Chemical Analysis Instruments
Filter
Showing 5041–5070 of 10669 results
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | TrueX 860 |
| Application | Handheld / Portable |
| Instrument Type | General-Purpose ED-XRF Spectrometer |
| Industry-Specific Use | Non-Ferrous Metals |
| Elemental Range | Mg (12) to U (92) |
| Detection Limit | Sub-ppm to ppm level (matrix-dependent) |
| Compliance | CE, RoHS, FCC, ISO 17025-aligned operation |
| Weight | <1.5 kg |
| Battery Life | ≥8 hours typical usage |
| Safety | Automatic beam shutter, radiation interlock, real-time dose monitoring per IEC 62495 |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Portable/Handheld ED-XRF |
| Models | TrueX 880, TrueX 880S, TrueX 980, TrueX 980S |
| Elemental Range | Mg to U |
| Detection Limit | 1 ppm |
| Quantitative Range | 1 ppm – 99.99 wt% |
| Energy Resolution | <140 eV (at Mn Kα) |
| Repeatability | ±0.1% RSD (for major elements under standardized conditions) |
| Compliance | CE, RoHS, ISO 12885, ASTM E1621, ASTM E2857 |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | TrueX G7 |
| Price Range | USD 14,000 – 42,500 |
| Form Factor | Handheld / Portable |
| Instrument Type | Benchtop-Portable Hybrid ED-XRF |
| Industry-Specific Design | Non-Ferrous & Precious Metals |
| Elemental Range | Al (13) to U (92) |
| Detection Limit | Sub-ppm to % level (matrix-dependent) |
| Compliance | CE, RoHS, FCC Class B |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | TX3000 Series (Portable) |
| Instrument Type | Total Reflection XRF (TXRF) |
| Application Scope | Soil & Atmospheric Analysis |
| Sample Form Compatibility | Liquid, Suspension, Solid, Particulate Deposits |
| Regulatory Alignment | Compliant with ISO 8519, ASTM D7706 (for trace metal analysis in environmental matrices), GLP-ready data handling |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | TX3000 Series |
| Configuration | Handheld / Portable |
| Instrument Type | Total-Reflection X-Ray Fluorescence (TXRF) |
| Application Domain | Soil & Atmospheric Analysis |
| Compliance Context | ASTM D6919, ISO 17294-2, USP <232>/<233>, EPA Method 6020B (adapted for field TXRF) |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | TX3000 |
| Application | Portable/Field-Deployable |
| Instrument Type | Total Reflection XRF (TXRF) |
| Industry-Specific Use | Soil & Atmospheric Analysis |
| Elemental Range | Mg (12) to U (92) |
| Detection Range | 30 ppb – 100 ppm |
| Detector | 20 mm² Silicon Drift Detector (SDD) |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Line | TX3300 Series |
| Instrument Type | Total Reflection X-Ray Fluorescence (TXRF) |
| Application Form Factor | Handheld / Portable |
| Elemental Range | Mg (12) to U (92) |
| Detection Limit | 20 pg/mL (ppb) in liquid matrix |
| Sample Consumption | ≤ 10 µL per analysis |
| Detector | 20 mm² Silicon Drift Detector (SDD) |
| Industry Focus | Energy & Chemicals |
| Compliance Context | Designed for GLP-compliant trace metal quantification in regulated environmental and industrial labs |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | TX3300 |
| Application | Portable/Field-Deployable |
| Instrument Type | Total Reflection X-Ray Fluorescence (TXRF) |
| Elemental Range | Mg (12) to U (92) |
| Detection Limit | 20 pg/mL (ppb) in liquid matrix |
| Detector | 20 mm² Silicon Drift Detector (SDD) |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Model | TX3300Cl |
| Application | Handheld/Portable |
| Instrument Type | Total-Reflection X-Ray Fluorescence (TXRF) |
| Industry-Specific Use | Energy & Chemical Engineering |
| Elemental Range | Mg (12) to U (92) |
| Detection Range | 0.3 ppm – 100 ppm |
| Detector | Silicon Drift Detector (SDD) |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | TX3300TI |
| Application | Handheld/Portable |
| Instrument Type | Total Reflection X-Ray Fluorescence (TXRF) Spectrometer |
| Industry-Specific Use | Energy & Chemical Engineering |
| Detection Limit | Sub-ppb (ng/L) for Thallium |
| Sample Volume | Microliter-scale (μL) |
| Analysis Time | ≤2 min per sample (no digestion, no calibration required) |
| Optical Design | High-efficiency TXRF geometry with ultra-low background |
| Compliance Support | Designed for ASTM D8139, ISO 17294-2, and China’s HJ 657–2013 |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Total Reflection XRF (TXRF) |
| Element Range | Mg–U |
| Detection Limit | 0.1 ppb – 100 ppm |
| Detector | 65 mm² Silicon Drift Detector (SDD) |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | YANG 700 |
| Pricing | Upon Request |
| Brand | LANTIAN |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Model | AOX-WK-3 Microcoulometric Halogen Analyzer |
| Detection Principle | Microcoulometric Titration after High-Temperature Combustion (900–1100 °C) |
| Applicable Standards | GB/T 34845–2017, GB/T 22904–2008, GB/T 35613–2017, GB/T 39084–2020, GB/T 35611–2017, GB/T 41533–2022 |
| Detection Target | Adsorbable Organic Halogens (AOX), expressed as Cl⁻ |
| Detection Limit | 2 mg/kg |
| Quantification Range | 0.5–5 mg/kg (Cl) |
| Precision | ±1 µg Cl |
| Repeatability | ≤10% RSD at ≤2 mg/L sample concentration |
| Combustion Temperature Control | 500–1100 °C, ±1 °C accuracy |
| Generator Current Range | ±2 mA |
| Amplifier Output Voltage | ±30 V |
| Bias Voltage Adjustment | 0–500 mV, continuously adjustable |
| Sample Introduction | 50 mg ±5 mg activated carbon cartridge |
| Power Supply | AC 220 V ±10%, 50 Hz ±0.5 Hz |
| Rated Power | 3000 W |
| Interface | RS-232 (DB9) |
| Software Platform | Windows-based proprietary AOX analysis suite with real-time parameter monitoring, data logging, audit trail, and report generation (PDF/CSV export) |
| Brand | LANTIAN |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Model | AOX-WK-S |
| Compliance Standard | HJ 1214–2021 (PRC National Ecological and Environmental Standard) |
| Generator Current Range | ±2 mA |
| Amplifier Output Voltage | ±30 V |
| Bias Voltage Adjustment Range | 0–500 mV (continuously adjustable) |
| Detection Limit | 0.007 µg/L (at 100 mL sample volume) |
| Measurement Range (as Cl) | 0.02–2 mg/kg |
| Accuracy | ±1 µg Cl |
| Repeatability | ≤10% RSD (for samples ≤2 mg/L) |
| Activated Carbon Dosage | 50 mg ±5 mg |
| Combustion Temperature Control Range | 500–1100 °C |
| Stability | ±1 °C |
| Power Supply | AC 220 V ±10%, 50 Hz ±0.5 Hz |
| Rated Power | 3000 W |
| Brand | LANTIAN |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Model | AOX-WK-S |
| Detection Principle | Microcoulometric Titration after High-Temperature Combustion |
| Compliance | HJ 1214–2021 (China National Standard) |
| Maximum Generator Current | ±2 mA |
| Amplifier Output Voltage | ±30 V |
| Bias Voltage Range | 0–500 mV (continuously adjustable) |
| Detection Limit | 0.007 µg/L (at 100 mL sample volume) |
| Optimal Measurement Range (as Cl) | 0.02–2 mg/kg |
| Precision | ≤10% RSD (for samples ≤2 mg/L) |
| Activated Carbon Loading | 50 mg ±5 mg |
| Combustion Temperature Range | 500–1100 °C (±1 °C accuracy) |
| Power Supply | AC 220 V ±10%, 50 Hz ±0.5 Hz |
| Rated Power | 3000 W |
| Brand | LANTIAN |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Model | AOX-WK-S |
| Compliance Standard | HJ 1214–2021 |
| Detection Principle | Microcoulometric Titration |
| Max Generator Current | ±2 mA |
| Amplifier Output Voltage | ±30 V |
| Bias Voltage Range | 0–500 mV (continuously adjustable) |
| Detection Limit | 0.007 mg/L (at 100 mL sample volume) |
| Optimal Measurement Range (as Cl) | 0.02–2 mg/kg |
| Accuracy | ≤10% relative deviation (at 1 µg Cl) |
| Repeatability | ≤10% RSD (for samples ≤2 mg/L) |
| Activated Carbon Dosage | 50 mg ±5 mg |
| Combustion Temperature Range | 500–1100 °C (±1 °C control accuracy) |
| Power Supply | AC 220 V ±10%, 50 Hz ±0.5 Hz |
| Rated Power | 3000 W |
| Brand | LANYO |
|---|---|
| Model | SOMA Series |
| Standard Compliance | NY/T 1121.6–2006, NY/T 85–1988, LY/T 1237–1999, GB/T 33469–2016 Annex C |
| Heating Stations | 3 independent micro-boiling reflux positions with PID temperature control |
| Reagent Dispensing Accuracy | ≤0.3% (v/v) |
| Titration Endpoint Detection | Biomimetic colorimetric endpoint recognition |
| Reagent Port | 1 dedicated channel with isolated fluid path |
| Tube Cleaning | Programmable pre-run automated line rinse and conditioning cycle |
| Software Interface | Integrated GUI with real-time process logging, CSV export, and LIMS-compatible data transmission protocol |
| Safety | Fully enclosed reagent handling |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LARRY-USB3648 |
| Pricing | Available Upon Request |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LBC-2 |
| Instrument Type | Benchtop |
| Integration | Fully Integrated |
| Laser Power | 10 mW |
| Laser Wavelength (Standard) | 532 nm |
| Spatial Resolution | 10 µm |
| Scan Area | 50 mm × 50 mm |
| Current Measurement Range | 10 fA – 20 mA |
| XY Stage Travel | ±25 mm (0.01 mm minimum step) |
| Laser Stability | ±5% / h |
| Laser Class | Class 2 (IEC 60825-1) |
| Operating System | Windows 7 (32-bit) |
| Dimensions (W×D×H) | 750 mm × 270 mm × 650 mm (excl. electrometer, stage controller, and PC) |
| Brand | Laser Components |
|---|---|
| Model | IG26 Series |
| Detector Type | PIN Photodiode |
| Cutoff Wavelength | 2.6 µm |
| Spectral Range | 0.8–2.6 µm |
| Typical Responsivity @ 2.0 µm | 1.45 A/W |
| Operating Temperature | −40 °C to +85 °C (TE-cooled variants available) |
| Shunt Resistance | >10⁹ Ω (typ. at 0 V, 25 °C) |
| Dark Current | <10 nA (typ. at −5 V, 25 °C) |
| Capacitance | <20 pF (typ. at −5 V, 25 °C) |
| Active Area Options | 0.05–1.0 mm² |
| Package | TO-8, TO-46, or OEM hermetic ceramic |
| Brand | TELTEC / Teltec Semiconductor Pacific Limited |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Laser Decap |
| Pricing | Available Upon Request |
| Brand | Lasertec |
|---|---|
| Origin | Japan |
| Model | GT-200 |
| Instrument Type | General-purpose Potentiometric Titrator |
| Application Scope | Specialized (e.g., Acid Number Determination in Gasoline) |
| Display | 5.7-inch Color LCD |
| Connectivity | USB, RS-232 (COM), GLP-compliant Data Logging |
| Software | Titration Viewer TV-200 |
| Automation Capacity | Up to 12 burettes + 24-position autosampler |
| Endpoint Detection | Smart End Point Detection (S.E.D.) Algorithm |
| Compliance | GLP Support (Calibration Traceability, User Access Levels, Audit Trail) |
| Brand | Hefei Kejing |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | PRC |
| Model | LaSrAlO4 |
| Crystal Structure | Tetragonal |
| Lattice Parameters | a = 3.756 Å, c = 12.636 Å |
| Melting Point | 1650 °C |
| Density | 5.92 g/cm³ |
| Dielectric Constant (εᵣ) | 16.8 |
| Growth Method | Czochralski (Cz) |
| Standard Orientations | <001>, <100> |
| Orientation Tolerance | ±0.5° |
| Typical Dimensions | 10 × 10 × 0.5 mm³, 10 × 5 × 0.5 mm³ |
| Surface Finish | Single- or Double-Polished, Ra < 0.5 nm |
| Packaging | Class 1000 Cleanroom / Class 100 Clean Bag |
| Brand | JWGB (Jingwei Gaobo) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | Lattice GO |
| Instrument Type | Powder X-ray Diffractometer |
| Instrument Configuration | Portable |
| X-ray Tube Power | 30 W |
| Angular Accuracy | ±0.01° |
| Angular Resolution | 0.2° |
| Dimensions (L×W×H) | 120 mm × 300 mm × 305 mm |
| Weight | 12 kg |
| X-ray Tube | Cu anode, 30 kV / 1 mA |
| Goniometer Geometry | Vertical θ–2θ Bragg–Brentano |
| Goniometer Radius | 110 mm |
| Detector | Photon-counting 2D array detector |
| Scan Speeds | 6°/min or 13°/min (selectable) |
| 2θ Range | 0°–130° |
| Battery Runtime | 3 hours |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | LC-06 |
| Price Range | USD 28,000 – 70,000 |
| Instrument Type | Single-Crystal X-ray Diffractometer |
| Angular Resolution | < 0.05° |
| Effective Detection Area | 30 cm × 30 cm |
| Data Acquisition Time | Seconds per Laue Pattern |
| Gas Replacement Interval | Every 6 months |
| Coolant Replacement Interval | Annually |
| Sample Rotation Capability | Yes |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | FlameMaster Raman |
| Instrument Type | Grating-Based Raman Spectrometer |
| Spectral Range | 300–800 nm |
| Spectral Resolution | 1 cm⁻¹ |
| Spatial Resolution | 1 mm |
| Minimum Wavenumber Shift | 10 cm⁻¹ |
| Spectral Reproducibility | ±0.15 cm⁻¹ |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | FluidMaster-Multi Phase |
| Wavelength Accuracy | ±2.0 nm |
| Spectral Bandwidth (Slit) | 1.5–20 nm |
| Optical Resolution | 1.0 nm |
| Sensitivity | 1% |
| Dispersive Elements | Grating and Interference Filters |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | FluidMaster-Thermal |
| Dispersion Unit | Grating and Interference Filters |
| Slit Width (Spectral Bandpass) | 1.5 nm – 20 nm |
| Spectral Resolution | 1.0 nm |
| Sensitivity | 1% |
| Wavelength Accuracy | ±2.0 nm |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LBC-2 |
| Price Range | USD 70,000 – 112,000 |
| Instrument Type | Benchtop |
| Integration | Fully Integrated System |