Chemical Analysis Instruments
Filter
Showing 3991–4020 of 4194 results
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | TUV755B |
| Optical System | Dual-beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.1 nm |
| Spectral Bandwidth | 1 nm |
| Stray Light | ≤0.03% (at 220 nm, using NaI solution) |
| Wavelength Scanning Mode | Automatic |
| Data Interface | RS-232 & Standard Parallel Printer Port |
| Onboard Storage | Microprocessor-based memory for calibration curves and measurement data |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | UV752 |
| Optical System | Single-beam |
| Detector | Photodiode Array |
| Wavelength Range | 200–1000 nm |
| Wavelength Accuracy | ±2 nm |
| Wavelength Repeatability | ≤1 nm |
| Spectral Bandwidth | 2 nm |
| Stray Light | ≤0.5% (at 220 nm, using NaI solution) |
| Display | Digital LED/LCD readout |
| Sample Compartment | Accommodates cuvettes from 5 mm to 100 mm pathlength |
| Automation Level | Manual wavelength selection |
| Key Components | Imported optical and electronic components |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | UV752N |
| Optical System | Czerny-Turner monochromator with 1200 lines/mm grating |
| Beam Type | Single-beam |
| Detector | Photodiode array |
| Wavelength Range | 195–1020 nm |
| Wavelength Accuracy | ±2 nm |
| Wavelength Repeatability | ≤1 nm |
| Spectral Bandwidth | 2 nm (stated in specs) / 5 nm (in parameter list — reconciled as 2 nm per primary spec sheet |
| Stray Light | ≤0.3%T at 220 nm (NaI) |
| Photometric Accuracy | ±0.5%T |
| Photometric Repeatability | ±0.2%T |
| Photometric Range | 0–200%T, –3 to +3 A |
| Baseline Drift | ±0.004 A/h at 500 nm |
| Noise | ≤0.3%T (RMS) |
| Wavelength Drive | Manual |
| Display | 4-digit LED |
| Lamp Source | Imported deuterium lamp (UV) and tungsten-halogen lamp (VIS-NIR) |
| Lamp Switching | Automatic |
| Sample Compartment | Accommodates 5–100 mm pathlength cuvettes |
| Interface | Parallel port for optional thermal printer |
| Net Weight | 12 kg |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | UV754N |
| Optical System | Single-beam |
| Detector Type | Photodiode Array |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±2 nm |
| Wavelength Repeatability | 0.5 nm |
| Spectral Bandwidth | 4 nm |
| Stray Light | ≤0.3% T at 220 nm and 360 nm |
| Automation Level | Automatic Wavelength Scanning |
| Data Storage | Onboard Microcontroller (51-series) with Curve & Measurement Memory |
| Compliance | Designed for GLP-supporting labs |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | UV754PC |
| Optical System | Czerny-Turner monochromator with 1200 lines/mm grating |
| Beam Type | Single-beam |
| Detector | Photodiode array |
| Wavelength Range | 190–1100 nm |
| Spectral Bandwidth | 2 nm |
| Wavelength Accuracy | ±2 nm |
| Wavelength Repeatability | ≤1 nm |
| Stray Light | ≤0.5% T (at 220 nm, using NaI) |
| Photometric Accuracy | ±0.3% T |
| Photometric Repeatability | 0.3% T |
| Baseline Stability | ±0.004 A/h (at 500 nm, after 1 h warm-up) |
| Absorbance Range | 0–1.999 A |
| Transmittance Range | 0–199.0% T |
| Concentration Range | 0–1999 C |
| Display | 4-digit LCD |
| Interface | RS-232C serial port |
| Light Sources | 6 V/10 W halogen lamp (Philips) and long-life deuterium lamp |
| Power Supply | 220/110 V AC, 50–60 Hz |
| Brand | Yokogawa |
|---|---|
| Model | AQ6370D |
| Wavelength Range | 600–1700 nm |
| Wavelength Accuracy | ±0.01 nm |
| Wavelength Resolution | 0.02 nm |
| Dynamic Range | 78 dB (typ.) |
| Power Range | +20 to −90 dBm |
| Sweep Time | 0.2 s (for 100 nm span) |
| Fiber Compatibility | Single-mode and multimode fiber |
| Origin | Japan (manufactured in Yokogawa facilities |
| Brand | Youyunpu |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic Flame Photometer |
| Model | YP-32 |
| Price | USD 1,450 (FOB Qingdao) |
| Brand | Youyunpu |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | YP-CWF2 |
| Wavelength Range | 230 nm, 260 nm, 280 nm |
| Sample Volume | 0.5–2 µL |
| Optical Path Lengths | 0.04 mm, 0.2 mm, 1.0 mm |
| Light Source | Pulsed Xenon Lamp |
| Detector | UV-Enhanced CMOS Linear Array Sensor |
| DNA Quantitation Range (dsDNA) | 25–11,000 ng/µL |
| Absorbance Accuracy | ±1% (7.332 Abs @ 260 nm) |
| Absorbance Precision | 0.003 Abs (0.2 mm path) |
| Absorbance Range | 0.5–220 A |
| Measurement Time | <6 s |
| OD600 Range | 0–6 Abs |
| OD600 Repeatability & Stability | ≤0.5% (0–3 Abs), ≤2% (3–4 Abs) |
| Fluorescence Detection LOD | 0.5 pg/µL (dsDNA, with compatible dyes) |
| Fluorescence Linearity | R² > 0.995 |
| Fluorescence CV | <1.5% |
| Internal Storage | Up to 100,000 records |
| Battery | 21.6 V / 7000 mAh (8 h runtime) |
| Power Consumption | 25 W (10 W standby) |
| Dimensions | 325 × 227 × 211 mm |
| Weight | 5.15 kg |
| Brand | Youyunpu |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | YP-DYS2 |
| Price | USD 2,350 (FOB Qingdao) |
| Brand | Youyunpu |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | YP-EU Series |
| Spectral Range | 190–1020 nm |
| Spectral Bandwidth | 4 nm |
| Wavelength Accuracy | ±1.0 nm |
| Wavelength Repeatability | ≤0.5 nm |
| Photometric Accuracy | ±0.002 A (0–0.5 A), ±0.004 A (0.5–1.0 A), ±0.3% T (0–100% T) |
| Baseline Drift | ≤0.002 A/h (at 500 nm, 0 A) |
| Baseline Flatness | ±0.003 A |
| Brand | YSI |
|---|---|
| Origin | USA |
| Model | EC300A |
| Portability | Portable |
| Application Environment | Laboratory & Field |
| Conductivity Range | 0–200 mS/cm |
| TDS Range | 0–100 g/L |
| Resistivity Range | 0–10 MΩ·cm |
| Salinity Range | 0–70 ppt |
| Temperature Range | −10°C to +90°C |
| Conductivity Accuracy | ±1% FS (full-scale) or ±1% reading + offset per range |
| Temperature Accuracy | ±0.2°C or ±0.4% of range (whichever is greater) |
| Conductivity Resolution | 0.01 μS/cm (lowest range), 0.1 mS/cm (highest range) |
| Temperature Resolution | 0.1°C |
| Probe Type | Stable 4-electrode conductivity cell |
| Waterproof Rating | IP65 (instrument body) |
| Power Supply | One 9V alkaline battery (≈150 h typical life) |
| Dimensions | 18.6 × 7.0 × 3.7 cm |
| Weight | 430 g (with battery) |
| Warranty | 1 year limited warranty on instrument, probe, and cable |
| Brand | YST (Dalian Yist) |
|---|---|
| Origin | Liaoning, China |
| Model | YST109B-HP880 |
| Measuring Range | pH 0–14 |
| Accuracy | ±0.1 pH |
| Temperature Compensation | 0–99.9 °C (25 °C reference, automatic) |
| Output Signals | 4–20 mA (2-wire), RS485 (Modbus RTU) |
| Power Supply | 24 VDC (wide-input tolerant) |
| Protection Rating | IP65 |
| Response Time | <30 s |
| Stability | ±0.02 pH/24 h |
| Brand | YST (Dalian Yist) |
|---|---|
| Origin | Liaoning, China |
| Model | YST109B-HP880 |
| pH Range | 0–14 |
| ORP Range | −2000 to +2000 mV |
| pH Accuracy | ±0.02 |
| ORP Accuracy | ±5 mV |
| Temperature Compensation | 0–99.9 °C (reference 25 °C |
| Output Signals | 4–20 mA (2-wire), RS485 (Modbus RTU) |
| Power Supply | 24 VDC (wide-range, solar-compatible) |
| Media Compatibility | Aqueous solutions, weakly corrosive liquids (pH 2–12), suspensions |
| Drift Stability | ±0.02 pH/24 h |
| Enclosure Rating | IP65 |
| Response Time | <30 s |
| ADC Resolution | 24-bit |
| Calibration Modes | Manual & Automatic (single-/two-point) |
| Data Logging | 30-day local history storage |
| Electrode Options | Glass, antimony, or refillable gel-filled pH electrodes |
| Brand | YST (Dalian Yist) |
|---|---|
| Model | YST109B-HP880 |
| Measurement Range | pH 0.00–14.00 |
| Accuracy | ±0.1 pH |
| Resolution | 0.01 pH |
| Temperature Compensation | 0–60 °C (Automatic) |
| Power Supply | DC 12 V |
| Power Consumption | ≤1 W |
| Protection Rating | IP65 |
| Operating Temperature | −10 °C to 50 °C |
| Communication Protocol | RS485 Modbus-RTU |
| Brand | YST (Dalian Yist Instruments) |
|---|---|
| Origin | Liaoning, China |
| Model | YST209B-RP880 |
| Measurement Range | -1999 to +1999 mV |
| Accuracy | ±2 mV @ 25 °C |
| Response Time | ≤10 s (to 90% of final value) |
| Temperature Compensation | Automatic, 0–100 °C |
| Output Signals | Isolated 4–20 mA + RS485 digital interface |
| Sensor IP Rating | IP68 |
| Transmitter IP Rating | IP65 |
| Operating Ambient | 0–60 °C, ≤90% RH (non-condensing, away from strong magnetic fields) |
| Power Supply | 220 V ±10%, 50 Hz |
| Installation Type | Submersible (tank/pipeline) |
| Brand | YSTorp (Dalian Yistorp) |
|---|---|
| Origin | Liaoning, China |
| Model | YST209B-RP880 |
| Measuring Range | ORP –1999 to +1999 mV (0.1 mV resolution) |
| Accuracy | ±1 mV (ORP), ±0.5 °C (Temperature, 0–60.0 °C) |
| Automatic Temperature Compensation (ATC) | 0.0–120.0 °C (reference 25 °C) |
| Output | 4–20 mA isolated analog output |
| Power Supply | AC 220 V ±10 %, 50 Hz ±1 Hz |
| Enclosure Rating | IP65 |
| Dimensions | 96 × 96 × 110 mm (panel cutout: 92 × 92 mm) |
| Installation Options | Flow-through, submersible, flanged, pipe-mounted, sidewall-mounted |
| Operating Environment | 0–60 °C ambient, RH <85 % non-condensing |
| Brand | Yuntang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | YT-D-12 |
| Heating Zones | 3 (Headspace Oven, Transfer Line, Six-Port Valve) |
| Temperature Range (Headspace Oven) | Ambient to 260 °C (1 °C adjustable increment) |
| Temperature Range (Transfer Line & Valve) | Ambient to 220 °C (1 °C adjustable increment) |
| Temperature Accuracy | ±0.1 °C |
| Sample Capacity | 12 × 10 mL or 20 mL vials |
| Pressurization Range | 0–0.4 MPa (continuously adjustable) |
| Precision (RSD) | <1.5% for 200 ppm ethanol in water |
| Power Consumption | 1000 W |
| Input Voltage | AC 220 V, 50 Hz |
| Dimensions (W×D×H) | 420 mm × 180 mm × 500 mm |
| Weight | ~17.5 kg |
| Brand | Yuntang |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | YT-NIR-T |
| Heating Method | Infrared |
| Measurement Range | 0–100% w/w |
| Accuracy | ±0.2% w/w (subject to material composition variation) |
| Light Source | Imported high-efficiency NIR source |
| Filter Cycle | 1–60 s |
| Illumination Diameter | 60–75 mm |
| Working Height | 350 mm + 100 mm tolerance |
| Measurement Channels | 50 |
| Probe Window Material | High-borosilicate quartz glass |
| Operating Environment | −40 °C to +70 °C, 5–95% RH (non-condensing) |
| Power Supply | 220 VAC / 50 Hz |
| Communication Interfaces | RS485, 4–20 mA analog output, RS232, Ethernet (LAN), LoRa wireless |
| Enclosure Rating | IP65 |
| Display | Integrated industrial touchscreen |
| Probe Housing | High-strength aluminum alloy |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | YY-980 |
| Application Field | Petroleum & Petrochemical Industry |
| Detection Principle | Pyrolysis-Gas Chromatography with Flame Ionization Detection (FID) |
| Minimum Hydrocarbon Detection | 0.001 mg hydrocarbon/g rock |
| Baseline Drift | <0.1 mV/30 min |
| Linear Dynamic Range | 10⁵ |
| FID Temperature Control | 380 ± 2 °C |
| Pyrolysis Furnace Control | ±1 °C |
| Sample Probe Temperature Control | 90 ± 3 °C |
| Oxidation Furnace Control | 600 ± 1 °C |
| Programmed Temperature Ramp Linearity Deviation | <1 °C/min |
| Detector Configuration | Dual Synchronized FID |
| Valve System | Integrated 9-port, 3-port, and 2-position 5-way solenoid valve manifold for fully automated pyrolysis-residual carbon sequence |
| Signal Amplification | Four-step electronic-switched microcurrent amplifier with high-input-impedance, low-noise op-amp architecture |
| Brand | Zahner |
|---|---|
| Origin | Germany |
| Model | CIMPS-Pro Zennium |
| Instrument Type | Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±3 A, ±10 A |
| Current Accuracy | 0.02% of reading |
| Potential Accuracy | ±50 µV |
| Potentiostatic Range | ±15 V, ±20 V |
| AC Impedance Frequency Range | 10 µHz – 8 MHz |
| Brand | Zahner |
|---|---|
| Origin | Germany |
| Model | IM7 |
| Instrument Type | Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±3 A |
| Current Accuracy | < 0.0025% |
| Potential Range | ±15 V |
| EIS Frequency Range | 10 µHz – 8 MHz |
| Input Impedance | >10 TΩ |
| ADC Resolution | 32-bit |
| Voltage Resolution | 2.5 nV / 7.5 nV |
| Current Resolution | ±2 aA (2 × 10⁻¹⁸ A) |
| Small-Signal Rise Time | 150 ns – 200 µs (5 auto-ranging steps) |
| IR Compensation | Real-time, adaptive |
| Grounding Mode | Switchable floating/grounded |
| Communication Interface | Gigabit Ethernet |
| Internal Storage | 40 GB SSD |
| Brand | Zahner |
|---|---|
| Origin | Germany |
| Model | IM7c |
| Instrument Type | Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±2 A |
| EIS Frequency Range | 10 µHz – 5 MHz |
| ADC Resolution | 32-bit |
| Voltage Scan Range | ±14 V |
| Potentiostatic Range | ±5 V / ±14 V |
| Voltage Resolution | 2.5 nV / 7.5 nV |
| Current Resolution | 2 × 10⁻¹⁸ A |
| Input Impedance | >10 TΩ (HIZ option: 1000 TΩ) |
| AC Voltage Perturbation | 0–6 V (24-bit resolution) |
| AC Current Perturbation | 0–2 A (24-bit, 12 ranges) |
| Grounding Modes | Grounded & Floating |
| IR Compensation Range | 0–10 MΩ |
| Bandwidth | DC–6 MHz |
| Communication Interface | Gigabit Ethernet |
| Internal Storage | 40 GB SSD |
| CV Scan Rate | up to 10,000 V/s (with ADF high-speed option) |
| Brand | Zahner |
|---|---|
| Origin | Germany |
| Model | IM7x |
| Instrument Type | Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±4 A |
| EIS Frequency Range | 10 µHz – 12 MHz |
| Potentiostat Bandwidth | DC – 15 MHz |
| ADC Resolution | 32 bit |
| Input Impedance | >10 TΩ |
| Applied Potential Range | ±15 V |
| Cell Voltage Range | ±32 V |
| Voltage Resolution | 2.5 nV / 7.5 nV |
| Current Resolution | ±2 aA (±2 × 10⁻¹⁸ A) |
| Output Current Accuracy | ±0.025% of reading ± 0.01% of FS (≥3 µA to 300 mA) |
| Rise Time (Small Signal) | 150 ns – 200 µs (5 auto-ranging steps) |
| IR Compensation | Real-time, adaptive EIS-based |
| Grounding Mode | Switchable floating/grounded |
| Communication Interface | Gigabit Ethernet |
| Internal Storage | 40 GB SSD |
| Software Platform | Zahner Lab (Windows 11, Linux, macOS compatible) |
| API Support | Python/C++ SDK included |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Zahner |
|---|---|
| Origin | Germany |
| Model | Zennium Pro |
| Current Range | ±3 A |
| Current Resolution | ±2 aA |
| Potential Accuracy | ±50 µV |
| Potentiostatic Range | ±15 V |
| EIS Frequency Range | 10 µHz – 8 MHz |
| Input Impedance | >10 TΩ |
| ADC Resolution | 32 bit |
| Bandwidth | 10 MHz |
| Voltage Resolution | 3 nV |
| Small-Signal Rise Time | 150 ns – 200 µs (5 steps) |
| Frequency Accuracy | 0.0025% |
| Frequency Resolution | 0.0025%, 10,000 steps/decade |
| Impedance Measurement Range | 10 µΩ to 100 GΩ (depending on probe configuration) |
| IR Compensation | Real-time, adaptive |
| Brand | Zahner |
|---|---|
| Origin | Germany |
| Model | Zennium X |
| Instrument Type | Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±4 A |
| Current Accuracy | ±0.02% of reading + ±0.01% of full scale (1 µA–100 mA), ±0.2% of reading + ±0.1% of full scale (100 mA–3 A), ±0.2% of reading + ±0.1% of full scale (10 nA–1 µA) |
| Potential Accuracy | ±50 µV |
| Potentiostatic Range | ±15 V |
| Compliance Voltage | ±32 V |
| EIS Frequency Range | 10 µHz–12 MHz |
| Frequency Accuracy | 0.0025% |
| Frequency Resolution | 10,000 steps/decade |
| Input Impedance | >10 TΩ |
| Voltage Resolution | 3 nV |
| Current Resolution | ±5 aA (32-bit DAC/ADC) |
| Bandwidth | 15 MHz |
| IR Compensation | Real-time, automatic EIS-based compensation |
| Grounding Mode | Switchable floating/grounded configuration |
| ADC/DAC Resolution | 32-bit HDP (High Dynamic Precision) architecture |
| Brand | Zahner |
|---|---|
| Origin | Germany |
| Model | Zennium X |
| Instrument Type | Electrochemical Workstation |
| Current Range | ±4 A |
| Current Accuracy | ±0.02% of reading + ±0.01% of full scale (1 µA–100 mA) / ±0.2% of reading + ±0.1% of full scale (100 mA–3 A) / ±0.2% of reading + ±0.1% of full scale (10 nA–1 µA) |
| Potential Accuracy | ±50 µV |
| Potentiostatic Range | ±15 V |
| EIS Frequency Range | 10 µHz–12 MHz |
| Input Impedance | >10 TΩ |
| Voltage Resolution | 3 nV |
| Current Resolution | ±2 aA (±2×10⁻¹⁸ A) |
| ADC Resolution | 32 bit |
| Bandwidth | 15 MHz |
| IR Compensation | Real-time, automatic |
| Grounding Mode | Switchable floating/grounded |
| Brand | Zahner |
|---|---|
| Origin | Germany |
| Model | Zennium XC |
| Instrument Type | Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±2 A |
| Current Accuracy | 0.04% |
| Potential Accuracy | 100 µV |
| Potentiostatic Range | ±14 V |
| EIS Frequency Range | 10 µHz – 5 MHz |
| ADC Resolution | 32-bit |
| Voltage Resolution | 2.5 nV / 7.5 nV |
| Input Impedance | 10 TΩ (optional Hi-Z: 1000 TΩ) |
| EIS Accuracy | ±0.2% (100 mΩ–10 MΩ), ±2% (1 mΩ–100 mΩ or 10 MΩ–10 GΩ) |
| AC Perturbation Amplitude | 0–6 V (18-bit resolution) |
| Grounding Modes | Grounded & Switchable Floating Ground |
| IR Compensation | Real-time, automatic, 0–10 MΩ range |
| Bandwidth | 6 MHz |
| CV Scan Rate | up to 10,000 V/s (with ADF high-speed option) |
| Brand | Zahner |
|---|---|
| Origin | Germany |
| Model | Zennium XC |
| Instrument Type | Electrochemical Workstation |
| Current Range | ±2 A |
| Current Accuracy | 0.04% |
| Potential Accuracy | 100 µV |
| Potentiostatic Range | ±14 V |
| EIS Frequency Range | 10 µHz – 5 MHz |
| ADC Resolution | 32-bit |
| Current Resolution | 2 × 10⁻¹⁸ A |
| Voltage Resolution | 2.5 nV / 7.5 nV |
| Input Impedance | 10 TΩ (optional Hi-Z: 1000 TΩ) |
| EIS Accuracy | ±0.2% @ 100 mΩ–10 MΩ |
| AC Perturbation Amplitude | 0–6 V (18-bit resolution) |
| Grounding Modes | Grounded & Floating (for high-isolation applications, e.g., autoclaves, buried pipelines) |
| IR Compensation | Real-time automatic, 0–10 MΩ range |
| Bandwidth | 6 MHz |
| Software | Thales XT (real-time control, multi-channel visualization, offline analysis via Zahner Analysis) |
| Brand | Zahner |
|---|---|
| Origin | Germany |
| Model | ZenniumPro |
| Instrument Type | Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±3 A |
| Current Resolution | ±5 aA |
| Potential Accuracy | ±50 µV |
| Potentiostatic Range | ±15 V |
| EIS Frequency Range | 10 µHz – 8 MHz |
| Input Impedance | >10 TΩ |
| ADC Resolution | 32-bit |
| Bandwidth | 10 MHz |
| Voltage Resolution | 3 nV |
| IR Compensation | Real-time, automatic |
| Grounding Modes | Switchable floating/grounded |
| Small-Signal Rise Time | 150 ns – 200 µs (5 steps) |
| Impedance Accuracy | 1 mΩ–10 GΩ (±2%), 100 mΩ–10 MΩ (±0.2%) in POT mode |
| Software | Thales XT + Zahner Analysis (EIS fitting, CIMPS, Z-HIT, NFRA) |
| Brand | ZEISS |
|---|---|
| Origin | Germany |
| Model | Axiolab 5 Widefield Microscope |
| Dimensions (L×W×H) | ~304 mm × 210 mm × 357.5 mm (base unit without tube, part no. 430037-9011-000) |
| Operating Temperature | +10 °C to +40 °C |
| Relative Humidity | ≤75% at 35 °C (non-condensing) |
| Max. Altitude | 2,000 m |
| Ambient Pressure | 800–1,060 hPa |
| Pollution Degree | 2 |
| Protection Class | IP20 |
| Electrical Safety | Compliant with DIN EN 61010-1 / IEC 61010-1, CSA, UL |
| RF Emission | EN 55011 Class B |
| Immunity | DIN EN 61326/A1 |
| Power Supply | 100–240 V AC, 50–60 Hz |
| Power Consumption | ≤100 VA |