Empowering Scientific Discovery

BUCHI Labortechnik AG

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBUCHI
OriginSwitzerland
Manufacturer TypeManufacturer
Origin CategoryImported
ModelProxiScout
Instrument TypePortable
Operating PrincipleMEMS-based Micro-Electro-Mechanical Systems NIR Spectroscopy
Wavelength Range1350–2550 nm
Scan Speed2 seconds per scan
Measurement ModeReflectance
Chemometrics SoftwareEigenVector
Weight1 kg
Ingress Protection RatingIP65
BatteryDual user-replaceable 18650 rechargeable cells
Battery Life~800 scans (2 s/scan)
Wireless ConnectivityBluetooth v4.2 BLE
Optical Spot Diameter~10 mm
Charging PortUSB-C
Typical Signal-to-Noise Ratio2000:1
Spectral Resolution16 nm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBUCHI
OriginSwitzerland
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Laboratory Instrument
ModelNIRFlex N-500
Instrument PrincipleFourier Transform (FT-NIR)
Wavelength Range10000–4000 cm⁻¹ (1000–2500 nm)
Scan Speed2–4 scans/sec
Data Sampling Interval4 cm⁻¹
Measurement ModesDiffuse Reflectance / Transmission / Transflection
Chemometrics SoftwareNIRCal
Interferometer TypeTeO₂ Wedge Polarization Interferometer
Spectral Resolution8 cm⁻¹
Wavenumber Accuracy±0.2 cm⁻¹
SNR10,000 (at 16 scans)
DetectorTemperature-Controlled InGaAs
A/D Converter24-bit
Light Source Lifetime12,000 h (dual tungsten halogen lamps)
Dimensions450 × 550 × 250 mm
Weight25 kg
Operating Environment5–35 °C, RH < 80% at ≤31 °C (derating to 67% at 35 °C), altitude ≤2500 m
Power Supply100–230 V ±10%, 50/60 Hz, <350 W
Communication InterfaceEthernet (TCP/IP), 100 Mbit/s
IP RatingIP20
Pollution Degree2
Overvoltage CategoryII
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBUCHI
OriginSwitzerland
ManufacturerBUCHI AG
Instrument TypeAutomated Kjeldahl Nitrogen Determinator
Recovery Rate≥99.5%
Power Consumption2100 W
Dimensions (L×W×H)320 × 400 × 730 mm
Weight23 kg
Electrical Supply220–240 VAC ±10%, 50/60 Hz
Safety CertificationsCE, CSA
RepeatabilityRSD <0.8%
Nitrogen Detection Range0.02–220 mg N
Cooling Water ManagementIntelligent Flow Control with Auto-Shutoff
Steam Power ControlAdjustable 10–100%, Programmable Steam Gradient
Safety SystemsDual-flow cooling water sensor, steam generator pressure monitoring, sample tube presence detection, transparent safety shield with interlock, reagent/waste/water level sensing
Voltage StabilizationIntegrated line regulator for consistent steam output
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBUCHI
OriginSwitzerland
ManufacturerBUCHI AG
Product TypeAutomated Kjeldahl Nitrogen Determinator
ModelK-375
Nitrogen Range0.02–200 mg N
Distillation Time1–9999 min (typical: 4 min/sample)
RepeatabilityRSD ≤ 1%
Sample Weight Capacity≤ 5 g (solid), ≤ 200 mL (liquid)
Nitrogen Recovery Rate≥ 99.5%
Max Power Consumption2.4 kW
Dimensions (L×W×H)458 × 670 × 431 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBUCHI
OriginSwitzerland
ManufacturerBUCHI AG
Product TypeImported Instrument
ModelPure C-815 / Pure C-810
Application LevelLaboratory Grade
Instrument CategoryLow-to-Medium Pressure Preparative LC
Flow Rate Range1–250 mL/min
Flow Accuracy±3% RSD
Flow Precision±0.5% RSD
Maximum Operating Pressure50 bar
Wavelength Accuracy±1 nm
Wavelength Repeatability0.4 nm
Baseline Noise5 × 10⁻⁵ AU
Data Acquisition Rate5 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBUCHI
OriginSwitzerland
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Instrument TypePreparative SFC System
ModelSFC-250
Flow Rate Range0–250 mL/min (including up to 40% modifier)
Maximum Operating Pressure400 bar (CO₂ and modifier pumps)
Detector OptionsDiode Array Detector (DAD), Mass Spectrometer (MS), Evaporative Light Scattering Detector (ELSD)
Modifier Channels4
Injection Loop Volume2.5 mL
Column CapacityUp to 10 columns (2 mounted simultaneously)
Column DimensionsID 15–30 mm, max. length 250 mm
Column Oven Temperature RangeAmbient to 70 °C
Gradient CapabilityIsocratic, binary linear, or step gradients
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBUCHI
OriginSwitzerland
ManufacturerBUCHI AG
Instrument TypePreparative SFC System
ModelSFC-50
Flow Rate Range1–50 mL/min (including up to 40% modifier)
Maximum Pressure400 bar
Detector OptionsDAD, ELSD, Mass Spectrometer (MS)
Column CapacityUp to 10 columns (2 mounted simultaneously)
Column DimensionsID 4–16 mm, max. length 250 mm
Column Oven Temperature RangeAmbient to 70 °C
UV Wavelength Range (DAD)190–720 nm
Power Supply230 V ±10%, 50/60 Hz
Operating Environment15–25 °C, 45–75% RH
Dimensions (W×D×H)560 × 600 × 880 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBUCHI
OriginSwitzerland
ManufacturerBUCHI AG
Instrument TypeBenchtop FT-NIR Spectrometer
ModelNIRMaster
Spectral Range10000–4000 cm⁻¹
Resolution8 cm⁻¹
Scan Speed2–4 scans/sec
Data Sampling Interval4 cm⁻¹
Measurement ModesDiffuse Reflectance / Transflectance
Interferometer TypePolarization Interferometer
Wavenumber Accuracy±0.2 cm⁻¹
SNR10,000 (peak-to-peak, baseline-corrected, 5600–6000 cm⁻¹)
DetectorThermoelectrically Cooled Extended-Range InGaAs
Light SourceDual Halogen Lamp Module (MTBF: 12,000 h)
LaserHeNe, 632.992 nm
Operating Temperature5–35 °C
Relative Humidity<80% at ≤31 °C (linearly decreasing to 67% at 35 °C)
Power Supply100–240 VAC ±10%, 50/60 Hz, 150 W
Enclosure MaterialFood-Grade PMMA or Stainless Steel
IP RatingIP54 (optional IP65)
Dimensions (W×H×D)360 × 420 × 540 mm
Weight~43 kg (NIRMaster), ~49 kg (NIRMaster Pro)
Chemometrics SoftwareNIRCal
Sample HandlingEasy-Spin magnetic rotation stage for heterogeneous samples
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBUCHI
OriginSwitzerland
ManufacturerBUCHI AG
Product TypeImported Instrument
ModelPure C-835 / Pure C-830
Application LevelLaboratory Grade
Instrument CategoryHigh-Pressure Preparative Liquid Chromatography
Flow Rate Range1–100 mL/min
Flow Accuracy±3% RSD
Flow Precision±0.5% RSD
Maximum Pressure300 bar
Wavelength Accuracy±1 nm
Wavelength Reproducibility0.4 nm
Baseline Noise5 × 10⁻⁵ AU
Data Acquisition Frequency5 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBUCHI
OriginSwitzerland
Manufacturer TypeManufacturer
Origin CategoryImported
ModelProxiMate
Instrument TypeLaboratory
Measurement PrincipleGrating-based non-scanning spectrometer with diode array detector
Wavelength Range400–1700 nm
Scan Speed10 ms
Data Sampling Interval10 nm (visible), 7 nm (NIR)
Measurement ModeDiffuse Reflectance
Chemometrics SoftwareAutocal
IP RatingIP69
Weight23 kg
Dimensions (W × D × H)260 × 435 × 500 mm
Power Consumption60 W
Operating Frequency50/60 Hz
Operating Temperature5–40 °C
Relative Humidity≤80 % (at ≤31 °C)
Storage Temperature≤45 °C
Altitude Limit≤2000 m
Measurement TimeConfigurable, default 15 s
Optical Configuration OptionsStandard NIR only
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBUCHI
OriginSwitzerland
ManufacturerBUCHI AG
TypeImported Instrument
ModelK-446 / K-449
Power2300 W
Heating Positions20
Temperature Range30–450 °C
Temperature Accuracy±1 °C
DisplayLCD
Automation LevelSemi-Automatic (K-446) / Fully Automatic (K-449)
Acid Vapor ContainmentIntegrated Sealed Block Design
Sample Tube MaterialHigh-Purity Borosilicate Glass (BUCHI Certified)
Safety FeaturesDual Temperature Limiting per Stage
User InterfaceProgrammable Multi-Stage Temperature Profiles with Countdown Timer and Real-Time Temperature Feedback
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBUCHI
OriginSwitzerland
ManufacturerBUCHI AG
Product TypeImported Instrument
ModelPure C-850
Application LevelLaboratory Grade
Instrument CategoryHigh-Pressure Preparative LC System
Flow Rate Range1–250 mL/min
Flow AccuracyRSD < 3%
Flow PrecisionRSD < 0.5%
Maximum Pressure300 bar
Wavelength Range±2 nm (200–800 nm)
Wavelength Repeatability0.4 nm
Baseline Noise3 × 10⁻⁵ AU
Data Acquisition Frequency5 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBUCHI
OriginSwitzerland
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Instrument
ModelSFC-660
Instrument TypePreparative
Flow Rate Range0–660 mL/min (including up to 40% modifier)
Maximum Operating Pressure400 bar
Detector OptionsDiode Array Detector (DAD), Electrospray Light Scattering Detector (ELSD), Mass Spectrometer (MS)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBUCHI
OriginGermany
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Instrument
ModelX-One (One-Six)
Instrument TypeIn-line
Operating PrincipleReal-time in-process spectroscopy with fiber-optic coupling
Wavelength Range900–1700 nm (standard advanced configuration)
optional dual-range350–920 nm (VIS) and 950–1750 nm (NIR)
Scan Rate100 spectra per second
Spectral Sampling Interval3.2 nm
Measurement ModesDiffuse Reflectance / Transmission
Chemometrics SoftwareSX-Plus
DetectorDiode Array
Optical Spot Diameter30–40 mm
Imaging SystemIntegrated HD CCD camera, 80 µm spatial resolution in visible range
Light SourceDual tungsten-halogen lamps, MTBF 18,000 h (2 × 9,000 h)
Environmental RatingIP65/IP67
Explosion-Proof OptionATEX/IECEx certified (Ex II 1/2D ta tb IIIC T80°C
Dimensions (W×D×H)220 × 220 × 135 mm
Weight6–7 kg
Operating Temperature−10°C to +70°C
Ambient Temperature Range−10°C to +40°C
Relative Humidity<90% RH, non-condensing
Vibration Resistance0.2 g (0.1–150 Hz)
Process Interface Pressure Rating30 bar at flange mounting point
Power Supply110/220 V AC ±20%, 50/60 Hz, 30 W
Housing MaterialNickel-plated stainless steel, aluminum heat sink, NBR sealing
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBUCHI
OriginSwitzerland
ManufacturerBUCHI AG
Product TypeAutomated Sample Handler (KjelSampler)
ModelK-376 / K-377
Instrument CategoryKjeldahl Nitrogen Analyzer Accessory
Nitrogen Determination Range0.02 – 200 mg N
Distillation Time per Sample≤240 s
RepeatabilityRSD < 1 %
Sample Weight CapacitySolids ≤ 5 g, Liquids ≤ 200 mL
Nitrogen Recovery Rate>99.5 % (for 1–200 mg N)
Power Consumption150 W
Dimensions (L×W×H)505 × 750 × 655 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBUCHI
OriginSwitzerland
Manufacturer TypeDirect Manufacturer
Origin CategoryImported
ModelPure Essential System
Application LevelLaboratory Grade
Instrument TypeMedium-to-Low Pressure Preparative LC
Flow Rate Range0–300 mL/min
Flow Accuracy±1%
Flow Precision±1% at 5–250 mL/min
Maximum Pressure50 bar
UV Wavelength OptionsFixed wavelengths at 254, 275, 325, and 365 nm