Empowering Scientific Discovery

China Iron and Steel Research Institute Group NCS Testing Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNCS
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Instrument TypeBenchtop
Excitation MethodSpark Discharge
Detector TypeCMOS Array
Focal Length500 mm
Grating Groove Density2700 lines/mm
Wavelength Range130–800 nm
Power Supply220 V ±10%, Single-Phase, 10 A, 2.5 kVA
Weight100 kg
Argon Consumption (Standby)60 mL/min
Optical SystemPaschen-Runge Mount with Holographic Grating
Temperature Control Precision±0.1 °C
Startup Time (Cold)30 min
Startup Time (Hot)5 min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNCS
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Instrument TypeBenchtop
Excitation MethodSpark Discharge
Detector TypeCharge-Coupled Device (CCD)
Focal Length500 mm
Grating Groove Density2700 lines/mm
Wavelength Range160–500 nm
Number of Detection Channels128
Power Supply220 V ±10%, Single-Phase, 10 A, 2.5 kVA
Weight80 kg
Dimensions (W×D×H)470 × 872 × 435 mm
CCD Pixel Count3648 + 46
Pixel Size8 µm
Optical DesignPaschen–Runge Mount with Holographic Concave Grating
Spectral Resolution (Pixel Level)0.005926 nm
Linear Dispersion0.7407 nm/mm
Argon Consumption60 mL/min (Standby), Tidal Purge Mode Enabled
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNCS
OriginJiangsu, China
ManufacturerNCS (National Center for Steel & Iron Research)
Instrument TypeFloor-standing
Excitation MethodSpark Discharge
Detector TypePhotomultiplier Tube (PMT)
Focal Length750 mm
Grating Line Density2400 lines/mm
Wavelength Range120–800 nm
Number of Analytical Channels48
Dispersion0.55 nm/mm (1st order), 0.275 nm/mm (2nd order)
Optical Resolution< 0.01 nm
Selectable Spectral Lines240
Dimensions (W×D×H)139 cm × 80 cm × 117 cm
Weight~400 kg
Power Supply220 V ±10%, Single-phase, 10 A, 2.5 kVA
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNCS (China Iron and Steel Research Institute Group)
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Instrument TypeBenchtop
Excitation MethodSpark Discharge
Detector TypeCharge-Coupled Device (CCD)
Focal Length500 mm
Grating Groove Density2700 lines/mm
Wavelength Range130–800 nm (enabling detection of N, Li, Na, K, and other elements)
Spectral CoverageFull-spectrum acquisition
Pixel Array3648 + 46 pixels
Pixel Size8 µm
Optical ArchitecturePaschen-Runge mounting with holographic concave grating
Temperature Stability±0.1 °C via integrated thermostatic shielding
Argon Consumption60 mL/min in standby mode
MTBF>3000 hours
Dimensions (W×D×H)470 × 872 × 435 mm
Weight100 kg
Power Requirement220 V ±10%, single-phase, 10 A, 2.5 kVA
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0