Chemical Analysis Instruments
Filter
Showing 4951–4980 of 10774 results
| Brand | LABA (Tianjin LABA) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | PR-2 |
| Temperature Range | Ambient to 200 °C |
| Derivatization Reagent Flow Rate | 0.001–10.000 mL/min |
| Reaction Coil Material | PEEK |
| Brand | LABA (Tianjin LABA Co., Ltd.) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | 20 / 80 / 200 / 500 |
| Application Level | Laboratory-Scale Preparative |
| Instrument Type | High-Pressure Preparative LC System |
| Flow Rate Range | 0–600 mL/min |
| Flow Accuracy | RSD < 0.06% |
| Flow Precision (Repeatability) | RSD < 0.06% |
| Maximum Operating Pressure | 25,000 psi |
| Wavelength Range | ±1 nm |
| Wavelength Repeatability | ±0.1 nm |
| Baseline Noise | 2.0 × 10⁻⁶ AU |
| Data Acquisition Rate | 500 Hz |
| Brand | LABA |
|---|---|
| Origin | USA |
| Model | Series 8000 |
| HPLC Type | Conventional High-Performance Liquid Chromatograph |
| Flow Rate Range | 0–10 mL/min |
| Maximum Pressure | 9000 psi |
| Flow Precision | <0.1% RSD |
| Autosampler Capacity | 120 positions |
| Injection Volume Range | 0–3 mL |
| Column Oven Temperature Range | (Ambient + 20°C) to 200°C |
| UV/Vis Wavelength Range | 190–900 nm |
| Data Acquisition Rate | 500 Hz |
| Brand | LABA |
|---|---|
| Model | SeriesII |
| Type | Isocratic Pump |
| Flow Rate Range | Up to 40 mL/min |
| Drive Mechanism | Microstepping Stepper Motor |
| Control Interface | LED Display + Keypad |
| Warranty | 3 Years |
| Origin | USA |
| Category | HPLC Accessory / Isocratic Solvent Delivery System |
| Compliance | Designed for GLP-compliant laboratories, compatible with ASTM D5279 and ISO 13877 workflows for liquid chromatographic method validation |
| Brand | Laballiance |
|---|---|
| Origin | USA |
| Model | FC Jr |
| Dimensions | 28 cm (W) × 27 cm (H) × 31 cm (D) |
| Weight | 4.7 kg |
| Temperature Range | 0–40 °C |
| Step Timer Range | 1 s – 99 h 59 min 59 s |
| Drop Counter Range | 1–999,999 |
| Volume Counter Range | 1–999,999 units |
| Peak Detection Modes | Slope-based and/or plateau-based triggering, combinable with time windows |
| Time Windows per Program | Up to 10 |
| Tube Exchange Time (center-to-center) | 200–450 µs (dependent on tube diameter) |
| Program Storage | 9 full collection protocols with internal battery-backed memory |
| Interface | RS232 for LC system integration |
| Collection Modes | Time-based, drop-count-based, volume-based, and peak-triggered (UV/absorbance signal) |
| Collection Patterns | Linear (left-to-right) or spiral |
| Tube Holder Options | Compatible with 12–25 mm diameter tubes |
| Compliance | Designed for GLP-compliant chromatographic workflows |
| Brand | Laballiance |
|---|---|
| Origin | USA |
| Model | Flash 150 |
| Maximum Flow Rate | 150 mL/min |
| Maximum Pressure | 200 psi |
| Detector | VUV14 Fixed-Wavelength UV Detector (254 nm) |
| Method Storage Capacity | 10 Predefined Gradient Methods + User-Programmable Gradients |
| Fluidic Path Material | 316 Stainless Steel |
| Fraction Collection | Integrated, Trigger-Based |
| Control Unit | Dedicated Embedded System with Touchscreen Interface |
| Compliance | Designed for GLP/GMP-adjacent laboratory environments |
| Software | Standalone instrument control with real-time data logging and method export capability |
| Brand | Laballiance |
|---|---|
| Origin | USA |
| Model | R1 |
| Dimensions | 35.6 × 31.1 × 33.0 cm (H×W×D) |
| Weight | 7.7 kg (without rack) |
| Max Flow Rate | 100 mL/min |
| Delay Volume | Micro-liter level (valve positioned at outlet of flow path) |
| Communication | Ethernet (TCP/IP) & RS-232 |
| Power | 100/117 VAC or 234 VAC, 50/60 Hz |
| Rack Options | 144×12 mm tubes |
| Brand | Laballiance |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | HPLC 1500 Series |
| Price | Upon Request |
| Flow Rate Range | 0.001–10 mL/min |
| Maximum Pressure | 6,000 psi |
| Flow Accuracy | ±1% |
| Flow Precision | ≤0.075% RSD |
| Gradient Precision | ±1% |
| Spectral Bandwidth | 6 nm |
| Wavelength Accuracy | ±1.0 nm |
| Wavelength Repeatability | ±0.1 nm |
| Wavelength Range | D₂ Lamp (190–380 nm), W Lamp (366–800 nm) |
| Brand | Laballiance |
|---|---|
| Origin | USA |
| Model | HPLC 1500 |
| Flow Rate Range | 0.001–5 mL/min and 0.01–10 mL/min |
| Maximum Pressure | 6,000 psi |
| Flow Accuracy | ±1% |
| Flow Precision | ≤0.075% RSD |
| Spectral Bandwidth | 6 nm |
| Wavelength Accuracy | ±1.0 nm |
| Wavelength Repeatability | ±0.1 nm |
| Wavelength Range | 190–380 nm (D₂ lamp), 366–800 nm (W lamp) |
| UV-Vis Detector Sensitivity | 0.0005–2.0 AUFS |
| Brand | Laballiance |
|---|---|
| Origin | USA |
| Model | 201/525 |
| Wavelength Range | 190–380 nm (Model 201), 190–365 nm (Model 525) + Tungsten Lamp 366–800 nm |
| Dual-Wavelength Capability | 190–450 nm or 366–800 nm |
| Spectral Bandwidth | 6 nm |
| Wavelength Accuracy | ±1.0 nm |
| Wavelength Repeatability | ±0.1 nm |
| Noise | < ±1.0 × 10⁻⁵ AU @ 254 nm (single wavelength) |
| Absorbance Range | 0.0005–3.0 AUFS |
| Absorbance Linearity | >99% to 2.0 AU @ 254 nm |
| Optical Design | Concave holographic grating monochromator, dual-beam with fiber-optic beam splitter |
| Analog Output | Dual-channel, full-scale selectable |
| Power Supply | 220 V, 50/60 Hz |
| Dimensions | 30.5 cm W × 40.6 cm D × 17.8 cm H (12″ × 16″ × 7″) |
| Weight | 14 kg (31 lb) |
| Brand | Laballiance |
|---|---|
| Origin | USA |
| Model | 305 |
| Optical Design | Dual monochromator with concave holographic diffraction gratings |
| Excitation/Emission Wavelength Range | 200–600 nm (Ex & Em) |
| Wavelength Accuracy | ±2 nm @ 248 nm Ex / 398 nm Em |
| Wavelength Precision | <0.5 nm |
| Spectral Bandwidth Options | 8, 20, or 30 nm |
| Light Source | Pulsed xenon lamp (20 Hz or 100 Hz selectable) |
| Flow Cell | Biocompatible quartz/Teflon/Kalrez/PEEK, 8 µL detection volume, max pressure 200 psi (14 bar) |
| Sensitivity | 2 µg/L anthracene in methanol, S/N > 1500 @ 284 nm Ex / 398 nm Em |
| Scan Speed | Up to 100 steps/sec |
| step resolution | 2, 4, 8, 16, or 32 nm |
| Stored Spectra Capacity | Up to 60 emission spectra |
| Dynamic Range | 0.01–500 FUFS (Fluorescence Units Full Scale) with 15 programmable gain levels |
| Analog Output | 20-bit D/A converter, full-scale range adjustable |
| Detection Modes | Fluorescence, phosphorescence, chemiluminescence |
| Method Storage | 4 user-defined method files, each supporting up to 10 time-programmed wavelength transitions, with inter-file linking capability |
| Operating Environment | 10–40 °C, 5–95% RH (non-condensing) |
| Dimensions & Weight | 7" H × 12" W × 16" D, 24 lbs (11 kg) |
| Power Supply | 220 VAC, 50/60 Hz, max 2 A |
| Brand | Laballiance |
|---|---|
| Origin | USA |
| Model | 6000 |
| Wavelength Range | 190–800 nm |
| Optical Path Length | 5 cm |
| Flow Cell Volume | 12 µL (10 mm path) |
| Noise | ±3 × 10⁻⁶ AU/cm |
| Drift | 1 × 10⁻³ AU/hr |
| Linearity | >2.0 AU |
| Scan Rate | ≤20 Hz |
| Spectral Resolution | 1.2 nm |
| Wavelength Accuracy | ±1 nm |
| Light Source | Deuterium + Tungsten-Halogen Lamps |
| A/D Converter | 20-bit |
| Data Acquisition Rate | Configurable up to 20 Hz |
| Beam Delivery | Stacked Optical Fiber Optics |
| Compliance | ASTM E275, USP <857>, ISO/IEC 17025-aligned verification protocols |
| Brand | Laballiance |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CP |
| Pricing | Available Upon Request |
| Pump Flow Range | 1–24 mL/min |
| Maximum Pressure | 10,000 or 18,000 psi |
| Pump Control Interface | RS-232 with pressure/flow sensors |
| Construction | Stainless Steel (SS) |
| Voltage | 110/220 V AC |
| Column Hardware Included | Two 4.6 × 150 mm stainless steel column assemblies (including endfittings, frits, and 2 µm stainless steel frits) |
| Slurry Vessel | 20 mL agitated slurry reservoir |
| Packing Accessories | Compression ferrules, metal bands, reducing adapters, O-rings, 1/16″ OD × 0.03″ ID stainless steel tubing |
| Stationary Phase | 10 g C18 silica-based packing material |
| Software | Quick-Set pump control software |
| Compliance | Designed for GLP-compliant column manufacturing environments |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PC-2000 |
| Pricing | Available Upon Request |
| Maximum Pressure | 6000 psi |
| Flow Rate Range | 0.01–9.99 mL/min |
| Flow Accuracy | ±0.1% |
| Baseline Noise (UV-VIS) | 0.2 × 10⁻⁵ AU |
| Baseline Drift (UV-VIS) | 2 × 10⁻⁴ AU/hr |
| Pump Technology | SSI III Dual-Piston Positive Displacement with Patented Online Self-Cleaning Mechanism |
| Upgrade Path | Compatible with Second Pump for Binary Gradient Configuration |
| Detector Standard | Model 500 UV-Vis Variable Wavelength Detector (190–700 nm) |
| Software | LabAlliance Chromatography Data System (CDS) with Audit Trail & Electronic Signature Support per FDA 21 CFR Part 11 |
| Brand | Laballiance |
|---|---|
| Origin | USA |
| Model | PC-2000 |
| Instrument Type | Conventional High-Performance Liquid Chromatograph |
| Flow Rate Range | 0.001–40 mL/min |
| Maximum Pressure | 6000 psi |
| Sample Injection Positions | 120 |
| Injection Volume Range | 1–100 µL |
| Column Oven Temperature Range | (Ambient + 10 °C) to 99 °C |
| UV-Vis Wavelength Range | 190–800 nm |
| Data Acquisition Frequency | 100 Hz |
| Brand | Laballiance |
|---|---|
| Origin | USA |
| Model | PC2001 |
| Instrument Type | Conventional High-Performance Liquid Chromatograph |
| Flow Rate Range | 0.001–20.000 mL/min (configurable for 10 mL/min or 80 mL/min total flow via pump head interchange) |
| Maximum Pressure | 6000 psi |
| Injection Positions | 120 |
| Injection Volume Range | 1–100 µL |
| Column Oven Temperature Range | (Ambient + 10 °C) to 150 °C |
| UV-Vis Wavelength Range | 190–800 nm |
| Data Acquisition Rate | 100 Hz |
| Pressure Accuracy | ±1% of full-scale pressure |
| Flow Accuracy | ±2% |
| Flow Precision | ≤0.2% RSD |
| Baseline Noise | <±1.0×10⁻⁵ AU |
| Baseline Drift | <2.0×10⁻⁴ AU/hr |
| Wavelength Accuracy | ±1.0 nm |
| Brand | Laballiance |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Laballiance PCDS |
| Price | Upon Request |
| Pump Flow Rate | 0.01–2.5 mL/min |
| Maximum Pressure | 2500 psi |
| Flow Precision | ±0.5% RSD |
| Flow Accuracy | ±2% |
| Flow Path Material | Full PEEK |
| Temperature Control Range | Ambient +10 °C to 150 °C |
| Temperature Accuracy | ±2 °C |
| Temperature Repeatability | ±1 °C |
| Safety Cutoff Temperature | 160 °C |
| Reactor Volume Accuracy | ±5% |
| Warm-up Time to 150 °C | ≤30 min |
| Communication Interface | RS232 |
| Brand | LabAlliance |
|---|---|
| Origin | USA |
| Model | SCS-200 |
| Instrument Type | Ambient-Temperature GPC Cleanup System |
| Pump Flow Rate | 0.01–9.99 mL/min |
| Maximum Pressure | 2500 psi (pump), 1500 psi (column) |
| Flow Path Materials | 316 Stainless Steel, Ceramic, Inert Polymer |
| Injector | Adjustable 2 mL Manual Injector with Valve Position Sensing & Loop Interface |
| Column Dimensions | 250 × 16 mm (customizable) |
| Packing Material | PS-DVB Copolymer |
| Pore Size | 50 nm |
| Particle Size | 10 µm |
| Max Operating Temperature | 60 °C |
| Sample Load Capacity | 300 mg |
| Fraction Collector | Three-Position Electronic Solenoid Valve |
| Control Interface | Front-Panel SCU + RS-232 Serial Communication |
| Brand | LabAlliance |
|---|---|
| Origin | USA |
| Model | SSI/LabAlliance 340 |
| Flow Rate | Up to 40 mL/min |
| Detector | UV201 Variable Wavelength Detector with Adjustable Flow Cell (0–3 mm pathlength) |
| Pump Type | Dual-piston syringe pump with integrated low-pulse dampener |
| Sample Introduction | Rheodyne 3725(i) manual injection valve |
| Construction | Stainless steel fluidic path |
| Compliance | Designed for GLP-compliant preparative workflows |
| Software Control | Fully automated system control via dedicated chromatography software |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | WA2002SF |
| Pricing | Available Upon Request |
| Origin | Denmark |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LabFlicker |
| Dimensions (L × W × H) | 115 × 53 × 13 mm |
| Weight | 0.16 kg |
| Shipping Dimensions (L × W × H) | 170 × 130 × 70 mm |
| Shipping Weight | 0.5 kg |
| Warranty | 2 years |
| Software Integration | Light Inspector (Viso Systems) |
| Output Metrics | Flicker Percentage, Flicker Index, Flicker Frequency, SVM (Stroboscopic Visibility Measure), PstLM (Short-Term Flicker Indicator per IEC TR 61547-1), JA8 §24 Compliance Data |
| Data Export | CSV & Excel-compatible arrays |
| Real-time Signal Processing | Onboard intelligent algorithm engine |
| Brand | GRACE |
|---|---|
| Origin | Germany |
| Model | RI 2000 |
| Detection Principle | Differential Refractometry |
| Refractive Index Range | 1.00–1.75 |
| Flow Rate Range | 0.2–3.0 mL/min |
| Linear Range | 80 × 10⁻⁵ RIU |
| Noise Level | 5 × 10⁻¹⁰ RIU |
| Auto-Zero Range | 40 × 10⁻⁵ RIU |
| Auto-Zero Resolution | 5 × 10⁻¹⁰ RIU |
| Integrator Output | ±1 V |
| Recorder Output | ±10 V |
| Analog Input Range | −5 to +5 V DC |
| Temperature Setpoints | Ambient, 35 °C, or 55 °C (microprocessor-controlled) |
| Flow Cell Volume | 9 µL |
| Maximum Flow Cell Pressure | 6 kg/cm² |
| Brand | Labman |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Electrochemical Workstation |
| Model | LABMAN 64-Channel Potentiostat System |
| Channel Count | 64 independent electrochemical channels |
| Current Range | ±1 A per channel |
| Current Accuracy | ±1% of full scale |
| Potential Accuracy | ±1 mV (typical, referenced to internal calibration standard) |
| Potentiostatic Range | ±10 V vs. reference electrode |
| AC Impedance Frequency Range | 1 Hz – 1 MHz (per channel, with optional frequency extension modules) |
| Compliance | CE-marked, RoHS-compliant, designed for integration into GLP/GMP-regulated laboratory automation platforms |
| Brand | Labman |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | LABMAN High-Throughput Automated Absorbance Measurement System |
| Optical Design | Dual-Beam |
| Detector | CCD (Charge-Coupled Device) |
| Wavelength Range | 190–900 nm |
| Wavelength Selection | Manual |
| Spectral Bandwidth | 650 nm |
| Wavelength Accuracy | ±2.0 nm |
| Stray Light | ≤0.01% T |
| Sample Capacity | 192-position rack (17 mm height, dual-diameter transparent glass vials) |
| Throughput | Up to 180 samples/hour |
| Scan Speed | ≥12 vials/minute |
| LED Source | Red 4-element array @ 650 nm |
| Brand | Labman (formerly LABA Tianjin) |
|---|---|
| Model | LB8120 |
| Detector Type | Ultraviolet-Visible Absorbance Detector |
| Wavelength Range | 190–900 nm |
| Optical Design | Dual-Beam with Shielded Optics |
| Light Source | Deuterium Lamp |
| Grating Type | Holographic Concave Grating |
| Detection Mode | Programmable Dual-Wavelength Simultaneous Monitoring |
| Spectral Acquisition | Continuous Rapid Scanning |
| Lamp Control | Fully Automated Start/Stop with Warm-up Optimization |
| Origin | USA-assembled with global supply chain integration |
| Compliance | Designed to support GLP/GMP workflows and ASTM E260, ISO 17025-aligned operation |
| Brand | Labman |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | LBI860 |
| Pricing | Available Upon Request |
| Brand | JAI |
|---|---|
| Origin | Japan |
| Model | LaboACE LC7080 |
| Application Level | Laboratory-grade |
| Instrument Type | Medium-to-Low Pressure Preparative LC |
| Flow Rate Range | 0.1–80.0 mL/min |
| Flow Accuracy | CV < 0.3% |
| Flow Precision (Repeatability) | CV < 0.3% |
| Maximum Operating Pressure | 20 MPa |
| Wavelength Range | 190–700 nm |
| Wavelength Repeatability | ±0.5 nm |
| Baseline Noise | ≤0.00005 AU (at 254 nm, 1 s time constant) |
| Data Acquisition Rate | 50–100 Hz |
| Footprint | 382 mm (W) × 432 mm (D) |
| Recycling Capability | Fully Automated Solvent-Saving Loop Mode with Real-Time Fraction Re-injection Logic |
| Brand | Labomatic |
|---|---|
| Origin | Switzerland |
| Type | Dynamic Axial Compression (DAC) System |
| Construction Material | Borosilicate Glass |
| Max Operating Pressure | 65 bar (940 psi) |
| Piston Adjustment Range | 150 mm |
| Column Diameter Options | 8 sizes (28–300 mm) |
| Column Length Options | 3 standard lengths |
| Seal Design | Spring-loaded elastomeric seals |
| Sample Distribution | Optimized distributor for improved packing reproducibility |
| Compatibility | Biocompatible inert materials |
| Modular Conduit System | Shared tubing manifold for multi-column operation |
| Packing Tool Kits | Available for all AMC column diameters |
| Regulatory Context | Designed for GLP-compliant preparative chromatography workflows |
| Brand | Labomatic |
|---|---|
| Origin | Switzerland |
| Model | LH3000 |
| Instrument Type | HPLC Autosampler |
| X-axis Travel Range | 160–2800 mm (customizable) |
| Y-axis Travel Range | 70–670 mm (single arm) |
| Z-axis Height Range | 130–780 mm (fixed base height), max vertical stroke: 400 mm |
| Compliance | Designed for GLP/GMP environments |
| Brand | Labomatic |
|---|---|
| Origin | Switzerland |
| Model | LHP3000 / LMP3000 |
| Instrument Type | High-Pressure Preparative LC System |
| Pump Flow Range | 0.2–1640 mL/min |
| Max Pressure | 600 bar (HDK-51) to 150 bar (HDK-1640) |
| Flow Stability | RSD < 0.1% |
| Piston Stroke | 3.2–17.1 mm |
| Piston Frequency | 0–200 cycles/min |
| Wetted Materials | Sapphire, Ruby, Zirconia Ceramic, PEEK, 1.4435 Stainless Steel |
| Power Supply | 110 / 230 V, 50 / 60 Hz, 1200 VA |
| Dimensions (Controller) | 316 × 142 × 400 mm (W × H × D) |
| Dimensions (Pump Unit) | 316 × 198 × 400 mm |
| Interface Options | 1/4″, 1/8″, 1/16″ |
