- All
- Favorite
- Popular
- Most rated
| Brand | Fuland (csfriend) |
|---|---|
| Model | FDR-4171 |
| Origin | Hunan, China |
| Compliance Standard | GB/T 30963 |
| Temperature Control Method | Microcomputer-controlled bath & sample temperature |
| Stirring Method | Automatic mechanical stirring |
| Data Output | On-screen real-time crystallization curve + thermal profile display, storage and thermal printer output |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Rated Power | 1 kW |
| Operating Environment | 0–45 °C, RH <80% |
| Heating Element | Dry-burn-resistant electric heating tube |
| Brand | Flanland / csfriend |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | FDY-1301 |
| Operating Pressure | 7 MPa ± 0.3 MPa |
| Temperature Range | 20–150 °C ± 2 °C |
| Stroke Frequency | 1000 cycles/h |
| Total Cycle Capacity | 85,000 cycles |
| Cooling Method | Hermetic Compressor-Based Air-Circulation System |
| Heating Method | Non-Radiative Resistive Heating |
| Temperature Sensor | PT100 Platinum RTD |
| Control System | Microprocessor-Based PID Controller with Digital Display |
| Pressure Regulation | Precision Pressure-Regulating Valve |
| Pressure Indication | Analog Precision Pressure Gauge |
| Stroke Monitoring | Digital Linear Displacement Rate Display with Adjustable Actuation Mechanism |
| Compliance Standard | ISO 4925-2 |
| Brand | Furand (csfriend) |
|---|---|
| Model | FDR-2271 |
| Instrument Class | 0.05 |
| pH Range | 0.00–14.00 pH |
| mV Range | −1800.0 to +1800.0 mV |
| Temperature Range | −5.0 to 105.0 °C |
| pH Resolution | 0.01 pH |
| mV Resolution | 0.1 mV |
| Temperature Resolution | 0.1 °C |
| pH Accuracy | ±0.01 pH ±1 digit |
| mV Accuracy | ±0.03% FS |
| Temperature Accuracy | ±0.3 °C ±1 digit |
| Burette Capacity Tolerance | ±0.025 mL (10 mL), ±0.035 mL (20 mL) |
| Burette Resolution | 1/10000 (10 mL), 2/10000 (20 mL) |
| Burette Fill/Dispense Time | 50 ±10 s (full scale) |
| Repeatability | 0.2% RSD |
| Endpoint Detection Sensitivity | ±2 mV |
| Drift Stability | ±0.3 mV ±1 digit / 3 h |
| Power Supply | AC 220 V ±10%, 50 Hz ±1 Hz |
| Dimensions (W×D×H) | 340 × 400 × 400 mm |
| Weight | 10 kg |
| Brand | Fland (csfriend) |
|---|---|
| Origin | Hunan, China |
| Model | FDR-0871 |
| Temperature Range | 0–400 °C |
| Temperature Accuracy | ±0.1 °C |
| Cold Bath Range | −10 to 80 °C |
| Distillation Rate | 4–5 mL/min |
| Volume Measurement Range | 1–100 mL |
| Volume Resolution | 0.1 mL |
| Heating Power | 2 kW |
| Refrigeration Power | 1 kW |
| Refrigeration Control Accuracy | ±1 °C |
| Steam Temperature Sensor Range | 0–400 °C |
| Furnace Temperature Sensor Range | 0–500 °C |
| Refrigeration Sensor Range | 0–100 °C |
| Brand | FlanD / csfriend |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | FDH-2801 |
| Pricing | Upon Request |
| Standard Compliance | ISO 9950, JB/T 7951, SH/T 0220 |
| Temperature Range | 0–900 °C |
| Sampling Rate | 260 Hz |
| Probe Material | Inconel 600 (Ni–Cr–Fe alloy) |
| Probe Dimensions | Ø12.5 mm × 60 mm |
| Data Output | Dual-curve display (cooling curve + cooling rate curve), 5-group comparative analysis |
| Interface | USB, RS-232, LIMS-compatible |
| Control System | Integrated FlanD Automatic Control Module |
| Software Environment | Windows XP and later (32-bit) |
| Data Management | Folder-based archival with auto-timestamped files (date/time embedded in metadata) |
| Correction | User-configurable probe correction coefficient (based on peak cooling rate or full-curve fitting) |
| Reporting | A4/B5 formatted printouts including cooling parameters (e.g., time to 700 °C, 300 °C |
| Brand | FuLand / csfriend |
|---|---|
| Measurement Range | 2–100 mN/m (for insulating oils) |
| Sensitivity | 0.1 mN/m |
| Repeatability | ±0.3% |
| Accuracy | ±0.1 mN/m |
| Resolution | 0.1 mN/m |
| Power Consumption | 20 VA |
| Operating Temperature | 10–30 °C (typical at 25 °C) |
| Relative Humidity | 20–75 %RH |
| Supply Voltage | AC 220 V ±5%, 50 Hz |
| Net Weight | 15 kg |
| Microcontroller Architecture | High-Capacity Embedded MCU |
| Display | Full-Color LCD Touchscreen Interface |
| Data Handling | Auto-calibration via multi-point linear regression (mg = f(Δ-result)), real-time clock, non-volatile memory backup, auto-lift mechanism, integrated thermal printer |
| Brand | Freeland / csfriend |
|---|---|
| Origin | Hunan, China |
| Model | FDH-0171 |
| Power Supply | AC 220 V ±10% |
| Heating Power | 2500 W |
| Pressure Sensor Range | 0–1.6 MPa, Accuracy: ±0.2% FS |
| Oil Bath Temperature Range | Ambient to 200.0 °C (adjustable), Typical Test Temp: 150.0 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Dual-Bomb Configuration | Yes |
| Rotation Speed | 100 ±5 rpm |
| Bomb Tilt Angle | 30° from Horizontal |
| Oil Bath Volume | 30 L |
| Dimensions (W×D×H) | 664 × 574 × 920 mm |
| Weight | ~45 kg |
| Brand | Fulande (csfriend) |
|---|---|
| Model | FDR-4371 |
| Origin | Hunan, China |
| Display | 7-inch color LCD touchscreen |
| Distillation Rate | 4–5 mL/min |
| Cold Bath Temperature Range | −10 to +70 °C |
| Heating Temperature Range | Ambient to +400 °C, Resolution: 0.1 °C |
| Volume Detection Range | 0–100 mL, Resolution: 0.1 mL |
| Power Supply | AC 220 V, 50 Hz, 1.5 kW |
| Operating Environment | 0–60 °C, RH ≤ 80% |
| Detection System | Imported XEC infrared cylinder reading sensor |
| Tracking System | HP precision linear tracking mechanism, positional resolution: 0.1 mL |
| Compliance | Designed to support ASTM D86, ASTM D1078, ISO 3405, and GB/T 6536 methodologies |
| Brand | csfriend (Fulande) |
|---|---|
| Origin | Hunan, China |
| Model | FDH-1702 |
| Standard Compliance | SH/T 0059 |
| Sample Mass | 65 g |
| Heating Method | Metal Bath |
| Temperature Control | 250 ± 0.5 °C |
| Timer Accuracy | 3600 s ± 0.1 s |
| Pressure Measurement | 20 mm H₂O ± 0.2 mm H₂O |
| Power Supply | AC 220 V ± 10 %, 50 Hz |
| Input Power | 1.4 kVA |
| Operating Ambient | 15–35 °C |
| Temperature Controller | Intelligent Programmable PID Controller |
| Heating Time to Setpoint | ~60 min |
| Sensor Type | Pt100 Resistance Thermometer |
| Vacuum System | Integrated Low-Noise Self-Developed Vacuum Module |
| Brand | Brookfield (csfriend OEM) |
|---|---|
| Origin | Hunan, China |
| Model | FDH-3901 |
| Temperature Control Range | Ambient to 100 °C |
| Temperature Accuracy | ±1 °C |
| Spray Flow Rate | 5.0 ±0.5 mL/s |
| Bearing Speed | 600 ±30 rpm |
| Bearing Type | ISO 204 Deep Groove Ball Bearing |
| Input Power | <1000 W |
| Brand | CSFriend |
|---|---|
| Origin | Hunan, China |
| Model | FDH-5901 |
| Cooling Method | Compressor-based refrigeration |
| Heating Method | Electric heating tube |
| Temperature Control | Digital PID controller |
| Temperature Range | 0–60 °C |
| Timing System | Digital timer |
| Power Supply | AC 220 V |
| Brand | CSFriend / Fuland |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | FDR-2801 |
| Vacuum Degree | 80 kPa |
| Filtration Method | Vacuum-assisted suction |
| Power Consumption | 500 W |
| Power Supply | AC 220 V / 50 Hz |
| Timer | Digital display with audible alarm |
| Noise Level | Low-noise vacuum pump |
| Construction | Stainless steel chassis with ceramic-coated control panel |
| Clamping Mechanism | Precision die-stamped metal clamps |
| Glassware Set | ASTM-compliant standard filtration glassware |
| Configuration | Single-station benchtop filtration system |
| Brand | CSFriend |
|---|---|
| Origin | Hunan, China |
| Model | FDR-2601 |
| Temperature Control | 60 ± 1 °C |
| Measurement Principle | Potentiometric Titration |
| pH Range | 0.00–14.00 pH |
| mV Range | −1800.0 to +1800.0 mV |
| Temperature Range | −5.0 to 105.0 °C |
| pH Resolution | 0.01 pH |
| mV Resolution | 0.1 mV |
| Temperature Resolution | 0.1 °C |
| pH Accuracy | ±0.01 pH ± 1 digit |
| mV Accuracy | ±0.03 % FS |
| Temperature Accuracy | ±0.3 °C ± 1 digit |
| Burette Capacity Tolerance | ±0.025 mL (10 mL), ±0.035 mL (20 mL) |
| Burette Resolution | 1/10000 (10 mL), 2/10000 (20 mL) |
| Titration Repeatability | 0.2 % |
| Endpoint Detection Sensitivity | ±2 mV |
| Drift Stability | (±0.3 mV ± 1 digit) / 3 h |
| Power Supply | AC 220 ± 22 V, 50 ± 1 Hz |
| Dimensions (W×D×H) | 340 × 400 × 400 mm |
| Weight | 10 kg |
| Brand | FuLand / csfriend |
|---|---|
| Origin | Hunan, China |
| Model | Compliant with GB/T 5096 |
| Temperature Range | Ambient to 150 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Heating Power | 1200 W |
| Display | LCD (English/Chinese) |
| Test Stations | 6 |
| Diagnostic Function | Built-in Self-Diagnosis & Auto-Tuning Capability |
| Oxygen Bomb Storage Compartment | Integrated |
| Brand | Fland (csfriend) |
|---|---|
| Model | FDR-0571 |
| Standard Compliance | GB/T 8019 |
| Temperature Range | Ambient to 200 °C |
| Temperature Resolution | 0.01 °C |
| Display | 7-inch Touchscreen (Chinese/English Optional) |
| Weighing Precision | 0.0001 g (Integrated METTLER Toledo Analytical Balance) |
| Power Supply | 220 V, 50 Hz |
| Data Export Interface | Optional RS232/USB for LIMS Integration |
| Brand | Fluoride (csfriend) |
|---|---|
| Origin | Hunan, China |
| Model | FDY-0801 |
| Liquid Flow Rate | 1.3–1.6 L/s |
| Temperature Control | 88 °C ±3 °C |
| Test Duration | 1064 h |
| Heating Power | 2.6 kW |
| Motor Power | 2.2 kW |
| System Pressure Range | 80–103 kPa |
| Total Power Consumption | 4.8 kW |
| Supply Voltage | AC 380 V ±10%, 50 Hz |
| Net Weight | 180 kg |
| Brand | CSFriend |
|---|---|
| Origin | Hunan, China |
| Model | FDT-0234 |
| Flash Point Range | -30 °C to 50 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Measurement Precision | < 2 °C |
| Sample Volume | 2 mL (liquid), 4 mL (solid/semi-solid) |
| Ignition Method | Electronic spark igniter |
| Cooling System | Peltier thermoelectric cooling with external chilled water circulation |
| Power Supply | AC 220 V ±10 %, 50 Hz |
| Max. Power Consumption | ≤300 W |
| Operating Ambient | 5–30 °C, 30–80 % RH |
| Compliance | GB/T 5208 (Rapid Equilibrium Closed-Cup Method) |
| Brand | Fland / csfriend |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | FDS-0411 |
| Power Consumption | 1000 W |
| Supply Voltage | AC 220 V, 50 Hz |
| Temperature Control | Digital PID Controller with Auto-Tuning |
| Gas Flow Regulation | Adjustable Needle Valve with Precision Flowmeter |
| Heating Method | Immersed Electric Heating Element |
| Compliant Standards | ASTM D2420, SH/T 0125 |
| Brand | Fland (csfriend) |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | FDR-4291 |
| Pricing | Available Upon Request |
| Measurement Principle | Dual-channel NDIR (Non-Dispersive Infrared) Spectroscopy |
| Gas Components Measured | CH₄ (0–100% vol), CnHm (0–10% vol) |
| Resolution | 0.01% for both CH₄ and CnHm |
| Accuracy | ±1% FS for both channels |
| Zero Calibration | Automatic via integrated sampling pump |
| Display | 320 × 240 graphical LCD |
| Output Interface | RS232 digital serial port |
| Brand | Brookfield |
|---|---|
| Model | FDH-3201 |
| Temperature Control | ±0.1 °C at 150 °C |
| Temperature Range | 150 °C (fixed setpoint) |
| Heating Method | Oil bath with stainless steel heater |
| Bath Vessel | Borosilicate glass cylinder, Φ300 × 450 mm |
| Air Flow Control | Precision mass flow meter |
| Sample Stations | Dual-tube configuration |
| Power Supply | AC 220 V / 50 Hz |
| Total Power | 2.5 kW |
| Temperature Sensor | Pt100 RTD |
| Controller | Microprocessor-based PID with digital display |
| Air Filtration | Glass wool–packed filter |
| Insulation | High-efficiency thermal insulation |
| Compliance | ASTM D6082, ISO 6247, IP 146 |
| Brand | Brookfield (csfriend OEM) |
|---|---|
| Model | FDH-4301 |
| Temperature Range | Ambient to –35 °C ±0.5 °C |
| Temperature Control | PID digital microprocessor controller |
| Bath Material | Stainless steel |
| Cooling System | Hermetically sealed compressor-based refrigeration |
| Circulation | Magnetic-drive recirculating pump |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Design | Modular split-body configuration |
| Capillary Viscometer Type | Ubbelohde or Cannon-Fenske compliant (standardized for grease similarity testing per ASTM D1092) |
| Brand | Flanland (csfriend) |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | FDH-1601 |
| Cooling Method | Dual-stage imported compressors with eco-friendly refrigerant |
| Temperature Control | PID digital controller |
| Setpoint Accuracy | −60 °C ± 0.1 °C |
| Bath Construction | Double-walled stainless steel immersion bath with integrated heat transfer medium |
| Timing System | Digital timer |
| Accessories | Dedicated groove-scraping blade and ergonomic lifting tool |
| Brand | Fulande (csfriend) |
|---|---|
| Model | FDR-4571 |
| Origin | Hunan, China |
| Display | LCD screen |
| Distillation Rate | 4–5 mL/min |
| Cold Bath Temperature Range | −10 to +70 °C |
| Heating Temperature Range | Ambient to +350 °C |
| Temperature Resolution | 0.1 °C |
| Volume Detection Range | 0–100 mL |
| Volume Resolution | 0.1 mL |
| Temperature Sensor | Imported German probe |
| Power Supply | AC 220 V, 50 Hz |
| Total Power Consumption | 1.5 kW |
| Operating Environment | 0–60 °C, ≤80% RH |
| Brand | Fluoride (csfriend) |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | FDH-1906 |
| Product Category | Laboratory Instrument |
| Input Voltage | AC 220 V ±10%, 50 Hz |
| Input Power | 2 kW |
| Temperature Control Range | Ambient to 200 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Timing Range | 0–100 h |