Empowering Scientific Discovery

China Iron and Steel Research Institute Group NCS Testing Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNCS
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
ModelCS5500
Measurement PrincipleInfrared Absorption Spectroscopy
Heating SystemHigh-Frequency Induction Furnace (13.56 MHz, 2.7 kVA, Adjustable Power)
Carbon Range0.6 ppm – 6.0% (0.0006–60 mg absolute, based on 1000 mg sample)
Sulfur Range0.6 ppm – 6.0% (0.0006–60 mg absolute, based on 1000 mg sample)
Sensitivity0.01 ppm
PrecisionC: ±0.3 ppm or RSD ≤ 0.5%
S±0.3 ppm or RSD ≤ 0.5%
Analysis TimeMinimum 60 s per cycle
Sample Mass Recommendation0.1–0.5 g
Carrier GasOxygen ≥99.5% purity
Assist GasNitrogen or inert gas
Power Supply220 VAC ±10%, 50/60 Hz ±1 Hz, 16 A
Dimensions620 × 760 × 800 mm (W × D × H)
Weight107 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNCS
OriginBeijing, China
ManufacturerNCS Jiangsu Testing Technology Institute Co., Ltd.
ModelCS3500G
Measurement PrincipleInfrared Absorption
Combustion SystemsHigh-Frequency Induction Furnace (18 MHz, 2.7 kVA) & Tube-Type Resistance Furnace (up to 1550 °C, max. 20 A)
Carbon RangeHF furnace — low C: 0.6 ppm–0.1 wt%
high C0.1–50 wt%
Sulfur RangeHF furnace — low S: 0.6 ppm–0.3 wt%
high S0.3–30 wt%
Resistance furnace — C0.01–100 wt%, S: 0.005–100 wt%
Sensitivity0.01 ppm
PrecisionLow-C: ±1 ppm or RSD ≤1%
High-CRSD ≤0.5%
Analysis TimeHF furnace — 30–40 s
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNCS
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
ModelCS3500
Measurement PrincipleNon-Dispersive Infrared (NDIR) Absorption
Heating SystemHigh-Frequency Induction Furnace (18 MHz, 2.7 kVA)
Carbon RangeLow-C: 0.6 ppm–0.1 %
High-C0.1 %–50 %
Sulfur RangeLow-S: 0.6 ppm–0.3 %
High-S0.3 %–30 %
Sensitivity0.01 ppm
PrecisionC: ±1 ppm or RSD < 0.5 %
S±1 ppm or RSD ≤ 1.0 %
Analysis Time30–40 s
DetectorImported Pyroelectric Solid-State IR Detector (Germany)
Optical SourceImported IR Source (USA)
Gas Flow ControlMicro-Pressure Differential Electronic Mass Flow Control
Catalytic ConversionCuO Oxidation Furnace (optional), SO₂-to-SO₃ Conversion with SO₃ Trap
Software PlatformWindows 10/11 Native GUI with LIMS Integration Support
ComplianceDesigned for ISO/IEC 17025-compliant labs
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNCS
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
ModelCS4600
Measurement PrincipleNon-Dispersive Infrared (NDIR) Absorption
Heating SystemVertical Tube Resistance Furnace (Max. 1500 °C, 1 °C Adjustable)
Carbon Range0.01–100 wt%
Sulfur Range0.005–100 wt%
Sensitivity0.1 ppm
PrecisionC: RSD ≤ 0.5%
SRSD ≤ 1.0%
Analysis Time60–180 s (user-configurable)
Sample Mass200–500 mg (coal, typical)
Power Supply220 VAC ±10%, 50 ±1 Hz, 20 A
Dimensions (L×W×H)814 × 710 × 1629 mm
Weight~170 kg
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0