| Brand | NorECs |
|---|---|
| Origin | Norway |
| Model | ProboStat |
| Instrument Type | Electrochemical Sample Holder |
| Operating Temperature (Long-term) | Up to 1400 °C |
| Operating Temperature (Short-term) | Up to 1600 °C |
| Sample Geometry | Disc-shaped (Ø 10–24 mm, thickness 25–50 mm) or Rod-shaped (Ø up to 24 mm, length 30–1500 mm) |
| Electrode Configurations | 2-, 3-, or 4-electrode setups |
| Gas Environment | Oxidizing, inert, reducing, corrosive, humid/dry |
| pressure range | 10⁻² mbar to 1 bar (up to 25 bar in sealed steel tube) |
| Dual-chamber capability | Yes |
| Van der Pauw measurement | Supported (4-point) |
| Seebeck coefficient measurement | Supported (rod geometry) |
| Electrical measurements | DC conductivity, impedance spectroscopy, polarization, dielectric breakdown (HV version), concentration cell, transference number, permeability, fuel cell testing |
| Brand | North Branch Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (PRC) |
| Model | GC-8000 |
| Pricing | Available Upon Request |
| Brand | North Branch Sanpu |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Model | SF-1 |
| Measurement Principle | Coulometric Karl Fischer (KF) Titration |
| Detection Range | 3 µg – 100 mg H₂O |
| Resolution | 1 µg H₂O |
| Accuracy | ±3 µg H₂O (≤1 mg), ±0.3% of reading (>1 mg) |
| Electrolysis Current | 0–300 mA, auto-controlled |
| Display | 4-digit high-brightness LED |
| Endpoint Indication | Audible alert + visual LED indicator |
| Drift Compensation | Microprocessor-based automatic compensation |
| Stirring | Continuously variable speed control |
| Power | AC 220 V ±11 V, 50 Hz ±2.5 Hz |
| Dimensions | 320 mm × 260 mm × 90 mm |
| Weight | Approx. 4.2 kg |
| Operating Temperature | 5–45 °C |
| Relative Humidity | ≤80% RH (non-condensing) |
| Brand | North Point |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automated |
| Oven Temperature Range | Ambient to 200 °C (1 °C increment) |
| Valve & Transfer Line Temperature Range | Ambient to 200 °C (1 °C increment) |
| Sample Loop Volume | 1 mL |
| Temperature Control Accuracy | ±0.1 °C |
| Sample Tray Capacity | 12 / 24 / 30 positions |
| Vial Sizes Supported | 10 mL and 20 mL standard (custom sizes available) |
| Brand | North分Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | AHS-610 Headspace Autosampler + Thermo TRACE 1300 GC |
| Temperature Control Range | 400 °C |
| Heating Rate | 40 °C/min |
| Cooling Rate | from 450 °C to 50 °C in ~5 min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–16 psi |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | North分Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Two-Stage Thermal Desorber |
| Primary Desorption Temp Range | Ambient to 400 °C |
| Secondary Desorption Temp Range | 100–400 °C |
| Cryo-Trap Temp Range | Down to −35 °C |
| Desorption Recovery Rate | >90% |
| Sample Capacity | 20 positions |
| Brand | Novocontrol Technologies |
|---|---|
| Origin | Germany |
| Model | NEISYS |
| Frequency Range | 3 µHz – 100 MHz |
| Sampling Rate | 10⁷ points/sec |
| Impedance Range | 10⁻⁴ Ω – 1 TΩ |
| Loss Factor Accuracy | ±1×10⁻⁴ |
| Architecture | Four-Electrode, Separated Current/Voltage Signal Paths |
| Thermal Expansion Option | Yes |
| Operating Modes | Frequency-Domain (EIS, Dielectric, Conductivity, Loss Tangent) & Time-Domain (CV, LSV, SWV, CA, CP, Galvanostatic/Potentiostatic Cycling, Battery Charge/Discharge, Capacitor Charging/Discharging) |
| Compliance Support | ASTM D257, ISO 60270, IEC 60601-2-60 (for dielectric safety), GLP/GMP-ready data audit trail |
| Brand | NOVONIX |
|---|---|
| Origin | Canada |
| Model | UHPC |
| Channel Configuration | Multi-channel Electrochemical Workstation |
| Current Ranges | 200 μA, 2 mA, 20 mA, 200 mA, 2 A |
| Current Accuracy | ±0.005% of Full-Scale Reading (FSR) |
| Potential Accuracy | ±100 μV + 0.01% of FSR |
| Potentiostatic Range | 0–5 V |
| Stability (Typical) | <10 ppm |
| Accuracy (Typical) | <50 ppm |
| Brand | NOY |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop |
| Detection Method | Vacuum Mode |
| Minimum Detectable Leak Rate | 3×10⁻¹³ Pa·m³/s |
| Pump-down & Startup Time | ≤90 s |
| Response Time | ≤0.5 s |
| Maximum Inlet Pressure at Test Port | ≤2000 Pa |
| Brand | NOY |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop |
| Detection Method | Vacuum Mode (also supports Sniffer Mode) |
| Minimum Detectable Leak Rate | 3×10⁻¹³ Pa·m³/s |
| Startup Time | ≤100 s |
| Response Time | ≤0.5 s |
| Maximum Inlet Pressure (for Vacuum Mode) | ≤2000 Pa |
| Leak Rate Display Range | 1×10⁻² to 1×10⁻¹³ Pa·m³/s (Vacuum Mode) |
| Dimensions | 420 × 275 × 359 mm |
| Weight | 26 kg |
| Ion Source | Dual Iridium Filament |
| Mass Analyzer | 180° Non-Uniform Magnetic Sector (U-Shaped Magnet) |
| Brand | NOY |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Benchtop |
| Detection Method | Vacuum Mode |
| Minimum Detectable Leak Rate | 3×10⁻¹³ Pa·m³/s |
| Warm-up Time | ≤90 s |
| Response Time | ≤0.5 s |
| Maximum Inlet Pressure | ≤2000 Pa |
| Leak Rate Display Range | 1×10⁻² to 1×10⁻⁹ Pa·m³/s (zero-referenced) |
| Brand | NOY |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | NHJ600 |
| Instrument Type | Portable |
| Detection Method | Vacuum Mode |
| Minimum Detectable Leak Rate | 3×10⁻¹³ Pa·m³/s |
| Startup Time | ≤90 s |
| Response Time | ≤0.5 s |
| Maximum Pressure at Test Port | ≤2000 Pa |
| Leak Rate Display Range | 1×10⁻² to 1×10⁻¹³ Pa·m³/s |
| Brand | NOY |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | NHJ800D |
| Instrument Type | Portable |
| Detection Method | Vacuum Mode |
| Minimum Detectable Leak Rate | 3×10⁻¹³ Pa·m³/s |
| Startup Time | ≤90 s |
| Response Time | ≤0.5 s |
| Maximum Inlet Pressure | ≤2000 Pa |
| Leak Rate Display Range | 1×10⁻² to 1×10⁻¹³ Pa·m³/s |
| Brand | NOY |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop |
| Detection Method | Vacuum Mode |
| Minimum Detectable Leak Rate | 5×10⁻¹³ Pa·m³/s |
| Startup Time | ≤90 s |
| Response Time | ≤0.5 s |
| Maximum Pressure at Test Port | ≤2000 Pa |
| Leak Rate Display Range | 1×10⁻² to 1×10⁻⁹ Pa·m³/s |
| Brand | NOY |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop |
| Detection Method | Vacuum Mode |
| Minimum Detectable Leak Rate | 3×10⁻¹³ Pa·m³/s |
| Warm-up Time | ≤90 s |
| Response Time | ≤0.5 s |
| Maximum Inlet Pressure | ≤2000 Pa |
| Ion Source | Dual Iridium Filament |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | NP330-G |
| Price Range | USD 7,000–14,000 |
| Product Type | Online Dew Point Analyzer |
| Measurement Principle | Aluminum Oxide (Al₂O₃) Capacitive Sensor |
| Operating Temperature | −20 °C to +60 °C |
| Accuracy | ±2 °C |
| Repeatability | ±0.5 °C |
| Dew Point Range (Standard) | −80 °C to +20 °C |
| Optional Range | −100 °C to +20 °C |
| Sample Gas Temperature Limit | ≤ +60 °C |
| Pressure Rating | Up to 300 bar |
| Recommended Flow Rate | 1–5 L/min |
| Power Supply | 18–28 VDC, max. 70 mA |
| Enclosure Rating | IP65 |
| Filter | 80 µm Stainless Steel Sintered |
| Sensor Thread | G1/2″, Insertion Depth: 50 mm |
| Calibration Interval | Annual |
| Sensor Dimensions | Ø60 mm × 115 mm (height), Total Length: 176 mm |
| Weight | ~450 g |
| Transmitter Housing | 96 mm (W) × 48 mm (H) × 112 mm (L), Horizontal Panel Mount |
| Display | Red LED |
| Analog Input/Output | 4–20 mA (isolated) |
| Loop Power | 24 VDC |
| Main Enclosure | 400 mm (W) × 500 mm (H) × 250 mm (D), Carbon Steel with Powder Coating, Lockable Door |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | NP7001 |
| Price Range | USD 14,000–28,000 (FOB) |
| Instrument Type | Conventional High-Performance Liquid Chromatograph (HPLC) Pump |
| Flow Mode | Dual-Piston Serial Configuration |
| Flow Range | 0.001–9.999 mL/min |
| Flow Increment | 0.001 mL/min |
| Flow Accuracy | ≤0.5% or ≤10 µL/min |
| Flow Precision (RSD) | ≤0.1% |
| Pressure Pulsation | ≤0.5 MPa |
| Maximum Operating Pressure | ≤42 MPa |
| Tubing Connection | 1/16″ Stainless Steel Standard Fittings |
| Display | 4.7″ LCD (320 × 240 pixels), Tab-Based UI |
| User Programs | 10 Predefined Methods |
| Gradient Capability | Linear Flow Gradient Programming |
| Communication Protocol | Open ASCII-Based RS-232/RS-485 Protocol (Third-Party Software Compatible) |
| Maintenance Feature | Optional Automatic Back-Flush Mechanism for Piston Seal and Rear Seal Area |
| Sealing Architecture | Floating Piston Design with Extended Seal Life |
| Flow Damping | Integrated Electronic Pulse Damping Control |
| Calibration | Multi-Point Flow Calibration Curve (Spanning Full Range) |
| Brand | NU |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Astrum ES |
| Pricing | Available Upon Request |
| Brand | Nu Instruments |
|---|---|
| Origin | United Kingdom |
| Model | Nu AttoM ES |
| Type | Double-Focusing Magnetic Sector ICP-MS |
| Detector System | Wide Dynamic Range Faraday + Secondary Electron Multiplier (SEM) |
| Resolution Mode | Adjustable High-Resolution Slit (Fixed Width, Vertically Movable) |
| Primary Application | Isotope Ratio Analysis & Ultra-Trace Elemental Quantification in Geochemical and Environmental Matrices |
| Brand | NU |
|---|---|
| Origin | United Kingdom |
| Model | Perspective |
| Instrument Type | Stable Gas Isotope Ratio Mass Spectrometer |
| Mass Dispersion | Up to 600 mm |
| Mass Resolution (m/Δm) | >200 for CNOS and H |
| Collector Configuration | Up to 12 fixed, high-precision Faraday and/or multi-collector arrays |
| Ion Source | High-efficiency electron impact ion source |
| Optics | Patented zoom optics system |
| Compatible Interfaces | NU Dual Inlet, NU GasBench, NU Carbonate Device |
| Brand | NU |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported Instrument |
| Model | Nu Sapphire |
| Instrument Type | Multi-Collector ICP-MS |
| Isotope Measurement Capability | Fe, Cu, Hf, U, Pb, Nd, K, Ca, and other elements |
| Mass Range | 1–300 u |
| Resolution (M/ΔM) | 350–10,000 |
| Precision | Element- and isotope-dependent |
| Ion Optics Architecture | Dual-path: high-energy conventional MC-ICP-MS path + low-energy collision/reaction cell path |
| Brand | NU |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Vitesse |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | 35425-05 |
| Price Range | USD 70–700 (FOB) |
| Measured Parameters | pH, Conductivity, TDS, Salinity, Temperature |
| Portability | Handheld / Pen-style |
| Conductivity Range | 0–200 µS/cm |
| TDS Range | 0–100 ppm |
| Resistivity Range | 0–100 kΩ·cm |
| Salinity Range | 0–100 ppm (NaCl equivalent) |
| Temperature Range | 10–110 °C |
| Accuracy | ±0.2% of reading |
| Minimum Resolution | 0.001 unit (context-dependent per parameter) |
| Brand | OBLF |
|---|---|
| Origin | Germany |
| Model | OBLF GS1000 II |
| Instrument Type | Floor-standing |
| Excitation Method | Spark |
| Detector Type | Photomultiplier Tube (PMT) |
| Focal Length | 500 mm |
| Grating Groove Density | 2700 lines/mm |
| Wavelength Range | 120–780 nm |
| Number of Channels | 32 |
| Brand | OBLF |
|---|---|
| Origin | Germany |
| Instrument Type | Floor-Standing |
| Excitation Method | Spark |
| Detector Type | Photomultiplier Tube (PMT) |
| Focal Length | 750 mm |
| Grating Groove Density | 2400 lines/mm |
| Wavelength Range | 120–800 nm |
| Number of Channels | 64 |
| Brand | OBLF |
|---|---|
| Origin | Germany |
| Model | QSN/G 750-II R |
| Instrument Type | Floor-Standing |
| Excitation Method | Spark Discharge |
| Detector Type | Photomultiplier Tube (PMT) |
| Focal Length | 750 mm |
| Grating Groove Density | 2400 lines/mm |
| Wavelength Range | 120–800 nm |
| Number of Simultaneous Channels | 64 |
| Brand | OBLF |
|---|---|
| Origin | Germany |
| Model | QSN750-II |
| Instrument Type | Floor-standing |
| Excitation Method | Spark |
| Detector Type | Photomultiplier Tube (PMT) |
| Focal Length | 750 mm |
| Grating Groove Density | 2400 lines/mm |
| Wavelength Range | 190–780 nm |
| Number of Analytical Channels | 60 |
| Optical Resolution (1st Order) | 0.55 nm/mm |
| Vacuum Pump Duty Cycle | <5% of total operating time |
| Spark Frequency | Up to 1000 Hz |
| Analysis Time (Steel Sample) | ~15 s |
| Operating Temperature | 12–35 °C |
| Dimensions (L×W×H) | 1040 × 900 × 1300 mm |
| Weight | 550 kg |
| Brand | OBLF |
|---|---|
| Origin | Germany |
| Model | OBLF VeOS |
| Instrument Type | Floor-Standing |
| Excitation Method | Spark |
| Detector Type | Charge-Coupled Device (CCD) |
| Focal Length | 500 mm |
| Grating Groove Density | 2700 lines/mm |
| Wavelength Range | 120–800 nm |
| Number of Detection Channels | 128 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Blue Series |
| Spectral Range | 200–1100 nm |
| Detector | CCD (2048-pixel linear array) |
| Optical Resolution (FWHM) | 0.13–6.0 nm (dependent on grating and slit configuration) |
| Sensitivity | 100 photons/count at 400 nm |
| Signal-to-Noise Ratio | 1000:1 (full well, 1 s integration) |
| Dynamic Range | 2000:1 (6 decades) |
| Stray Light | <0.1% at 435 nm |
| Interface | USB 2.0, SMA905 fiber input, 16-bit ADC |
| Integration Time | 1 ms – 65 s |
| Grating Options | 300–2400 g/mm (holographic & ruled) |
| Slit Options | 14–200 µm |
| Focal Ratio | f/4 |
| Optical Design | Symmetric Czerny–Turner with crossed-beam geometry |
| Power Supply | <100 mA via USB port |
| Dimensions | 25.4 × 76.2 × 127 mm (1 × 3 × 5 in) |
| Weight | 397 g (14 oz) |
| Brand | Ocean Insight |
|---|---|
| Origin | USA |
| Model | FLAME-S / FLAME-T |
| Spectral Range | 190–1100 nm |
| Detector Type | CMOS (back-thinned or standard, model-dependent) |
| Optical Resolution (FWHM) | Configurable via slit width and grating selection |
| Sensitivity | Configuration-dependent (e.g., UV-enhanced or NIR-optimized) |
| Signal-to-Noise Ratio | 250:1 (full signal, 10 ms integration) |
| 300 | 1 (with on-chip binning) |
| Dynamic Range | 8.5 × 10⁷ (system, with 16-bit ADC and multi-integration) |
| Stray Light | <0.05% at 600 nm |
| Dimensions | 89.1 × 63.3 × 34.4 mm |
| Weight | 265 g |
| Interface | USB 2.0 (micro-B), no external power required |
| Operating Temperature | 0–40 °C |
| Thermal Drift | <0.03 nm/°C (typical, with onboard thermal stabilization) |