| Brand | NCS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop |
| Excitation Method | Spark Discharge |
| Detector Type | CMOS Array |
| Focal Length | 500 mm |
| Grating Groove Density | 2700 lines/mm |
| Wavelength Range | 130–800 nm |
| Power Supply | 220 V ±10%, Single-Phase, 10 A, 2.5 kVA |
| Weight | 100 kg |
| Argon Consumption (Standby) | 60 mL/min |
| Optical System | Paschen-Runge Mount with Holographic Grating |
| Temperature Control Precision | ±0.1 °C |
| Startup Time (Cold) | 30 min |
| Startup Time (Hot) | 5 min |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | NeoSpectra Micro |
| Price | USD 1,400 (FOB) |
| Wavelength Range | 1250–2500 nm |
| Optical Resolution (FWHM @ 1550 nm) | 8 nm or 16 nm |
| SNR (2-s scan, 16-nm res.) | 1000:1 @ 2050 nm |
| Operating Temperature | −5 to +40 °C |
| Wavelength Accuracy | ±1.5 nm @ 1400 nm (<40 °C) |
| Wavelength Repeatability | ±0.1 nm @ 1400 nm, 0.5 A.U., 16-nm res. |
| PSD Sensitivity Threshold | > max PSD/10 |
| Configuration | Reflectance (Rx) or Transmission (Tx) compatible |
| Brand | AMS |
|---|---|
| Origin | Beijing, China |
| Model | NexaFlo™ |
| Configuration | Up to 14 independent analytical channels |
| Detection Principles | Continuous Flow Analysis (CFA) with segmented flow, online pre-treatment (dialysis, UV digestion, distillation, heating, dilution, mixing, extraction) |
| Detector Options | UV-Vis spectrophotometer, flame photometer (for K⁺/Na⁺), fluorimeter |
| Display | 7-inch color touchscreen (NexaFlo™ 450 variant) |
| Automation | Fully programmable CFA software with auto-startup/shutdown, QC control, auto-dilution, LIMS export, and audit-trail-capable operation |
| Compliance | Designed to support ASTM D129, ISO 11905-1, USP <621>, EPA Methods 353.2, 354.1, 365.2, and GLP/GMP-aligned data integrity practices |
| Sample Handling | Dual-probe autosampler optional |
| Fluidics | High-precision three-speed peristaltic pumps |
| Reagent Management | Integrated sealed reagent reservoirs with vapor/leak mitigation |
| Brand | GKInst |
|---|---|
| Model | NFC |
| Type | Flow-through X-ray Transmission Cell |
| Window Material | Silicon Nitride (Si₃N₄) |
| Window Size | 1.5 mm × 1.5 mm |
| Window Thickness | 200 nm |
| Cell Volume | 5 mL |
| Cell Body Thickness | 1 mm |
| Fluidic Interface | M6 threaded port |
| Noise Suppression | Optimized laminar-flow pump coupling and acoustic decoupling mount |
| Brand | NOY |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop |
| Detection Method | Vacuum Mode |
| Minimum Detectable Leak Rate | 3×10⁻¹³ Pa·m³/s |
| Startup Time | ≤90 s |
| Response Time | ≤0.5 s |
| Maximum Pressure at Test Port | ≤2000 Pa |
| Brand | Nippon Instruments Corporation (NIC) |
|---|---|
| Origin | Japan |
| Model | WA-5A |
| Instrument Type | Benchtop Laboratory Analyzer |
| Measurement Principle | Cold Vapor Atomic Absorption Spectrometry (CVAAS) with Dual Gold Amalgamation |
| Detection Limit | 0.001 ng (1 pg) |
| Linear Range | 0.001 – 1000 ng |
| Compliance | ASTM D5954-98(2014)e1, ISO 6978-2:2005, ISO 20552, JIS K 0312, HJ 910–2017, GB 16781.2–2010, HJ 597–2011, HJ 543–2009 |
| Sample Forms | Gaseous matrices (ambient air, natural gas, shale gas, LPG, LNG, hydrogen), aqueous samples (with S-MA/AQUA accessory) |
| Brand | Nisene |
|---|---|
| Origin | USA |
| Model | JetEtch Pro |
| Certifications | CE, SEMI S2-93, SEMI S2-2000 |
| Power | 350 W @ 95–130 VAC or 210–250 VAC |
| Dimensions (H×W×D) | 290 × 290 × 419 mm (11.5″ × 11.5″ × 16.5″) |
| Weight | 17 kg (38 lb) |
| Compressed Air | 4.2 kg/cm² (60–100 psi) |
| Nitrogen Supply | 2.8 L/min (0.1 ft³/min) |
| Etchant Flow Rates | Pulse mode: 1, 2, 5, or 1–10 mL/min |
| Vortex mode | 1–6 mL/min |
| Temperature Range | HNO₃: 20–90 °C |
| H₂SO₄ | 20–250 °C |
| Mixed acids | 20–100 °C |
| Etch Time | 1–1800 s (1 s increments) |
| Heating Ramp Time | 0–120 s (1 s increments) |
| Acid Reservoirs | Four 500 mL or 1 L bottles (33/38/40/45 mm cap diameter) |
| Programmable Methods | 100 user-defined protocols |
| Etchant Options | Fuming nitric acid, fuming sulfuric acid, concentrated sulfuric acid, nitric–sulfuric mixtures (ratios: 6:1, 5:1, 4:1, 3:1 in either direction) |
| Rinse Options | Cold H₂SO₄, cold HNO₃, or no rinse |
| Etch Modes | Vortex spray, pulsed spray, and dual-mode sequencing |
| Patented Processes | CuProtect™ (US Patent 8,945,343 B2), TotalProtect™ (US Patent 9,543,173 B2), PlasmaEtch™ (US Patent 9,548,227 B2) |
| Brand | Niton |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Model | XL5 |
| Application | Field-Portable |
| Industry-Specific Use | Geological & Mining Exploration |
| Elemental Range | Mg to U |
| Quantification Range | 1 ppm – 99.99% |
| Repeatability | ±0.1% RSD |
| Detector | Graphene-Enhanced Silicon Drift Detector (SDD) |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Model | PQ001-Fiber Suspension Dispersion |
| Instrument Type | Low-Field Nuclear Magnetic Resonance (LF-NMR) Analyzer |
| Sample Type | Solid–Liquid Hybrid Systems |
| Magnet Type | Permanent Magnet |
| Magnetic Field Strength | 0.5 T ± 0.03 T |
| Sample Tube Dimensions | Ø24.2 mm × H25 mm |
| Measurement Time | ≤120 s per test |
| Software Architecture | Integrated GUI with Real-Time T₂ Relaxometry |
| Compliance Framework | Designed for GLP-compliant environments |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | VTMR |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Compatibility | Solid-Liquid Dual-Phase |
| Magnet Type | Permanent Magnet |
| Static Field Strength | 0.5 ± 0.05 T |
| Standard Temperature Range | Ambient to 130 °C |
| Optional Cryo/High-Temp Module | –100 °C to 200 °C |
| Imaging Capability | Optional |
| Core Technology | FLAT (Fast Low-Amplitude Transient) Acquisition for Short-T₂/Weak-Signal Detection |
| Primary Measurement Modes | T₁ & T₂ Relaxometry, Diffusion-Weighted Analysis, MR Imaging (optional) |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Model | VTMR20-010V-2 |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Type | Solid-Liquid Hybrid |
| Magnet Type | Permanent Magnet |
| Static Magnetic Field Strength | 0.5 ± 0.05 T |
| Temperature Control Range (Standard) | 25–130 °C |
| Optional Cryo/High-Temp Module | –100 to 200 °C |
| Pulse Sequence | Modified Spin-Echo CPMG (MSE-CPMG) |
| Measurement Time | ≤2 min per sample |
| Detection Nucleus | ¹H |
| Applications | Crosslinking density, T₂ relaxation distribution, phase-separated water dynamics, polymer segment mobility quantification |
| Brand | NIUMAG |
|---|---|
| Origin | Canada |
| Model | NMReady-100 |
| Operating Frequency | 100 MHz (2.35 T) |
| Sample Type | Liquid |
| Magnet Type | Permanent Magnet (Cryogen-Free) |
| Nuclei Support | ¹H only or dual-nucleus (¹H/¹³C, ¹H/³¹P, ¹H/¹⁹F) |
| User Interface | Integrated LCD touchscreen with cross-platform OS compatibility (Windows/macOS/Linux) and remote access capability |
| Power Mode | Energy-saving standby mode available |
| Dimensions & Installation | Compact benchtop footprint |
| Origin | Finland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | N25E-SWIR |
| Price | Upon Request |
| Spectral Range | 1000–2500 nm |
| Spectral Resolution | 10 nm |
| Spectral Sampling Interval | 6.3 nm |
| Effective Slit Length | 9.6 mm |
| Optical Throughput Efficiency | >50% |
| Relative Aperture | f/2.0 |
| Slit Width | 30 µm |
| Stray Light Level | 0.5% |
| Detector Type | Mercury Cadmium Telluride (MCT) |
| Detector Cooling | Thermoelectric (TE) |
| Full-Frame Pixel Count | 320 × 256 (240 active rows) |
| Pixel Size | 30 × 30 µm |
| A/D Output | 14-bit |
| Dynamic Range | 800:1 |
| Frame Rate (Full Frame) | 100 fps |
| Exposure Time Range | 0.1–20 ms |
| Computer Interface | LVDS |
| Lens Mount | C-Mount |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Nordson Dage Quadra™ 5 |
| Price Range | USD $130,000–$195,000 (est.) |
| Instrument Type | Scanning X-ray System |
| X-ray Tube Power | ≤10 W (0.35 µm spot size), ≤20 W (0.95 µm spot size) |
| X-ray Source | QuadraNT™ Sealed Transmission Tube |
| Detector | AspireFP™ Flat-Panel Detector |
| Integrated Micro-CT Stage | Yes |
| Thermal Stage for Reflow Simulation | Yes |
| Compliance Standards | IPC-A-610, IPC-7095, ISO/IEC 17025 (for lab accreditation), FDA 21 CFR Part 11 (software audit trail enabled) |
| Brand | NorECs |
|---|---|
| Origin | Norway |
| Model | ProboStat |
| Instrument Type | Electrochemical Sample Holder |
| Operating Temperature (Long-term) | Up to 1400 °C |
| Operating Temperature (Short-term) | Up to 1600 °C |
| Sample Geometry | Disc-shaped (Ø 10–24 mm, thickness 25–50 mm) or Rod-shaped (Ø up to 24 mm, length 30–1500 mm) |
| Electrode Configurations | 2-, 3-, or 4-electrode setups |
| Gas Environment | Oxidizing, inert, reducing, corrosive, humid/dry |
| pressure range | 10⁻² mbar to 1 bar (up to 25 bar in sealed steel tube) |
| Dual-chamber capability | Yes |
| Van der Pauw measurement | Supported (4-point) |
| Seebeck coefficient measurement | Supported (rod geometry) |
| Electrical measurements | DC conductivity, impedance spectroscopy, polarization, dielectric breakdown (HV version), concentration cell, transference number, permeability, fuel cell testing |
| Brand | North Point |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automated |
| Oven Temperature Range | Ambient to 200 °C (1 °C increment) |
| Valve & Transfer Line Temperature Range | Ambient to 200 °C (1 °C increment) |
| Sample Loop Volume | 1 mL |
| Temperature Control Accuracy | ±0.1 °C |
| Sample Tray Capacity | 12 / 24 / 30 positions |
| Vial Sizes Supported | 10 mL and 20 mL standard (custom sizes available) |
| Brand | Novocontrol Technologies |
|---|---|
| Origin | Germany |
| Model | NEISYS |
| Frequency Range | 3 µHz – 100 MHz |
| Sampling Rate | 10⁷ points/sec |
| Impedance Range | 10⁻⁴ Ω – 1 TΩ |
| Loss Factor Accuracy | ±1×10⁻⁴ |
| Architecture | Four-Electrode, Separated Current/Voltage Signal Paths |
| Thermal Expansion Option | Yes |
| Operating Modes | Frequency-Domain (EIS, Dielectric, Conductivity, Loss Tangent) & Time-Domain (CV, LSV, SWV, CA, CP, Galvanostatic/Potentiostatic Cycling, Battery Charge/Discharge, Capacitor Charging/Discharging) |
| Compliance Support | ASTM D257, ISO 60270, IEC 60601-2-60 (for dielectric safety), GLP/GMP-ready data audit trail |
| Brand | NOY |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop |
| Detection Method | Vacuum Mode |
| Minimum Detectable Leak Rate | 3×10⁻¹³ Pa·m³/s |
| Pump-down & Startup Time | ≤90 s |
| Response Time | ≤0.5 s |
| Maximum Inlet Pressure at Test Port | ≤2000 Pa |
| Brand | NOY |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop |
| Detection Method | Vacuum Mode (also supports Sniffer Mode) |
| Minimum Detectable Leak Rate | 3×10⁻¹³ Pa·m³/s |
| Startup Time | ≤100 s |
| Response Time | ≤0.5 s |
| Maximum Inlet Pressure (for Vacuum Mode) | ≤2000 Pa |
| Leak Rate Display Range | 1×10⁻² to 1×10⁻¹³ Pa·m³/s (Vacuum Mode) |
| Dimensions | 420 × 275 × 359 mm |
| Weight | 26 kg |
| Ion Source | Dual Iridium Filament |
| Mass Analyzer | 180° Non-Uniform Magnetic Sector (U-Shaped Magnet) |
| Brand | NOY |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Benchtop |
| Detection Method | Vacuum Mode |
| Minimum Detectable Leak Rate | 3×10⁻¹³ Pa·m³/s |
| Warm-up Time | ≤90 s |
| Response Time | ≤0.5 s |
| Maximum Inlet Pressure | ≤2000 Pa |
| Leak Rate Display Range | 1×10⁻² to 1×10⁻⁹ Pa·m³/s (zero-referenced) |
| Brand | NOY |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | NHJ600 |
| Instrument Type | Portable |
| Detection Method | Vacuum Mode |
| Minimum Detectable Leak Rate | 3×10⁻¹³ Pa·m³/s |
| Startup Time | ≤90 s |
| Response Time | ≤0.5 s |
| Maximum Pressure at Test Port | ≤2000 Pa |
| Leak Rate Display Range | 1×10⁻² to 1×10⁻¹³ Pa·m³/s |
| Brand | NOY |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | NHJ800D |
| Instrument Type | Portable |
| Detection Method | Vacuum Mode |
| Minimum Detectable Leak Rate | 3×10⁻¹³ Pa·m³/s |
| Startup Time | ≤90 s |
| Response Time | ≤0.5 s |
| Maximum Inlet Pressure | ≤2000 Pa |
| Leak Rate Display Range | 1×10⁻² to 1×10⁻¹³ Pa·m³/s |
| Brand | NOY |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop |
| Detection Method | Vacuum Mode |
| Minimum Detectable Leak Rate | 5×10⁻¹³ Pa·m³/s |
| Startup Time | ≤90 s |
| Response Time | ≤0.5 s |
| Maximum Pressure at Test Port | ≤2000 Pa |
| Leak Rate Display Range | 1×10⁻² to 1×10⁻⁹ Pa·m³/s |
| Brand | NOY |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop |
| Detection Method | Vacuum Mode |
| Minimum Detectable Leak Rate | 3×10⁻¹³ Pa·m³/s |
| Warm-up Time | ≤90 s |
| Response Time | ≤0.5 s |
| Maximum Inlet Pressure | ≤2000 Pa |
| Ion Source | Dual Iridium Filament |
| Brand | NU |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Astrum ES |
| Pricing | Available Upon Request |
| Brand | Nu Instruments |
|---|---|
| Origin | United Kingdom |
| Model | Nu AttoM ES |
| Type | Double-Focusing Magnetic Sector ICP-MS |
| Detector System | Wide Dynamic Range Faraday + Secondary Electron Multiplier (SEM) |
| Resolution Mode | Adjustable High-Resolution Slit (Fixed Width, Vertically Movable) |
| Primary Application | Isotope Ratio Analysis & Ultra-Trace Elemental Quantification in Geochemical and Environmental Matrices |
| Brand | NU |
|---|---|
| Origin | United Kingdom |
| Model | Perspective |
| Instrument Type | Stable Gas Isotope Ratio Mass Spectrometer |
| Mass Dispersion | Up to 600 mm |
| Mass Resolution (m/Δm) | >200 for CNOS and H |
| Collector Configuration | Up to 12 fixed, high-precision Faraday and/or multi-collector arrays |
| Ion Source | High-efficiency electron impact ion source |
| Optics | Patented zoom optics system |
| Compatible Interfaces | NU Dual Inlet, NU GasBench, NU Carbonate Device |
| Brand | NU |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Vitesse |
| Pricing | Available Upon Request |
| Brand | OBLF |
|---|---|
| Origin | Germany |
| Model | OBLF GS1000 II |
| Instrument Type | Floor-standing |
| Excitation Method | Spark |
| Detector Type | Photomultiplier Tube (PMT) |
| Focal Length | 500 mm |
| Grating Groove Density | 2700 lines/mm |
| Wavelength Range | 120–780 nm |
| Number of Channels | 32 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Blue Series |
| Spectral Range | 200–1100 nm |
| Detector | CCD (2048-pixel linear array) |
| Optical Resolution (FWHM) | 0.13–6.0 nm (dependent on grating and slit configuration) |
| Sensitivity | 100 photons/count at 400 nm |
| Signal-to-Noise Ratio | 1000:1 (full well, 1 s integration) |
| Dynamic Range | 2000:1 (6 decades) |
| Stray Light | <0.1% at 435 nm |
| Interface | USB 2.0, SMA905 fiber input, 16-bit ADC |
| Integration Time | 1 ms – 65 s |
| Grating Options | 300–2400 g/mm (holographic & ruled) |
| Slit Options | 14–200 µm |
| Focal Ratio | f/4 |
| Optical Design | Symmetric Czerny–Turner with crossed-beam geometry |
| Power Supply | <100 mA via USB port |
| Dimensions | 25.4 × 76.2 × 127 mm (1 × 3 × 5 in) |
| Weight | 397 g (14 oz) |