Chromatography Accessories
Filter
Showing 691–720 of 1016 results
| Brand | OI Analytical |
|---|---|
| Origin | USA |
| Model | 4430 PID Photoinonization Detector |
| Detector Type | Photoionization Detector (PID) |
| Ionization Source | UV Lamp (10.6 eV standard) |
| Design Feature | Window Purge Technology |
| Compatibility | Universal GC Mounting Interface |
| Power Supply | Dedicated High-Voltage Module |
| Application Scope | Selective Detection of Aromatics, Alkenes, and Other VOCs with Ionization Potentials < 10.6 eV |
| Brand | OI Analytical |
|---|---|
| Origin | USA |
| Model | 4450 PID-FID |
| Detector Configuration | Integrated Series-Connected PID and FID |
| Compatible GC Interfaces | Single-detector port (supports dual 4450 installation with OI Dual-Channel Electronics) |
| Column Compatibility | Packed and Capillary Columns |
| Regulatory Alignment | Designed for EPA Method 8021B, ASTM D6728, and USP <467> residual solvent analysis |
| Brand | OI Analytical |
|---|---|
| Origin | USA |
| Model | 4760 |
| Sample Tray Capacity | 100 positions |
| Injection Precision | RSD ≤ 15% |
| Trap Temperature Range | 20–450 °C |
| Purge Heater Temperature | up to 150 °C |
| Sample Vial Cooling Temperature | 4–10 °C |
| Brand | OI Analytical |
|---|---|
| Origin | USA |
| Model | 5360XSD Halogen-Specific Detector |
| Detector Type | Halogen-selective, GC-compatible |
| Installation | Standard GC detector port (universal mounting interface) |
| Configuration Options | Standalone or in-series with OI 4430 PID |
| Detection Range | Sub-picogram to microgram levels of halogenated compounds |
| Regulatory Compliance | Designed to support EPA Method 8021B, ASTM D7412, and ISO 10302 workflows |
| Brand | OI Analytical |
|---|---|
| Origin | USA |
| Model | 5390 PID-XSD Tandem Detector |
| Detector Type | Photoionization Detector (PID) + Halogen-Specific Detector (XSD) |
| Configuration | In-series dual-detector module with single column outlet interface |
| Regulatory Compliance | Designed for ASTM D7622, EPA Method 8021B, and USP <621> chromatographic system suitability requirements |
| Software Integration | Compatible with standard GC data systems via analog voltage output (0–1 V) and TTL trigger signals |
| Brand | OI Analytical |
|---|---|
| Origin | USA |
| Model | PFPD 5383 |
| Detection Principle | Pulsed Flame Photometry |
| Element Specificity | S, P, N, Cl, Sn, As, Se, Te, and other heteroatoms |
| Dual-Channel Simultaneous Output | Yes |
| Self-Cleaning Combustion Chamber | Yes |
| Modular Electronics & Gas Path Architecture | Yes |
| Compliance | Designed for GC integration per ASTM D5291, EPA Method 1664/1671, USP <621>, ISO 8573-5 |
| Key Features | Temperature Range: RT+10°C to 132°C |
|---|---|
| Humidity Range | 100% RH (saturated steam) |
| Pressure Range | 0–2.8 kg/cm² (gauge), max safety capacity 4.0 kg/cm² |
| Internal Chamber Dimensions | Ø250×450 mm (OK-PTC-25) or Ø350×500 mm (OK-PTC-35) |
| Temperature Uniformity | ±1.5°C |
| Temperature Control Accuracy | ±0.5°C |
| Temperature Resolution | 0.1°C |
| Pressure Ramp Time | ~30 min (0 → 2.0 kg/cm²) |
| Construction | Inner chamber – SUS304 stainless steel |
| Compliance | ASTM D2247, IEC 60068-2-52, ISO 9022-14, JIS C 0068, MIL-STD-810H, NACE TM0177, UL 61010-1 |
| Brand | Otisens |
|---|---|
| Origin | Tianjin, China |
| Model | PCX-500 |
| Temperature Range | +5 °C above ambient to 150 °C |
| Derivatization Reagent Flow Rate | 5 µL/min to 2500 µL/min (or 5 µL/min to 10 mL/min) |
| Reaction Coil | Stainless Steel, 10 mm × 0.2 mm ID |
| Brand | Oushisheng |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | UV-Vis-1000 |
| Instrument Type | Online Chromatographic UV-Vis Detector |
| Wavelength Range | 200–1000 nm |
| Light Source | Pulsed Xenon Lamp |
| Detector Core | Miniature Fiber-Optic CCD Spectrometer |
| Optical Configuration | Transmission or Reflectance (via Optional Fiber Probe) |
| Typical Path Length | Configurable Flow Cell (Standard: 10 mm optical path) |
| Signal-to-Noise Ratio | ≥1000:1 (at 500 nm, 1 s integration) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | OV2001 / OV2000 |
| Temperature Control | Active Cooling & Heating |
| Safety Features | Over-Temperature Protection |
| Capacity | Accommodates 3–4 Standard HPLC/GC Columns |
| Control Algorithm | Dual-Mode Fuzzy Logic + PID Auto-Tuning |
| Uniformity | ±0.3 °C across column center zone |
| Monitoring | Real-Time Internal Temperature Tracking |
| Brand | PAS |
|---|---|
| Origin | Germany |
| Model | CONCEPT MIS |
| Instrument Type | GC Autosampler |
| Minimum Injection Volume | 1 µL |
| Positioning Accuracy | <0.3 mm |
| Motion System | XYZ Three-Axis |
| Needle Wash | Internal and External Wall Cleaning (Unlimited Cycles) |
| Re-injection Capability | Unlimited |
| Sample Introduction Modes | Liquid Injection (LI), Liquid–Liquid Extraction (LLE), Static/Dynamic Headspace (HS), Needle Trap (NT), Solid-Phase Microextraction (SPME), On-line Derivatization |
| Compliance | Designed for GLP/GMP environments with audit-trail-ready software architecture |
| Brand | OEM |
|---|---|
| Chamber Dimensions (OK-PTC-25) | Ø250 × 450 mm (D) |
| Chamber Dimensions (OK-PTC-35) | Ø350 × 500 mm (D) |
| Temperature Range | RT+10°C to 132°C |
| Humidity Range | 100% RH |
| Pressure Range | 0.0–2.8 kg/cm² (gauge), max safety capacity 4.0 kg/cm² |
| Temp. Uniformity | ±1.5°C |
| Temp. Control Accuracy | ±0.5°C |
| Temp. Resolution | 0.1°C |
| Pressurization Time (0→2.0 kg/cm²) | ~30 min |
| Inner Chamber Material | SUS304 stainless steel |
| Outer Casing | SECC steel with electrostatic powder coating |
| Compliance | ASTM, DIN, BS, IEC, NACE, UL, CNS, ISO, JIS, MIL |
| Key | Brand: GRACE |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Peak Biotech A/S |
| Pricing | Available Upon Request |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | HS2400 Headspace Sampler |
| Instrument Type | Dynamic Headspace Sampler |
| Automation Level | Fully Automated |
| Software Compatibility | Third-party Chromatography Data Systems (CDS), including Waters Empower™ |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | TurboMatrix 100 |
| Instrument Type | Two-Stage Thermal Desorber |
| Desorption Temperature Range | Ambient to 350 °C |
| Cryo-Focusing Trap Temperature Range | Down to −30 °C |
| Analyte Recovery Rate | >80% |
| Sample Capacity | 20 Sample Tubes |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | TurboMatrix 40 |
| Sample Capacity | 40 positions |
| Vial Size | 10 mL |
| Injection Valve Quantitative Loop Volume | 1 mL |
| Headspace Vial Heating Range | 35–210 °C (1 °C increments) |
| Injection Valve Temperature Control Range | Ambient to 210 °C |
| Sampling Technique | Pressure-Balanced Static/Dynamic Headspace with Optional Trap Enrichment |
| Automation Level | Fully Automated |
| Compatibility | Universal GC interface (all major GC brands) |
| Regulatory Compliance Support | 21 CFR Part 11-ready software architecture (when paired with TurboMass or Chromera CDS) |
| Data Integrity Features | Audit trail, user access levels, electronic signatures (software-dependent) |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer | PerkinElmer, Inc. |
| Product Type | Automated Thermal Desorber (Two-Stage) |
| Sample Capacity | 50-tube carousel |
| Cold Trap Temperature Range | −30 °C (electronic cooling, no liquid cryogen required) |
| Desorption Temperature Range | Ambient to 400 °C |
| Flow Control | Electronic Mass Flow Control (MFC) |
| Compliance | Compatible with all major GC systems (Agilent, Thermo Fisher, Shimadzu, etc.) |
| Software Interface | Graphical touchscreen with multilingual support (including English, Chinese, Spanish, German) |
| Data Integrity Features | Audit trail-ready configuration for GLP/GMP environments |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | 650 ATD |
| Instrument Type | Dual-Stage Thermal Desorber |
| Desorption Temperature Range | Ambient to 350 °C |
| Cold Trap Temperature Range | Down to −30 °C |
| Desorption Recovery Rate | >80% |
| Sample Capacity | 20 tubes |
| Flow Control | Electronic Mass Flow Control (MFC) |
| Cryogen-Free Cooling | Yes |
| GC Compatibility | Universal (all major GC brands) |
| Interface | Standard GC inlet connection (e.g., split/splitless, PTV) |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | PE 650 ATD |
| Instrument Type | Two-Stage Thermal Desorber |
| Desorption Temperature Range | Ambient to 350 °C |
| Cold Trap Temperature Range | Down to −30 °C (electronic cooling, no liquid cryogen) |
| Desorption Recovery Rate | >80% |
| Sample Capacity | 20 sample tubes |
| Flow Control | Electronic Mass Flow Control (MFC) |
| GC Compatibility | Universal interface for all major GC systems |
| Software Interface | Touchscreen GUI with graphical workflow navigation |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | TurboMatrix HS |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Sample Tray Capacity | 16 / 40 / 110 positions |
| Sample Vial Heating Range | 35–210 °C (1 °C increments) |
| Pressure Control Options | Manual (0–60 psig) or Electronic Pneumatic Control (EPC/PPC) |
| Detection Limit Enhancement | Integrated Focused Cryo-Trap for analyte enrichment |
| Typical Application Performance | ≤1.5% RSD for 0.4% aqueous ethanol |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | HS-40 |
| Instrument Type | Dynamic Headspace Sampler |
| Automation Level | Fully Automatic |
| Vial Heating Range | 35–210 °C |
| Valve Temperature Control Range | 35–210 °C |
| Loop Volume | 1 mL |
| Sample Tray Capacity | 16 / 40 / 110 positions |
| Vial Sizes Supported | 10 mL and 20 mL |
| Sampling Technique | Pressure-Balanced Headspace Injection |
| Compatible GC Interfaces | Universal (via standard GC inlet septumless or split/splitless ports) |
| Brand | Pickering Laboratories |
|---|---|
| Origin | USA |
| Model | PINNACLE PCX DELTA |
| Temperature Range | Ambient to 150 °C (programmable, ±1 °C stability) |
| Derivatization Reagent Flow Rate | 0.01–2.0 mL/min (precision ±0.5% RSD) |
| Reaction Coil Options | PEEK, FEP, or stainless steel (0.25–1.0 mm ID, 1–30 m length) |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Brand | Pickering |
|---|---|
| Origin | USA |
| Model | Onyx PCX |
| Temperature Range | 5 °C to 130 °C (ambient +5 °C) |
| Derivatization Reagent Flow Rate | 50 µL/min – 1500 µL/min |
| Reaction Coil Volume | 0.1–3 mL |
| Brand | Pickering |
|---|---|
| Origin | USA |
| Model | Vector PCX |
| Temperature Range | 5 °C – 130 °C |
| Derivatization Reagent Flow Rate | 0.05 – 2.0 mL/min |
| Reaction Coil Volume | 0.1 – 3.0 mL |
| Construction | PEEK Fluidic Path |
| Flow Control | Electronic, Pulse-Free |
| Safety | Integrated Leak Detection, Over-Temperature & Over-Pressure Protection |
| Compliance | Designed for GLP/GMP environments |
| Brand | Pribolab |
|---|---|
| Origin | Shandong, China |
| Model | KRC-200 |
| Derivatization Light Source | Dual-wavelength UV (254 nm / 352 nm) |
| Flow Rate Range | 0.6–2.0 mL/min |
| Optimal Flow Rate | 1.2 mL/min |
| Reaction Cell Volume | 1 mL |
| Maximum Pressure Rating | 10 MPa |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±2 nm |
| Bandwidth | 2 nm |
| Light Source Lifetime | ≥8000 h |
| Dimensions (H×W×D) | 88 mm × 90 mm × 420 mm |
| Operating Temperature | 0–45 °C |
| Relative Humidity | 20–85 % RH |
| Power Supply | 220 V ±10 %, 50 Hz ±2 % |
| Compliance | AOAC 2005.08, AOCS Aa11-05, Ph. Eur. 2.8.18, Chinese National Standards & ChP Methods |
| Brand | Pribolab |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MDS-2000 |
| Temperature Range | Ambient to 150 °C |
| Derivatization Reagent Flow Rate | 0.01–4.99 mL/min |
| Reaction Cell Volume | 1 mL |
| Flow Accuracy | ±0.5% |
| Flow Precision | 0.025% RSD |
| Pressure Range | 0–20 MPa |
| Power Supply | 220 V, 10 A |
| Dimensions (H×W×D) | 420 mm × 262 mm × 530 mm |
| Weight | 25 kg |
| Temperature Stability | ±0.02 °C |
| Temperature Setpoint Accuracy | ±0.1 °C |
| Temperature Equilibration Time | <20 min |
| Heating Power | 100 W |
| Standard Reaction Cell Volumes | 0.5 mL and 1 mL (optional range: 0.1–2 mL) |
| Fluidic Path Material | PEEK and optional stainless steel (SUS316) |
| Integrated Pulse Dampener | Yes |
| Backflow Prevention | Integrated check valve |
| Over-Temperature Protection | Active cutoff at 150 °C |
| Optional Online Degasser | Yes |
| Optional Pressurized Reagent Reservoir with SARAN™ tubing | Yes |
| Brand | Pribolab |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | MDS-3000-D |
| Temperature Range | Ambient + 5 °C to 150 °C |
| Derivatization Reagent Flow Rate | 0.01–9.999 mL/min |
| Reaction Coil Volume | 1 mL |
| Brand | Pribolab |
|---|---|
| Origin | Shandong, China |
| Model | MDS-3100 |
| Temperature Range | Ambient +5 °C to 150 °C |
| Derivatization Reagent Flow Rate | 0.01–9.999 mL/min |
| Reaction Coil Volume | 1 mL |
| Material Construction | PEEK fluidic path |
| Flow Accuracy | ≤0.5% |
| Flow RSD | ≤0.1% |
| Safety Features | Backflow prevention valve, overpressure protection (500 psi), overtemperature cutoff (150 °C), leak detection shutdown, inert gas pressurized reagent reservoir (optional) |
| Compliance | Designed for GLP/GMP-compliant HPLC workflows |
| Brand | Pribolab |
|---|---|
| Model | MDU-200 |
| Origin | Shandong, China |
| Derivatization Fluid Flow Rate | 1–2 mL/min |
| Reaction Coil Volume | 1 mL |
| Operating Temperature | Ambient |
| Compliance | AOAC Official Method 2005.08, AOCS Aa11-05, Ph. Eur. 2.8.18, Chinese Pharmacopoeia (2020 Ed.) & GB Standards |
| Brand | LabTech |
|---|---|
| Model | PT3000 |
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic (China-Made) |
| Pricing | Available Upon Request |