| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Nexera XS inert |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Application Scope | General-Purpose Bioanalytical LC |
| Flow Rate Range | 0.0001–10.0000 mL/min |
| Maximum Operating Pressure | 105 MPa |
| Flow Precision | ≤0.06% RSD or ≤0.02 min SD (whichever is greater) |
| Injection Volume Range | 0.1–50 µL |
| Autosampler Capacity | 252 positions (1 mL vials) / 162 positions (1.5–2 mL vials) / 84 positions (4 mL vials) |
| Column Oven Temperature Range | Ambient −10 °C to 100 °C (85 °C for high-stability operation) |
| UV-Vis Wavelength Range | SPD-40 detector: 190–700 nm |
| SPD-40V detector | 190–1000 nm |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Nexera-e |
| Instrument Type | Comprehensive 2D-LC System |
| Flow Rate Range | Not Applicable (Modular Dual-Flow Architecture) |
| Maximum System Pressure | 130 MPa (2nd Dimension) |
| Sample Injection Positions | Dual Sample Loops with Alternating Switching |
| Injection Volume Range | Configurable via Loop Selection (e.g., 1–100 µL) |
| Column Oven Temperature Range | Ambient to 85 °C |
| Wavelength Range (DAD) | 190–800 nm |
| Data Acquisition Rate | Up to 125 Hz (SPD-M30A), 20,000 u/sec (LCMS-IT-TOF) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | CAGC-2030 |
| Price Range | USD 42,000 – 70,000 |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | Nexis GC-2030 Enhanced Edition |
| Price Range | USD 42,000 – 70,000 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-purpose |
| Oven Temperature Range | Ambient +2 °C to 450 °C |
| Maximum Ramp Rate | 250 °C/min |
| Cooling Rate | 450 °C → 50 °C in ≤3.4 min (at 22 °C ambient) |
| Carrier Gas Flow Control Range | 0–1250 mL/min (7 programmable segments) |
| Carrier Gas Pressure Control Range | 0–1035 kPa (7 programmable segments) |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–1035 kPa |
| Total Injector Flow Setting Range | 0–1300 mL/min (He or H₂), 0–600 mL/min (N₂) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | Nexis GC-2030 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-purpose |
| Oven Temperature Range | Ambient +2 °C to 450 °C |
| Maximum Ramp Rate | 250 °C/min |
| Cool-down Time | ≤3.4 min (from 450 °C to 50 °C at ambient 22 °C) |
| Carrier Gas Flow Control Range | 0–1250 mL/min (7 programmable segments) |
| Carrier Gas Pressure Control Range | 0–1035 kPa (7 programmable segments) |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–1035 kPa |
| Injector Total Flow Setting Range | 0–1300 mL/min (He or H₂), 0–600 mL/min (N₂) |
| Key | Brand: Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose Analysis |
| Oven Temperature Range | Ambient +2 °C to 450 °C |
| Oven Ramp Rate | 0.01–250 °C/min |
| Oven Cool-Down Time | ~3.4 min (450 °C → 50 °C) |
| Carrier Gas Flow Control | 0–1300 mL/min He |
| Carrier Gas Pressure Control | 0–1035 kPa (7 programmable segments) |
| Injector Max Temp | 450 °C |
| Injector Pressure Setting Range | 0–1035 kPa |
| Injector Total Flow Setting Range | 0–1300 mL/min He |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Nexlock |
| Pricing | Available Upon Request |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Petrochemical Accessories Kit |
| Instrument Type | Laboratory Gas Chromatograph Accessories |
| Application Field | Petroleum & Petrochemical Industry |
| Key Components | G-VAPORIZER Flash Vaporizer |
| Compliance | Designed for ASTM D1319, D5769, D6730, ISO 6974, and USP <467> residual solvent methods |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Instrument Type | Laboratory Benchtop Ion Chromatograph |
| Detection Modes | Suppressed and Non-Suppressed Conductivity Detection |
| Application Scope | Trace Anion and Cation Analysis in Environmental, Pharmaceutical, Food, and Industrial Samples |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | Prominence Plus LC-20A |
| Instrument Category | Fast Liquid Chromatography System |
| Application Scope | General-purpose HPLC analysis |
| Maximum Operating Pressure | 44 MPa (LC-20AT) / 66 MPa (LC-20ADXR) |
| Flow Rate Precision | ≤0.06% RSD or ≤0.02 min SD |
| Injection Volume Range | 0.1–50 µL (standard), 0.1–2000 µL (optional) |
| Sample Tray Capacity | 175 positions (1 mL vials) |
| Column Oven Temperature Range | Ambient +10 °C to 85 °C (standard) |
| UV-Vis Detection Wavelength Range | 190–700 nm |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Prominence Plus LC-30A |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Application Scope | General-Purpose Analytical Platform |
| Flow Rate Range | 0.0001–10.0000 mL/min |
| Maximum Operating Pressure | 130 MPa |
| Flow Rate Precision | <0.06% RSD or 0.02 min SD (whichever is greater) |
| Injection Volume Range | 0.1–50 µL |
| Sample Capacity | 175 positions (1 mL vials) |
| Column Oven Temperature Range | Ambient ±10 °C to 85 °C |
| UV-Vis Detection Wavelength Range | 190–700 nm |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Prominence UFLC |
| Instrument Type | Ultra-Fast Liquid Chromatograph |
| Pricing | Available Upon Request |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Category | Imported Instrument |
| Model | Prominence UFPLC |
| Pricing | Available Upon Request |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Instrument Type | Conventional HPLC System |
| Flow Rate Range | 0.001–10.000 mL/min |
| Maximum Pressure | 40 MPa |
| Autosampler Capacity | 100 positions |
| Injection Volume Range | 1–50 µL |
| Column Oven Temperature Range | 10–60 °C |
| UV-Vis Wavelength Range | 190–700 nm |
| Data Acquisition Rate | 100 Hz |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RF-10A |
| Pricing | Upon Request |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RF-10A |
| Price | Upon Request |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Category | Imported Instrument |
| Model | SIL-30ACMP |
| Pricing | Available Upon Request |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SPD-10Avp |
| Instrument Type | Conventional HPLC Detector |
| Wavelength Range | 190–600 nm |
| Noise | ±0.35 × 10⁻⁵ AU |
| Drift | ≤ ±2 × 10⁻⁴ AU/h |
| Flow Cell Volume | 8 µL (standard) |
| Dimensions | 260 × 140 × 420 mm (W × H × D) |
| Weight | 13 kg |
| Operating Temperature | 4–35 °C |
| Lamp | Long-life Deuterium Lamp (D₂), programmable ON/OFF control |
| Optical Design | Separated lamp chamber and monochromator with active lamp cooling |
| Baseline Stability | Engineered for high reproducibility in regulated QC environments |
| Brand | Shine / SHINE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | CIC-D100 |
| Instrument Type | Laboratory Benchtop |
| Application Scope | General-Purpose Ion Analysis |
| Maximum Pump Pressure | 42 MPa |
| Flow Rate Range | 0.001–9.999 mL/min |
| Eluent Flow Rate Range | 0.001–9.999 mL/min |
| Maximum Operating Pressure | 42 MPa |
| Column Oven Temperature Range | 20–60 °C |
| Eluent Concentration Range | 0.01–100 mM |
| Brand | Shine |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | CIC-D120+ |
| Instrument Type | Laboratory Benchtop |
| Application Scope | General-Purpose Ion Analysis |
| Pump Maximum Pressure | 42 MPa |
| Flow Rate Range | 0.001–9.999 mL/min |
| System Operating Pressure Limit | 10 MPa |
| Brand | Shine |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Region Category | Domestic (China) |
| Model | CIC-D150 |
| Instrument Type | Laboratory Benchtop |
| Application Scope | General-Purpose Ion Analysis |
| Maximum Pump Pressure | 35 MPa |
| Flow Rate Range | 0.001–9.999 mL/min |
| Eluent Flow Rate Range | 0.001–9.999 mL/min |
| Maximum Operating Pressure | 35 MPa |
| Operating Temperature Range | Ambient +5 °C to 60 °C |
| Temperature Reproducibility | ±0.2 °C |
| Eluent Concentration Range | 0.1–100 mM |
| Brand | Shine |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | CIC-D160+ Ion Chromatograph |
| Instrument Type | Laboratory Benchtop |
| Application Scope | General-Purpose Ion Analysis |
| Maximum Pump Pressure | 42 MPa |
| Flow Rate Range | 0.1–5.0 mL/min |
| Brand | Shine |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | CIC-D160Z |
| Instrument Type | Laboratory |
| Application Scope | General-Purpose |
| Maximum Pump Pressure | 42 MPa |
| Operating Temperature Range | 15–60 °C |
| Suppressor Design | Integrated High-Pressure Chemical Regeneration Suppressor |
| Eluent Generation | Built-in Hydroxide Eluent Generator (water-fed, current-controlled) |
| Column Oven | Integrated Bidirectional Thermostatic Control (15–60 °C, programmable) |
| Fluidic Path | All-PEEK, pH 0–14 Compatible |
| Detector | Embedded Constant-Temperature Conductivity Detector with Auto-Ranging (ppb–ppm linear dynamic range) |
| CO₂ Removal | Integrated Post-Suppression CO₂ Degassing Module |
| Degasser | Built-in Low-Pressure Online Degasser |
| Suppressor Architecture | Triple-Cartridge Rotating Suppressor (120° step rotation, acid-regenerated, real-time cartridge switching) |
| Suppressor Lifetime | ≥10 years under typical operating conditions |
| Organic Solvent Tolerance | Compatible with high-percentage methanol and acetonitrile eluents |
| Brand | Shine |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | CIC-D180 |
| Instrument Type | Laboratory Benchtop |
| Application Scope | Universal Ion Analysis |
| Maximum Pump Pressure | 35 MPa |
| Flow Rate Range | 0.1–5.0 mL/min |
| Eluent Delivery Precision | 0.001–9.999 mL/min |
| Max Operating Pressure | 35 MPa |
| Column Oven Temperature Range | Ambient +5 °C to 60 °C ±0.01 °C |
| Temperature Reproducibility | ±0.2 °C |
| Eluent Concentration Range | 0.1–100 mM |
| Brand | Shine |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | CIC-D180H |
| Instrument Type | Laboratory |
| Application Scope | General-Purpose |
| Maximum Pump Pressure | 42 MPa |
| Flow Rate Range | 0.001–15 mL/min |
| Maximum Operating Pressure | 45 MPa |
| Operating Temperature Range | 15–60 °C |
| Brand | Shine |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Laboratory Benchtop Ion Chromatograph |
| Application Scope | General-Purpose Anion and Cation Analysis |
| Maximum System Pressure | 42 MPa |
| Flow Rate Range | 0.1–10.0 mL/min |
| Eluent Flow Rate Range | 0.1–5.0 mL/min |
| Operating Temperature | Ambient |
| Eluent Concentration Range | 0.1 mM |
| Detection Compatibility | Conductivity (CD), Electrochemical (ECD), UV-Vis, DAD, ICP-OES, AFS, MS |
| Brand | Shine |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Benchtop Ion Chromatograph |
| Application | Dedicated Multi-Ion Analysis System |
| Pump Maximum Pressure | 35 MPa (PEEK construction) |
| Flow Rate Range | 0.1–5.0 mL/min |
| Eluent Delivery Precision | 0.001–9.999 mL/min |
| Max Operating Pressure | 35 MPa (PEEK) |
| Operating Temperature Range | Ambient +5°C to 60°C |
| Temperature Reproducibility | ±0.2°C |
| Eluent Concentration Range | 0.1–100 mM |
| Brand | Shine |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Laboratory Benchtop IC System |
| Application Scope | Universal |
| Maximum Pump Pressure | 42 MPa (PEEK construction) |
| Flow Rate Range | 0.1–5.0 mL/min |
| Eluent Flow Accuracy | 0.001–9.999 mL/min |
| Operating Temperature Range | Ambient +5 °C to 60 °C (±0.01 °C setpoint stability) |
| Temperature Reproducibility | ±0.2 °C |
| Eluent Concentration Range | 0.1–100 mM |
| Dual Independent Channels | Yes |
| Online Eluent Generator | Integrated |
| Suppressor Type | Next-generation membrane-based suppressor |
| Detector Compatibility | Conductivity, Pulsed/Ampere, Integrative Amperometric |
| IC-MS & IC-ICP/MS Ready | Yes |
| Online Degassing | Dual-stage (low-pressure vacuum + gas–liquid phase separation) |
| Pre-column Eluent Thermal Buffering | Yes |
| Post-run Auto-Flush | Yes |
| Pure Water Purification Module | Integrated inline deionization and particulate filtration |
| Brand | Shine (SHINE) |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China-made) |
| Model | CIC-D500+ |
| Instrument Type | Laboratory Benchtop System |
| Application Profile | Specialized Multi-Mode Analytical Platform |
| Operating Temperature Range | Ambient + 5 °C to 60 °C |
| Brand | Shine |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Portable Ion Chromatograph |
| Model | CIC-P80 |
| Application Scope | Field-Deployable General-Purpose Inorganic Anion/Cation Analysis |
| Power Supply | Dual-mode (AC Mains or External Power Bank, 4 h per bank, hot-swap enabled) |
| Sample Introduction | Integrated Syringe-Free Suction-Based Autosampler |
| Fluidic Architecture | Electrically Isolated Water/Electrical Circuit Layout with Sealed Enclosure |
| User Interface | 7-inch Capacitive Touchscreen + Optional Bluetooth Keyboard/Mouse Support |
| Compliance Context | Designed for field use under ISO/IEC 17025-aligned operational practices |