| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JK-LC |
| Price Range | USD 700–1,400 (FOB) |
| Temperature Control | Heating-only (no refrigeration) |
| Temperature Range | Ambient to 100 °C |
| Temperature Stability | ±0.1 °C |
| Temperature Uniformity | ±0.1 °C (at 50 °C) |
| Repeatability | ±0.1 °C |
| Chamber Dimensions | 350 mm × 45 mm × 40 mm (L × W × H) |
| Power Supply | 220 V AC, 50 Hz |
| Display | Dual-line LED |
| Control Interface | Touch-sensitive membrane switches |
| Safety Features | Over-temperature alarm + auto cut-off |
| Mounting | Magnetic lid retention |
| Viewing Window | Integrated tempered glass viewport |
| Column Capacity | 1–2 standard HPLC columns (up to 250 mm length) |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Category | Domestic |
| Model | PTC-30A |
| Sample Capacity | 30-position |
| Instrument Type | Water-and-Soil Integrated Purge and Trap System |
| Dehumidification Trap Temp Range | Ambient to 240 °C (1 °C increments) |
| Valve & Transfer Line Temp Range | Ambient to 220 °C (1 °C increments) |
| Trap Cooling/Desorption Temp Range | −30 °C to 400 °C (electronic cooling, 1 °C increments) |
| Sample Heating Temp Range | Ambient to 240 °C (1 °C increments) |
| Purge Flow Rate | 0–100 mL/min (adjustable) |
| Back-Flush Flow Rate | 0–100 mL/min (adjustable) |
| Sample Vial | 40 mL |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Model | TP-6000 |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Sample Vial Heating Range | Ambient to 450 °C |
| Valve & Transfer Line Temperature Control Range | Ambient to 210 °C (1 °C increment) |
| Quantitative Loop Volume | 1 mL |
| Vial Capacity | 9 positions |
| Vial Size | 10 mL |
| Temperature Stability | < ±0.5 °C |
| RSD for Peak Area | ≤1.5% (under optimized conditions) |
| Equilibration/Injection/Clean Time Range | 0–60 min (user-programmable) |
| Brand | 4Labplus |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | LAB-T100mini |
| Sample Capacity | 10 positions |
| Heating Rate | ≤3 min to 300°C |
| Operating Flow Control | High-pressure, low-flow precision gas regulation |
| Gas Path Isolation | Independent channel design |
| Base Material | Low-outgassing stainless steel and inert ceramics |
| Audible Alert | Integrated buzzer with timer completion signal |
| Footprint | Compact benchtop (W×D×H ≈ 260×320×280 mm) |
| Brand | 4Labplus |
|---|---|
| Origin | Guangdong, China |
| Manufacturer | Yes |
| Country of Origin | China |
| Model | LAB-T200mini |
| Sample Capacity | 20 positions |
| Heating Rate | ≤3 min to 300°C |
| Safety Features | Intelligent Carrier Gas Pressure Detection with Auto-Shutoff |
| Gas Flow Control | Patented Independent Channel Design |
| Operating Mode | Flexible Batch Size (1–20 tubes) |
| Construction Materials | Low-Background, Inert Components |
| Audible Alert | Integrated Buzzer Timer |
| Dimensions | Compact Benchtop Form Factor |
| Compliance | Designed for ISO/IEC 17025-aligned laboratory workflows |
| Brand | 4Labplus |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM Manufacturer |
| Model | LAB-T210P |
| Sample Capacity | 20 positions |
| Power Supply | Low-voltage DC |
| Max Temperature | 300°C |
| Ramp Time to 300°C | <3 min |
| Gas Pressure Detection | Intelligent low-pressure cutoff |
| Flow Control | Independent channel regulation, high-pressure/low-flow architecture |
| Standby Mode | Gas-saving idle state |
| Material | Ultra-low-background inert construction |
| Alert System | Audible buzzer timer notification |
| Form Factor | Benchtop, fume-hood compatible |
| Brand | LABA (Tianjin) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | 2000 |
| Instrument Type | UV-Vis Absorbance Detector |
| Wavelength Range | 190–900 nm |
| Optical Design | Dual-Beam |
| Light Source | Deuterium Lamp |
| Spectral Scanning Capability | Yes |
| Flow Cell Options | Stainless Steel & Kel-F (Chemically Inert, Biocompatible) |
| Programmable Peak Detection | Yes |
| Baseline Correction Algorithm | Adaptive |
| Lamp Access | Side-Mounted for Quick Replacement |
| Flow Cell Access | Side-Mounted for Tool-Free Exchange |
| Brand | LABA (Tianjin LABA) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Fract R1 |
| Instrument Type | Gas-Phase-Compatible Fraction Collector |
| Control Modes | Time-Based, Drop-Count-Based, Peak-Triggered (UV/Analog Signal Input) |
| Collection Capacity | Up to 96 Tubes (Standard Rack Configuration) |
| Dimensions | 320 × 300 × 280 mm |
| Weight | 8.2 kg |
| Brand | LABA |
|---|---|
| Origin | USA |
| Model | OV3000 |
| Temperature Control | Active Cooling & Heating |
| Capacity | ≥6 analytical columns (e.g., 4.6 × 250 mm) or ≥2 semi-preparative columns (up to 300 mm length) |
| Safety | Leak-activated automatic power cutoff |
| Control System | Dual 3-digit microprocessor-based PID controller with independent setpoint and display |
| Construction | Insulated stainless-steel chamber with optimized thermal conduction architecture |
| Compliance | Designed for GLP-compliant chromatography workflows |
| Brand | LABA (Tianjin) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | PCR2 |
| Temperature Range | Ambient to 150 °C |
| Derivatization Reagent Flow Rate | 0.01–5.00 mL/min |
| Reaction Coil Material | PEEK |
| Brand | LABA (Tianjin LABA) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | PCR 3 |
| Temperature Range | Ambient to 200 °C |
| Derivatization Reagent Flow Rate | 0.001–10.000 mL/min |
| Reaction Coil Material | Stainless Steel |
| Brand | LABA |
|---|---|
| Origin | USA |
| Model | PCR3 |
| Temperature Range | Ambient to 200 °C |
| Derivatization Reagent Flow Rate | 0.001–10 mL/min |
| Reaction Coil Material | PEEK |
| Compliance | Fully compatible with all HPLC platforms (Agilent, Waters, Shimadzu, Thermo Fisher, etc.) |
| Control Interface | Dual-mode (front-panel keypad + PC via USB/RS-232) |
| Safety Features | Overpressure shutdown, leak detection, thermal overheat protection |
| Fluidic Architecture | Chemically inert, self-cleaning pump head, pressurized reagent reservoirs with N₂ blanket control |
| Reactor Options | Interchangeable, customizable volume reaction coils (standard: 0.5–5 mL internal volume) |
| Brand | Laba (Tianjin Laba Co., Ltd.) |
|---|---|
| Origin | USA |
| Model | PCR3 |
| Temperature Range | Ambient to 200 °C |
| Derivatization Reagent Flow Rate | 0.001–10 mL/min |
| Reaction Coil Material | PEEK |
| Pump Type | High-Precision Syringe-Type Piston Pump |
| Control Interface | Front-panel Keypad + PC via USB/RS-232 |
| Safety Features | Overpressure Shutdown, Leak Detection, Thermal Overload Protection |
| Reagent Delivery | Pressurized N₂-driven with Adjustable Flow Regulation and Splitting |
| Reactor Options | Modular, Customizable Volume (Standard: 0.5–5 mL), Multi-directional Mixing Geometry |
| Fluidic Path | Fully Chemically Inert (PEEK, Sapphire, Hastelloy C-276) |
| Cleaning | Integrated On-Line Solvent Flush Routine |
| Compliance | Designed for GLP/GMP environments |
| Brand | LABA (Tianjin LABA) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | PR-2 |
| Temperature Range | Ambient to 200 °C |
| Derivatization Reagent Flow Rate | 0.001–10.000 mL/min |
| Reaction Coil Material | PEEK |
| Brand | LABA |
|---|---|
| Model | SeriesII |
| Type | Isocratic Pump |
| Flow Rate Range | Up to 40 mL/min |
| Drive Mechanism | Microstepping Stepper Motor |
| Control Interface | LED Display + Keypad |
| Warranty | 3 Years |
| Origin | USA |
| Category | HPLC Accessory / Isocratic Solvent Delivery System |
| Compliance | Designed for GLP-compliant laboratories, compatible with ASTM D5279 and ISO 13877 workflows for liquid chromatographic method validation |
| Brand | Laballiance |
|---|---|
| Origin | USA |
| Model | 201/525 |
| Wavelength Range | 190–380 nm (Model 201), 190–365 nm (Model 525) + Tungsten Lamp 366–800 nm |
| Dual-Wavelength Capability | 190–450 nm or 366–800 nm |
| Spectral Bandwidth | 6 nm |
| Wavelength Accuracy | ±1.0 nm |
| Wavelength Repeatability | ±0.1 nm |
| Noise | < ±1.0 × 10⁻⁵ AU @ 254 nm (single wavelength) |
| Absorbance Range | 0.0005–3.0 AUFS |
| Absorbance Linearity | >99% to 2.0 AU @ 254 nm |
| Optical Design | Concave holographic grating monochromator, dual-beam with fiber-optic beam splitter |
| Analog Output | Dual-channel, full-scale selectable |
| Power Supply | 220 V, 50/60 Hz |
| Dimensions | 30.5 cm W × 40.6 cm D × 17.8 cm H (12″ × 16″ × 7″) |
| Weight | 14 kg (31 lb) |
| Brand | Laballiance |
|---|---|
| Origin | USA |
| Model | 305 |
| Optical Design | Dual monochromator with concave holographic diffraction gratings |
| Excitation/Emission Wavelength Range | 200–600 nm (Ex & Em) |
| Wavelength Accuracy | ±2 nm @ 248 nm Ex / 398 nm Em |
| Wavelength Precision | <0.5 nm |
| Spectral Bandwidth Options | 8, 20, or 30 nm |
| Light Source | Pulsed xenon lamp (20 Hz or 100 Hz selectable) |
| Flow Cell | Biocompatible quartz/Teflon/Kalrez/PEEK, 8 µL detection volume, max pressure 200 psi (14 bar) |
| Sensitivity | 2 µg/L anthracene in methanol, S/N > 1500 @ 284 nm Ex / 398 nm Em |
| Scan Speed | Up to 100 steps/sec |
| step resolution | 2, 4, 8, 16, or 32 nm |
| Stored Spectra Capacity | Up to 60 emission spectra |
| Dynamic Range | 0.01–500 FUFS (Fluorescence Units Full Scale) with 15 programmable gain levels |
| Analog Output | 20-bit D/A converter, full-scale range adjustable |
| Detection Modes | Fluorescence, phosphorescence, chemiluminescence |
| Method Storage | 4 user-defined method files, each supporting up to 10 time-programmed wavelength transitions, with inter-file linking capability |
| Operating Environment | 10–40 °C, 5–95% RH (non-condensing) |
| Dimensions & Weight | 7" H × 12" W × 16" D, 24 lbs (11 kg) |
| Power Supply | 220 VAC, 50/60 Hz, max 2 A |
| Brand | Laballiance |
|---|---|
| Origin | USA |
| Model | 6000 |
| Wavelength Range | 190–800 nm |
| Optical Path Length | 5 cm |
| Flow Cell Volume | 12 µL (10 mm path) |
| Noise | ±3 × 10⁻⁶ AU/cm |
| Drift | 1 × 10⁻³ AU/hr |
| Linearity | >2.0 AU |
| Scan Rate | ≤20 Hz |
| Spectral Resolution | 1.2 nm |
| Wavelength Accuracy | ±1 nm |
| Light Source | Deuterium + Tungsten-Halogen Lamps |
| A/D Converter | 20-bit |
| Data Acquisition Rate | Configurable up to 20 Hz |
| Beam Delivery | Stacked Optical Fiber Optics |
| Compliance | ASTM E275, USP <857>, ISO/IEC 17025-aligned verification protocols |
| Brand | Laballiance |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Laballiance PCDS |
| Price | Upon Request |
| Pump Flow Rate | 0.01–2.5 mL/min |
| Maximum Pressure | 2500 psi |
| Flow Precision | ±0.5% RSD |
| Flow Accuracy | ±2% |
| Flow Path Material | Full PEEK |
| Temperature Control Range | Ambient +10 °C to 150 °C |
| Temperature Accuracy | ±2 °C |
| Temperature Repeatability | ±1 °C |
| Safety Cutoff Temperature | 160 °C |
| Reactor Volume Accuracy | ±5% |
| Warm-up Time to 150 °C | ≤30 min |
| Communication Interface | RS232 |
| Brand | GRACE |
|---|---|
| Origin | Germany |
| Model | RI 2000 |
| Detection Principle | Differential Refractometry |
| Refractive Index Range | 1.00–1.75 |
| Flow Rate Range | 0.2–3.0 mL/min |
| Linear Range | 80 × 10⁻⁵ RIU |
| Noise Level | 5 × 10⁻¹⁰ RIU |
| Auto-Zero Range | 40 × 10⁻⁵ RIU |
| Auto-Zero Resolution | 5 × 10⁻¹⁰ RIU |
| Integrator Output | ±1 V |
| Recorder Output | ±10 V |
| Analog Input Range | −5 to +5 V DC |
| Temperature Setpoints | Ambient, 35 °C, or 55 °C (microprocessor-controlled) |
| Flow Cell Volume | 9 µL |
| Maximum Flow Cell Pressure | 6 kg/cm² |
| Brand | Labman (formerly LABA Tianjin) |
|---|---|
| Model | LB8120 |
| Detector Type | Ultraviolet-Visible Absorbance Detector |
| Wavelength Range | 190–900 nm |
| Optical Design | Dual-Beam with Shielded Optics |
| Light Source | Deuterium Lamp |
| Grating Type | Holographic Concave Grating |
| Detection Mode | Programmable Dual-Wavelength Simultaneous Monitoring |
| Spectral Acquisition | Continuous Rapid Scanning |
| Lamp Control | Fully Automated Start/Stop with Warm-up Optimization |
| Origin | USA-assembled with global supply chain integration |
| Compliance | Designed to support GLP/GMP workflows and ASTM E260, ISO 17025-aligned operation |
| Brand | Labomatic |
|---|---|
| Origin | Switzerland |
| Type | Dynamic Axial Compression (DAC) System |
| Construction Material | Borosilicate Glass |
| Max Operating Pressure | 65 bar (940 psi) |
| Piston Adjustment Range | 150 mm |
| Column Diameter Options | 8 sizes (28–300 mm) |
| Column Length Options | 3 standard lengths |
| Seal Design | Spring-loaded elastomeric seals |
| Sample Distribution | Optimized distributor for improved packing reproducibility |
| Compatibility | Biocompatible inert materials |
| Modular Conduit System | Shared tubing manifold for multi-column operation |
| Packing Tool Kits | Available for all AMC column diameters |
| Regulatory Context | Designed for GLP-compliant preparative chromatography workflows |
| Brand | Labomatic |
|---|---|
| Origin | Switzerland |
| Model | LH3000 |
| Instrument Type | HPLC Autosampler |
| X-axis Travel Range | 160–2800 mm (customizable) |
| Y-axis Travel Range | 70–670 mm (single arm) |
| Z-axis Height Range | 130–780 mm (fixed base height), max vertical stroke: 400 mm |
| Compliance | Designed for GLP/GMP environments |
| Brand | LABORAT |
|---|---|
| Model | LYM-1061 |
| Derivatization Volume Options | 0.50 / 0.75 / 1.00 / 1.50 mL |
| Reaction Loop Material | Polyetheretherketone (PEEK), Polytetrafluoroethylene (PTFE), 316L Stainless Steel |
| Operating Temperature Range | Ambient + 5.0 °C to 150.0 °C |
| Flow Rate Control Range | 0.001–4.999 mL/min |
| Pump Fluid Path | Full-PEEK chemically inert construction |
| Reaction Coil Layout | 1.2 cm annular configuration |
| Real-time Instrument Status Monitoring | Yes |
| Optional Piston Wash | 1 mL/min |
| Brand | Laborator |
|---|---|
| Model | LYR-1090 |
| Light Source Wavelength | 253.7 nm |
| Derivatization Cell Volume | 1 mL |
| UV Lamp Lifetime | 7,000 h |
| Temperature Monitoring | Yes |
| UV Intensity Monitoring | Yes |
| Compliance | Designed for USP <621>, ISO/IEC 17025, and GLP-aligned workflows |
| Software Audit Trail | Not included (available in LYR-2094 variant) |
| Origin | China |
| Brand | LabTech |
|---|---|
| Origin | Switzerland |
| Manufacturer | LabTech Instruments AG |
| Product Type | Multifunctional Autosampler for GC/GC-MS/LC/LC-MS |
| Core Techniques | Purge-and-Trap, Static/Dynamic Headspace, Solid-Phase Microextraction (SPME), Thermal Desorption, Pyrolysis, Large-Volume Injection, Gel Permeation Chromatography (GPC) Cleanup, µSPE, Vortex Mixing, Liquid-Liquid Extraction, Derivatization, Cap Piercing, Pipetting |
| Platform Compatibility | GC, GC-MS, LC, LC-MS/MS (vendor-neutral interface) |
| Structural Design | Modular, Rack-Mounted, Instrument-Integrated Platform |
| Configurable Footprint | 534 mm to 1600 mm linear rail length |
| Automation Level | Fully Unattended Operation with Inter-Module Tool Exchange |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | CDS 5200 |
| Price | Upon Request |
| Pyrolysis Temperature Range | Ambient to 1400 °C (adjustable in 0.1 °C increments) |
| Temperature Accuracy | ±0.1 °C |
| Maximum Pressure Rating | 500 PSI (3400 kPa) |
| Heating Rate (Pulse Mode) | 10–20,000 °C/sec |
| Heating Rate (Programmed Mode) | 0.01–999.9 °C/sec or 0.01–999.9 °C/min |
| Programmable Steps per Run | Up to 8 steps with independent GC trigger per step |
| Transfer Line Max Temp | 350 °C |
| Interface Temp | ≥350 °C |
| Sample Path Material | Inert (e.g., SilcoNert®-treated stainless steel or fused silica) |
| Optional In-line Cold Trap | Integrated cryo-focusing with thermal desorption |
| Atmosphere Control | N₂, air, O₂, He, or custom gas (via external mass flow controller) |
| Catalytic Reactor | 3″ × 1/4″ OD 316 stainless steel, rated to 800 °C, user-replaceable catalyst bed |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | PR600 |
| Pricing | Upon Request |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-made) |
| Model | PY1000 Pyrolyzer |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LB8110 Plus |
| Instrument Type | Quaternary Pump (Note: “Six-solvent pump” in source is inconsistent with “quaternary” specification |
| Price Range | USD 7,000 – 14,000 (converted at ~¥7.2/USD) |