China Iron and Steel Research Institute Group NCS Testing Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNCS
OriginJiangsu, China
Manufacturer TypeManufacturer
Instrument TypeOxygen and Nitrogen Analyzer
ModelON3500
Oxygen Range (Low)0.1 ppm–0.5%
Oxygen Range (High)0.5%–20%
Nitrogen Range (Low)0.1 ppm–0.5%
Nitrogen Range (High)0.5%–50%
Oxygen Precision1 ppm or RSD ≤ 1.0%
Nitrogen Precision1 ppm or RSD ≤ 1.0%
Sensitivity0.01 ppm
Analysis Time3 min
Pulse Furnace Power8.5 kVA
DetectorsDual-channel NDIR (O₂), TCD (N₂)
Carrier GasUltra-high-purity He
Auxiliary GasIndustrial-grade N₂
Furnace Power Supply220 VAC ±10%, 50 A
Instrument Power Supply220 VAC ±10%, 10 A
Dimensions (Main Unit)58 cm × 70 cm × 68 cm (W×D×H)
Dimensions (Furnace Unit)48 cm × 70 cm × 68 cm (W×D×H)
Weight180 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNCS (China Iron and Steel Research Institute Group)
ModelOPA-500
Optical SystemCzerny-Turner spectrometer with 500 mm focal length
Grating2700 lines/mm
Linear dispersion0.7407 nm/mm
Spectral resolution≤0.01 nm
Wavelength range160–650 nm
Excitation sourceHigh-stability continuous spark source, no pre-burn required
Data acquisition rate100 kHz
Scanning platformSiemens CNC-controlled 3-axis system (X: 360 mm, Y: 247 mm, Z: 350 mm)
Positioning accuracy (bidirectional)X-axis ±0.016/±0.010 mm, Y/Z-axis ±0.012/±0.010 mm
Repeatability (bidirectional)±0.008/±0.006 mm (X/Y/Z)
Maximum scan area300 × 200 mm
Sample weight capacity (uniform load)200 kg
Compressed air requirement0.6 MPa
Power supply220 VAC ±10%, 50 Hz
Dimensions (W×D×H)1929 × 1428 × 2016 mm
Scan patternsRectangular, circular, cross (“rice”), sector, and custom-defined contours
Data interfaceEthernet
Software complianceSupports audit trail, user access control, and electronic signature per FDA 21 CFR Part 11 requirements
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNCS
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
ModelCS5500
Measurement PrincipleInfrared Absorption Spectroscopy
Heating SystemHigh-Frequency Induction Furnace (13.56 MHz, 2.7 kVA, Adjustable Power)
Carbon Range0.6 ppm – 6.0% (0.0006–60 mg absolute, based on 1000 mg sample)
Sulfur Range0.6 ppm – 6.0% (0.0006–60 mg absolute, based on 1000 mg sample)
Sensitivity0.01 ppm
PrecisionC: ±0.3 ppm or RSD ≤ 0.5%
S±0.3 ppm or RSD ≤ 0.5%
Analysis TimeMinimum 60 s per cycle
Sample Mass Recommendation0.1–0.5 g
Carrier GasOxygen ≥99.5% purity
Assist GasNitrogen or inert gas
Power Supply220 VAC ±10%, 50/60 Hz ±1 Hz, 16 A
Dimensions620 × 760 × 800 mm (W × D × H)
Weight107 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNCS
OriginBeijing, China
ManufacturerNCS Jiangsu Testing Technology Institute Co., Ltd.
ModelCS3500G
Measurement PrincipleInfrared Absorption
Combustion SystemsHigh-Frequency Induction Furnace (18 MHz, 2.7 kVA) & Tube-Type Resistance Furnace (up to 1550 °C, max. 20 A)
Carbon RangeHF furnace — low C: 0.6 ppm–0.1 wt%
high C0.1–50 wt%
Sulfur RangeHF furnace — low S: 0.6 ppm–0.3 wt%
high S0.3–30 wt%
Resistance furnace — C0.01–100 wt%, S: 0.005–100 wt%
Sensitivity0.01 ppm
PrecisionLow-C: ±1 ppm or RSD ≤1%
High-CRSD ≤0.5%
Analysis TimeHF furnace — 30–40 s
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNCS
OriginBeijing, China
Manufacturer TypeOEM Manufacturer
Country of OriginChina
ModelNX-200S
PricingUpon Request
X-ray Tube70 kV end-window micro-focus tube
DetectorImported integrated Si-PIN detector, energy resolution ≤125 eV at 5.889 keV
Sample FormDry, homogenized powder (no digestion required)
Detection Limits (3σ, mg/kg)Cd 0.16
Battery Life8–10 h per charge (removable Li-ion)
Operating Temperature−20 °C to +40 °C
Dimensions260 W × 350 L × 300 H mm
Weight<4.5 kg
ComplianceGBZ 115–2002 (X-ray safety), GB 15618–2018 (Soil Risk Control Standard)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNCS
OriginJiangsu, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryDomestic
ModelPlasma 2000
Instrument TypeFull-Spectrum Direct-Reading ICP-OES
Detection LimitZn at 213.856 nm ≤ 0.003 mg/L
RepeatabilityRSD ≤ 0.5% (1 mg/L, n = 10)
Short-Term StabilityRSD ≤ 0.5% (500 × LOD)
Long-Term StabilityRSD ≤ 1.0% (500 × LOD)
Wavelength Range165–950 nm
Optical Resolution0.007 nm (at 200 nm)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNCS
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Product OriginDomestic (China)
ModelPlasmaMS 400
Instrument TypeQuadrupole ICP-MS
Application EnvironmentLaboratory
Mass Range (amu)2–260
Resolution (Unit Mass Resolution, amu)0.3–1.0 (Continuously Adjustable)
Detection Limits (ng·L⁻¹)Be ≤ 0.5
Sensitivity (Mcps/mg·L⁻¹)Li > 80
Short-Term Stability (RSD)≤ 2%
Long-Term Stability (RSD)≤ 3%
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNCS
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeFloor-standing
Instrument CategoryScanning-type
X-ray Tube Power4 kW
Analyzable ElementsB to U
Beryllium Window Thickness75 μm (optional ≤75 μm variants)
Goniometer Angular Reproducibilityθ–2θ independent drive
Scan RangesSC (1–118°), PC (10–148°)
Step Angles0.001°, 0.002°, 0.005°, 0.01°, 0.02°, 0.05°, 0.1°
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNCS
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
ModelCS3500
Measurement PrincipleNon-Dispersive Infrared (NDIR) Absorption
Heating SystemHigh-Frequency Induction Furnace (18 MHz, 2.7 kVA)
Carbon RangeLow-C: 0.6 ppm–0.1 %
High-C0.1 %–50 %
Sulfur RangeLow-S: 0.6 ppm–0.3 %
High-S0.3 %–30 %
Sensitivity0.01 ppm
PrecisionC: ±1 ppm or RSD < 0.5 %
S±1 ppm or RSD ≤ 1.0 %
Analysis Time30–40 s
DetectorImported Pyroelectric Solid-State IR Detector (Germany)
Optical SourceImported IR Source (USA)
Gas Flow ControlMicro-Pressure Differential Electronic Mass Flow Control
Catalytic ConversionCuO Oxidation Furnace (optional), SO₂-to-SO₃ Conversion with SO₃ Trap
Software PlatformWindows 10/11 Native GUI with LIMS Integration Support
ComplianceDesigned for ISO/IEC 17025-compliant labs
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNCS
OriginBeijing, China
ManufacturerNCS (Beijing Central Iron and Steel Research Institute)
ModelOH5500
Instrument TypeOxygen-Hydrogen Analyzer
Oxygen RangeLow-O: 0.1 ppm – 0.5 wt%
High-O0.5 wt% – 20 wt%
Hydrogen RangeLow-H: 0.1 ppm – 200 ppm
High-H200 ppm – 5000 ppm
AccuracyO₂: ±1 ppm or ±1.0% RSD
H₂±0.2 ppm or ±2.0% RSD
Sensitivity0.01 ppm
Analysis Time3 min
Pulse Furnace0–1500 A, 7.5 kVA, max. temp. 3500 °C
Detection PrincipleNon-Dispersive Infrared (NDIR) for oxygen
Carrier GasUltra-high-purity N₂ (≥99.9995%)
Sample MassTypically 1 g (adjustable to extend range)
Dimensions63 cm × 76 cm × 76 cm (W×D×H)
Weight~180 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNCS
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Origin CategoryDomestic
ModelPlasma 3000
Instrument TypeFull-Spectrum Simultaneous ICP-OES
Detection LimitSub-ppt to ppt (ng/L–µg/L)
PrecisionRSD ≤ 0.5% (1 mg/L, n = 10)
Short-Term StabilityRSD ≤ 0.5% (500×LOD)
Long-Term StabilityRSD ≤ 1.0% (4 h, 500×LOD)
Wavelength Range165–950 nm
Optical Resolution0.006 nm @ 200 nm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNCS
OriginBeijing, China
ManufacturerNCS (Beijing Central Iron and Steel Research Institute)
ModelO5500
Instrument TypeOxygen Analyzer
Analysis RangeLow-Oxygen Mode: 0.1 ppm – 0.5%
High-Oxygen Mode0.5% – 20% (range adjustable via sample mass)
Precision±1 ppm or RSD ≤ 1.0%
Sensitivity0.01 ppm
Analysis Time~3 min
Pulse Furnace0–1500 A, 7.5 kVA, max. temperature 3500 °C
Sample MassTypically 1.0 g
Carrier GasUltra-high-purity argon (≥99.9995%)
Dimensions63 cm (W) × 76 cm (D) × 76 cm (H)
Weight~180 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNCS
OriginBeijing, China
ManufacturerNCS (Central Iron and Steel Research Institute)
ModelONH3500
Instrument TypeOxygen-Nitrogen-Hydrogen Analyzer
Oxygen Range0.1 ppm–0.5% (low), 0.5%–20% (high)
Nitrogen Range0.1 ppm–0.5% (low), 0.5%–50% (high)
Hydrogen Range0.1 ppm–200 ppm (low), 200 ppm–5000 ppm (high)
AccuracyO₂: ±1 ppm or RSD ≤1.0%, N₂: ±1 ppm or RSD ≤1.0%, H₂: ±0.2 ppm or RSD ≤2.0%
Sensitivity0.01 ppm
Analysis Time3 min
Furnace Power8.5 kVA
Detection PrincipleNon-Dispersive Infrared (NDIR) for oxygen
Carrier GasUltra-High-Purity Helium or Nitrogen
Power SupplyFurnace: 220 VAC ±10%, 50 A
Electronics220 VAC ±10%, 10 A
Dimensions (Main Unit)58 × 70 × 68 cm (W×D×H)
(Furnace Unit)48 × 70 × 68 cm (W×D×H)
Weight180 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNCS
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
ModelONH5500
Instrument TypeOxygen-Nitrogen-Hydrogen Analyzer
Analysis RangeO (Low: 0.1 ppm–0.5 wt%
High0.5–20 wt%), N (Low: 0.1 ppm–0.5 wt%
High0.5–50 wt%), H: 0.1–2000 ppm
AccuracyO/N: ±1 ppm or RSD ≤1.0%
H±0.2 ppm or RSD ≤2.0%
Sensitivity0.01 ppm
Analysis Time3 min
Pulse Furnace0–1500 A, 8.5 kVA, max. temperature ≥3500 °C
Carrier GasUltra-high-purity He (≥99.9995%)
Dimensions63 × 76 × 76 cm (W×D×H)
Weight~180 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNCS
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Instrument TypeBenchtop
Excitation MethodSpark Discharge
Detector TypeCMOS Array
Focal Length500 mm
Grating Groove Density2700 lines/mm
Wavelength Range130–800 nm
Power Supply220 V ±10%, Single-Phase, 10 A, 2.5 kVA
Weight100 kg
Argon Consumption (Standby)60 mL/min
Optical SystemPaschen-Runge Mount with Holographic Grating
Temperature Control Precision±0.1 °C
Startup Time (Cold)30 min
Startup Time (Hot)5 min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNCS
OriginBeijing, China
Manufacturer TypeManufacturer
Product CategoryDomestic
ModelH5500
Instrument TypeOxygen-Nitrogen-Hydrogen Analyzer
Hydrogen Analysis RangeLow-H: 0.1–200 ppm
High-H200–5000 ppm
Hydrogen Precision±0.2 ppm or RSD ≤ 2.0%
Sensitivity0.01 ppm
Analysis Time3 min
Pulse Furnace0–1500 A, 8.5 kVA, Max Temp: 3500 °C
Carrier GasUltra-High-Purity N₂ (≥99.9995%)
Dimensions63 × 76 × 76 cm (W×D×H)
Weight~180 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNCS
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
ModelCS4600
Measurement PrincipleNon-Dispersive Infrared (NDIR) Absorption
Heating SystemVertical Tube Resistance Furnace (Max. 1500 °C, 1 °C Adjustable)
Carbon Range0.01–100 wt%
Sulfur Range0.005–100 wt%
Sensitivity0.1 ppm
PrecisionC: RSD ≤ 0.5%
SRSD ≤ 1.0%
Analysis Time60–180 s (user-configurable)
Sample Mass200–500 mg (coal, typical)
Power Supply220 VAC ±10%, 50 ±1 Hz, 20 A
Dimensions (L×W×H)814 × 710 × 1629 mm
Weight~170 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNCS
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Instrument TypeBenchtop
Excitation MethodSpark Discharge
Detector TypeCharge-Coupled Device (CCD)
Focal Length500 mm
Grating Groove Density2700 lines/mm
Wavelength Range160–500 nm
Number of Detection Channels128
Power Supply220 V ±10%, Single-Phase, 10 A, 2.5 kVA
Weight80 kg
Dimensions (W×D×H)470 × 872 × 435 mm
CCD Pixel Count3648 + 46
Pixel Size8 µm
Optical DesignPaschen–Runge Mount with Holographic Concave Grating
Spectral Resolution (Pixel Level)0.005926 nm
Linear Dispersion0.7407 nm/mm
Argon Consumption60 mL/min (Standby), Tidal Purge Mode Enabled
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNCS
OriginJiangsu, China
ManufacturerNCS (National Center for Steel & Iron Research)
Instrument TypeFloor-standing
Excitation MethodSpark Discharge
Detector TypePhotomultiplier Tube (PMT)
Focal Length750 mm
Grating Line Density2400 lines/mm
Wavelength Range120–800 nm
Number of Analytical Channels48
Dispersion0.55 nm/mm (1st order), 0.275 nm/mm (2nd order)
Optical Resolution< 0.01 nm
Selectable Spectral Lines240
Dimensions (W×D×H)139 cm × 80 cm × 117 cm
Weight~400 kg
Power Supply220 V ±10%, Single-phase, 10 A, 2.5 kVA
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNCS
OriginJiangsu, China
Manufacturer TypeManufacturer
Product TypeHandheld/Portable
ModelPORT-X720
X-ray Tube5 W, 50 kV, 200 µA max
Anode MaterialRhodium (Rh)
DetectorSilicon Drift Detector (SDD)
Energy Resolution≤155 eV
Operating Temperature−10 °C to 50 °C
Dimensions240 × 110 × 240 mm
Weight1.6 kg
Measurement ElementsMg to U
BatteryDual 7.4 V / 9600 mAh Li-ion
Runtime≥10 h
ProcessorQualcomm Snapdragon™ Octa-core (14 nm FinFET), 2.0 GHz, 1 MB L2 cache
OSAndroid 7.1
Display5.5-inch Full HD (1080p) touchscreen
ConnectivityWi-Fi 802.11 a/b/g/n/ac, Bluetooth 4.2/LE, USB
Radiation SafetyIntegrated shutter, sample proximity sensor, password-protected startup, regulatory compliance per CNAS and GBZ 188–2014
Analysis AlgorithmFundamental Parameters (FP) method with user-customizable method development capability
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNCS
OriginBeijing, China
ManufacturerNCS (Beijing) Technology Co., Ltd.
ModelON5500
Instrument TypeOxygen and Nitrogen Analyzer
Sample Mass1.0 g (adjustable)
Oxygen RangeLow-O: 0.1 ppm–0.5 %
High-O0.5 %–20 %
Nitrogen RangeLow-N: 0.1 ppm–0.5 %
High-N0.5 %–50 %
Accuracy±1 ppm or RSD ≤ 1.0 %
Sensitivity0.01 ppm
Analysis Time~3 min
Pulse Furnace0–1500 A, 7.5 kVA, max. temp. 3500 °C
Carrier GasUltra-high-purity He (≥99.9995 %)
Dimensions63 cm (W) × 76 cm (D) × 76 cm (H)
Weight~180 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNCS (China Iron and Steel Research Institute Group)
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Instrument TypeBenchtop
Excitation MethodSpark Discharge
Detector TypeCharge-Coupled Device (CCD)
Focal Length500 mm
Grating Groove Density2700 lines/mm
Wavelength Range130–800 nm (enabling detection of N, Li, Na, K, and other elements)
Spectral CoverageFull-spectrum acquisition
Pixel Array3648 + 46 pixels
Pixel Size8 µm
Optical ArchitecturePaschen-Runge mounting with holographic concave grating
Temperature Stability±0.1 °C via integrated thermostatic shielding
Argon Consumption60 mL/min in standby mode
MTBF>3000 hours
Dimensions (W×D×H)470 × 872 × 435 mm
Weight100 kg
Power Requirement220 V ±10%, single-phase, 10 A, 2.5 kVA
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNCS
OriginJiangsu, China
Manufacturer TypeManufacturer
Product TypeDomestic
ModelPORT-X710 Handheld ED-XRF Spectrometer
ApplicationField-Portable
Instrument ClassGeneral-Purpose
Industry-Specific UseMulti-Material Alloy Analysis
X-ray Tube5 W / 50 kV / 200 µA max
Target MaterialRhodium (Rh)
DetectorSi-Pin
Energy Resolution≤185 eV
Operating Temperature–10 °C to 50 °C
Dimensions240 mm (L) × 110 mm (W) × 240 mm (H)
Weight1.6 kg
Quantitative MethodFundamental Parameters (FP)
Elemental RangeTi to U
BatteryDual Li-ion, 7.4 V / 9600 mAh
Runtime≥10 h (typical)
ProcessorQualcomm Snapdragon™ octa-core, 2.0 GHz, 14 nm FinFET, 1 MB L2 cache
OSAndroid 7.1
Display5.5-inch Full HD (1080p) capacitive touchscreen
ConnectivityWi-Fi 802.11 a/b/g/n/ac, Bluetooth 4.2/LE
Radiation SafetyIntegrated shutter, sample proximity sensor, password-protected startup, certified radiation shielding per CNAS and GBZ 188–2014
Sample CompatibilitySolid metal alloys (e.g., stainless steels, low-alloy steels, Cu-based, Ni-based, Ti alloys), scrap fragments, billets, pipes, fasteners
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNCS
OriginBeijing, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Instrument TypeQuadrupole ICP-MS
Application EnvironmentLaboratory
Mass Resolution (Full Width at Half Maximum, FWHM)≤0.8 amu
Detection Limits (ng·L⁻¹)Be ≤ 2
Sensitivity (Mcps / mg·L⁻¹)Be ≥ 6
Show next