Chemical Analysis Instruments
Filter
Showing 4081–4110 of 10460 results
| Brand | HPG (Huaputongyong) |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Resistive-Filament Pyrolyzer |
| Model | HP2000-GC |
| Price Range | USD 42,000 – 70,000 |
| Compliance | IEC 62321-8:2017 |
| Brand | Csi-lab |
|---|---|
| Model | HR-ARPES200 |
| Energy Resolution | ≤1.8 meV |
| Base Temperature | ≤6.0 K |
| Photon Flux | ≥6×10¹¹ ph/s |
| Origin | Jiangsu, China |
| Distribution Type | Authorized Distributor |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | HS-2 |
| Pricing | Upon Request |
| Instrument Type | Static Headspace Sampler |
| Sample Heating Range | 40–200 °C (±1 °C accuracy) |
| Valve Heating Range | 40–200 °C (±1 °C) |
| Transfer Line Heating Range | 40–200 °C (±1 °C) |
| Sampling Time | 0–20 min |
| Pressurization Time | 0–30 s |
| Loop Volume | 1 mL |
| Vial Capacity | 10 mL or 20 mL vials |
| Sample Position Capacity | 10 positions |
| RSD | ≤1.5% (measured in 200 ppm ethanol in water) |
| Power Consumption | 220 W |
| Dimensions (W×H×D) | 500×180×400 mm |
| Net Weight | ~15 kg |
| Brand | BCT |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | Domestic (China) |
| Model | HS-P5 |
| Instrument Type | Portable |
| Power Supply | Internal Rechargeable Battery or External DC Input |
| Sample Position Capacity | 5 Heated Vials |
| Compatibility | Designed for Coupling with BCT ER Series and P8800 Portable GC-MS Systems |
| Cleaning Function | Integrated Tubing Purge Cycle |
| Operational Mode | Headspace Equilibration with Pre-concentration Estimation Algorithm |
| User Interface | Embedded Control Software with Voice Guidance |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HSM-960-W |
| Product Type | Portable Dew Point Meter |
| Measurement Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature | −20 °C to +50 °C |
| Accuracy | ±1 ppm (v/v) |
| Repeatability | ±0.1 ppm (v/v) |
| Range | 0–10 / 0–100 / 0–1000 / 0–2500 ppm (auto-ranging) |
| Display | Backlit LCD |
| Power Supply | Rechargeable lead-acid battery or 80–230 VAC, 50–60 Hz |
| Power Consumption | 8 W |
| Enclosure Rating | IP20 |
| Dimensions | 363 mm (W) × 115 mm (H) × 377 mm (D) |
| Weight | ~6 kg |
| Brand | HSPX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Model | GC-9100 |
| Temperature Control Range | Ambient +20 °C to 400 °C (oven, inlet, detector) |
| Ramp Rate | 0.1–40 °C/min |
| Cool-down Rate | 450 °C to 50 °C in ~6 min |
| Carrier Gas Flow Range & Control | 0–60 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.6 MPa |
| Injector Max Temp | 400 °C |
| Injector Pressure Setting Range | 0–0.6 MPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Detector Options | FID, TCD, ECD, FPD, NPD |
| Display | Color LCD with bilingual (English/Chinese) UI |
| Control Interface | PC-based software with remote operation capability |
| Automation Interfaces | Built-in driver support for autosamplers, thermal desorbers, purge-and-trap systems |
| Safety Features | Auto flame ignition, flame-out detection & re-ignition, gas leak protection, automatic gas-line initialization |
| Brand | HSPX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Scope | General-Purpose Analytical Chemistry |
| Oven Temperature Range | 4 °C to 450 °C |
| Oven Ramp Rate | 0.1–39 °C/min (Standard Mode) |
| Oven Cool-Down Time | ~6 min (from 450 °C to 50 °C) |
| Carrier Gas Flow Range & Control | 0–1000 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| FID Detection Limit | ≤3×10⁻¹² g/s (n-hexadecane in iso-octane) |
| FID Baseline Noise | ≤5×10⁻¹⁴ A |
| FID Baseline Drift | ≤1×10⁻¹³ A/30 min |
| FID Linear Dynamic Range | ≥10⁶ |
| Brand | HSPX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Scope | General-Purpose Analytical Use |
| Oven Temperature Range | Ambient + 20 °C to 400 °C |
| Ramp Rate | 0.1–40 °C/min |
| Cool-Down Time | ≤5 min (from 400 °C to 50 °C) |
| Carrier Gas Flow Range & Control | 0–1000 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Detector Temperature Range | Ambient + 20 °C to 400 °C |
| TCD Sensitivity | ≥5000 mV·mL/mg (n-heptane) |
| FID Detection Limit | <8×10⁻¹² g/s (n-decane) |
| NPD Detection Limits | ≤1×10⁻¹² g/s (N), ≤1×10⁻¹³ g/s (P) |
| FPD Detection Limits | ≤8×10⁻¹¹ g/s (S), ≤4×10⁻¹² g/s (P) |
| Column Compatibility | Packed columns (2–4 mm ID), Capillary columns (0.1–0.53 mm ID), Including Wide-Bore (0.53 mm) Systems |
| Brand | HSPX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | GC-Universal Series |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Scope | General-Purpose Analysis |
| Oven Temperature Range | Ambient + 4 °C to 450 °C (1 °C increment, ±0.01 °C accuracy) |
| Ramp Rate | 0.1–39 °C/min (Standard) |
| Cool-Down Rate | 450 °C → 50 °C in ~6 min |
| Carrier Gas Flow Control Range | 0–1000 mL/min |
| Carrier Gas Pressure Control Range | 0–970 kPa |
| Injector Max Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Column Oven Programmable Steps | 16-stage |
| Hold Time per Step | 0–655 min |
| TCD Sensitivity | ≥5000 mV·mL/mg |
| FID Detection Limit | ≤5×10⁻¹² g/s (n-decane) |
| ECD Detection Limit | ≤1×10⁻¹³ g/s (γ-BHC) |
| FPD Detection Limit | ≤5×10⁻¹³ g/s (S), ≤1.4×10⁻¹³ g/s (P) |
| NPD Detection Limit | ≤5×10⁻¹³ g/s (N) |
| Power Supply | 220 V ±10% AC, 50 ±0.5 Hz |
| Max Power Consumption | ≤1500 W |
| Dimensions (L×W×H) | 628 × 465 × 460 mm |
| Weight | 50 kg |
| Brand | HSPX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | HS-6D |
| Pricing | Available Upon Request |
| Flow Control | Mass Flow Controllers (MFCs) |
| Display | 7-inch Capacitive Touchscreen |
| Gas Path Materials | Passivated Stainless Steel Tubing & PTFE Tubing |
| Built-in Pump | Diaphragm Pump for Ambient-Pressure Gas Sampling |
| Dilution Range | 1:1 to 1:100 (customizable) |
| Output Channels | 6 Independent Concentration Ports |
| Operation Modes | Single-point or Multi-step Sequential Dilution |
| Method Storage | Onboard Method Library with Recall Function |
| Software Interface | Single- or Multi-channel Configuration Support |
| Brand | HSPX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HTB-3420 |
| Temperature Control Range | Ambient to 400 °C |
| Tube Capacity | 1–20 tubes |
| Temperature Setting Increment | 1 °C |
| Temperature Accuracy | ±0.5% of setpoint |
| Temperature Uniformity | ±1 °C across chamber |
| Timer Range | 0–99 h 99 min, continuously adjustable |
| Tube Compatibility | Outer diameter 6 mm (¼ inch), unlimited length |
| Brand | HSPX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Petrochemical Industry Dedicated |
| Oven Temperature Range | Ambient +5°C to 400°C |
| Oven Ramp Rate | 0.1–40°C/min |
| Oven Cool-down Time | ~6 minutes (from 450°C to 50°C) |
| Carrier Gas Flow Range & Control | 0–1000 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 400°C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1000 mL/min |
| Brand | HSPX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | Solvent Residue GC for Plastic Flexible Packaging |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Food Industry-Specific |
| Oven Temperature Range | Ambient + 5°C to 400°C |
| Ramp Rate | 0.1–40°C/min |
| Cool-down Rate | ~6 min (400°C → 50°C) |
| Carrier Gas Flow Range & Control | 0–1000 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Max Operating Temperature | 400°C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1000 mL/min |
| Brand | HSPX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | Refinery Gas-Specific GC |
| Temperature Control Range | Ambient to 400 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Cool-down Time | ~6 min (400 °C → 50 °C) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.6 MPa |
| Injector Max Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–0.6 MPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Detectors | TCD and FID |
| Column Types | Packed and Capillary |
| Multi-Valve Auto-Switching | Yes |
| Signal Auto-Switching | Yes |
| Analysis Scope | H₂, O₂, N₂, CO₂, CO, C₁–C₆₀ hydrocarbons (including C₂=–C₄= olefins and C₆⁺ saturates/olefins/aromatics) |
| Brand | HSPX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | Solvent Residue Analysis in Edible Oils, Food Additives, and Pesticide Residues |
| Oven Temperature Range | Ambient to 400 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cool-down Time | ~6 min (400 °C → 50 °C) |
| Carrier Gas Flow Control Range | 0–1200 mL/min |
| Carrier Gas Pressure Control Range | 0–0.6 MPa |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–0.6 MPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Detector | Flame Ionization Detector (FID) |
| Column Compatibility | Capillary columns for volatile organic solvent separation (e.g., DB-VRX, HP-PONA, or equivalent polar/non-polar GC columns) |
| Data System | Integrated GC workstation with peak integration, calibration curve generation, and audit-trail-capable reporting |
| Brand | HSPX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic Instrument |
| Model | Solvent Residue-Specific Gas Chromatograph |
| Price Range | USD 7,000 – 14,000 (FOB) |
| Instrument Type | Laboratory-Grade Gas Chromatograph |
| Primary Application Domain | Food Packaging Safety Testing |
| Oven Temperature Range | Ambient to 400 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cool-Down Time | ~6 min (from 400 °C to 50 °C) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.6 MPa |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–0.6 MPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Detector | Flame Ionization Detector (FID) |
| Column | Pre-configured Capillary Column for Volatile Organic Solvent Separation |
| Data System | Integrated Chromatography Workstation with Audit Trail Capability |
| Required Gases | High-Purity Nitrogen (carrier), Hydrogen (detector fuel), and Compressed Air (detector oxidant) |
| Brand | HSPX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | TDS-3410A |
| Temperature Control Range | Ambient to 400 °C |
| Gas Flow Rate | 0–300 mL/min |
| Tube Capacity | 6–10 tubes |
| Temperature Setting Increment | 1 °C |
| Temperature Stability | ±0.5% of setpoint |
| Timer Range | 0–655 minutes |
| Power Consumption | <500 W |
| Dimensions (W×D×H) | 170×390×400 mm |
| Weight | ~8 kg |
| Brand | Shimadzu |
|---|---|
| Origin | Italy |
| Model | HT200H Headspace Autosampler |
| Sample Capacity | 40 positions (for 10 mL or 20 mL headspace vials) |
| Sample Heating Block | Simultaneous heating of up to 6 vials |
| Heating Temperature Range | 40–150 °C |
| Heating Time Range | 0–23 h 59 min |
| Agitation Duration | 0–99 min |
| Agitation Speed | Adjustable |
| Syringe Volume | Standard 2.5 mL, optional 5 mL |
| Minimum Injection Volume | 0.01 mL |
| Injection Flow Rate | 0.1–100 mL/min |
| Equilibration Delay | 0–60 s |
| Needle Temperature Control | 40–150 °C |
| Carrier/Purge Gas | Inert gas (N₂ or He) |
| Extraction Mode | Multiple Headspace Extraction (MHE), up to 15 cycles |
| Software Compatibility | HT-Comsoft-H and Clarity Chromatography Data Systems |
| Position Flexibility | Removable sample tray configurable for left- or right-side installation |
| Brand | HTA |
|---|---|
| Origin | Italy |
| Model | HT4150L |
| Instrument Type | Multifunctional Autosampler |
| Max Sample Capacity | 32 tubes (2 × 16-position racks) |
| Minimum Dispensing Volume | 0.1 mL |
| Quantitative Loop Volumes | 1 mL and 2.5 mL |
| Positioning Accuracy | < 0.2 mm |
| Motion Architecture | XYZ three-axis robotic arm |
| Needle Wash | Internal and external wall rinsing |
| Repeat Injection Capability | Unlimited cycles |
| Brand | Huaai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | GC-9560 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | High-Purity Gas Analysis (Specialized for Kr, He, Ne, Xe, Ar) |
| Oven Temperature Range | 0–400 °C |
| Maximum Ramp Rate | 40 °C/min |
| Cooling Rate (350 °C → 50 °C) | ≤8 min |
| Carrier Gas Flow Control Range | 0–500 mL/min |
| Carrier Gas Pressure Control Range | 0–0.4 MPa |
| Injector Maximum Operating Temperature | 399 °C |
| Injector Pressure Setting Range | 0–0.4 MPa |
| Injector Total Flow Setting Range | 0–500 mL/min |
| Detection Limit (for N₂, O₂, CH₄, CO, CO₂, H₂, H₂O, CF₄) | ≤5 ppb (v/v) |
| Detector Type | High-Sensitivity Helium Ionization Detector (HID) |
| Column Configuration | Multi-Column Oven with Independent Temperature Zones |
| Sample Introduction | Dual-Channel Valve System with Purge-Protected Switching Valves |
| Flow Compensation | Automatic Inlet Pressure Correction Algorithm for Variable Base-Gas Matrices |
| Compliance Reference | GB/T 5829–2006 (Krypton Specification), GB/T 28123–2011 (High-Purity Noble Gases), ASTM D7606–22 (Trace Impurity Analysis in Ultra-High-Purity Gases) |
| Brand | Huai Ai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | GC-9560-PDD |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Domain | Dedicated High-Purity & Electronic Specialty Gas Analysis |
| Oven Temperature Range | +8 °C to 400 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cooling Rate | ~7 min (400 °C → 50 °C) |
| Carrier Gas Flow Range & Control | 0–1000 mL/min |
| Carrier Gas Pressure Range & Control | 0–500 psi |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setpoint Range | 0–500 psi |
| Injector Total Flow Setpoint Range | 0–1000 mL/min |
| Brand | Huai Ai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (PRC) |
| Model | GC-9560-HD DGA System |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Domain | Power Industry–Specific |
| Temperature Control Range | Ambient +8 °C to 399 °C |
| Maximum Ramp Rate | 40 °C/min |
| Column Oven Cooling Time | <5 min |
| Carrier Gas Flow Range & Control | 0–500 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.4 MPa |
| Injector Max Operating Temperature | 399 °C |
| Injector Pressure Setpoint Range | 0–0.4 MPa |
| Injector Total Flow Setpoint Range | 0–500 mL/min |
| Detection Limits (as per DL/T 703–1999) | H₂ <2 µL/L, O₂ <5 µL/L, N₂ <5 µL/L, CO <2 µL/L, CO₂ <2 µL/L, Hydrocarbons <0.1 µL/L |
| Temperature Stability | ±0.1 °C across all zones (oven, injector, detectors, methanizer) |
| Detectors | Dual-channel TCD and FID with Ni-catalyst methanizer |
| Column Configuration | Parallel dual-column gas separation path |
| Brand | Huai Ai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | GC-9560-HM |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | Universal |
| Oven Temperature Range | 8 °C above ambient to 399 °C |
| Temperature Ramp Rate | 1–40 °C/min |
| Cooling Rate | ~50 °C in ≤7 min (from 350 °C to 50 °C) |
| Carrier Gas Flow Range & Control | 0–500 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.4 MPa |
| Injector Maximum Operating Temperature | 399 °C |
| Injector Pressure Setting Range | 0–0.4 MPa |
| Injector Total Flow Setting Range | 0–500 mL/min |
| Column Oven Dimensions | 315 × 300 × 195 mm |
| Temperature Control Precision | ±0.1 °C (six independent zones) |
| Programmed Temperature Ramping | 8-step |
| Hold Time per Step | 0–655 min (1-min increments) |
| Detector | TCD (Thermal Conductivity Detector), dual-channel, rhenium-tungsten filament, constant-current operation |
| TCD Sensitivity | ≥2500 mV·mL/mg (n-hexadecane/isooctane) |
| Baseline Noise | ≤15 μV |
| Baseline Drift | ≤100 μV/30 min |
| Linearity | ≥10⁴ |
| Compliance | GB 10410–1989 |
| Brand | Huai Ai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | GC-9780A |
| Detection Limit | ≤8×10⁻¹² g/s (n-hexadecane/isooctane) |
| Repeatability | <3% RSD |
| Weight | <48 kg |
| Dimensions | 590 × 550 × 680 mm |
| Brand | Huai Ai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | HA-9660-PDD |
| Instrument Type | Online Gas Chromatograph |
| Application Field | High-Purity Gas Analysis |
| Oven Temperature Range | 8°C above ambient to 400°C |
| Ramp Rate | 1–40°C/min |
| Cool-down Rate | 400°C to 50°C in 7 min |
| Carrier Gas Flow Range & Control | 0–100 mL/min (electronic monitoring) |
| Carrier Gas Pressure Range & Control | 0–0.4 MPa (8-step setting) |
| Injector Max Temp | 400°C |
| Injector Pressure Setting Range | 0–0.1 MPa |
| Injector Total Flow Setting Range | 0–50 mL/min |
| Detector | Pulsed Discharge Helium Ionization Detector (PDHID) |
| Detection Limit | ≤5 ppb |
| Drift/Repeatability | ±1%–±5% |
| Sample Gas Flow | 50 mL/min |
| Sample Gas Pressure | 0.1 MPa |
| Sample Inlet | 1/4″ Swagelok SS |
| Carrier Gas | He |
| Carrier Inlet | 1/8″ Swagelok SS |
| Display | LED |
| Power Supply | AC 220 V, 50–60 Hz |
| Power Consumption | 400 W |
| Weight | 20 kg |
| Dimensions | 482 mm (W) × 222 mm (H) × 400 mm (D), 5U rack-mountable |
| Communication Interface | RS-232 / RS-485 |
| Protocol | Modbus |
| Brand | Huai Chromatography |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC-9560-HC |
| Temperature Control Range | 0–400 °C |
| Oven Ramp Rate | 0–40 °C/min |
| Oven Cool-down Rate | 350→50 °C in ≤8 min |
| Carrier Gas Flow Range & Control | 0–800 mL/min |
| Carrier Gas Pressure Range & Control | 0–500 kPa |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–500 kPa |
| Injector Total Flow Setting Range | 0–800 mL/min |
| Detection Limit (H₂ matrix, TCD) | O₂/N₂/CO/CH₄/CO₂ ≤ 0.1–2 ppm (3 mL sample) |
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region Classification | Domestic (China) |
| Model | GC-9760A |
| Price Range | USD 14,000 – 42,000 |
| Dimensions | 380 × 450 × 180 mm |
| Weight | <15 kg |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Column Oven Temp Range | 8 °C above ambient to 400 °C (±0.1 °C) |
| TCD Detection Limit | ≤ 100 μL/L (H₂) |
| FID Detection Limit | ≤ 0.1 μL/L (C₂H₂) |
| Linear Dynamic Range | ≥10⁴ (TCD), ≥10⁶ (FID) |
| Standard Compliance | GB/T 17623–1998, GB/T 7252–2001, DL/T 703–1999 |
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | GC-9560 |
| Price Range | USD 7,000–14,000 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Domain | Petrochemical & Electronic Specialty Gases |
| Temperature Control Range | Ambient +8 °C to 399 °C |
| Maximum Ramp Rate | 40 °C/min |
| Oven Cooling Time | <5 min (from 350 °C to 50 °C) |
| Carrier Gas Flow Range & Control | 0–500 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.4 MPa |
| Injector Maximum Operating Temperature | 399 °C |
| Injector Pressure Setting Range | 0–0.4 MPa |
| Injector Total Flow Setting Range | 0–500 mL/min |
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Origin | Domestic (China) |
| Model | GC-9560-1 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | 8 °C above ambient to 399 °C |
| Ramp Rate | 1–40 °C/min |
| Cool-down Time | ~7 min (350 °C → 50 °C) |
| Carrier Gas Flow Range & Control | 0–500 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.4 MPa |
| Injector Maximum Operating Temperature | 399 °C |
| Injector Pressure Setting Range | 0–0.4 MPa |
| Injector Total Flow Setting Range | 0–500 mL/min |
| Column Oven Precision | ±0.1 °C |
| Programmed Temperature Steps | 8-step |
| Hold Time per Step | 0–655 min (1-min increments) |
| FID Detection Limit | ≤1×10⁻¹¹ g/s (n-hexadecane / isooctane) |
| FID Baseline Noise | ≤2×10⁻¹³ A |
| FID Drift | ≤2×10⁻¹² A/30 min |
| FID Linearity | ≥10⁶ |
| TCD Sensitivity | ≥2500 mV·mL/mg (n-hexadecane / isooctane) |
| TCD Baseline Noise | ≤20 µV |
| TCD Drift | ≤100 µV/30 min |
| TCD Linearity | ≥10⁴ |
| Dimensions | 655 mm (W) × 500 mm (H) × 480 mm (D) |
| Weight | ~48 kg |
| Power Supply | 220 V ± 22 V, 50 Hz, ≥2 kW |
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | GC-9560-EG |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Domain | Ultra-High-Purity (UHP) and Electronic Grade (EG) Gas Analysis |
| Oven Temperature Range | +8 °C to 400 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cool-Down Rate | 400 °C → 50 °C in ~7 min |
| Carrier Gas Flow Control Range | 0–400 mL/min |
| Carrier Gas Pressure Control Range | 0–1000 psi |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–1000 psi |
| Injector Total Flow Setting Range | 0–400 mL/min |