Chromatography Accessories
Filter
Showing 541–570 of 1016 results
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | ATDS-3600A |
| Price Range | USD 14,000 – 42,000 |
| Instrument Type | Two-Stage Thermal Desorber / Thermal Desorption Unit |
| Desorption Temperature Range | −30 °C to 400 °C |
| Cold Trap Temperature Range | −30 °C to 50 °C |
| Desorption Recovery Rate | >95% |
| Sample Capacity | 20 positions |
| Temperature Control Accuracy | <±0.1 °C |
| Heating Ramp Rate | >2000 °C/min |
| Carrier Gas Flow | 0–400 mL/min (continuously adjustable) |
| Dimensions | 450 × 360 × 510 mm |
| Brand | Beijing Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Model | ADHS-8890A |
| Sample Capacity | 20 positions |
| Injection Precision | RSD < 2.5% (GC-dependent) |
| Trap Temperature Range | Ambient to 380 °C |
| Purge Vial Heating Range | Ambient to 250 °C |
| Chilled Vial Temperature Range | 4–10 °C |
| Cold Trap Temperature Range | Ambient to −40 °C |
| Water Removal Trap Range | Ambient to −30 °C |
| Desorption Ramp Rate | >250 °C/min |
| Carrier Gas Pressure Regulation | 0–0.4 MPa |
| Purge Flow Rate | 0–500 mL/min |
| Tubing & Line Heating Range | Ambient to 250 °C |
| Power Consumption | <1000 VA |
| Dimensions (H×W×D) | 500×400×650 mm |
| Weight | ~40 kg |
| Brand | Beijing Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | ADHS-8890B |
| Instrument Type | Water & Soil Integrated Purge-and-Trap System |
| Sample Tray Capacity | 20 positions |
| Injection Precision | RSD < 10% |
| Trap Temperature Range | Ambient to 380 °C |
| Purge Vial Heating Range | Ambient to 250 °C |
| Vial Cooling Range | 4–10 °C |
| Cold Trap (Desorption) Range | Ambient to –40 °C |
| Water Removal Trap Range | Ambient to –30 °C |
| Desorption Ramp Rate | >250 °C/min (low-voltage safe design) |
| Transfer Line & Valve Block Temp | Ambient to 250 °C |
| Carrier Gas Pressure Regulation | 0–0.4 MPa |
| Purge Flow Rate | 0–500 mL/min |
| Trap Tube Materials | Stainless steel / Quartz / Fused silica capillary (customizable) |
| Adsorbent Options | Custom-fill available |
| Programmable External Events | 7 channels |
| Timing Resolution | 0.1–99 min (timing accuracy <0.1%) |
| Pneumatic Actuation Pressure | <0.4 MPa |
| System Pressure Rating | >0.4 MPa |
| Analytical Repeatability (GC-coupled) | RSD < 2.5% |
| Power Consumption | <1000 VA |
| Trigger Signal Latency | <2 s |
| Dimensions (H×W×D) | 500 × 400 × 650 mm |
| Weight | ~40 kg |
| Brand | Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Model | AHS-20 |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Sample Vial Capacity | 20 positions |
| Vial Sizes Supported | 10 mL and 20 mL |
| Oven Temperature Range | Ambient to 380 °C (±0.5 °C accuracy, 1 °C increment) |
| Valve & Transfer Line Temperature Range | Ambient to 260 °C (±1 °C accuracy, 1 °C increment) |
| Loop Volume | 20 mL standard |
| Temperature Control Stability | ±0.5 °C |
| Brand | Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Model | AHS-50 |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automated |
| Sample Tray Capacity | 50 positions |
| Vial Size Compatibility | 10 mL and 20 mL standard crimp-top vials |
| Oven Temperature Range | Ambient to 380 °C (±0.5 °C accuracy, 1 °C increment) |
| Valve & Transfer Line Temperature Range | Ambient to 260 °C (±1 °C accuracy, 1 °C increment) |
| Quantitative Loop Volume | 1 mL |
| External Event Control Channels | 15 |
| Timing Resolution | 0.1–99 minutes (timing error <0.1%) |
| Pneumatic Actuation Pressure | <0.4 MPa (adjustable) |
| System Pressure Rating | >0.4 MPa |
| Heated Incubation Zones | 4 independent zones |
| Repeatability | RSD <1% (dependent on GC system performance and operator technique) |
| Power Requirement | <1000 VA |
| Trigger Signal Output Latency | <2 s |
| Dimensions (H×W×D) | 580 × 564 × 666 mm |
| Net Weight | ~40 kg |
| Brand | Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Model | AHS-6890S |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Semi-Automatic |
| Sample Vial Capacity | 9 positions |
| Vial Size | 20 mL (customizable: 10 mL, 50 mL) |
| Oven Temperature Range | Ambient to 350 °C (1 °C increment) |
| Valve & Transfer Line Temperature Range | Ambient to 180 °C (1 °C increment) |
| Temperature Accuracy | < ±0.5 °C |
| Pressure Control Range | 0–0.2 MPa (up to 0.7 MPa optional) |
| Pressure Monitoring | Digital display, 0–0.2 MPa |
| RSD for Repeatability | < 1% (GC-dependent) |
| Dimensions | 260 × 360 × 420 mm |
| Weight | ~15 kg |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Operating Environment | 10–40 °C, RH < 85% |
| Brand | Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Model | AHS-8890 |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Sample Tray Capacity | 20 positions |
| Vial Size | 20 mL (customizable: 10 mL, 50 mL) |
| Oven Temperature Range | Ambient to 200 °C (1 °C increment) |
| Valve & Transfer Line Temperature Range | Ambient to 180 °C / Ambient to 150 °C (1 °C increment) |
| Temperature Control Accuracy | < ±0.5 °C |
| Temperature Uniformity (Gradient) | < ±0.5 °C |
| Pressurization Range | 0–0.2 MPa (0–0.7 MPa optional) |
| Pressure Monitoring | Digital display, 0–0.2 MPa |
| RSD for Repeatability | < 1% (GC-dependent) |
| Power Supply | AC 220 V ±10%, 50 Hz ±0.5 Hz |
| Operating Environment | 10–40 °C, RH < 85% |
| Dimensions (W×D×H) | 570 × 330 × 265 mm |
| Weight | ~25 kg |
| Brand | Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Model | ATDS-3430 |
| Instrument Type | Single-Stage Thermal Desorber |
| Automation Level | Semi-Automatic |
| Desorption Temperature Range | Ambient to 380 °C (±0.5 °C accuracy, 1 °C increment) |
| Valve Temperature Range | Ambient to 260 °C (±1 °C) |
| Transfer Line Temperature Range | Ambient to 260 °C (±1 °C) |
| Cold Trap Temperature | Ambient |
| Temperature Stability | < ±1 °C |
| Desorption Recovery | >98% (toluene, 0.1 µL, 10:1 split ratio) |
| Peak Width (FWHM) | <3 s |
| Sample Capacity | 1 tube per run |
| Carrier Gas Flow | 0–100 mL/min (adjustable, with flow indicator) |
| Pneumatic Actuation Pressure | <0.4 MPa (adjustable) |
| System Pressure Rating | >0.4 MPa |
| Timing Resolution | 0.1–99 min (timing error <0.1%) |
| Programmable External Events | 15 |
| Power Consumption | <1000 VA |
| Dimensions (H×W×D) | 470×500×380 mm |
| Weight | ~35 kg |
| Brand | Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Model | ATDS-3430S |
| Automation Level | Fully Automated |
| Desorption Temperature Range | Ambient to 380 °C (±0.5 °C accuracy, 1 °C increment) |
| Valve Temperature Range | Ambient to 260 °C (±1 °C) |
| Transfer Line Temperature Range | Ambient to 260 °C (±1 °C) |
| Cold Trap Temperature | Ambient |
| Temperature Stability | < ±1 °C |
| Desorption Recovery Rate | >98% (toluene, 0.1 µL, 10:1 split ratio) |
| Peak Width (FWHM) | <3 s |
| Sample Capacity | 30 tubes |
| Programmable Events | Up to 15 |
| Event Timing Range | 0.1–99 min (<0.1% timing error) |
| Carrier Gas Flow | 0–100 mL/min (adjustable, digital indication) |
| Pneumatic Actuation Pressure | <0.4 MPa (adjustable) |
| System Pressure Rating | >0.4 MPa |
| RSD | <2.5% (GC-dependent) |
| Power Consumption | <1000 VA |
| Trigger Signal Output Delay | <2 s |
| Dimensions (H×W×D) | 470×490×450 mm |
| Weight | ~40 kg |
| Brand | Beijing Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Model | ATDS-3440 |
| Instrument Type | Two-Stage Thermal Desorber |
| Automation Level | Semi-Automatic |
| Primary Desorption Temp Range | Ambient to 380 °C (±0.5 °C accuracy, 1 °C increment) |
| Secondary Desorption Temp Range | Ambient to 380 °C (±0.5 °C accuracy, 1 °C increment, >3000 °C/min ramp rate) |
| Cold Trap Temp Range | Ambient to −40 °C (±1 °C accuracy, 1 °C increment) |
| Valve & Transfer Line Temp Range | Ambient to 260 °C (±1 °C accuracy, 1 °C increment) |
| Sample Capacity | 1 tube per run |
| Desorption Recovery | >98% (toluene, 0.1 µL, 10:1 split) |
| Peak Width (FWHM) | <3 s |
| RSD | <2.5% (GC-dependent) |
| Carrier Gas Flow | 0–100 mL/min (adjustable, visual indicator) |
| Pneumatic Actuation Pressure | <0.4 MPa (adjustable) |
| System Pressure Rating | >0.4 MPa |
| External Event Control | 15 programmable events |
| Event Timing Range | 0.1–99 min (<0.1% timing error) |
| Tube Materials | Stainless steel, quartz glass, fused silica capillary (optional) |
| Power Consumption | <1000 VA |
| GC Trigger Latency | <2 s |
| Dimensions (H×W×D) | 470×500×380 mm |
| Weight | ~35 kg |
| Brand | Beijing Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Model | ATDS-3440S |
| Automation Level | Fully Automated |
| Primary Desorption Temp Range | Ambient to 380°C, ±0.5°C accuracy, 1°C increment |
| Secondary Desorption Temp Range | Ambient to 380°C, ±0.5°C accuracy, 1°C increment, >3000°C/min ramp rate |
| Cold Trap Temp Range | Ambient to –40°C (ambient-dependent), ±1°C accuracy, 1°C increment |
| Valve & Transfer Line Temp Range | Ambient to 260°C, ±1°C accuracy, 1°C increment |
| Sample Capacity | 30 tubes |
| Desorption Recovery | >98% (toluene, 0.1 µL, 10:1 split) |
| Peak Width (FWHM) | <3 s |
| RSD | <2.5% (GC-dependent) |
| Power Consumption | <1000 VA |
| Dimensions (H×W×D) | 470 × 490 × 450 mm |
| Weight | ~40 kg |
| Brand | Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Model | ATDS-3440S-II |
| Automation Level | Fully Automated |
| Primary Desorption Temp Range | Ambient to 380°C (±0.5°C accuracy, 1°C increment) |
| Secondary Desorption Temp Range | Ambient to 380°C (±0.5°C accuracy, 1°C increment, >3000°C/min ramp rate) |
| Cold Trap Temp Range | Ambient to –40°C (±1°C accuracy, 1°C increment) |
| Valve & Transfer Line Temp Range | Ambient to 260°C (±1°C accuracy, 1°C increment) |
| Sample Capacity | 40 tubes |
| Desorption Recovery | >98% (toluene, 0.1 µL, 10:1 split) |
| Peak Width (FWHM) | <3 s |
| RSD | <2.5% (system-dependent, GC and operator performance included) |
| Power Consumption | <1000 VA |
| Dimensions (H×W×D) | 470 × 490 × 450 mm |
| Weight | ~40 kg |
| Brand | Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Model | ATDS-4133 |
| Automation Level | Fully Automated |
| Primary Desorption Temp Range | Ambient to 380°C (±0.5°C accuracy, 1°C increment) |
| Secondary Desorption Temp Range | Ambient to 380°C (±0.5°C accuracy, 1°C increment, >3000°C/min ramp rate) |
| Cold Trap Temp Range | Ambient to −40°C (±1°C accuracy, 1°C increment) |
| Valve & Transfer Line Temp Range | Ambient to 260°C (±1°C accuracy) |
| Sample Pathway Temp Range | Ambient to 200°C (±1°C accuracy) |
| Sample Capacity | 50 tubes |
| Desorption Recovery | >98% (toluene, 0.1 µL, 10:1 split ratio) |
| Peak Width (FWHM) | <3 s |
| RSD | <2.5% |
| Tube Material | Stainless steel |
| Trap Options | Stainless steel, quartz glass, or fused silica capillary |
| Carrier Gas Flow | 0–100 mL/min (adjustable with flow indicator) |
| Pneumatic Actuation Pressure | <0.4 MPa (adjustable) |
| System Pressure Rating | >0.4 MPa |
| External Event Control | 15 programmable events |
| Event Timing Range | 0.1–99 min (<0.1% timing error) |
| Power Consumption | <1000 VA |
| GC Trigger Latency | <2 s |
| Dimensions (H×W×D) | 500 × 485 × 650 mm |
| Weight | ~45 kg |
| Brand | Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Model | ATDS-51 |
| Instrument Type | Dual-stage thermal desorber |
| Automation Level | Fully automated |
| Primary Desorption Temperature Range | 50–380 °C |
| Secondary Desorption Temperature Range | 150–380 °C |
| Valve & Transfer Line Temperature Range | Ambient to 260 °C |
| Cold Trap Temperature Range | Ambient to −40 °C |
| Temperature Control Accuracy | < ±0.1 °C |
| Peak Width (FWHM) | < 3 s |
| Desorption Efficiency | >98% (toluene, 0.1 µL, 10:1 split ratio) |
| Sample Capacity | 51 positions |
| Compliance | Designed for ASTM D6196, ISO 16017-1, USP <621>, and EPA TO-17 workflows |
| Brand | Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Model | PTC-100 |
| Sample Capacity | 100-position carousel |
| Injection Precision | RSD < 2.5% (GC-dependent) |
| Trap Temperature Range | Ambient to 380 °C |
| Purge Heating Temperature | Ambient to 250 °C |
| Sample Chilling Temperature | 4–10 °C |
| Cold Trap Temperature | Ambient to −40 °C |
| Water Removal Trap Temperature | Ambient to −30 °C |
| Desorption Ramp Rate | >2000 °C/min (low-voltage controlled) |
| Purge Flow Control | 0–100 mL/min, adjustable with digital readout |
| Carrier Gas Pressure Regulation | 0–0.4 MPa |
| Programmable External Events | 15 independent time-controlled functions (0.1–99 min, timing accuracy <0.1%) |
| Sample Vial Format | Standard 40 mL vials |
| System Dimensions | 580 × 640 × 850 mm (H×W×D) |
| Weight | ~50 kg |
| Power Consumption | <1000 VA |
| Interlock Signal Latency | <2 s |
| Brand | Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Model | PTC-50 |
| Sample Capacity | 50 positions |
| Injection Precision | RSD < 10% |
| Trap Temperature Range | Ambient to 380 °C |
| Purge Vial Heating Range | Ambient to 250 °C |
| Vial Cooling Range | 4–10 °C |
| Cold Trap Temperature Range | Ambient to −40 °C |
| Water Removal Trap Range | Ambient to −30 °C |
| Desorption Rate | >2000 °C/min |
| Water Trap Desorption Range | Ambient to 150 °C |
| Transfer Line Temperature | Ambient to 250 °C |
| Carrier Gas Pressure Regulation | 0–0.4 MPa |
| Purge Flow Rate | 0–100 mL/min |
| Trap Materials | Stainless steel / quartz / fused silica capillary (configurable) |
| Programmable External Events | 15 |
| Timing Resolution | 0.1–99 min (accuracy <0.1%) |
| Power Consumption | <1000 VA |
| Dimensions (H×W×D) | 580 × 640 × 850 mm |
| Weight | ~50 kg |
| Brand | Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Model | TDS-3410 |
| Temperature Range | Ambient to 400 °C |
| Gas Flow Rate | 10–250 mL/min |
| Tube Capacity | 12 tubes |
| Temperature Control Resolution | 1 °C |
| Temperature Accuracy | ±0.5% of setpoint |
| Timer Range | 0–655 min |
| Power Consumption | <500 W |
| Dimensions (W×D×H) | 170×390×400 mm |
| Weight | ~8 kg |
| Brand | HUIFEN Instrument |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | AGS-30(60) |
| Instrument Type | Gas Chromatography Autosampler |
| Sampling Modes | Bag, Syringe, and Loop Injection (Optional) |
| Calibration | Fully Automated Multi-Point Dilution Calibration |
| Cleaning | Integrated Pre- and Post-Injection Tubing & Loop Purge |
| Control Interface | 7-inch Capacitive Touchscreen + Optional PC Remote Control (Synchronized GUI) |
| Gas Dilution | Programmable Proportional Mixing of Standard or Sample Gases |
| Compliance | Designed for ISO/IEC 17025-aligned QC labs and GLP-compliant environmental & industrial gas analysis workflows |
| Brand | HUIFEN Instrument |
|---|---|
| Origin | Shandong, China |
| Model | AHS-16 |
| Type | Dynamic Headspace Sampler |
| Automation Level | Fully Automated |
| Sample Vial Capacity | 16 positions |
| Touchscreen Interface | 7-inch capacitive LCD |
| Valve Type | Precision high-temperature 6-port rotary valve |
| Sample Loop Material | Passivated 316 stainless steel |
| Sample Path Heating | Independent heated transfer line (up to 220 °C) |
| Carrier Gas Control | High-accuracy pressure and flow regulators |
| Adsorbent Trap Cleaning Function | Integrated purge cycle |
| Compliance | Designed for compatibility with ISO 17025-accredited labs and GLP/GMP workflows |
| Brand | HUIFEN |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ALS-24 |
| Instrument Type | Dynamic Headspace Autosampler |
| Automation Level | Fully Automatic |
| Sample Capacity | 24-position |
| Solvent Options | Up to 4 programmable rinse solvents (pre- and post-injection) |
| Thermal Independence | Injection mechanism operates independently of GC inlet temperature |
| Brand | HUIFEN Instrument |
|---|---|
| Origin | Shandong, China |
| Model | HS-06 |
| Instrument Type | Dynamic Headspace Sampler |
| Automation Level | Semi-Automatic |
| Vial Heating Range | Ambient +1°C to 200°C (1°C increments) |
| Valve & Transfer Line Heating Range | Ambient +1°C to 200°C (1°C increments) |
| Quantitative Loop Volume | 1 mL |
| Vial Capacity | 9 positions |
| Vial Size | 20 mL |
| Temperature Control Accuracy | < ±0.2°C |
| Pressure Control Range | 0–0.4 MPa (continuously adjustable) |
| Method Storage | 20 user-programmable methods |
| Timing Precision | Programmable 3-event, 10-segment time sequence |
| Reproducibility | RSD ≤ 1.0% (200 ppm ethanol in water) |
| Purge Flow & Duration | Adjustable for backflush cleaning |
| Brand | Huifen Instruments |
|---|---|
| Origin | Shandong, China |
| Model | TD-06 |
| Type | Single-Stage Thermal Desorber |
| Gas Path Material | Passivated 316 Stainless Steel Tubing |
| Valve System | Precision Motorized 6-Port High-Temperature Valve (Low Dead Volume) |
| Sample Tube Handling | Manual Loading with Optimized Sealing Design |
| Tube Cleaning Function | Integrated Purge Cycle for Cross-Contamination Prevention |
| Temperature Control | Rapid-Heating Sample & Transfer Zones with Minimal Thermal Gradient |
| Flow Control | High-Accuracy Pressure and Mass Flow Regulation |
| Data Synchronization | TTL/Relay Trigger Output for GC and Data System Coordination |
| Method Storage | 10 User-Defined Thermal Desorption Protocols |
| Brand | IBZ |
|---|---|
| Origin | Germany |
| Model | CHIRALYSER |
| Wavelength | 428 nm |
| Detection Principle | Faraday Modulation |
| Light Source | High-Stability LED |
| Noise | 20 μdeg |
| Drift | 10 μdeg |
| LOD | 0.5 mg/L [α = 90°, direct injection] |
| Max Flow Rate | 3 mL/min (semi-preparative compatible) |
| Output Signal | Analog (±10 V) |
| Brand | IMT |
|---|---|
| Origin | Germany |
| Model | VSP-4000 |
| Instrument Type | Dynamic Headspace Sampler |
| Automation Level | Fully Automatic |
| Sample Vial Heating Range | Ambient to 200 °C |
| Valve Oven Temperature Range | Ambient to 200 °C |
| Quantitative Loop Volume | 1 mL |
| Sample Capacity | 80 positions |
| Vial Format | 20 mL |
| Trap Configuration | Single Mikro-packed 1/16″ trap |
| Trap Cooling | Peltier-cooled cold trap at −35 °C |
| Detection Limit | ≤0.1 ppt (for selected VOCs) |
| Thermal Desorption Max Temp | Up to 280 °C (field-upgradable) |
| Optional Features | Internal Standard Addition Module, Split Flow up to 50 mL/min, Foam Sensor, Integrated Pressure & Mass Flow Control |
| Brand | INNOTEG |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | EasyNTC |
| Pricing | Available Upon Request |
| Brand | INNOTEG |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | T2110 |
| Temperature Range | Ambient to 400 °C |
| Gas Flow Rate | 0–200 mL/min |
| Tube Capacity | 10 tubes |
| Brand | Instrumax |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | CADetector a1 |
| Price Range | USD 42,000 – 49,000 (FOB Tianjin) |
| Compatible Systems | HPLC, UPLC, SFC |
| Detector Type | Charged Aerosol Detector (CAD), classified as a universal mass-sensitive detector distinct from ELSD |
| Brand | Instrumax |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Quaternary Solvent Delivery Pump |
| Max Pressure | 10000 psi |
| Flow Rate Range | 0.01–5 mL/min |
| Flow Accuracy | ±0.2% RSD |
| Flow Precision | ≤0.2% RSD |
| Brand | ISCO |
|---|---|
| Model | R1/R2 |
| Instrument Type | Liquid-Phase Fraction Collector |
| Collection Modes | Volume-, Time-, Drop-, and Peak-Triggered |
| Maximum Flow Rate | 100 mL/min |
| Dimensions (R1) | 31 × 33 × 35.5 cm |
| Dimensions (R2) | 31 × 53 × 38 cm |
| Weight (R1, without rack) | 7.7 kg |
| Weight (R2, without rack) | 10.6 kg |
| Power Supply | 115 VAC or 230 VAC, 50/60 Hz |
| Tube Rack Options | 144-12, 144-13, 100-16, 72-18, 36-25, 60-1.5, 36-50, 96-well plate compatible |
| Safety Features | Leak detection, electrical insulation protection |
| Mounting | Optional instrument stand for space optimization |
| Brand | JAI |
|---|---|
| Origin | Japan |
| Instrument Type | Curie-Point Pyrolyzer |
| Model | JCI-22 |
| Sample Heating | 160–1140 °C (via Curie-point heated Pt foil) |
| Preheating Temperature | 150 °C (≈60 s ramp) |
| Pyrolysis Zone Dimensions | 9 × 20 mm Pt foil |
| Sample Tube | Quartz |
| Probe Outer Diameter × Length | 35 × 180 mm |
| Probe Weight | 110 g |
| HF Generator Output | 48 W, 600 kHz |
| GC Trigger Interface | Ready signal input & Start signal output |
| Carrier Gas | He at ≥0.5 MPa (supplied via standard JCI-22 5 L cylinder) |
| Controller Dimensions | 150 × 200 × 320 mm |
| Compatibility | Direct insertion into standard GC/GC–MS split/splitless inlets |
