BrandNCS
OriginJiangsu, China
Manufacturer TypeManufacturer
Instrument TypeOxygen and Nitrogen Analyzer
ModelON3500
Oxygen Range (Low)0.1 ppm–0.5%
Oxygen Range (High)0.5%–20%
Nitrogen Range (Low)0.1 ppm–0.5%
Nitrogen Range (High)0.5%–50%
Oxygen Precision1 ppm or RSD ≤ 1.0%
Nitrogen Precision1 ppm or RSD ≤ 1.0%
Sensitivity0.01 ppm
Analysis Time3 min
Pulse Furnace Power8.5 kVA
DetectorsDual-channel NDIR (O₂), TCD (N₂)
Carrier GasUltra-high-purity He
Auxiliary GasIndustrial-grade N₂
Furnace Power Supply220 VAC ±10%, 50 A
Instrument Power Supply220 VAC ±10%, 10 A
Dimensions (Main Unit)58 cm × 70 cm × 68 cm (W×D×H)
Dimensions (Furnace Unit)48 cm × 70 cm × 68 cm (W×D×H)
Weight180 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNCS
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
ModelCS5500
Measurement PrincipleInfrared Absorption Spectroscopy
Heating SystemHigh-Frequency Induction Furnace (13.56 MHz, 2.7 kVA, Adjustable Power)
Carbon Range0.6 ppm – 6.0% (0.0006–60 mg absolute, based on 1000 mg sample)
Sulfur Range0.6 ppm – 6.0% (0.0006–60 mg absolute, based on 1000 mg sample)
Sensitivity0.01 ppm
PrecisionC: ±0.3 ppm or RSD ≤ 0.5%
S±0.3 ppm or RSD ≤ 0.5%
Analysis TimeMinimum 60 s per cycle
Sample Mass Recommendation0.1–0.5 g
Carrier GasOxygen ≥99.5% purity
Assist GasNitrogen or inert gas
Power Supply220 VAC ±10%, 50/60 Hz ±1 Hz, 16 A
Dimensions620 × 760 × 800 mm (W × D × H)
Weight107 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNCS
OriginBeijing, China
ManufacturerNCS Jiangsu Testing Technology Institute Co., Ltd.
ModelCS3500G
Measurement PrincipleInfrared Absorption
Combustion SystemsHigh-Frequency Induction Furnace (18 MHz, 2.7 kVA) & Tube-Type Resistance Furnace (up to 1550 °C, max. 20 A)
Carbon RangeHF furnace — low C: 0.6 ppm–0.1 wt%
high C0.1–50 wt%
Sulfur RangeHF furnace — low S: 0.6 ppm–0.3 wt%
high S0.3–30 wt%
Resistance furnace — C0.01–100 wt%, S: 0.005–100 wt%
Sensitivity0.01 ppm
PrecisionLow-C: ±1 ppm or RSD ≤1%
High-CRSD ≤0.5%
Analysis TimeHF furnace — 30–40 s
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNCS
OriginBeijing, China
Manufacturer TypeOEM Manufacturer
Country of OriginChina
ModelNX-200S
PricingUpon Request
X-ray Tube70 kV end-window micro-focus tube
DetectorImported integrated Si-PIN detector, energy resolution ≤125 eV at 5.889 keV
Sample FormDry, homogenized powder (no digestion required)
Detection Limits (3σ, mg/kg)Cd 0.16
Battery Life8–10 h per charge (removable Li-ion)
Operating Temperature−20 °C to +40 °C
Dimensions260 W × 350 L × 300 H mm
Weight<4.5 kg
ComplianceGBZ 115–2002 (X-ray safety), GB 15618–2018 (Soil Risk Control Standard)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNCS
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
ModelCS3500
Measurement PrincipleNon-Dispersive Infrared (NDIR) Absorption
Heating SystemHigh-Frequency Induction Furnace (18 MHz, 2.7 kVA)
Carbon RangeLow-C: 0.6 ppm–0.1 %
High-C0.1 %–50 %
Sulfur RangeLow-S: 0.6 ppm–0.3 %
High-S0.3 %–30 %
Sensitivity0.01 ppm
PrecisionC: ±1 ppm or RSD < 0.5 %
S±1 ppm or RSD ≤ 1.0 %
Analysis Time30–40 s
DetectorImported Pyroelectric Solid-State IR Detector (Germany)
Optical SourceImported IR Source (USA)
Gas Flow ControlMicro-Pressure Differential Electronic Mass Flow Control
Catalytic ConversionCuO Oxidation Furnace (optional), SO₂-to-SO₃ Conversion with SO₃ Trap
Software PlatformWindows 10/11 Native GUI with LIMS Integration Support
ComplianceDesigned for ISO/IEC 17025-compliant labs
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNCS
OriginBeijing, China
ManufacturerNCS (Beijing Central Iron and Steel Research Institute)
ModelOH5500
Instrument TypeOxygen-Hydrogen Analyzer
Oxygen RangeLow-O: 0.1 ppm – 0.5 wt%
High-O0.5 wt% – 20 wt%
Hydrogen RangeLow-H: 0.1 ppm – 200 ppm
High-H200 ppm – 5000 ppm
AccuracyO₂: ±1 ppm or ±1.0% RSD
H₂±0.2 ppm or ±2.0% RSD
Sensitivity0.01 ppm
Analysis Time3 min
Pulse Furnace0–1500 A, 7.5 kVA, max. temp. 3500 °C
Detection PrincipleNon-Dispersive Infrared (NDIR) for oxygen
Carrier GasUltra-high-purity N₂ (≥99.9995%)
Sample MassTypically 1 g (adjustable to extend range)
Dimensions63 cm × 76 cm × 76 cm (W×D×H)
Weight~180 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNCS
OriginBeijing, China
ManufacturerNCS (Beijing Central Iron and Steel Research Institute)
ModelO5500
Instrument TypeOxygen Analyzer
Analysis RangeLow-Oxygen Mode: 0.1 ppm – 0.5%
High-Oxygen Mode0.5% – 20% (range adjustable via sample mass)
Precision±1 ppm or RSD ≤ 1.0%
Sensitivity0.01 ppm
Analysis Time~3 min
Pulse Furnace0–1500 A, 7.5 kVA, max. temperature 3500 °C
Sample MassTypically 1.0 g
Carrier GasUltra-high-purity argon (≥99.9995%)
Dimensions63 cm (W) × 76 cm (D) × 76 cm (H)
Weight~180 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNCS
OriginBeijing, China
ManufacturerNCS (Central Iron and Steel Research Institute)
ModelONH3500
Instrument TypeOxygen-Nitrogen-Hydrogen Analyzer
Oxygen Range0.1 ppm–0.5% (low), 0.5%–20% (high)
Nitrogen Range0.1 ppm–0.5% (low), 0.5%–50% (high)
Hydrogen Range0.1 ppm–200 ppm (low), 200 ppm–5000 ppm (high)
AccuracyO₂: ±1 ppm or RSD ≤1.0%, N₂: ±1 ppm or RSD ≤1.0%, H₂: ±0.2 ppm or RSD ≤2.0%
Sensitivity0.01 ppm
Analysis Time3 min
Furnace Power8.5 kVA
Detection PrincipleNon-Dispersive Infrared (NDIR) for oxygen
Carrier GasUltra-High-Purity Helium or Nitrogen
Power SupplyFurnace: 220 VAC ±10%, 50 A
Electronics220 VAC ±10%, 10 A
Dimensions (Main Unit)58 × 70 × 68 cm (W×D×H)
(Furnace Unit)48 × 70 × 68 cm (W×D×H)
Weight180 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNCS
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
ModelONH5500
Instrument TypeOxygen-Nitrogen-Hydrogen Analyzer
Analysis RangeO (Low: 0.1 ppm–0.5 wt%
High0.5–20 wt%), N (Low: 0.1 ppm–0.5 wt%
High0.5–50 wt%), H: 0.1–2000 ppm
AccuracyO/N: ±1 ppm or RSD ≤1.0%
H±0.2 ppm or RSD ≤2.0%
Sensitivity0.01 ppm
Analysis Time3 min
Pulse Furnace0–1500 A, 8.5 kVA, max. temperature ≥3500 °C
Carrier GasUltra-high-purity He (≥99.9995%)
Dimensions63 × 76 × 76 cm (W×D×H)
Weight~180 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNCS
OriginBeijing, China
Manufacturer TypeManufacturer
Product CategoryDomestic
ModelH5500
Instrument TypeOxygen-Nitrogen-Hydrogen Analyzer
Hydrogen Analysis RangeLow-H: 0.1–200 ppm
High-H200–5000 ppm
Hydrogen Precision±0.2 ppm or RSD ≤ 2.0%
Sensitivity0.01 ppm
Analysis Time3 min
Pulse Furnace0–1500 A, 8.5 kVA, Max Temp: 3500 °C
Carrier GasUltra-High-Purity N₂ (≥99.9995%)
Dimensions63 × 76 × 76 cm (W×D×H)
Weight~180 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNCS
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
ModelCS4600
Measurement PrincipleNon-Dispersive Infrared (NDIR) Absorption
Heating SystemVertical Tube Resistance Furnace (Max. 1500 °C, 1 °C Adjustable)
Carbon Range0.01–100 wt%
Sulfur Range0.005–100 wt%
Sensitivity0.1 ppm
PrecisionC: RSD ≤ 0.5%
SRSD ≤ 1.0%
Analysis Time60–180 s (user-configurable)
Sample Mass200–500 mg (coal, typical)
Power Supply220 VAC ±10%, 50 ±1 Hz, 20 A
Dimensions (L×W×H)814 × 710 × 1629 mm
Weight~170 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNCS
OriginBeijing, China
ManufacturerNCS (Beijing) Technology Co., Ltd.
ModelON5500
Instrument TypeOxygen and Nitrogen Analyzer
Sample Mass1.0 g (adjustable)
Oxygen RangeLow-O: 0.1 ppm–0.5 %
High-O0.5 %–20 %
Nitrogen RangeLow-N: 0.1 ppm–0.5 %
High-N0.5 %–50 %
Accuracy±1 ppm or RSD ≤ 1.0 %
Sensitivity0.01 ppm
Analysis Time~3 min
Pulse Furnace0–1500 A, 7.5 kVA, max. temp. 3500 °C
Carrier GasUltra-high-purity He (≥99.9995 %)
Dimensions63 cm (W) × 76 cm (D) × 76 cm (H)
Weight~180 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNCS (China Iron & Steel Research Institute Group – National Center for Steel Quality Inspection)
OriginBeijing, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Instrument TypePulse-heated Inert Gas Fusion Nitrogen Analyzer
Measurement PrincipleThermal Conductivity Detection (TCD) after High-Temperature Inert Gas Fusion
Analysis RangeLow-N: 0.1 ppm – 0.5%
High-N0.5% – 50%
Precision±1 ppm or RSD ≤ 1.0%
Sensitivity0.01 ppm
Analysis Time~3 min per sample
Furnace Power0–1500 A, 8.5 kVA, max. temperature 3500 °C
Sample MassTypically 1 g (adjustable per matrix and concentration)
Carrier GasUltra-high-purity helium (≥99.9995%)
Dimensions63 cm (W) × 76 cm (D) × 76 cm (H)
Weight~180 kg