Chemical Analysis Instruments
Filter
Showing 8281–8310 of 10669 results
| Brand | SOC/SurfaceOptics |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SOC720SW |
| Price | Upon Request |
| Spectral Range | 900–1700 nm |
| Spectral Resolution | 6.25 nm |
| Spectral Channels | 128 |
| Spectral Smile Distortion | <1.5 nm |
| Detector Type | High-Sensitivity InGaAs Linear Array (D* = 1.5 × 10¹³ cm·√Hz/W @ 1550 nm) |
| Spatial Resolution | 640 pixels (across-track) × 640 pixels (nominal along-track) |
| Frame Rate | 30 spatial lines/second |
| Data Cube Acquisition Time | 20 seconds/cube |
| Bit Depth | 14-bit |
| Optical f-number | f/2.4 |
| Total Field of View / Instantaneous Field of View (35 mm lens) | 10° / 0.015625° |
| Interface | Camera Link |
| Built-in Scanning Mechanism | Yes |
| Power Supply | AC / 12 V DC |
| Weight | 30 lbs (13.6 kg) |
| Dimensions | 7" × 14" × 22" (178 × 356 × 559 mm) |
| Data Format | Open BIL (Band Interleaved by Line), IEEE 754 floating-point compatible |
| Software Suite | HyperSpect™ (acquisition), HSAnalysis™ (radiometric calibration & spectral analysis), MIDIS™ (real-time multi-channel processing engine) |
| Brand | SOC/SurfaceOptics |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | SOC 720 |
| Operating Principle | Push-broom |
| Imaging Method | Interferometric |
| Deployment Mode | Ground-based |
| Spectral Range | 900–1700 nm |
| Spectral Resolution | 6.25 nm |
| Spatial Resolution (IFOV) | 0.79 mrad (configurable) |
| Field of View (TFOV) | 29° (configurable) |
| Spatial Sampling | 640 × 640 pixels |
| Frame Rate | 30 fps |
| Detector | InGaAs linear array, D* = 1.5 × 10¹³ cm·√Hz/W @ 1550 nm |
| Bit Depth | 14-bit |
| Data Format | Open BIL binary |
| Interface | Camera Link |
| Power Supply | AC / 12 V DC |
| Weight | 13.6 kg (30 lbs) |
| Dimensions | 178 × 356 × 559 mm (7″ × 14″ × 22″) |
| Brand | SOC/SurfaceOptics |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SOC740 |
| Pricing | Available Upon Request |
| Spectral Range | 1.0–2.35 µm |
| Detector | Cryogenically Cooled InSb (60 K) |
| Cut-off Filter | Integrated 2.35 µm Longpass Filter |
| Spatial Resolution | 640 × >2048 pixels (push-broom configuration) |
| Spectral Sampling Options | 100, 200, or 400 bands |
| Interchangeable Lenses | 28 mm, 50 mm, 200 mm (motorized lens rail for focus/FOV alignment) |
| Integration Time | Programmable |
| Optical Distortion Correction | Sub-pixel smile and keystone correction |
| Data Format | Open binary (BSQ/BIL-compatible) |
| Optional Processing Unit | SOC MIDIS™ Real-Time Onboard Processor |
| Software Compatibility | SOC Spectral Studio, ENVI, MATLAB, Python (GDAL, SciPy) |
| Brand | SOC/SurfaceOptics |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | SOC716FMV-SI |
| Price Range | USD 70,000–140,000 |
| Operating Principle | Filter-Based (Tunable Bandpass Filter Array) |
| Imaging Modality | 3D Spatio-Spectral Data Cube Acquisition |
| Deployment Mode | Ground-Based |
| Spectral Range | 270–1700 nm |
| Spectral Resolution | Configurable (Typical FWHM: 5–20 nm per band) |
| Spatial Resolution | 1280 × 1024 pixels |
| Total Field of View (TFOV) | Selectable (e.g., 11.0°–12.3° depending on lens module) |
| Instantaneous Field of View (IFOV) | Configurable via focal length and pixel pitch |
| Frame Rate | Up to 30 fps (full-frame) |
| Brand | SofTA |
|---|---|
| Model | M300s ELSD |
| Detector Type | Evaporative Light Scattering Detector (ELSD) |
| Light Source | Deuterium Lamp |
| Wavelength Range | 200 nm |
| Detection Mode | Dual-Beam |
| Nebulizer Material | PTFE (Teflon) |
| Drift Tube Temperature Range | Ambient to 120 °C |
| Nebulization Zone Temperature Range | 10–70 °C |
| Light Source Wavelength | 650 nm (Near-Infrared Laser, <5 mW, FCC Eye-Safe) |
| Detection Element | Sealed Large-Area Silicon Photodiode with Built-in High-Gain Amplifier |
| Sensitivity | 100 pg Glucopyranoside (Micro-HPLC, 2 µL direct injection, peak width at 10% height = 3 s) |
| Dynamic Range | 3 decades (normal/low gain), extendable to 4–4.5 decades |
| Mobile Phase Flow Rate | Up to 5 mL/min |
| Gas Requirement | N₂ or other inert gas at 50 psi |
| Gas Consumption | ≤2.5 L/min |
| Fluidic Path Materials | PTFE, Stainless Steel, Alumina, Borosilicate Glass |
| User Interface | Vacuum Fluorescent Display (VFD), 4 multifunction buttons |
| Signal Output | Fixed 10 mV / 5 V |
| Communication | RS-232 rear-panel interface |
| Power | 120/240 V, 50/60 Hz, 600 W |
| Dimensions | 25 W × 45 D × 29 H cm |
| Weight | 15 kg |
| Brand | SofTA |
|---|---|
| Model | M300s |
| Detector Type | Evaporative Light Scattering Detector (ELSD) |
| Wavelength Range | 195–600 nm |
| Detection Method | Dual-Beam |
| Light Source | Deuterium Lamp |
| Nebulizer Material | PTFE (Teflon®) |
| Drift Tube Temperature Range | Ambient to 120 °C |
| Nebulization Zone Temperature Range | 10–70 °C |
| Light Source for Scattering Detection | 650 nm Near-Infrared Laser (<5 mW, FCC Eye-Safe) |
| Minimum Detectable Mass | 100 pg (Glucopyranoside, Micro-HPLC, 2 µL direct injection) |
| Peak Width (10% height) | 3 s |
| Dynamic Range (Normal/Low Gain) | 3 decades |
| Extended Dynamic Range | 4–4.5 decades |
| Maximum Liquid Flow Rate | 5 mL/min |
| Gas Supply | N₂ or other inert gas, 50 psi |
| Gas Consumption | ≤2.5 L/min |
| Gas Pressure Regulation | Integrated pressure regulator and overpressure protection |
| Auto Shut-off Valve | Delayed closure after operation |
| Wetted Materials | PTFE, stainless steel, alumina, borosilicate glass |
| Signal Output | Fixed 10 mV or 5 V |
| Interface | RS-232 (rear panel) |
| Power | 120/240 V, 50/60 Hz, 600 W |
| Dimensions (W×D×H) | 25 × 45 × 29 cm |
| Weight | 15 kg |
| Brand | SofTA |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | M300s |
| Detection Principle | Evaporative Light Scattering |
| Compatible Systems | HPLC (Analytical & Preparative) |
| Wavelength Range | 195–600 nm |
| Optical Configuration | Dual-Beam |
| Light Source | Deuterium Lamp |
| Nebulizer Material | PTFE (Teflon®) |
| Drift Tube Temperature Range | Ambient to 120 °C |
| Nebulization Zone Temperature Range | 10–70 °C |
| Laser Source | 650 nm Near-Infrared, <5 mW (FCC Class I Eye-Safe) |
| Detector Element | Sealed, High-Gain Silicon Photodiode |
| Minimum Detectable Mass | 100 pg (Glucopyranoside, Micro-HPLC, 2 µL direct injection) |
| Peak Width (10% height) | 3 s |
| Dynamic Range (Normal/Low Gain) | 3 decades |
| Extended Dynamic Range | 4–4.5 decades |
| Mobile Phase Flow Rate Support | Up to 5 mL/min |
| Gas Requirement | N₂ or inert gas, 50 psi |
| Gas Consumption | ≤2.5 L/min |
| Fluidic Path Materials | PTFE, Stainless Steel, Alumina, Borosilicate Glass |
| User Interface | Vacuum Fluorescent Display (VFD), 4 Multifunction Keys |
| Onboard Method Storage | 10 Methods |
| Signal Output | Fixed (10 mV / 5 V) or Adjustable (0–5 V) |
| Communication | RS-232 (Rear Panel) |
| Power | 120/240 V, 50/60 Hz, 600 W |
| Dimensions (W×D×H) | 25 × 45 × 29 cm |
| Weight | 15 kg |
| Brand | SofTA |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | M300s |
| Compatible Instrument | HPLC Systems |
| Detector Type | Evaporative Light Scattering Detector (ELSD) |
| Wavelength Range | 200 nm (UV-Vis spectral cutoff, not tunable source) |
| Detection Mode | Dual-Beam |
| Light Source | Deuterium Lamp (for baseline stability reference), 650 nm Near-Infrared Laser (primary scattering source) |
| Nebulizer | PTFE (Teflon®) Capillary |
| Drift Tube Temperature Range | Ambient to 120 °C |
| Nebulization Zone Temperature Range | 10–70 °C |
| Sensitivity | 100 pg glucopyranoside (micro-HPLC, 2 µL direct injection, 3 s peak width at 10% height) |
| Dynamic Range | 3 decades (standard gain), up to 4.5 decades (extended range mode) |
| Mobile Phase Flow Rate | Up to 5 mL/min |
| Gas Requirement | N₂ or inert gas, 50 psi supply pressure |
| Gas Consumption | ≤2.5 L/min |
| Power | 120/240 V, 50/60 Hz, 600 W |
| Dimensions | 25 W × 45 D × 29 H cm |
| Weight | 15 kg |
| Brand | SofTA |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | M300S |
| Detection Principle | Evaporative Light Scattering |
| Compatible Systems | HPLC (Analytical & Preparative) |
| Wavelength Range | 195 nm (UV-Vis Deuterium Lamp for Optional UV Monitoring) |
| Detection Mode | Dual-Beam |
| Light Source | Deuterium Lamp |
| Nebulizer Material | PTFE (Teflon®) |
| Drift Tube Temperature Range | Ambient to 120 °C |
| Nebulization Zone Temperature Range | 10–70 °C |
| Laser Source | 650 nm Near-Infrared Diode (<5 mW, FCC Class I Eye-Safe) |
| Minimum Detectable Mass | 100 pg (Glucopyranoside, Micro-HPLC, 2 µL direct injection) |
| Peak Width (10% height) | 3 s |
| Dynamic Range (Normal/Low Gain) | 3 decades |
| Extended Dynamic Range | 4–4.5 decades |
| Mobile Phase Flow Rate | Up to 5 mL/min |
| Gas Requirement | Nitrogen or inert gas, 50 psi |
| Gas Consumption | ≤2.5 L/min |
| Liquid Path Materials | PTFE, Stainless Steel, Alumina, Borosilicate Glass |
| Interface | RS-232 |
| Power | 120/240 V, 50/60 Hz, 600 W |
| Dimensions (W×D×H) | 25 × 45 × 29 cm |
| Weight | 15 kg |
| Brand | SofTA |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | M300S |
| Detection Principle | Evaporative Light Scattering |
| Compatible Systems | HPLC (Analytical & Preparative) |
| Wavelength | 195 nm (Deuterium Lamp, Dual-Beam Configuration) |
| Nebulizer | PTFE-Coated Stainless Steel |
| Drift Tube Temperature Range | Ambient to 120 °C |
| Nebulization Zone Temperature Control | 10–70 °C |
| Light Source | Near-Infrared Laser (650 nm, <5 mW, FCC Class I Eye-Safe) |
| Detector | Sealed High-Gain Silicon Photodiode |
| Minimum Detectable Mass | 100 pg (Glucopyranoside, Micro-HPLC, 2 µL direct injection) |
| Peak Width (10% height) | 3 s |
| Dynamic Range (Standard Gain) | 3 decades |
| Extended Dynamic Range | 4–4.5 decades |
| Mobile Phase Flow Rate | Up to 5 mL/min |
| Gas Requirement | N₂ or inert gas, 50 psi |
| Gas Consumption | ≤2.5 L/min |
| Liquid Path Materials | PTFE, 316 Stainless Steel, Alumina, Borosilicate Glass (Optics) |
| User Interface | Vacuum Fluorescent Display (VFD), 4 Multifunction Keys |
| Onboard Method Storage | 10 Protocols |
| Signal Output | Fixed (10 mV / 5 V) or Adjustable (0–5 V) |
| Communication | RS-232 (Rear Panel) |
| Power | 120/240 V AC, 50/60 Hz, 600 W |
| Dimensions (W×D×H) | 25 × 45 × 29 cm |
| Weight | 15 kg |
| Brand | SofTA |
|---|---|
| Model | M300s |
| Detector Type | Evaporative Light Scattering Detector (ELSD) |
| Wavelength Range | 195 nm (Deuterium Lamp) |
| Detection Principle | Dual-Beam Light Scattering |
| Light Source | Deuterium Lamp |
| Drift Tube Temperature Range | Ambient to 120 °C |
| Nebulizer Zone Temperature Range | 10–70 °C |
| Nebulizer Material | PTFE (Teflon®) |
| Minimum Detectable Mass | 100 pg (Glucopyranoside, Micro-HPLC) |
| Peak Width (10% height) | 3 s (2 µL direct injection) |
| Dynamic Range | 3 orders of magnitude (normal/low gain) |
| Mobile Phase Flow Rate | Up to 5 mL/min |
| Gas Requirement | N₂ or inert gas at 50 psi |
| Gas Consumption | ≤2.5 L/min |
| Interface | RS-232 |
| Power | 120/240 V, 50/60 Hz, 600 W |
| Dimensions (W×D×H) | 25 × 45 × 29 cm |
| Weight | 15 kg |
| Brand | SofTA |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | Model 100 |
| Detection Principle | Evaporative Light Scattering Detection (ELSD) |
| Compatible System | HPLC / UHPLC |
| Light Source | 670 nm Laser (<5 mW) |
| Nebulizer Gas | N₂ or inert gas (50 psi, ~2.5 SLPM) |
| Operating Temperature | 55 °C (evaporator), ambient to 85 °C (environment) |
| Flow Rate Range | 0–5 mL/min |
| Detector Response | Mass-sensitive, gradient-compatible |
| Detection Limit | 10 ng (on-column, typical) |
| Dynamic Range | >4 orders of magnitude |
| Precision | <2% RSD |
| Output Signal | 0–5 VDC analog |
| Interface | RS-232 |
| Power Requirement | 120/240 VAC, 50/60 Hz, 600 W |
| Dimensions | 9.8" W × 18" D × 11.5" H |
| Weight | 23 lbs |
| Construction Materials | Stainless steel fluid path, Teflon™ tubing, fused silica optical windows |
| Environmental Rating | Indoor use only |
| Brand | SofTA |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | 300s ELSD |
| Detection Principle | Evaporative Light Scattering Detection (ELSD) |
| Wavelength Range | 200 nm (UV cutoff, not emission wavelength) |
| Optical Configuration | Dual-beam |
| Light Source | Deuterium Lamp (for baseline stability reference), NIR Laser (650 nm, <5 mW) as primary scattering source |
| Nebulizer Material | PTFE (Teflon®) |
| Drift Tube Temperature Range | Ambient to 120 °C |
| Nebulization Zone Temperature Range | 10–70 °C |
| Sensitivity | 100 pg glucopyranoside (micro-HPLC, 2 µL direct injection, peak width at 10% height = 3 s) |
| Dynamic Range | 3 orders of magnitude (standard gain), extendable to 4–4.5 orders with gain optimization |
| Flow Rate Compatibility | Up to 5 mL/min (HPLC & preparative LC) |
| Gas Requirement | N₂ or inert gas, 50 psi supply, ≤2.5 L/min consumption |
| Integrated Pressure Regulation | Yes, with automatic shutoff delay and overpressure protection |
| Signal Output | Fixed 10 mV or 5 V |
| Interface | RS-232 (rear panel), digital status I/O (zero control, valve control, error reporting) |
| Power | 120/240 V AC, 50/60 Hz, 600 W |
| Dimensions | 25 W × 45 D × 29 H cm |
| Weight | 15 kg |
| Brand | SofTA |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | Model 300s |
| Detection Principle | Evaporative Light Scattering Detection (ELSD) |
| Wavelength Range | 195–600 nm |
| Optical Configuration | Dual-Beam |
| Light Source | Deuterium Lamp |
| Nebulizer Material | PTFE (Teflon®) |
| Drift Tube Temperature Range | Ambient to 120 °C |
| Nebulization Zone Temperature Range | 10–70 °C |
| Laser Source | 650 nm Near-Infrared Diode (<5 mW, FCC Class I Eye-Safe) |
| Detector | Sealed Large-Area Silicon Photodiode with Integrated High-Gain Amplifier |
| Minimum Detectable Mass | 100 pg Glucopyranoside (Micro-HPLC, 2 µL direct injection, peak width at 10% height: 3 s) |
| Dynamic Range | 3 decades (standard gain), up to 4.5 decades with extended range mode |
| Mobile Phase Flow Rate Compatibility | Up to 5 mL/min |
| Gas Supply | N₂ or other inert gas, 50 psi inlet pressure |
| Gas Consumption | ≤2.5 L/min |
| Liquid Path Materials | PTFE, Stainless Steel, Alumina, Borosilicate Glass (optical lens) |
| User Interface | Vacuum Fluorescent Display (VFD), 4 multifunction buttons |
| Data Output | Fixed 10 mV / 5 V analog |
| Power | 120/240 V AC, 50/60 Hz, 600 W |
| Dimensions (W×D×H) | 25 × 45 × 29 cm |
| Weight | 15 kg |
| Brand | SofTA |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Evaporative Light Scattering Detector (ELSD) |
| Compatible System | HPLC (Analytical & Preparative) |
| Wavelength Range | 195–600 nm |
| Detection Mode | Dual-Beam |
| Light Source | Deuterium Lamp |
| Nebulizer Material | PTFE |
| Drift Tube Temperature Range | Ambient to 120 °C |
| Nebulization Zone Temperature Range | 10–70 °C |
| Laser Source | 650 nm Near-Infrared Diode (<5 mW, FCC Class I Eye-Safe) |
| Detector Element | Sealed Large-Area Silicon Photodiode with Integrated High-Gain Amplifier |
| Minimum Detectable Mass | 100 pg Glucopyranoside (Micro-HPLC, 2 µL Direct Injection, 3 s Peak Width at 10% Height) |
| Dynamic Range | 3 orders of magnitude (Normal/Low Gain), Extended to 4–4.5 orders with gain optimization |
| Mobile Phase Flow Rate | Up to 5 mL/min |
| Gas Supply | Nitrogen or inert gas, 50 psi inlet pressure |
| Gas Consumption | ≤2.5 L/min |
| Fluidic Path Materials | PTFE, Stainless Steel, Alumina, Optical Glass |
| User Interface | Vacuum Fluorescent Display (VFD) with 4 Multifunction Keys |
| Onboard Method Storage | 10 Methods |
| Signal Output | Fixed 10 mV or 5 V |
| Digital Interface | RS-232 (Rear Panel) |
| Power | 120/240 V AC, 50/60 Hz, 600 W |
| Dimensions | 25 W × 45 D × 29 H cm |
| Weight | 15 kg |
| Brand | SofTA |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | 300s |
| Detection Principle | Evaporative Light Scattering (ELSD) |
| Wavelength | 650 nm (Near-Infrared Laser) |
| Beam Configuration | Dual-Beam |
| Light Source | 650 nm NIR Laser (<5 mW, FCC Eye-Safe Compliant) |
| Nebulizer | PTFE-Coated Stainless Steel Capillary |
| Drift Tube Temperature Range | Ambient to 120 °C |
| Nebulization Zone Temperature Range | 10–70 °C |
| Sensitivity | 100 pg Glucopyranoside (Micro-HPLC, 2 µL direct injection, peak width at 10% height = 3 s) |
| Dynamic Range | 3 decades (normal/low gain), extendable to 4–4.5 decades with signal processing |
| Flow Rate Compatibility | Up to 5 mL/min (HPLC & preparative LC) |
| Gas Requirement | N₂ or other inert gas, 50 psi inlet pressure |
| Gas Consumption | ≤2.5 L/min |
| Integrated Pressure Regulation | Yes, with automatic shutoff delay and overpressure protection |
| Fluidic Path Materials | PTFE, 316 stainless steel, alumina, borosilicate glass (optical lens) |
| User Interface | Vacuum Fluorescent Display (VFD), 4 multifunction buttons |
| Onboard Method Storage | 10 user-defined methods |
| Signal Output | Fixed 10 mV or 5 V |
| Digital Interface | RS-232 (rear panel) |
| Power | 120/240 V AC, 50/60 Hz, 600 W |
| Dimensions (W×D×H) | 25 × 45 × 29 cm |
| Weight | 15 kg |
| Brand | SofTA |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | Model 300S |
| Detection Principle | Evaporative Light Scattering |
| Compatible Systems | HPLC (Analytical & Preparative) |
| Wavelength Range | 195–600 nm |
| Optical Configuration | Dual-Beam |
| Light Source | Deuterium Lamp |
| Nebulizer Material | PTFE (Teflon®) |
| Drift Tube Temperature Range | Ambient to 120 °C |
| Nebulization Zone Temperature Range | 10–70 °C |
| Light Source for Detection | 650 nm Near-Infrared Laser (<5 mW, FCC Class I Eye-Safe) |
| Detector Element | Sealed, Large-Area Silicon Photodiode with Integrated High-Gain Amplifier |
| Minimum Detectable Mass | 100 pg Glucopyranoside (Micro-HPLC, 2 µL direct injection, peak width at 10% height: 3 s) |
| Dynamic Range (Normal Gain) | 3 decades |
| Dynamic Range (Extended Mode) | 4–4.5 decades |
| Mobile Phase Flow Rate Compatibility | Up to 5 mL/min |
| Carrier Gas | Nitrogen or other inert gas |
| Gas Pressure Requirement | 50 psi |
| Gas Consumption | ≤2.5 L/min |
| Integrated Gas Pressure Regulation | Yes (Built-in Regulator & Overpressure Protection) |
| Auto Shut-off Valve | Yes (Timed Delay Cutoff) |
| Fluidic Path Materials | PTFE, Stainless Steel, Alumina, Borosilicate Glass (Optical Lens) |
| User Interface | Vacuum Fluorescent Display (VFD) + 4 Multifunction Keys |
| Onboard Method Storage | 10 Methods |
| Signal Output Options | Fixed 10 mV / 5 V |
| Communication Interface | RS-232 (Rear Panel) |
| Power Supply | 120/240 V AC, 50/60 Hz, 600 W |
| Dimensions (W×D×H) | 25 × 45 × 29 cm |
| Weight | 15 kg |
| Brand | SofTA |
|---|---|
| Origin | USA |
| Model | UM3000 |
| Detection Principle | Evaporative Light Scattering |
| Light Source | 650 nm Laser Diode |
| Detector | Photomultiplier Tube (PMT) |
| Evaporation Zone Temp Range | Ambient to 130 °C |
| Nebulizer Tube Temp Range | Ambient to 80 °C |
| Temp Control Increment | 1 °C |
| Temp Accuracy | ±1 °C |
| Mobile Phase Flow Rate | 10 µL/min to 3 mL/min |
| Carrier Gas | Nitrogen or Compressed Air |
| Gas Input Pressure | 2–5 bar |
| Gas Pressure Measurement Accuracy | 0.01 bar |
| Gas Consumption | 1–4 L/min |
| Detection Limit | <1 ng (glucose, direct injection) |
| Typical Quantitation Range | 0.2–10 µg (glucose, HPLC) |
| Noise Level | <0.1 mV (at 1 mL/min) |
| Signal Output | 0–10 mV DC or 0–1 V DC |
| Interface | RS232 |
| Detection Angle | 120° |
| Display | LCD |
| Operating Environment | 15–35 °C, RH <90% |
| Power Supply | 220 VAC, 50 Hz |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | FJA-10 |
| Portability | Handheld / Field-Deployable |
| Calibration Compatibility | KCl/NaCl standard solutions (0.01–0.2 mol/L) |
| Electrode Material | Graphite |
| Temperature Compensation | Integrated NTC thermistor |
| Response Time | <20 s |
| Minimum Volumetric Water Content for Reliable Measurement | ~20% (varies with clay content) |
| Electrode Constant | Adjustable (factory-set to 100 cm⁻¹ for direct mS/cm readout) |
| Linearity (0.02–0.3 N) | R² ≥ 0.98 |
| Repeatability | Relative average deviation ≤5% (max. 10%) |
| Brand | PV Measurements |
|---|---|
| Model | IV16 |
| Light Source Class | ABA-Class Solar Simulator (Standard) |
| Illuminated Area | 16 cm × 16 cm |
| Voltage Range | ±2.0 V |
| Current Range | 0–10 A |
| Spectral Match Compliance | ASTM E927-23, IEC 60904-9 Ed. 3 |
| Temporal Stability | < ±1% (A-class), < ±3% (B-class), < ±10% (C-class) |
| Irradiance Uniformity | < ±2% (A-class), < ±3% (B-class), < ±10% (C-class) |
| Standard Test Conditions (STC) | 1000 W/m², AM1.5G spectrum, 25 °C ± 2 °C |
| Software | IV Analysis Suite with GLP-compliant data logging, report generation (PDF/text), and audit-trail-enabled parameter calculation (Voc, Isc, Jsc, Pmax, Vmax, Imax, FF, η) |
| Sample Interface | 4-wire Kelvin connection |
| Optional Upgrades | AAA-class simulator, temperature-controlled vacuum chuck, Rs extraction via attenuated-light sweep, automated database export, reverse-bias leakage testing, conveyor integration |
| Brand | Solar Light |
|---|---|
| Origin | USA |
| Model | 16S Series (150W–300W UV) |
| Spectral Range | 290–400 nm (UV-A/UV-B selectable) |
| Beam Uniformity (center) | >90% |
| Compliance | ASTM G154, ASTM G155, IEC 61215, ISO 4892-3 |
| Output Orientation | Vertical-down / Vertical-up / Horizontal |
| Optional Spectral Configurations | UVA-only, UVB-only, UVA+UVB, AM0 (250–2500 nm), AM1.5G (250–2500 nm), Visible-only |
| Optional Accessories | Motorized shutter with remote control, calibrated neutral density attenuation screens, spectral verification report, custom collimation optics |
| Brand | Solar Light |
|---|---|
| Origin | USA |
| Model | 8-5103 |
| Surface Roughness (Ra) | 5 µm (ISO-compliant) |
| Package Quantity | 200 pcs/box |
| Material | Polymethyl Methacrylate (PMMA) |
| Form | Flat Optical Diffuser Plate |
| Brand | Solar Light |
|---|---|
| Origin | USA |
| Model | 8-5105 |
| Dimensions | 50.3 mm × 50.3 mm |
| Surface Roughness (Ra) | 5 µm |
| Surface Roughness (Sa) | 6 µm |
| Compliance | ISO 25178-2 |
| Packaging | 200 pcs per box |
| Category | Spectroscopy Accessory / Optical Diffuser Plate |
| Brand | Solar Light |
|---|---|
| Origin | USA |
| Model | LS1000 1000W UV |
| Spectral Range | 290–400 nm |
| Output Configurations | Circular or Square Beam (2", 4", 6" / 5 cm, 10 cm, 15 cm) |
| Uniformity | ≥98% over usable area |
| Collimated Working Distance | 35.5 cm |
| Compliance | ASTM G154, ASTM G155, IEC 61215, ISO 4892-3, CE |
| Light Source | 1000W Xenon Arc Lamp |
| Power Supply | High-Efficiency Switching PSU with Adjustable Lamp Power |
| Optional Filters | UVA-only, UVB-only, Visible-only, Neutral Density Attenuation Screens |
| Beam Orientation | Vertical Downward, Vertical Upward, or Horizontal |
| Long-Term Stability | <±1% drift per 100 hours |
| Brand | Solar Light |
|---|---|
| Origin | USA |
| Model | SPF-290AS |
| Wavelength Range | 290–400 nm |
| Scan Resolution Options | 1 nm, 2 nm, or 5 nm |
| Compliance | ISO 23698:2024, ISO 23675:2024, ISO 24443, FDA Guidance, COLIPA, Boots Star Rating Methodology |
| Sample Types | Lotions, creams, sprays, gels, powders, emulsions, textiles |
| Data Output | Monochromatic Protection Factor (MPF), SPF, UV transmittance spectra |
| Software Features | Pre-loaded erythemal action spectrum & solar irradiance reference data (CIE 1987 / ISO 17166), user-modifiable weighting functions, audit-trail-enabled calculation logs |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SolarSIM-D2 |
| Pricing | Upon Request |
| Brand | Solartron Analytical |
|---|---|
| Origin | United Kingdom |
| Model | 1260A |
| Channel Count | Single-Channel Workstation |
| Current Range | 200 nA – 2 A |
| Current Accuracy | ±0.2% of reading + ±1% of full scale |
| Potential Accuracy | ±0.2% of reading + ±10 mV |
| Potentiostatic Range | ±14.5 V (when coupled with 1287) / ±40.95 V (1260A standalone) |
| AC Impedance Frequency Range | 10 µHz – 32 MHz |
| Voltage/Current Resolution | 1 µV / 1 pA |
| Frequency Resolution | 0.015 ppm |
| Phase Accuracy | ±0.1° |
| Magnitude Accuracy | ±0.1 dB |
| Electrode Configurations | 2-, 3-, and 4-terminal |
| Active Shielding | Yes |
| Floating Measurement Capability | Yes |
| Software | CorrWare & ZPlot v3.x |
| Brand | Solartron Analytical |
|---|---|
| Origin | United Kingdom |
| Model | 1260A |
| Instrument Type | Multi-Channel Electrochemical Workstation |
| Current Range | ±60 mA |
| Current Accuracy | ±0.2% of reading |
| Potential Accuracy | ±0.2% of reading |
| Potentiostatic Range | ±40.95 V |
| AC Impedance Frequency Range | 10 µHz – 32 MHz |
| Phase Accuracy | ±0.1° |
| Magnitude Accuracy | ±0.1% |
| Frequency Resolution | 0.015 ppm |
| Core Technology | Single-Sine Correlation Method |
| Brand | Solartron Analytical |
|---|---|
| Origin | United Kingdom |
| Model | 1287/1260 |
| Channel Count | Single-Channel |
| Current Range | ±2 A |
| Current Accuracy | ±0.2% of reading |
| Potential Accuracy | ±0.2% of reading |
| Potentiostatic Range | ±14.5 V |
| EIS Frequency Range | 10 µHz – 32 MHz |
| Voltage Resolution | 1 µV |
| Current Resolution | 1 pA |
| Polarization Voltage (1260A) | ±40.95 V |
| Frequency Resolution | 15 ppm (0.000015) |
| Phase Accuracy | ±0.1° |
| Magnitude Accuracy | ±0.1 dB |
| Measurement Configurations | 2-, 3-, and 4-terminal |