| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | CBS-A |
| Instrument Type | Liquid-Phase Fraction Collector |
| Collection Modes | Time-Based, Drop-Based, Peak-Based, Program-Controlled |
| Tube Capacity | 12 mL (standard, 100-tube rack) |
| Timing Range | 1 s – 999 h 59 min 59 s |
| Drop Counting Range | 1–999 drops |
| Programmable Methods | 10 user-defined protocols |
| Movement Mechanism | Suspended X-Y stepper-driven positioning |
| Display | Large-backlit Chinese-language LCD (blue membrane) |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 345 × 360 × 270 mm |
| Weight | 14 kg |
| Data Retention | 10 years after power loss |
| Continuous Operation | >200 hours |
| Compliance | Designed for GLP-compliant chromatography workflows |
| Optional Racks | 16-tube (100 mL/tube), 36-tube (50 mL/tube), 169-tube (5 mL/tube) |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | CBS-B |
| Instrument Type | Liquid-Phase Fraction Collector |
| Collection Modes | Time-Based, Drop-Based, Peak-Based, Programmable Control |
| Tube Capacity | 100 × 12 mL (standard), optional trays: 16 × 100 mL, 36 × 50 mL, 169 × 5 mL |
| Timing Range | 1 s – 999 h 59 min 59 s |
| Drop Counting Range | 1–999 drops |
| Peak Threshold Range | 1–200 mV |
| Programmable Segments | 1–10 |
| Movement Mechanism | Suspended X-Y Positioning |
| Valve Type | 12 V DC Solenoid |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 345 × 360 × 270 mm |
| Weight | 14 kg |
| Data Retention | ≥10 years after power loss |
| Continuous Operation | >200 hours |
| Compliance | Designed for GLP-compliant chromatography workflows |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | DBS-100 |
| Fraction Collection Type | Liquid-phase |
| Collection Modes | Time-based, Drop-counting, Peak-triggered |
| Tube Capacity | 100 × 12 mL |
| Time Range | 1 s – 199 h 59 min 59 s |
| Drop Range | 1–9999 drops |
| Peak Threshold Range | 0–100 mV |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 265 × 390 × 390 mm |
| Weight | 8.35 kg |
| Data Retention After Power Loss | 10 years |
| Display | Large Blue-backlit Chinese LCD |
| Tube Tray | Circular, Digitally Labeled (00–99) |
| Continuous Operation Time | >200 h |
| Housing Material | ABS Plastic (Injection-molded, Closed-loop Design) |
| Compliance | Designed for GLP-aligned chromatographic workflows |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | DBS-160 |
| Fraction Collection Modes | Time-based, Drop-counting, Peak-triggered |
| Max. Tube Capacity | 160 × 5 mL |
| Time Range | 1 s – 199 h 59 min 59 s |
| Drop Count Range | 1–9999 drops |
| Peak Threshold Range | 0–100 mV |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 265 × 390 × 390 mm |
| Weight | 8.35 kg |
| Data Retention After Power Loss | ≥10 years |
| Continuous Operation | >200 hours |
| Display | Large Backlit Blue-Membrane Chinese LCD |
| Tube Rack | Circular, Digitally Labeled (001–160) |
| Housing Material | ABS Plastic (Injection-Molded, Closed-Structure) |
| Compliance | Designed for GLP-compliant preparative chromatography workflows |
| Brand | Jiapeng |
|---|---|
| Model | JP-FCD100 |
| Type | Liquid-phase Fraction Collector |
| Collection Modes | Time-based, Drop-counting, UV/absorbance Threshold-triggered |
| Tube Capacity | 100 × 12 mL |
| Touchscreen | 5.5-inch capacitive LCD |
| Timing Range | 1 s – 199 h 59 min 59 s |
| Drop Count Range | 1–9999 drops |
| Threshold Range | ±6 AU (requires external UV detector) |
| Peak Trigger Input | 0–100 mV analog signal |
| Delay Volume Compensation | Software-configurable |
| Valve Type | PEEK fluidic solenoid valve (organic solvent compatible) |
| Continuous Operation | >200 hours |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 265 × 390 × 390 mm |
| Weight | 8.35 kg |
| Brand | Jiapeng |
|---|---|
| Model | JP-FCD160 |
| Type | Liquid-phase Fraction Collector |
| Collection Modes | Time-based, Drop-counting, UV/absorbance threshold-triggered |
| Tube Capacity | 160 × 5 mL |
| Touchscreen Interface | 5.5-inch capacitive LCD |
| UV Input Range | 0–100 mV (analog) / –6 to +6 AU (digital, requires external UV detector) |
| Timer Range | 1 s – 199 h 59 min 59 s |
| Drop Count Range | 1–9999 drops |
| Delay Volume Compensation | Adjustable in software |
| Valve Type | PEEK solenoid valve (organic solvent compatible, drip-free switching) |
| Continuous Operation | >200 h |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 265 × 390 × 390 mm |
| Weight | 8.35 kg |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | SBS-100 |
| Fraction Collection Type | Liquid-phase |
| Collection Modes | Time-based, Drop-counting, Peak-triggered |
| Tube Capacity | 12 mL per tube |
| Number of Tubes | 100-position circular rack |
| Time Range | 1 s – 199 h 59 min 59 s |
| Drop Count Range | 1–9999 drops |
| Peak Detection Input | 0–100 mV analog signal |
| Display | Large blue-backlit Chinese-language LCD |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 265 × 390 × 390 mm |
| Weight | 8.35 kg |
| Data Retention After Power Loss | ≥10 years |
| Continuous Operation Time | >200 hours |
| Housing Material | ABS polymer, injection-molded, fully enclosed |
| Compliance | Designed for GLP-compliant chromatography workflows in R&D and pilot-scale purification |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | SBS-160 |
| Fraction Capacity | 160 × 5 mL tubes |
| Timing Range | 1 s – 199 h 59 min 59 s |
| Droplet Counting Range | 1–9999 drops |
| Peak Trigger Range | 0–100 mV (for SBS-100 variant |
| Display | Large blue-backlit Chinese LCD |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 265 × 390 × 390 mm |
| Weight | 8.35 kg |
| Data Retention After Power Loss | ≥10 years |
| Continuous Operation Time | >200 hours |
| Housing Material | ABS plastic (injection-molded, fully enclosed) |
| Tube Rack | Circular, digitally numbered (1–160), compatible with standard 12 × 75 mm or 13 × 100 mm test tubes |
| External Trigger Interface | RS-232 COM port for synchronized control with peristaltic pumps (e.g., Keebio constant-flow pumps) |
| Valve Type | Solenoid-actuated fluid cutoff valve (optional solvent-resistant version available) |
| Brand | Jinpu |
|---|---|
| Origin | Shandong, China |
| Model | HS-72A |
| Instrument Type | Dynamic Headspace Sampler |
| Automation Level | Fully Automated |
| Vial Heating Range | Ambient to 220 °C (1 °C increments) |
| Valve & Transfer Line Temperature Control Range | Ambient to 220 °C (1 °C increments) |
| Sample Loop Volume | 1 mL |
| Vial Capacity | 72 positions |
| Vial Size | 20 mL (10 mL compatible) |
| Temperature Control Accuracy | ±0.1 °C |
| RSD | ≤1.5% (ethanol in water) |
| Pressurization Range | 0–0.4 MPa (continuously adjustable) |
| Agitation Speed | 60–600 rpm (10-step adjustment) |
| Heating Zones | 12 overlapping heated positions with programmable agitation |
| Brand | Jingke Ruida (Kyocera) |
|---|---|
| Origin | Beijing, China |
| Model | JK-O1 |
| Instrument Type | Dynamic Headspace Sampler |
| Automation Level | Fully Automatic |
| Sample Tray Capacity | 12 positions |
| Vial Sizes Supported | 10 mL and 20 mL |
| Valve Oven Temperature Range | Ambient to 180 °C (1 °C increments, ±0.3 °C stability) |
| Transfer Line Temperature Range | Ambient to 180 °C (1 °C increments, ±0.5 °C stability) |
| Sample Loop Volume | 1.0 mL (configurable) |
| Sample Loop Material | Stainless steel with 0.2 mm inner diameter tubing |
| Compliance | Compatible with global GC systems per ASTM D3699, USP <467>, ISO 11843-2 |
| Brand | JiaPeng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | JP-KeebioFC |
| Instrument Type | Mixed-Mode Fraction Collector |
| Collection Mechanism | Suspended X-Y Robotic Movement |
| Display | 8.5-inch HD Touchscreen |
| Tube Capacity Options | 100 × 12 mL (standard), 16 × 100 mL (optional), 36 × 50 mL (optional), 169 × 5 mL (optional) |
| Timing Range | 1 s – 999 h 59 min 59 s |
| Drop Counting Range | 1–9999 drops |
| Peak Threshold Range | 1–200 mV |
| Programmable Segments | 1–10 segments |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 385 × 390 × 310 mm |
| Weight | 14 kg |
| Continuous Operation Time | >200 hours |
| Data Retention (Power Loss) | Up to 10 years |
| Valve Actuation | 12 V DC Solenoid |
| Tube Tray Design | Modular Square Rack with Integrated Waste Channel |
| Corrosion Resistance | Compatible with aqueous and common organic solvents (e.g., methanol, acetonitrile, chloroform, ethyl acetate) |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | JPS-700 |
| Instrument Type | Curie-Point Pyrolyzer |
| Maximum Sample Capacity | 40 samples |
| Pyrolysis Temperature Range | Up to 400 °C (typical operating range ≤300 °C) |
| Heating Method | High-Frequency Induction |
| RF Frequency | 600 kHz |
| RF Power Output | 48 W |
| Pyrolysis Duration Control | 1–9,999 s |
| Inter-Analysis Interval | 0.01–999.99 min |
| Carrier Gas Purge | Dual-point dry air purge (pressure ≥0.4 MPa) |
| GC Interface | Universal GC-mount adapter |
| Compliance | Compatible with ASTM D7250, ISO 11348, and USP <621> chromatographic system integration requirements |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | JX-1 |
| Pricing | Upon Request |
| Desorption Temperature Range | Ambient to 400 °C |
| Temperature Control Accuracy | < ±0.5 °C |
| Carrier Gas Flow Rate | 10–160 mL/min (adjustable) |
| Desorption Efficiency | ≥85% |
| Sample Tube Dimensions | Ø6 mm, length >120 mm |
| Compatible Carrier Gas | High-purity N₂ (≥99.999%) |
| Power Supply | 220 V ±10%, 50–60 Hz |
| Operating Ambient | 10–40 °C, ≤85% RH |
| Unit Dimensions | 170 × 200 × 150 mm |
| Sampling Method | Manual injection |
| Flow Control | Precision rotameter |
| Tubing Material | Passivated and electropolished 316 stainless steel |
| Sealing Material | Silicone rubber O-rings (low-outgassing) |
| Interface Design | Direct coupling between desorption tube and 100 mL gas-tight syringe (zero-dead-volume transfer) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | JX-3 |
| Pricing | Available Upon Request |
| Desorption Temperature Range | Ambient to 380 °C |
| Valve Oven Temperature Range | Ambient to 150 °C |
| Transfer Line Temperature Range | Ambient to 150 °C |
| Calibration Simulation Time | 0–60 min |
| Desorption Heating Time | 0–60 min |
| Sample Injection Time | 0–10 min |
| Trap Tube Dimensions | Ø6 mm, Length >120 mm |
| Brand | Kezhe / KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | ELSD-2000KS |
| Instrument Type | Evaporative Light Scattering Detector (ELSD) |
| Wavelength Range | 195–600 nm |
| Detection Method | Dual-beam |
| Light Source | Xenon lamp |
| Laser Wavelength (Standard) | 650 nm |
| Gas Flow Range | 0–5 L/min |
| Nebulization Pressure | 0–100 psi |
| Temperature Control Range | Ambient to 150 °C (±1 °C resolution) |
| Mobile Phase Flow Rate Compatibility | 0–5 mL/min |
| Detector | Imported large-area silicon photodiode |
| Power Supply | 220 V AC |
| Compatible Carrier Gases | Compressed air or nitrogen |
| Core Components | Stainless-steel evaporation tube, maintenance-free stainless-steel nozzle, laser source, photodetector, dedicated ELSD-2000KS chromatography workstation |
| Brand | Kezhe / KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | ELSD-3000KS |
| Instrument Type | Evaporative Light Scattering Detector (ELSD) |
| Wavelength Range | 195–600 nm |
| Detection Method | Dual-beam |
| Light Source | Xenon Lamp |
| Brand | Kezhe / KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Evaporative Light Scattering Detector (ELSD) |
| Wavelength Range | 195–600 nm |
| Detection Mode | Dual-Beam |
| Light Source | Xenon Lamp |
| Gas Flow Range | 0–5 L/min |
| Nebulizer Pressure | 0–100 psi |
| Temperature Control Range | Ambient to 150 °C (±1 °C resolution) |
| Mobile Phase Flow Rate Compatibility | 0–0.5 mL/min |
| Light Source (Standard) | 650 nm Laser |
| Detector | Imported Photomultiplier Tube (PMT) |
| Power Supply | 220 V AC |
| Compatible Carrier Gases | Compressed Air or Nitrogen |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Fluorescence Detector (FD) |
| Wavelength Range | 195–650 nm (Excitation), 200–800 nm (Emission) |
| Measurement Mode | Dual-Beam |
| Light Source | Xenon Lamp |
| Flow Rate Range | 0–10 mL/min |
| Flow Accuracy | ±0.3% |
| Flow Precision (RSD) | ≤0.1% |
| Injection Valve Pressure Rating | 35.0 MPa (5000 psi) |
| Spectral Bandwidth | 10 nm / 20 nm |
| AD Resolution | 24-bit |
| Software Platform | FStar-2000 Chromatography Data System (CDS) for Windows 7/8/10 |
| Compliance | Fully aligned with Chinese Pharmacopoeia (2015 Edition), GLP/GMP principles, and FDA 21 CFR Part 11 audit trail requirements |
| Brand | Kezhe Shanghai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | KH-FL20E |
| Instrument Type | Fluorescence Detector (FD) |
| Excitation Wavelength Range | 190–800 nm |
| Emission Wavelength Range | 190–800 nm |
| Spectral Bandwidth Options | 2 / 5 / 10 / 20 nm |
| Wavelength Accuracy | ±0.2 nm |
| Wavelength Precision | ±1 nm |
| Light Source | Solid-State Discharge Lamp |
| Monochromator | 1200-line Holographic Grating |
| Detector | Photomultiplier Tube (PMT) |
| AD/DA Resolution | 24-bit |
| Temperature Control Range (Flow Cell) | Ambient to 50 °C |
| Compliance | Meets GMP/GLP requirements |
| Brand | Kezhe Shanghai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | KH-FL30E |
| Instrument Type | Fluorescence Detector (FD) |
| Wavelength Range | 190–900 nm (Excitation & Emission) |
| Measurement Mode | Dual-Beam |
| Light Source | 150 W DC Xenon Lamp |
| Spectral Bandwidth | 10 nm / 15 nm |
| Wavelength Accuracy | ±0.2 nm |
| Wavelength Precision | ±1 nm |
| Monochromator | 1200-line Holographic Grating |
| Detector | Photomultiplier Tube (PMT) |
| AD/DA Resolution | 24-bit |
| Temperature Control Range (Flow Cell) | Ambient to 50 °C |
| Software | FM-2000 Chromatography Workstation |
| Compliance | Chinese Pharmacopoeia (2010 & 2015 Editions), GLP/GMP-ready, LIMS-compatible, FDA 21 CFR Part 11 support (audit trail & electronic signature enabled) |
| Brand | Kezhe Shanghai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | KH-FL30Plus |
| Instrument Type | Fluorescence Detector (FD) |
| Wavelength Range | 190–900 nm (Excitation & Emission) |
| Wavelength Accuracy | ±0.2 nm |
| Wavelength Precision | ±1 nm |
| Spectral Bandwidth | 10 nm / 15 nm |
| Light Source | 150 W DC Xenon Lamp |
| Monochromator | 1200-line Holographic Grating |
| Detector | Photomultiplier Tube (PMT) |
| AD/DA Resolution | 24-bit |
| Temperature Control Range | Ambient to 50 °C (Optional) |
| Compliance | Chinese Pharmacopoeia 2010/2015 Edition, GLP/GMP-Ready, LIMS-Compatible |
| Brand | Kezhe Shanghai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | KH-FL50E |
| Instrument Type | Fluorescence Detector (FD) |
| Excitation/Emission Wavelength Range | 190–900 nm |
| Detection Modes | Fluorescence, Phosphorescence, Chemiluminescence |
| Light Source | 150 W DC Xenon Lamp or 5 W Pulsed Xenon Lamp |
| Monochromator | 1200-line Holographic Grating |
| Spectral Bandwidth (Excitation & Emission) | 5/10/15/20 nm selectable |
| Wavelength Accuracy | ±0.2 nm |
| Wavelength Precision | ±1 nm |
| AD/DA Resolution | 24-bit |
| Flow Cell Temperature Control | 5–50 °C |
| Detector Options | Single-Photon Counting Module (SPCM) or Variable-Voltage High-Sensitivity PMT |
| Compliance | Chinese Pharmacopoeia 2010/2015, GLP/GMP-ready, LIMS-compatible |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Evaporative Light Scattering Detector (ELSD) |
| Model | ELSD-5000KS |
| Wavelength Range | 200–800 nm (standard), optional 200–400 nm or 200–1100 nm |
| Detection Mode | Dual-beam |
| Light Source | Standard 650 nm laser + D₂/W lamp combination |
| Nebulizer Gas Flow | 0–5 L/min |
| Nebulizer Pressure | 0–150 psi |
| Drift Tube Temperature | Ambient to 200 °C (1 °C resolution) |
| Mobile Phase Flow Rate | 0–200 mL/min |
| Fraction Capacity | 160 positions |
| Collection Mechanism | X-Y-Z three-axis robotic arm |
| Gas Supply | Compressed air or nitrogen |
| Software | ELSD-5000KS Preparative Chromatography Workstation |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | UV+2000 |
| Instrument Type | Fluorescence Detector (FD) Compatible Derivatization Device |
| Wavelength Range | 195–600 nm |
| Measurement Mode | Dual-Beam |
| Light Source | Xenon Lamp |
| Maximum Flow Rate | 2 mL/min (customizable) |
| Brand | Kezhe Shanghai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | KH-ZY10E |
| Instrument Type | Fluorescence Detector-Compatible Post-Column Derivatization System |
| Temperature Range | Ambient to 150 °C |
| Temperature Accuracy | ±0.25 °C |
| Temperature Resolution | ±0.1 °C |
| Derivatization Pump Flow Rate | 0–10 mL/min |
| Flow Repeatability | ±0.1% |
| Reaction Coil Length | 10 m |
| Reactor Configuration | Modular, Single or Dual Cartridge Options |
| Mixing Architecture | Sealed Continuous-Loop Multi-Directional Flow Reactor |
| Peak Broadening Reduction | Optimized via Low-Dispersion Reaction Core Design |
| Brand | Kromasil |
|---|---|
| Origin | Sweden |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Kromasil |
| Pricing | Available Upon Request |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | AMTK Multifunctional HPLC Autosampler |
| Pricing | Available Upon Request |
| Sample Capacity | 120 × 2 mL vials (2 × 60-position racks) |
| Injection Volume Range | 0.1–1000 µL |
| Precision | RSD < 0.5% (full-loop & partial-loop modes) |
| Carryover | < 0.01% |
| Linearity | R² > 0.999 |
| Injection Modes | Full-loop, Partial-loop, Needle-Over-Loop (NOL), and Zero-Dead-Volume (ZDV) |
| Quantitative Loop Options | 20, 50, 100 (standard), 200, 500 µL |
| Syringe Pump Options | 100, 250 (standard), 1000 µL |
| Valve Switching Time | < 100 ms |
| Positioning Accuracy | < 0.3 mm (XYZ 3-axis stepper motor control) |
| Wash Protocol | Dual-wall (inner + outer needle) wash with unlimited cycles |
| Dimensions | 300 × 230 × 505 mm (L × H × W) |
| Power | AC 220 V, 50 Hz |
| Communication | LAN & RS-232 |
| Software | AMTK Chromatography Workstation |
| pH Compatibility | 1–14 |
| System Integration | Fully compatible with Agilent, Waters, Shimadzu, Thermo Fisher, PerkinElmer, Elite, and other HPLC/UHPLC/IC platforms |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Model | ATD-01/20 |
| Instrument Type | Dual-Stage Thermal Desorber |
| Desorption Temperature Range | Ambient to 400 °C |
| Cryo-Focusing Trap Temperature Range | –35 °C to 400 °C |
| Desorption Recovery Rate | >98% (compound-dependent) |
| Sample Capacity | 1–20 adsorption tubes |
| Valve System | Motorized 6-port switching valve + solenoid valves |
| Transfer Line Temp. Control | Ambient to 260 °C (±1 °C) |
| Focusing Trap Flash Heating Rate | >3000 °C/min |
| Purge Flow Rate | 0–600 mL/min (adjustable) |
| Simulated Sampling Flow | 100 mL/min |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Model | CZ-100A |
| Pyrolyzer Type | Resistive Filament (Platinum Wire or Ribbon) |
| Maximum Filament Temperature | 1400 °C |
| Temperature Ramp Stages | Up to 10-step programmable heating |
| Display | Color Touchscreen with Parameter Input & Storage (12 methods) |
| Power Loss Protection | Yes |
| Integrated Gas Path | Yes, compatible with external GC/MS without modification |
| Sample Introduction | Quartz tube (wire type) or coated probe (ribbon type) |
| Onboard Probe Cleaning Mode | High-temperature bake-out at 1400 °C |
| Mounting | Direct installation onto GC inlet via dedicated bracket |
| Interface | Synchronized trigger output for real-time GC/MS control |
| Compliance | Designed for ASTM D7213, ISO 11348, and USP <621> pyrolysis-GC applications |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | JK-0A |
| Pricing | Upon Request |
| Sample Zone Temp Range | Ambient to 400 °C (1 °C increment) |
| Valve & Transfer Line Temp Range | Ambient to 160 °C (1 °C increment) |
| Temp Control Accuracy | < ±0.5 °C |
| Desorption Recovery | >85% (compound-dependent) |
| Purge Flow Rate | 0–20 mL/min (continuously adjustable) |
| Dimensions | 360 × 170 × 390 mm |
| Weight | ~10 kg |