample-weight and matrix dependent) |
| Detection Limit | <40 ppm |
| Accuracy | ≤0.05% |
| Sample Volume | up to 500 µL |
| Detectors | Thermal Conductivity Detector (TCD), Flame Photometric Detector (FPD), Infrared Detector (IR), Isotope Ratio Mass Spectrometer (IRMS) interface |
| Combustion Temperature | up to 1800 °C |
| Brand | Thermo Fisher |
|---|---|
| Origin | Italy |
| Model | FlashSmart CN/CNS |
| Detection Principle | Dynamic Flash Combustion coupled with Gas Chromatographic Separation |
| Detector Options | TCD (standard), optional chemiluminescence or IR detectors |
| Combustion Temperature | up to 1800 °C (Sn capsule mode) |
| Warranty | 15 years on combustion furnace and TCD detector |
| Automation | Fully software-controlled oxygen injection, sample weighing, and combustion timing |
| Compliance | Designed for GLP/GMP environments |
| Carrier Gas Options | Helium (standard), Argon (cost-optimized alternative) |
| Modular Configurations | Upgradable to CHNS, CHN, NC, NCS, N, S, O modes |
| Sample Types | Solids (soils, sediments, biomass, coal, polymers), liquids (oils, extracts, aqueous solutions), and heterogeneous matrices |
| Throughput | Up to 120 samples/day with dual autosamplers (solid + liquid) |
| Software Platform | EagerQ™ v3.2 with method templates, calibration wizards, and raw data export (CSV, XML, PDF) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Italy |
| Instrument Type | Dumas Combustion Method |
| Automation Level | Fully Automated Elemental Analyzer |
| Nitrogen Measurement Range | 0.001–500 mg N |
| Reproducibility | <0.3% RSD |
| Sample Mass Requirement | ≥1 g |
| Recovery Rate | 99.5–100% |
| Digestion/Combustion Time | 3–4 min per sample |
| Linear Range | 0.001–500 mg N |
| Power Consumption | 1400 W |
| Dimensions (L×W×H) | 620 × 580 × 500 mm |
| Sample Capacity | Up to 125 positions (with optional 4-position carousel) |
| Compliance | ASTM D5142, AOAC 992.15, ISO 14891, EN ISO 16634-1/-2, USP <28>, FDA 21 CFR Part 11 ready (via EagerSmart software audit trail) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Italy |
| Instrument Type | Dumas Combustion Method |
| Automation Level | Fully Automated Nitrogen Determinator |
| Nitrogen Range | 0.001–500 mg N |
| Reproducibility | <0.3% RSD |
| Sample Weight | ≥1 g |
| Recovery Rate | 99.5–100% |
| Digestion/Combustion Time | 3–4 min per sample |
| Power Consumption | 1400 W |
| Dimensions (L×W×H) | 620 × 580 × 500 mm |
| Linearity Range | 0.001–500 mg N |
| Sample Capacity | Up to 125 positions (with optional multi-rack configuration) |
| Gas Flow Control | Electronic Flow Control (EFC) |
| Software Platform | EagerSmart™ Operating Software |
| Compliance | ASTM D515, ISO 13878, AOAC 992.15, USP <467>, EN ISO 13878, and GLP/GMP-ready audit trail support |
| Brand | Thermo Fisher |
|---|---|
| Origin | Italy |
| Model | FlashSmart |
| Element Range | CHNSO, CHNS, CHN, NCS, NC, N, S, O (configurable modes) |
| Analysis Time | 5–10 min (sample-weight- and matrix-dependent) |
| Detection Limit | <40 ppm (S: down to 4 ppm with FPD/IR |
| Measurement Precision | ≤0.05% RSD |
| Sample Introduction | Up to 500 µL liquid or 1 g solid |
| Detector Options | Thermal Conductivity Detector (TCD), Flame Photometric Detector / Infrared Detector (FPD/IR), Isotope Ratio Mass Spectrometer (IRMS) interface, Chlorine (Cl) measurement module |
| Combustion Temperature | Up to 1800 °C |
| Compliance | Designed for GLP/GMP environments |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | FoodDefender RM |
| Instrument Category | Handheld Raman Spectrometer |
| Spectral Range | 250 cm⁻¹ to 2875 cm⁻¹ |
| Spectral Resolution | 7–10.5 cm⁻¹ (FWHM, full range) |
| Spatial Resolution | 7–10.5 cm⁻¹ (Raman), 4 cm⁻¹ (IR-equivalent reference) |
| Minimum Wavenumber | 250 cm⁻¹ |
| Spectral Reproducibility | ≤ ±0.5 cm⁻¹ shift across three consecutive scans on homogeneous sample |
| Weight | 800 g |
| Dimensions | 19.3 × 10.7 × 4.4 cm |
| Laser Output Power | Adjustable (75 / 125 / 250 mW) |
| Numerical Aperture | NA = 0.23 |
| Working Distance | 17 mm |
| Spot Size | 0.14–1.8 mm |
| Integration Time | Manual or auto mode (minimum 5 ms) |
| Delay Time | Configurable (0–120 s) |
| Power Supply | Rechargeable Li-ion battery or two 123A alkaline cells |
| Operating Temperature | −20 °C to +40 °C |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | G2397-60720 |
| Type | OEM Replacement Component for Gas Chromatography–Electron Capture Detection Systems |
| Compliance | Designed for use with Thermo Scientific™ TRACE™ and ISQ™ GC-MS platforms |
| Brand | Thermo Fisher |
|---|---|
| Origin | Finland |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Laboratory Water Quality Analyzer |
| Model | Gallery |
| Instrument Category | Benchtop Automated Discrete Analyzer |
| Detection Methods | Photometric (275–880 nm, 12 fixed filters), Enzymatic, Electrochemical (ISE-based pH & Conductivity) |
| Throughput | Up to 200 tests/hour |
| Sample Capacity | 9-position rack × 2 = 18 racks (162 samples) |
| reagent capacity | 6 positions × 9 slots = 54 reagent positions |
| Cuvette Format | Disposable 10-cell flexible strip cuvettes |
| Incubation | Temperature-controlled incubation disc, programmable reaction time |
| Automation Features | Integrated barcode reader, auto-dilution (primary & secondary), on-board washing station, refrigerated sample/reagent carousel |
| Power/Water | <1.5 L/h water consumption |
| Regulatory Compliance | Designed for GLP/GMP environments |
| Brand | Thermo Fisher |
|---|---|
| Origin | Finland |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Laboratory Water Quality Analyzer |
| Model | Gallery Plus |
| Instrument Category | Benchtop Discrete Analyzer |
| Detection Principles | Photometric (Colorimetric), Enzymatic, and Electrochemical (ISE-based) |
| Sample Throughput | Up to 350 tests/hour |
| Wavelength Range | 275–880 nm (12 fixed-position interference filters) |
| Sample Capacity | 54 positions |
| Refrigerated Reagent Capacity | 42 positions |
| Reaction Vessel Format | 10-cell cuvette strips (up to 18 × 2 strips = 360 tests) |
| Incubation | Adjustable temperature incubation block (9 lanes × 10 positions = 90 test slots) |
| Electrochemical Module (ECM) | Integrated ISE-based pH and conductivity measurement |
| Sample Handling | Dual independent probes (sample + reagent), dedicated wash station, barcode reader |
| Dilution Capability | Onboard primary and secondary auto-dilution |
| Power & Utility | <2.5 L/h water consumption |
| Software Compliance | Audit-trail enabled, user-access control, electronic signature support per FDA 21 CFR Part 11 |
| Regulatory Alignment | Designed to support ISO/IEC 17025, ASTM D1293 (pH), ASTM D1125 (conductivity), EPA 365.3 (phosphate), USP <731>, and GLP/GMP workflows |
| Brand | Thermo Fisher |
|---|---|
| Origin | Finland |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | Gallery Beermaster |
| Instrument Category | Alcoholic Beverage and Beverage Analyzer |
| Detection Principle | Photometric (Colorimetric), Enzymatic, and Iso-Alpha Acid Extraction-Based Bitterness (IBU) Analysis |
| Wavelength Range | 275–775 nm |
| Reaction Volume | Microliter-scale (≤100 µL total per assay) |
| Sample Throughput | Random-access, high-volume batch processing |
| Cell Type | Disposable, multi-cuvette, discrete cuvettes |
| Dilution Capability | Automated primary and secondary dilution |
| Blank Correction | Multiple built-in blank reading modes (reagent blank, sample blank, dual-blank) |
| Software Compliance | Audit trail, user access control, method versioning — supports GLP/GMP documentation requirements |
| Brand | Thermo Fisher |
|---|---|
| Origin | United Kingdom |
| Model | Gemini AS |
| Automation Level | Fully Automatic |
| Instrument Type | Rotary Stainer |
| Heating Stations | 5 independent |
| Reagent Positions | 26 or 31 |
| Water Stations | 4 |
| Slide Capacity per Rack | Standard (compatible with standard histology slide racks) |
| Emergency STAT Processing | Yes, priority queueing for urgent cases (e.g., Mohs surgery) |
| Backup Power | 40-minute battery runtime |
| Compliance Features | Integrated fume management, anti-siphon valves, flow regulators, locked slide baskets, password-protected protocol editing |
| Software | Scheduler™ with editable protocols, preloaded Thermo Scientific Signature™ stain protocols |
| Connectivity | USB for protocol/log export |
| Footprint | Compact dual-level design with integrated touchscreen and power supply |
| Safety | Activated carbon filtration or vent adapter kit optional |
| Door Configuration | 4 configurable access doors |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Instrument Type | Imported |
| Model | GENESYS™ 140 |
| Optical Design | Double-beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 325–1100 nm |
| Wavelength Scanning | Automatic |
| Spectral Bandwidth | 5 nm |
| Wavelength Accuracy | ±0.5 nm |
| Stray Light | <0.05% T at 340 nm and 400 nm |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Instrument Type | Imported |
| Model | GENESYS 180 |
| Optical Design | Double-beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Selection | Manual |
| Spectral Bandwidth | 2 nm |
| Wavelength Accuracy | ±0.5 nm |
| Stray Light | <1.0%T at 198 nm (KCl), <0.05%T at 220 nm (NaI), <0.03%T at 340 nm (NaNO₂) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Instrument Type | Imported Dual-Beam UV-Vis Spectrophotometer |
| Model | GENESYS 40 |
| Optical Detector | Photodiode Array |
| Wavelength Range | 325–1100 nm |
| Wavelength Selection | Manual |
| Spectral Bandwidth | 5 nm |
| Wavelength Accuracy | ±0.5 nm |
| Stray Light | <0.05% T at 340 nm and 400 nm |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Instrument Type | Imported Dual-Beam UV-Vis Spectrophotometer |
| Model | GENESYS 50 |
| Optical Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.5 nm |
| Spectral Bandwidth | 2 nm |
| Stray Light | <1.0%T at 198 nm (KCl), <0.05%T at 220 nm (NaI), <0.03%T at 340 nm (NaNO₂) |
| Automation | Automatic Wavelength Scanning & Calibration |
| Sample Compartment | Removable, Washable Interior Liner |
| Display | 7-inch HD Touchscreen Interface |
| Method Management | Pre-programmed Smart Start Methods |
| Compatibility | Cuvettes (10 mm pathlength standard), Test Tubes, Microvolume Adapters (optional) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | CTS Xenon |
| High Voltage Range | 2500 V |
| Low Voltage Range | 500 V |
| Pulse Count | 1–10 |
| Pulse Duration | 1–30 ms |
| Output Waveform | Square Wave |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Type | Imported Laboratory-Scale Twin-Screw Extruder |
| Model | Eurolab 16 |
| Screw Diameter | 16 mm |
| L/D Ratio | 25:1 to 40:1 (modular) |
| Motor Power | 1.25 kW or 2.5 kW |
| Speed Range | 50–1000 rpm |
| Max Operating Pressure | 200 bar |
| Barrel Temperature Zones | 6–10 |
| Max Barrel Temperature | 350 °C (optional 450 °C) |
| Throughput | 0.5–5 kg/h |
| Drive System | PLC-controlled servo motor with real-time torque & temperature monitoring |
| Control Interface | Color LCD touchscreen with embedded HAAKE PolyLab software |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Model | HAAKE Falling Ball |
| Instrument Type | Falling Ball Viscometer |
| Viscosity Range | 0.5 – 100,000 mPa·s |
| Temperature Range | −1 °C to +26 °C |
| Repeatability | < 0.5 % |
| Reproducibility | < 1 % |
| Measurement Tube Material | Borosilicate Glass (Tubes 1, 2, G) |
| Ball Materials | Nickel–Iron Alloy (Balls 3, 4, 5, 6) |
| Compliance | DIN 53015, ISO 120587 |
| Optional Accessories | Digital Stopwatch, Ball G (for gas viscosity), PT100 Temperature Sensor for HAAKE D50 Circulator |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Instrument Type | Rotational Rheometer |
| Motor Bearing | Air Bearing |
| Minimum Rotational Speed | 1×10⁻⁸ rpm |
| Frequency Range | 1×10⁻⁶ – 100 Hz |
| Maximum Rotational Speed | 4500 rpm |
| Maximum Torque | 200 mNm |
| Torque Resolution | 0.1 nNm |
| Angular Displacement Resolution | 12 nrad |
| Normal Force Range | 0.01 – 50 N |
| Normal Force Resolution | 0.001 N |
| Vertical Travel | 240 mm |
| Gap Resolution | 0.5 µm |
| Minimum Vertical Speed | 0.02 µm/s |
| Maximum Vertical Speed | 20 mm/s |
| Temperature Range (with optional modules) | −150 °C to +600 °C |
| Dimensions (W×D×H) | 600 × 600 × 890 mm |
| Weight | 59 kg |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Type | Imported Instrument |
| Model | MiniJet Pro |
| Maximum Injection Pressure | 1200 bar |
| Compressed Air Supply Pressure (Max) | 10 bar |
| Barrel Temperature Range | Up to 400 °C |
| Mold Temperature Range | Up to 250 °C |
| Sample Mass Capacity | 3–5 g per shot |
| Control Interface | Digital LCD Controller with Parameter Storage |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Torque Rheometer |
| Model | PolyLab OS |
| Motor Bearing | Screw-driven |
| Minimum Speed | 1 rpm |
| Frequency Range | 0.1–115 rad/s |
| Maximum Speed | 250 rpm (up to 1100 rpm optional) |
| Maximum Torque | 120 mNm (dual-range: 120/400 Nm) |
| Torque Resolution | 0.01 / 0.1 Nm |
| Temperature Range | Up to 400 °C (optional 450–500 °C) |
| Heating/Cooling | Electric heating + compressed air cooling |
| Control Zones | 7–10 independent temperature zones |
| Pressure Capability | Up to 700 bar |
| Barrel Design | Modular, horizontally split |
| Screw Configurations | Single-screw (Ø19.05 mm), Conical counter-rotating twin-screw (Ø31.8/20 mm), Parallel co-rotating twin-screw (Ø16/24 mm), Banbury-type mixer (120/625 cm³ chamber volume) |
| Power Supply | 7 kW / 16 kW |
| L/D Ratios | 10:1, 25:1, 33:1 (single-screw) |
| 25 | 1 to 40:1 (twin-screw) |
| Extrusion Capacity | ~5 kg/h (polymer-dependent) |
| Compliance | DIN 1.4301 stainless steel (mixer), DIN 1.8550 nitrided steel (screws/barrels) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | PolyLab QC |
| Instrument Category | Torque Rheometer |
| Drive Bearing | Single-screw configuration |
| Minimum Speed | 1 rpm |
| Frequency Range | 1–21 rad/s |
| Maximum Speed | 200 rpm |
| Maximum Torque | 300 N·m |
| Torque Resolution | 0.1 N·m |
| Torque Accuracy | ±0.15% of full scale |
| Temperature Range | Up to 450 °C (heating via electric cartridge heaters |
| Screw Material | Nitrided stainless steel (DIN 1.8550) |
| Chamber Material | Stainless steel (DIN 1.4301) |
| Mixer Chamber Volume | 120 cm³ or 625 cm³ |
| Screw Diameter | 19.05 mm (single-screw unit) / 31.8 mm & 20 mm (conical counter-rotating twin-screw unit) |
| Screw L/D Ratio | 25 |
| Screw Length | 300 mm |
| Gear Ratio | 3:2 |
| Maximum System Pressure | 700 bar |
| Power Rating | 4 kW |
| Control Interface | USB or optional Ethernet (LAN) |
| Software Platform | HAAKE PolySoft v7.x (Windows-based) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Type | Imported |
| Model | Process 11 |
| Drive Motor Power | 1.5 kW |
| Screw Diameter | 11 mm |
| L/D Ratio | 40 |
| Speed Range | 10–1000 rpm |
| Barrel Material | Nitrided Steel 1.7365 (EN 40B) |
| Max Operating Temperature | 350 °C (optional 450 °C) |
| Max System Pressure | 100 bar (with pressure monitoring) |
| Heating Zones | 7 × 5D electric heating (optional water cooling) |
| Dimensions (L×W×H) | 820 × 480 × 410 mm |
| Weight | 55 kg |
| Sample Requirement | ~20 g |
| Throughput | up to 2.5 kg/h |
| Barrel Opening | Horizontal split, two-piece design |
| Control Interface | Integrated color touchscreen |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Country of Origin | Imported |
| Model | TSE 24 |
| Price | Upon Request |
| Screw Diameter | 24 mm |
| L/D Ratio | up to 40:1 |
| Motor Power | 5.5–11 kW |
| Max Speed | 500–1000 rpm |
| Max Temperature | 400 °C |
| Max Pressure | 100 bar |
| Temperature Zones | 7–10 independently controlled |
| Throughput | 2–30 kg/h |
| Drive Type | DC or AC servo motor |
| Barrel Construction | Horizontal split, hinged modular segments |
| Screw Design | Intermeshing co-rotating, fully configurable |
| Control Interface | 10.4" color touchscreen with HAAKE PolyLab OS software |
| Data Export | Real-time CSV/Excel export via Ethernet/USB |
| Compliance | CE, ISO 9001, compliant with GLP/GMP documentation requirements for process development |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Type | Rotational Viscometer |
| Model | VT C / VT D / VT E |
| Viscosity Range | 15 – 40,000,000 mPa·s |
| Accuracy | ±1 % FSD |
| Repeatability | 0.2 % FSD |
| Speed Range | 0.01 – 200 rpm |
| Compliance | ISO 2555, ASTM D1084/D2196/D2556/D2983/D3232, BS 6075/5350 |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Instrument Type | Rotational Viscometer |
| Model | HAAKE Viscotester D |
| Viscosity Range | 15 – 40,000,000 mPa·s |
| Compliance | ISO 2555 |
| Rotor Geometry | Standard Spindle (e.g., LV, RV, HA, HB series) |
| Shear Rate Range | Dependent on spindle geometry and rotational speed (typically 0.1–1000 s⁻¹) |
| Accuracy | ±1% of full scale (per ISO 2555 calibration requirements) |