Chromatography Accessories
Filter
Showing 571–600 of 961 results
| Brand | JAI |
|---|---|
| Origin | Japan |
| Model | JHI-07 |
| Pyrolyzer Type | Microfurnace Pyrolyzer with Curie-Point Capability |
| Dual-Mode Operation | Curie-Point & Microfurnace |
| EGA Support | Yes |
| Quick-Release Interface | Yes |
| Column Head Cooler Compatibility | CIC-07 (Liquid Nitrogen Cooled) |
| Re-analysis Kit Included | Tenax GR Trap System for Targeted Peak Re-injection |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | JHP-5 |
| Instrument Type | Curie-Point Pyrolyzer |
| Heating Method | High-Frequency Induction (600 kHz, 48 W) |
| Pyrolysis Time Range | 1 s – 99 h |
| Flow Path Switching | Solenoid Valve |
| Sensor Unit Dimensions/Weight | 90 × 280 × 160 mm / 2.5 kg |
| RF Power Supply Dimensions/Weight | 160 × 250 × 380 mm / 8 kg |
| Power Input | AC 100–240 V, 5 A |
| GC Compatibility | Universal (all standard GC systems, excluding proprietary non-standard interfaces) |
| Brand | JAI |
|---|---|
| Origin | Japan |
| Model | JRS-86 |
| Control System | CPU-controlled |
| Sample Injection Volume Range | 100 µL to 50 mL |
| Injection Interval | 1–999 minutes |
| Maximum Number of Repetitive Injections | 99 |
| Compatible Systems | Integrated with JAI 9102 and 9103 Recirculating Preparative HPLC Units |
| Configuration | Rack-mounted, in-line installation at pump suction side |
| Brand | JAI |
|---|---|
| Origin | Japan |
| Model | JSP-20 |
| Sample Capacity | 1–20 vials |
| Injection Volume Range | 0.1–5.0 mL |
| Injection Precision | CV ≤ 1% |
| Maximum Operating Pressure | 20 MPa |
| Injection Repetition | 1–99 times per vial |
| Sequence Programmability | 1–20 order |
| Maximum Run Time | 999 minutes |
| Wash Mode | Dual solvent/air flush |
| Vial Type | 5 mL screw-thread glass vials |
| Sealing Materials | Silicone and PTFE |
| Needle Design | Dual-side-port stainless steel needle |
| Power Supply | AC 100 V / 3 A |
| Control Interface | Touchscreen LCD panel |
| Dimensions (W×H×D) | 250 × 300 × 435 mm |
| Weight | 15 kg |
| Brand | JAI |
|---|---|
| Origin | Japan |
| Instrument Type | Dual-Stage Thermal Desorber |
| Heating Method | Curie-Point (Standard 280 °C) + Resistive (–99 °C to 350 °C) |
| Cooling | Liquid Nitrogen (–99 °C) |
| Sample Capacity | Up to 48 sequential analyses (15 PAT tubes + programmable repeat/swap logic) |
| PAT Tube Dimensions | 12 mm ID × 50 mm height, 10 mL internal volume |
| Transfer Line Temp Range | Ambient +10 °C to 300 °C |
| GC Interface | Direct column connection or syringe-type injection |
| Power Supply | AC 100 V, 50/60 Hz, 15 A |
| RF Generator | 600 kHz, 48 W |
| Dimensions (Main Unit) | 355 × 210 × 130 mm, 3.1 kg |
| Liquid Nitrogen Dewar | 50 L (JTD-505III) / 20 L (JTD-505MIII), 460 mm Ø × 930 mm H, 24.8 kg |
| Brand | JAI |
|---|---|
| Origin | Japan |
| Model | RI-50s |
| Detector Type | Differential Refractometer (RID) |
| Flow Cell Volume | 8 µL |
| Refractive Index Range | 1.00–1.75 |
| Attenuation Range | 1–2000 and ∞ (12-step) |
| Temperature Control | Fixed at 34 °C, max 50 °C |
| Reference Cell Cleaning | Solenoid-valve controlled |
| Integrator Output | 1 V |
| Recorder Output | 100 mV / 10 mV |
| Zero Adjustment | Automatic |
| Dimensions (W×H×D) | 150 × 120 × 360 mm |
| Power Supply | AC 85–135 V, 50/60 Hz, 300 VA |
| Weight | 7 kg |
| Brand | JAI |
|---|---|
| Origin | Japan |
| Model | RI-7s |
| Detector Type | Differential Refractometer (RID) |
| Flow Cell Volume | 8 µL |
| Refractive Index Range | 1.00–1.75 |
| Attenuation Settings | 1–2000 and ∞ (12-step) |
| Temperature Control | Fixed at 34 °C, max 50 °C |
| Reference Cell Cleaning | Solenoid-valve actuated |
| Integrator Output | 1 V |
| Recorder Output | 100 mV / 10 mV |
| Zero Adjustment | Automatic |
| Dimensions (W×H×D) | 160 × 210 × 400 mm |
| Power Supply | AC 85–135 V, 50/60 Hz, 200 VA |
| Weight | 12 kg |
| Brand | JAI |
|---|---|
| Origin | Japan |
| Model | SW-8400 (for 6"/8" wafers) & SW-12400 (for 12" wafers) |
| Instrument Type | Secondary Thermal Desorber |
| Desorption Temperature Range | Ambient to 500 °C |
| Desorption Recovery Rate | 70% |
| Sample Capacity | 1 wafer per run |
| Sealing Material | Polyimide O-ring (220 mm ID) |
| Cooling | Integrated water-circulation system |
| Safety Features | Overheat protection (15 A/30 mA), interlock mechanism, emergency stop button (red mushroom type), optional water-leak sensor |
| Power Supply | Single-phase AC 200 V, 15 A and AC 100 V, 20 A |
| Dimensions (W×H×D) | 1140 × 1106 × 750 mm |
| Weight | 280 kg |
| Brand | JAI |
|---|---|
| Origin | Japan |
| Instrument Type | UV Detector (UVD) |
| Wavelength | Fixed at 254 nm |
| Detection Principle | Dual-Beam Filter Photometry |
| Light Source | Low-Pressure Mercury Lamp |
| Noise | ≤0.00015 AU |
| Drift | ≤0.002 AU/hr |
| Flow Cell Pathlength | 0.5 mm (standard), optional 0.2 mm and 1.0 mm |
| Flow Cell Volume | 20 µL |
| Maximum Sample Concentration Tolerance | 4% (with 0.5 mm cell) |
| Output Signal | 100 mV full scale |
| Zero Adjustment | Manual potentiometer |
| Dimensions (W×H×D) | 150 × 120 × 370 mm |
| Power Supply | AC 85–240 V, 50/60 Hz, 200 VA |
| Weight | 4 kg |
| Brand | JAI |
|---|---|
| Origin | Japan |
| Model | UV-310 |
| Wavelength Range | 195–370 nm |
| Detection Principle | Dual-Beam UV Absorbance |
| Light Source | Deuterium Lamp |
| Noise | ≤0.00005 AU |
| Drift | ≤0.002 AU/hr |
| Flow Cell Pathlength | 0.5 mm (standard), optional 0.2 mm and 1.0 mm |
| Flow Cell Volume | 20 µL |
| Maximum Sample Concentration Tolerance | 4% (with 0.5 mm cell) |
| Output Signals | 100 mV and 10 mV analog outputs |
| Zero Adjustment | Dual-stage coarse + fine tuning |
| Dimensions (W×H×D) | 156 × 225 × 450 mm |
| Power Supply | AC 85–135 V, 50/60 Hz, 200 VA |
| Weight | 14 kg |
| Brand | JAI |
|---|---|
| Origin | Japan |
| Model | UV-3702 |
| Detector Type | Ultraviolet-Visible (UV-Vis) Detector |
| Wavelength Range | 195–600 nm |
| Optical System | Dual-beam |
| Light Source | Deuterium Lamp |
| Noise | ≤0.00005 AU |
| Drift | ≤0.0005 AU/hr |
| Flow Cell Pathlength | 0.5 mm (standard), 0.2 mm / 1.0 mm optional |
| Flow Cell Volume | 20 µL |
| Full-Scale Output | 100 mV / 10 mV |
| Auto-Zero Function | Yes |
| Dimensions (W×H×D) | 156 × 225 × 450 mm |
| Power Supply | AC 85–135 V, 50/60 Hz, 200 VA |
| Weight | 14 kg |
| Brand | JAI |
|---|---|
| Origin | Japan |
| Model | UV-3740 |
| Detector Type | Ultraviolet-Visible (UV-Vis) Detector |
| Wavelength Range | 195–600 nm |
| Optical Design | Dual-beam |
| Light Source | Deuterium Lamp |
| Noise | ≤0.00002 AU |
| Drift | ≤0.0005 AU/hr |
| Flow Cell Pathlength | 0.5 mm (standard), optional 0.2 mm and 1.0 mm |
| Flow Cell Volume | 20 µL |
| Saturation Concentration | 4% (with 0.5 mm cell) |
| Output Signal | 10 mV full scale |
| Auto-zero Function | Yes |
| Dimensions (W×H×D) | 140 × 140 × 450 mm |
| Power Supply | AC 85–135 V, 50/60 Hz, 100 VA |
| Weight | 8 kg |
| Brand | JAI |
|---|---|
| Origin | Japan |
| Model | UV-4ch DAD Detector |
| Detection Principle | Diode Array Detection (DAD) |
| Wavelength Range | 190–840 nm (operational range 200–800 nm) |
| Simultaneous Channels | 4 independent wavelength channels |
| Light Source | Deuterium lamp + Tungsten-halogen lamp |
| Flow Cell Options | 0.3 mm (standard), 1.4 mm, 2.4 mm pathlength |
| Sensitivity | 5 × 10⁻⁵ AUFS |
| Drift | ≤ 1 × 10⁻³ AU/h |
| Zero Adjustment | Automatic |
| Software Compatibility | JAI Scan, Clarity™ (Windows Vista) |
| Power Supply | Direct LC system power |
| Dimensions (W×H×D) | 150 × 157 × 337 mm |
| Weight | ~6.0 kg |
| Brand | JAI |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | UV-50 |
| Instrument Type | Ultraviolet Detector (UVD) |
| Wavelength Range | 200–380 nm (selectable via interchangeable interference filters) |
| Standard Wavelength | 254 nm |
| Detection Method | Dual-Beam Filter Photometry |
| Light Source | Deuterium Lamp |
| Noise | ≤0.00005 AU |
| Drift | ≤0.002 AU/hr |
| Flow Cell Path Length | 0.5 mm (standard), optional 0.2 mm or 1.0 mm |
| Flow Cell Volume | 20 µL |
| Saturation Concentration | 4% (at 0.5 mm path length) |
| Output Signals | 100 mV and 10 mV full-scale analog outputs |
| Zero Adjustment | Automatic |
| Dimensions (W×H×D) | 150 × 120 × 420 mm |
| Power Supply | AC 85–135 V, 50/60 Hz, 100 VA |
| Weight | 8 kg |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | JH-1 |
| Pricing | Upon Request |
| Temperature Control Range | Ambient to 380 °C |
| Temperature Accuracy | ±1 °C |
| Calibration/Simulated Sampling Flow Rate | 100–1000 mL/min |
| Activation/Desorption Time Range | 1 min to 24 h (programmable) |
| Repeatability | >95% |
| Tube Dimensions Supported | Ø6 mm diameter, length >120 mm |
| Power Supply | 220 V ±10%, 50–60 Hz |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | JHP-22 |
| Instrument Type | Curie-Point Pyrolyzer |
| Heating Method | High-Frequency Induction with Curie-Point Ferromagnetic Foil |
| Sample Tube | Quartz, 4.5 mm ID (Pyrolysis Chamber) |
| Furnace Temperature Range | Ambient to 200 °C |
| Pyrolysis Duration | 1–99 s |
| Transfer Line Temperature Range | Ambient to 300 °C, Length: 0.7 m |
| RF Power Output | 48 W |
| Flow Path Switching | Solenoid Valve |
| Dimensions (W×H×D) | 305 × 190 × 465 mm |
| Weight | 18 kg |
| Power Supply | AC 100 V, 7 A |
| GC Compatibility | Universal GC Interface (Excluding Proprietary Direct-Coupled Systems) |
| Optional Curie Temperatures | 1040, 920, 764, 740, 670, 650, 590, 500, 485, 445, 423, 386, 358, 333, 315, 280, 255, 235, 220, 170, 160 °C |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | BS-100A |
| Instrument Type | Liquid-phase Fraction Collector |
| Collection Mode | Time-based |
| Tube Capacity | 100 × 12 mL |
| Timing Range | 1 s – 24 h (adjustable in 1-s increments) |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 265 × 390 × 390 mm |
| Weight | 8.35 kg |
| Data Retention on Power Loss | 10 years |
| Display | 6-digit high-brightness LED |
| Tube Tray | Circular, digitally numbered (1–100), solvent-resistant (optional) |
| Control Interface | RS-232 COM port for external pump synchronization |
| Enclosure Material | ABS polymer, injection-molded, fully enclosed |
| Panel Angle | 35° ergonomic tilt |
| Brand | Jiapeng |
|---|---|
| Model | BS-100A |
| Type | Liquid-phase Fraction Collector |
| Collection Mode | Time-based |
| Tube Capacity | 100 × 12 mL |
| Timing Range | 1 s – 24 h (adjustable in 1-s increments) |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 265 × 390 × 390 mm |
| Weight | 8.35 kg |
| Data Retention After Power Loss | ≥10 years |
| Display | Large Blue-backlit Chinese LCD with Menu-driven Interface |
| Housing Material | ABS Plastic (Injection-molded, Closed-loop Design) |
| Panel Angle | 35° Ergonomic Tilt |
| Tube Rack | Circular, Digitally Labeled (1–100), Interchangeable with Standard 12-mL Tube Formats |
| Valve Type | Keebio Fluid Shut-off Solenoid Valve |
| Compatibility | External Trigger via RS-232 COM Port (for Synchronization with Peristaltic Pumps) |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | BS-160A |
| Instrument Type | Liquid-phase Fraction Collector |
| Collection Mode | Time-based |
| Tube Capacity | 5 mL per tube |
| Max. Tube Count | 160 tubes |
| Timing Range | 1 second to 24 hours (user-selectable) |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 265 × 390 × 390 mm |
| Weight | 8.35 kg |
| Data Retention on Power Loss | 10 years |
| Display | 6-digit high-brightness LED |
| Housing Material | ABS plastic (injection-molded, enclosed design) |
| Tube Tray | Circular, digitally numbered, solvent-resistant (optional) |
| Valve Type | Keebio fluid shut-off valve |
| External Trigger Interface | RS-232 COM port for pump synchronization |
| Compliance | Designed for GLP-compliant preparative chromatography workflows |
| Brand | Jiapeng |
|---|---|
| Model | BS-160A |
| Type | Liquid-phase Fraction Collector |
| Collection Method | Time-based |
| Tube Capacity | 160 × 5 mL |
| Timing Range | 1 s – 24 h (adjustable in 1-s increments) |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 265 × 390 × 390 mm |
| Weight | 8.35 kg |
| Data Retention on Power Loss | ≥10 years |
| Housing Material | ABS polymer (chemical-resistant, injection-molded) |
| Display | Backlit Chinese-language LCD with menu-driven interface |
| Tube Tray | Circular, digitally numbered, solvent-compatible (optional) |
| Valve Type | Keebio fluid shut-off solenoid valve |
| External Trigger Interface | RS-232 COM port for synchronized control with peristaltic pumps |
| Compliance | Designed for GLP-aligned laboratory workflows |
| Brand | Jiapeng |
|---|---|
| Model | BS-16A |
| Type | Liquid-phase Fraction Collector |
| Collection Mode | Time-based |
| Tube Capacity | 16 × 100 mL |
| Timing Range | 1 s – 24 h (adjustable in 1-s increments) |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 265 × 390 × 460 mm |
| Weight | 6.5 kg |
| Data Retention | 10 years after power loss |
| Display | 6-digit high-brightness LED |
| Housing Material | ABS polymer (injection-molded, solvent-resistant grade) |
| Panel Angle | 35° ergonomic tilt |
| Tube Tray | Circular, digitally labeled (01–16), interchangeable with standardized 16-position racks |
| External Trigger Interface | RS-232 COM port for synchronized control with peristaltic or piston-driven pumps |
| Valve Type | Keebio precision fluid shut-off valve (standard) |
| Brand | Jiapeng |
|---|---|
| Model | BS-30A |
| Type | Liquid-phase Fraction Collector |
| Collection Method | Time-based |
| Number of Collection Positions | 30 |
| Collection Volume Capacity | Unlimited (via external containers) |
| Timing Range | 1 second to 24 hours (adjustable in 1-second increments) |
| Power Supply | AC 220 V, 50/60 Hz |
| Display | 6-digit high-brightness LED |
| Data Retention After Power Loss | ≥10 years |
| Continuous Operation Time | >200 hours |
| Housing Material | ABS (impact-resistant, solvent-resistant grade) |
| Control Interface | RS-232 COM port for external pump synchronization |
| Dimensions (W×D×H) | 265 × 390 × 530 mm |
| Net Weight | 6.5 kg |
| Brand | Jiapeng |
|---|---|
| Model | BS-40A |
| Type | Liquid-phase Fraction Collector |
| Collection Method | Time-based |
| Tube Capacity | 40 × 50 mL |
| Timing Range | 1 s – 24 h (adjustable in 1-s increments) |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 265 × 390 × 530 mm |
| Weight | 6.5 kg |
| Data Retention | 10 years after power loss |
| Display | 6-digit LED数码 tube |
| Tube Tray | Circular, digitally labeled, solvent-resistant (optional) |
| Enclosure Material | ABS plastic, injection-molded, fully enclosed |
| Interface | RS-232 COM port for external trigger (e.g., peristaltic pump synchronization) |
| Compliance | Designed for GLP-compliant preparative chromatography workflows |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | BSZ-100 |
| Collection Capacity | 100 tubes × 12 mL |
| Timing Range | 1 s – 24 h (adjustable in 1-s increments) |
| Display | 6-digit LED |
| Tube Tray | Circular, digitally numbered (001–100) |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 265 × 390 × 390 mm |
| Weight | 8.35 kg |
| Data Retention on Power Loss | ≥10 years |
| Continuous Operation Time | >200 h |
| Construction Material | ABS polymer (chemical-resistant, injection-molded) |
| Valve Type | Keebio fluid shut-off solenoid valve |
| Interface | RS-232 COM port for external trigger (e.g., peristaltic pump synchronization) |
| Brand | Jiapeng |
|---|---|
| Model | BSZ-100 |
| Type | Liquid-phase Fraction Collector |
| Collection Method | Time-based |
| Tube Capacity | 100 × 12 mL |
| Timing Range | 1 s – 199 h 59 min 59 s |
| Display | Chinese-language LCD (blue membrane, large-character) |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 265 × 390 × 390 mm |
| Weight | 8.35 kg |
| Data Retention After Power Loss | 10 years |
| Continuous Operation Time | >200 h |
| Housing Material | ABS (injection-molded, fully enclosed) |
| Control Interface | COM port for external pump triggering |
| Valve Type | Keebio fluid shut-off valve |
| Tube Tray | Circular, digitally numbered, solvent-resistant (optional) |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | BSZ-16 |
| Instrument Type | Liquid-phase Fraction Collector |
| Collection Method | Time-based |
| Tube Capacity | 16 × 100 mL |
| Timing Range | 1 s – 24 h (adjustable in 1-s increments) |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 265 × 390 × 530 mm |
| Weight | 6.5 kg |
| Data Retention After Power Loss | ≥10 years |
| Display | 6-digit high-brightness LED |
| Housing Material | ABS (injection-molded, solvent-resistant grade, optional) |
| Tube Tray | Circular, digitally labeled (01–16), 35° ergonomic tilt |
| Valve Type | Keebio fluid shut-off solenoid valve (chemically resistant) |
| External Trigger Interface | RS-232 COM port for synchronized control with peristaltic or piston pumps |
| Continuous Operation Duration | >200 h |
| Compliance | Designed for GLP-compliant chromatographic workflows |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | BSZ-160 |
| Instrument Type | Liquid-phase Fraction Collector |
| Collection Mode | Time-based |
| Tube Capacity | 5 mL per tube |
| Max. Tube Count | 160 |
| Timing Range | 1 s – 24 h (adjustable in 1-s increments) |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 265 × 390 × 390 mm |
| Weight | 8.35 kg |
| Data Retention After Power Loss | ≥10 years |
| Display | 6-digit high-brightness LED |
| Housing Material | ABS polymer (chemical-resistant, injection-molded) |
| Panel Angle | 35° ergonomic tilt |
| Tube Rack | Circular, digitally numbered for unambiguous identification |
| Valve Type | Keebio fluid shut-off solenoid valve |
| Compatibility | Interchangeable standard tube racks (same footprint) |
| External Trigger Interface | RS-232 COM port for synchronized control with peristaltic pumps |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | BSZ-160 |
| Collection Method | Time-Based |
| Tube Capacity | 5 mL per tube |
| Max. Tube Count | 160 |
| Timing Range | 1 s – 24 h (adjustable in 1-s increments) |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 265 × 390 × 390 mm |
| Weight | 8.35 kg |
| Data Retention After Power Loss | ≥10 years |
| Housing Material | ABS (high-impact, solvent-resistant grade) |
| Display | Backlit Chinese-language LCD with menu-driven interface |
| Compliance | Designed for GLP-compliant preparative chromatography workflows |
| External Trigger Interface | RS-232 (DB9 COM port) for synchronized operation with peristaltic pumps |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | BSZ-30 |
| Type | Liquid-phase fraction collector |
| Collection mode | Time-based |
| Number of collection positions | 30 |
| Collection volume capacity | Unlimited (with external containers) |
| Timing range | 1 second to 24 hours (adjustable in 1-second increments) |
| Power failure data retention | 10 years |
| Display | 6-digit high-brightness LED |
| Housing material | ABS plastic (medical-grade, solvent-resistant grade optional) |
| Control interface | RS-232 COM port for external pump synchronization |
| Compliance | Designed for GLP-compliant chromatography workflows |
| Dimensions (W×D×H) | 265 × 390 × 530 mm |
| Weight | 6.5 kg |
| Input power | AC 220 V, 50/60 Hz |
| Continuous operation capability | >200 hours |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | BSZ-40 |
| Collection Mode | Time-Based |
| Tube Capacity | 40 × 50 mL |
| Timing Range | 1 s – 24 h (adjustable in 1-s increments) |
| Power Supply | AC 220 V, 50/60 Hz |
| Display | 6-digit LED数码 tube indicator |
| Tube Tray | Circular, digitally numbered, solvent-resistant (optional) |
| Data Retention | 10 years after power loss |
| Continuous Operation | >200 h |
| Dimensions (W×D×H) | 265 × 390 × 530 mm |
| Weight | 6.5 kg |
| Compliance | Designed for GLP-aligned lab workflows |