Chemical Analysis Instruments
Filter
Showing 4981–5010 of 10793 results
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | WA2002SF |
| Pricing | Available Upon Request |
| Origin | Denmark |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LabFlicker |
| Dimensions (L × W × H) | 115 × 53 × 13 mm |
| Weight | 0.16 kg |
| Shipping Dimensions (L × W × H) | 170 × 130 × 70 mm |
| Shipping Weight | 0.5 kg |
| Warranty | 2 years |
| Software Integration | Light Inspector (Viso Systems) |
| Output Metrics | Flicker Percentage, Flicker Index, Flicker Frequency, SVM (Stroboscopic Visibility Measure), PstLM (Short-Term Flicker Indicator per IEC TR 61547-1), JA8 §24 Compliance Data |
| Data Export | CSV & Excel-compatible arrays |
| Real-time Signal Processing | Onboard intelligent algorithm engine |
| Brand | GRACE |
|---|---|
| Origin | Germany |
| Model | RI 2000 |
| Detection Principle | Differential Refractometry |
| Refractive Index Range | 1.00–1.75 |
| Flow Rate Range | 0.2–3.0 mL/min |
| Linear Range | 80 × 10⁻⁵ RIU |
| Noise Level | 5 × 10⁻¹⁰ RIU |
| Auto-Zero Range | 40 × 10⁻⁵ RIU |
| Auto-Zero Resolution | 5 × 10⁻¹⁰ RIU |
| Integrator Output | ±1 V |
| Recorder Output | ±10 V |
| Analog Input Range | −5 to +5 V DC |
| Temperature Setpoints | Ambient, 35 °C, or 55 °C (microprocessor-controlled) |
| Flow Cell Volume | 9 µL |
| Maximum Flow Cell Pressure | 6 kg/cm² |
| Brand | Labman |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Electrochemical Workstation |
| Model | LABMAN 64-Channel Potentiostat System |
| Channel Count | 64 independent electrochemical channels |
| Current Range | ±1 A per channel |
| Current Accuracy | ±1% of full scale |
| Potential Accuracy | ±1 mV (typical, referenced to internal calibration standard) |
| Potentiostatic Range | ±10 V vs. reference electrode |
| AC Impedance Frequency Range | 1 Hz – 1 MHz (per channel, with optional frequency extension modules) |
| Compliance | CE-marked, RoHS-compliant, designed for integration into GLP/GMP-regulated laboratory automation platforms |
| Brand | Labman |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | LABMAN High-Throughput Automated Absorbance Measurement System |
| Optical Design | Dual-Beam |
| Detector | CCD (Charge-Coupled Device) |
| Wavelength Range | 190–900 nm |
| Wavelength Selection | Manual |
| Spectral Bandwidth | 650 nm |
| Wavelength Accuracy | ±2.0 nm |
| Stray Light | ≤0.01% T |
| Sample Capacity | 192-position rack (17 mm height, dual-diameter transparent glass vials) |
| Throughput | Up to 180 samples/hour |
| Scan Speed | ≥12 vials/minute |
| LED Source | Red 4-element array @ 650 nm |
| Brand | Labman (formerly LABA Tianjin) |
|---|---|
| Model | LB8120 |
| Detector Type | Ultraviolet-Visible Absorbance Detector |
| Wavelength Range | 190–900 nm |
| Optical Design | Dual-Beam with Shielded Optics |
| Light Source | Deuterium Lamp |
| Grating Type | Holographic Concave Grating |
| Detection Mode | Programmable Dual-Wavelength Simultaneous Monitoring |
| Spectral Acquisition | Continuous Rapid Scanning |
| Lamp Control | Fully Automated Start/Stop with Warm-up Optimization |
| Origin | USA-assembled with global supply chain integration |
| Compliance | Designed to support GLP/GMP workflows and ASTM E260, ISO 17025-aligned operation |
| Brand | Labman |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | LBI860 |
| Pricing | Available Upon Request |
| Brand | JAI |
|---|---|
| Origin | Japan |
| Model | LaboACE LC7080 |
| Application Level | Laboratory-grade |
| Instrument Type | Medium-to-Low Pressure Preparative LC |
| Flow Rate Range | 0.1–80.0 mL/min |
| Flow Accuracy | CV < 0.3% |
| Flow Precision (Repeatability) | CV < 0.3% |
| Maximum Operating Pressure | 20 MPa |
| Wavelength Range | 190–700 nm |
| Wavelength Repeatability | ±0.5 nm |
| Baseline Noise | ≤0.00005 AU (at 254 nm, 1 s time constant) |
| Data Acquisition Rate | 50–100 Hz |
| Footprint | 382 mm (W) × 432 mm (D) |
| Recycling Capability | Fully Automated Solvent-Saving Loop Mode with Real-Time Fraction Re-injection Logic |
| Brand | Labomatic |
|---|---|
| Origin | Switzerland |
| Type | Dynamic Axial Compression (DAC) System |
| Construction Material | Borosilicate Glass |
| Max Operating Pressure | 65 bar (940 psi) |
| Piston Adjustment Range | 150 mm |
| Column Diameter Options | 8 sizes (28–300 mm) |
| Column Length Options | 3 standard lengths |
| Seal Design | Spring-loaded elastomeric seals |
| Sample Distribution | Optimized distributor for improved packing reproducibility |
| Compatibility | Biocompatible inert materials |
| Modular Conduit System | Shared tubing manifold for multi-column operation |
| Packing Tool Kits | Available for all AMC column diameters |
| Regulatory Context | Designed for GLP-compliant preparative chromatography workflows |
| Brand | Labomatic |
|---|---|
| Origin | Switzerland |
| Model | LH3000 |
| Instrument Type | HPLC Autosampler |
| X-axis Travel Range | 160–2800 mm (customizable) |
| Y-axis Travel Range | 70–670 mm (single arm) |
| Z-axis Height Range | 130–780 mm (fixed base height), max vertical stroke: 400 mm |
| Compliance | Designed for GLP/GMP environments |
| Brand | Labomatic |
|---|---|
| Origin | Switzerland |
| Model | LHP3000 / LMP3000 |
| Instrument Type | High-Pressure Preparative LC System |
| Pump Flow Range | 0.2–1640 mL/min |
| Max Pressure | 600 bar (HDK-51) to 150 bar (HDK-1640) |
| Flow Stability | RSD < 0.1% |
| Piston Stroke | 3.2–17.1 mm |
| Piston Frequency | 0–200 cycles/min |
| Wetted Materials | Sapphire, Ruby, Zirconia Ceramic, PEEK, 1.4435 Stainless Steel |
| Power Supply | 110 / 230 V, 50 / 60 Hz, 1200 VA |
| Dimensions (Controller) | 316 × 142 × 400 mm (W × H × D) |
| Dimensions (Pump Unit) | 316 × 198 × 400 mm |
| Interface Options | 1/4″, 1/8″, 1/16″ |
| Brand | LABORAT |
|---|---|
| Model | LYM-1061 |
| Derivatization Volume Options | 0.50 / 0.75 / 1.00 / 1.50 mL |
| Reaction Loop Material | Polyetheretherketone (PEEK), Polytetrafluoroethylene (PTFE), 316L Stainless Steel |
| Operating Temperature Range | Ambient + 5.0 °C to 150.0 °C |
| Flow Rate Control Range | 0.001–4.999 mL/min |
| Pump Fluid Path | Full-PEEK chemically inert construction |
| Reaction Coil Layout | 1.2 cm annular configuration |
| Real-time Instrument Status Monitoring | Yes |
| Optional Piston Wash | 1 mL/min |
| Brand | Laborator |
|---|---|
| Model | LYR-1090 |
| Light Source Wavelength | 253.7 nm |
| Derivatization Cell Volume | 1 mL |
| UV Lamp Lifetime | 7,000 h |
| Temperature Monitoring | Yes |
| UV Intensity Monitoring | Yes |
| Compliance | Designed for USP <621>, ISO/IEC 17025, and GLP-aligned workflows |
| Software Audit Trail | Not included (available in LYR-2094 variant) |
| Origin | China |
| Brand | SANXIN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | LabSen871 |
| Measurement Range | 1–13 pH |
| Brand | SANXIN (Sanxin Peray) |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | LabSen873 |
| Measurement Range | 1–13 pH |
| Reference Junction | Dual-Liquid-Junction with Movable Sleeve |
| Sensing Membrane | Reinforced Thick-Film pH Glass |
| Internal Electrolyte | Blue Gelled Polymer Electrolyte |
| Temperature Compensation | Integrated Pt1000 RTD Sensor |
| Compatibility | Methanol, Ethanol, Isopropanol, DMSO, Acetonitrile, Hexane, Chloroform, Toluene, etc. |
| Construction | PHY Protective Hydration Layer for Organic Solvent Resistance |
| Brand | Labsphere |
|---|---|
| Model | CSS-04-010 |
| Material | Spectralon® (PTFE-based diffuse reflectance standard) |
| Diameter | 1.25 in |
| Colors | Red, Green, Blue, Yellow |
| Reflectance Uniformity | < ±0.2% across surface |
| Angular Independence | Lambertian behavior (±0.5° viewing angle tolerance) |
| Thermal Stability | –40 °C to +80 °C |
| Cleanability | Water-rinsable, non-abrasive wipe compatible |
| Compliance | NIST-traceable calibration available (optional) |
| Origin | USA |
| Brand | LabSphere |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | SRT |
| Pricing | Available Upon Request |
| Origin | Denmark |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LABSPION |
| Price | USD 35,000 (FOB Copenhagen) |
| Brand | LabTech |
|---|---|
| Origin | Switzerland |
| Manufacturer | LabTech Instruments AG |
| Product Type | Multifunctional Autosampler for GC/GC-MS/LC/LC-MS |
| Core Techniques | Purge-and-Trap, Static/Dynamic Headspace, Solid-Phase Microextraction (SPME), Thermal Desorption, Pyrolysis, Large-Volume Injection, Gel Permeation Chromatography (GPC) Cleanup, µSPE, Vortex Mixing, Liquid-Liquid Extraction, Derivatization, Cap Piercing, Pipetting |
| Platform Compatibility | GC, GC-MS, LC, LC-MS/MS (vendor-neutral interface) |
| Structural Design | Modular, Rack-Mounted, Instrument-Integrated Platform |
| Configurable Footprint | 534 mm to 1600 mm linear rail length |
| Automation Level | Fully Unattended Operation with Inter-Module Tool Exchange |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | CDS 5200 |
| Price | Upon Request |
| Pyrolysis Temperature Range | Ambient to 1400 °C (adjustable in 0.1 °C increments) |
| Temperature Accuracy | ±0.1 °C |
| Maximum Pressure Rating | 500 PSI (3400 kPa) |
| Heating Rate (Pulse Mode) | 10–20,000 °C/sec |
| Heating Rate (Programmed Mode) | 0.01–999.9 °C/sec or 0.01–999.9 °C/min |
| Programmable Steps per Run | Up to 8 steps with independent GC trigger per step |
| Transfer Line Max Temp | 350 °C |
| Interface Temp | ≥350 °C |
| Sample Path Material | Inert (e.g., SilcoNert®-treated stainless steel or fused silica) |
| Optional In-line Cold Trap | Integrated cryo-focusing with thermal desorption |
| Atmosphere Control | N₂, air, O₂, He, or custom gas (via external mass flow controller) |
| Catalytic Reactor | 3″ × 1/4″ OD 316 stainless steel, rated to 800 °C, user-replaceable catalyst bed |
| Brand | LabTech |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | I-Lab 180 |
| Pricing | Upon Request |
| Brand | Laba (Tianjin Laba Co., Ltd.) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 10 / 20 / 80 |
| Application Level | Industrial-Scale Preparative |
| Instrument Type | High-Pressure Preparative LC System |
| Flow Rate Range | 0–600 mL/min |
| Flow Accuracy | RSD < 0.06% |
| Flow Precision | RSD < 0.06% |
| Maximum Pressure | 25,000 psi |
| Wavelength Range | ±1 nm |
| Wavelength Repeatability | 0.1 nm |
| Baseline Noise | 0.2 × 10⁻⁵ AU |
| Data Acquisition Rate | 500 Hz |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Flame and Graphite Furnace AAS |
| Model | LabAA 2000 |
| Monochromator | Plane Grating |
| Optical System | Single-Beam |
| Detector | Solid-State Detector |
| Background Correction | D₂ Lamp + Self-Absorption Method |
| Resolution | Mn Doublet (279.5–279.8 nm), Valley-to-Peak Ratio ≤30% at 279.5 nm |
| Sensitivity | Flame Mode — Cu Characteristic Concentration ≤0.035 mg/L |
| Precision (RSD) | Flame Cu (2 ppm) ≤1.0% |
| Detection Limits | Flame — sub-ppb to ppm range |
| Baseline Stability | ≤±0.003 Abs over 30 min at Cu 324.8 nm |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Dual Sequential Injection Pumps |
| Waste Liquid Disposal | Peristaltic Pump Extraction |
| Hydride Generation Mode | Vapor Generation / Hydride Generation |
| Gas Flow Control | Rotameter |
| Detectable Elements | As, Sb, Bi, Hg, Se, Te, Sn, Ge, Pb, Zn |
| Relative Standard Deviation (RSD) | ≤0.7% |
| Linear Dynamic Range | ≥3 orders of magnitude |
| Detection Limits | As, Se, Bi, Pb, Sb, Te, Sn, Zn < 0.01 µg/L |
| Photomultiplier Tube (PMT) Wavelength Range | 160–320 nm |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Sequential Scanning ICP-OES |
| Detection Limit | <1 ppb (typ. for key elements) |
| Precision (RSD) | ≤1% |
| Stability (RSD, 4h) | ≤2% |
| Wavelength Range | 165–900 nm |
| Optical Resolution | 6 pm / 7 pm / 10 pm @ 257.610 nm (Mn line, measured) |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Regional Category | Domestic (China) |
| Model | LabICP 2000 ICP-OES |
| Instrument Type | Full-Spectrum Simultaneous ICP-OES |
| Optical Design | Prism + High-Resolution Echelle Grating Two-Dimensional Cross-Dispersed System |
| Detector | Megapixel Large-Area CCD |
| Plasma Orientation | Vertical Torch |
| Observation Modes | Radial, Axial, Dual-View, and Attenuated Variants |
| Gas Control | Mass Flow Controllers (MFCs) for All Gases |
| Software | HiICP Platform with Real-Time & Offline Analysis Capabilities |
| Cooling | Thermoelectrically Cooled CCD with MPS Thermal Isolation Structure |
| Purge | Positive-Pressure Sealed Spectrometer Chamber with Independent Front-Optics Purge |
| RF Generator | Solid-State Crystal-Controlled RF Source with Real-Time Power Monitoring |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | LabMS 3000 |
| Pricing | Upon Request |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | LabMS 3000 |
| Instrument Type | Quadrupole ICP-MS |
| Application Environment | Laboratory |
| Detection Principle | Inductively Coupled Plasma Ionization + Mass Separation via RF Quadrupole Filter |
| Software Platform | HiMass Intelligent Workstation |
| Safety Architecture | Five-Level Integrated Safety Protection System |
| Maintenance Logging | Automated Scheduled Maintenance Audit Trail |
| Sample Introduction | Integrated High-Matrix Sample Introduction System with On-Line Argon Dilution and Oxygen-Added Organic Sample Desolvation |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Quadrupole-based ICP-MS/MS |
| Configuration | Dual-mode (QqQ and single-quadrupole) |
| Application Domain | Laboratory-based elemental and isotopic analysis |
| Regulatory Compliance | SEMI S2 certified |
| Safety Architecture | 10-layer integrated hardware and firmware safety interlocks |
| Software Platform | HiMass Intelligent Workstation (v3.2+) |
| Ion Source | Robust 27 MHz solid-state RF generator with auto-matching plasma system |
| Interface Design | High-efficiency nickel sampler/skimmer cone assembly with active cooling |
| Ion Optics | Multi-stage electrostatic ion guide with collision/reaction cell (CRC) featuring mass-resolved reaction monitoring (MRM) capability |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Conventional High-Performance Liquid Chromatograph (HPLC) |
| Model | LC600 Binary High-Pressure Gradient HPLC System |
| Compliance | Designed for GLP/GMP-aligned laboratories |
| Software | PC-controlled with audit trail capability (21 CFR Part 11 compliant configuration available) |