- All
- Favorite
- Popular
- Most rated
| Brand | Freeland / csfriend |
|---|---|
| Origin | Hunan, China |
| Model | FDH-0171 |
| Power Supply | AC 220 V ±10% |
| Heating Power | 2500 W |
| Pressure Sensor Range | 0–1.6 MPa, Accuracy: ±0.2% FS |
| Oil Bath Temperature Range | Ambient to 200.0 °C (adjustable), Typical Test Temp: 150.0 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Dual-Bomb Configuration | Yes |
| Rotation Speed | 100 ±5 rpm |
| Bomb Tilt Angle | 30° from Horizontal |
| Oil Bath Volume | 30 L |
| Dimensions (W×D×H) | 664 × 574 × 920 mm |
| Weight | ~45 kg |
| Brand | csfriend (Fulande) |
|---|---|
| Origin | Hunan, China |
| Model | FDH-1702 |
| Standard Compliance | SH/T 0059 |
| Sample Mass | 65 g |
| Heating Method | Metal Bath |
| Temperature Control | 250 ± 0.5 °C |
| Timer Accuracy | 3600 s ± 0.1 s |
| Pressure Measurement | 20 mm H₂O ± 0.2 mm H₂O |
| Power Supply | AC 220 V ± 10 %, 50 Hz |
| Input Power | 1.4 kVA |
| Operating Ambient | 15–35 °C |
| Temperature Controller | Intelligent Programmable PID Controller |
| Heating Time to Setpoint | ~60 min |
| Sensor Type | Pt100 Resistance Thermometer |
| Vacuum System | Integrated Low-Noise Self-Developed Vacuum Module |
| Brand | Fluoride (csfriend) |
|---|---|
| Origin | Hunan, China |
| Model | FDY-0801 |
| Liquid Flow Rate | 1.3–1.6 L/s |
| Temperature Control | 88 °C ±3 °C |
| Test Duration | 1064 h |
| Heating Power | 2.6 kW |
| Motor Power | 2.2 kW |
| System Pressure Range | 80–103 kPa |
| Total Power Consumption | 4.8 kW |
| Supply Voltage | AC 380 V ±10%, 50 Hz |
| Net Weight | 180 kg |
| Brand | Fluoride (csfriend) |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | FDH-1906 |
| Product Category | Laboratory Instrument |
| Input Voltage | AC 220 V ±10%, 50 Hz |
| Input Power | 2 kW |
| Temperature Control Range | Ambient to 200 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Timing Range | 0–100 h |
| Brand | Fuland (csfriend) |
|---|---|
| Origin | Hunan, China |
| Model | FDY-0808 |
| Application Category | Laboratory Instrument for EV Thermal Management Fluid Evaluation |
| Compliance Standard | GB/T 29743.2 Annex C |
| Temperature Range | 0–100 °C (±1 °C accuracy) |
| Flow Rate | ≥30 L/min (adjustable, resolution 0.1 L/min) |
| Pressure Range | 0–500 kPa |
| Maximum Runtime | 9999 h (programmable, supports 1064 h continuous test cycles) |
| Data Storage Capacity | >200 test records |
| Pump Type | High-Temperature Automotive Electronic Water Pump (head ≥11 m, inlet/outlet diameter 20 mm) |
| Test Components | Aluminum Battery Cold Plate (≥1 m²), Aluminum Motor Housing with Integrated Cooling Channels, Aluminum Electronic Control Cooling Module |
| Fluid Path Material | Stainless Steel Fittings with Visual Observation Window |
| Thermal Insulation | Multi-layer External Jacket (reduces surface temperature & external thermal radiation) |
| Brand | FlanD / csfriend |
|---|---|
| Origin | Hunan, China |
| Model | FDH-1502 |
| Applicable Standards | GB/T 9171, ASTM D4684, SH/T 0562 |
| Temperature Range | –50 °C to +80 °C |
| Sample Capacity | 9-position test block |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Cooling System | Imported compressor-based refrigeration unit |
| Detection Method | Optical encoder-based rotor speed measurement |
| Control Interface | Touchscreen with bilingual (English/Chinese) OS |
| Software | FLD proprietary BPT analysis software with real-time timing, auto-diagnosis, and single-point calibration capability |
| Optional Feature | Integrated nitrogen purge port |
| Design | Integrated monolithic chassis |
| Brand | Fuland (CSFriend) |
|---|---|
| Model | FDH-8461 |
| Application | HTHS viscosity measurement of lubricating oils |
| Standard Compliance | ASTM D5481, SH/T 0703 |
| Temperature Range | Ambient to 150 °C |
| HTHS Viscosity Range | 0.5–8 mPa·s at 150 °C |
| Pressure Control Range | 3.5–35 kgf/cm² |
| Sample Volume | 10 mL |
| Pressure Display | Digital pressure gauge |
| Time Measurement | Digital timer |
| Control Method | Integrated microprocessor-based PID temperature & pressure regulation |
| Power Supply | AC 220 V, 50 Hz |
| Safety | FTC thermal cut-off circuit |
| Sample Handling | Individual stopcock valve per capillary cell |