Chromatography Instruments
Filter
Showing 1231–1260 of 1564 results
| Brand | SRI |
|---|---|
| Origin | USA |
| Model Variants | 110, 310, 410, 8610C, 8610D |
| Configuration | Benchtop or Portable Chassis Options |
| Detectors | FID, TCD, SCD, PID (User-Selectable) |
| Compliance | ASTM D1945, D1946, D3588, ISO 8573-5, USP <467>, EPA Method TO-14A/TO-15 |
| Data System | Standalone PC-Based Acquisition & Processing Software (No Dedicated Terminal Required) |
| Brand | SRI |
|---|---|
| Origin | USA |
| Model | 8610 |
| Detection Limit | 1 ppb |
| Dimensions | 49.5(W) × 36.8(D) × 34.3(H) cm |
| Regulatory Compliance | EPA Methods 8010, 8015, 8021 |
| Carrier Gas Control | Electronic Pressure Control (EPC), 0–80 psi programmable at 90 psi/min |
| Column Oven | Ambient to 400 °C, 0.01 °C resolution, ±0.1 °C stability, 19.8 × 19.0 × 7.6 cm internal volume |
| Detector Options | 16 configurable detectors, up to 6 simultaneously installed |
| Injection Modes | 12 selectable methods, up to 5 concurrently configured |
| Software | PeakSimple v4.x, USB interface, 4-channel data acquisition |
| Brand | SRI |
|---|---|
| Origin | USA |
| Model | SRI-8610C |
| Instrument Type | Portable Gas Chromatograph |
| Temperature Control Range | 0–400 °C |
| Temperature Ramp Rate | 0.1 °C/min (programmable) |
| Cool-down Time | ~15 min (400 °C to ambient) |
| Carrier Gas Flow Control | Electronically adjustable |
| Carrier Gas Pressure Control | 0–80 psi (EPC-programmable) |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setpoint Range | 0–80 psi (programmable) |
| Injector Total Flow Setpoint Range | Adjustable |
| Brand | SRI |
|---|---|
| Origin | USA |
| Model | 8610C (Pesticide Residue Configuration) |
| Instrument Type | Portable Gas Chromatograph |
| Temperature Control Range | 0–400 °C |
| Temperature Ramp Rate | 0.1 °C/min (minimum programmable increment) |
| Cooling Time | ~15 min (from 400 °C to ambient) |
| Carrier Gas Flow Range | Adjustable (EPC-controlled) |
| Carrier Gas Pressure Range | 0–80 psi (programmable EPC) |
| Injector Maximum Temperature | 400 °C |
| Injector Pressure Setpoint Range | 0–80 psi (programmed) |
| Injector Total Flow Setpoint Range | Adjustable |
| Brand | SRI |
|---|---|
| Origin | USA |
| Model | 8610C (Routine Configuration) |
| Instrument Type | Portable Gas Chromatograph |
| Application Field | Environmental Monitoring |
| Oven Temperature Range | 0–400 °C |
| Temperature Ramp Rate | 0.1 °C/min (minimum programmable increment) |
| Cool-down Time | ~15 min (from 400 °C to ambient) |
| Carrier Gas Flow Control | Electronically adjustable |
| Carrier Gas Pressure Range & Control | 0–80 psi, program-controlled via EPC |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setpoint Range | 0–80 psi, fully programmable |
| Injector Total Flow Setpoint Range | Electronically adjustable |
| Brand | SRI |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SRI |
| Price Range | USD 14,000 – 42,000 |
| Brand | SSI |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Model 6000 Diode Array Detector |
| Pricing | Available Upon Request |
| Wavelength Range | 190–800 nm |
| Optical Path Length / Flow Cell Volume | 5 cm / 12 µL |
| Noise | ±3 × 10⁻⁶ AU/cm |
| Drift | 1 × 10⁻³ AU/hr |
| Linearity | >2.0 AU |
| Scan Rate | ≤20 Hz |
| Spectral Resolution | 1.2 nm |
| Wavelength Accuracy | ±1 nm |
| Light Source | Deuterium Lamp + Tungsten-Halogen Lamp |
| A/D Converter | 20-bit |
| Photodiode Array | 512 elements |
| Beam Conditioning | Stacked Optical Fiber Assembly |
| Calibration Reference | Holmium Oxide (Ho₂O₃) Solution Cell |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PC-2000 |
| Instrument Type | Conventional High-Performance Liquid Chromatograph (HPLC) |
| Maximum Pressure | 6000 psi |
| Flow Rate Range | 0.01–19.98 mL/min |
| Gradient Accuracy | ±0.1% |
| Baseline Noise | 1 × 10⁻⁵ AU |
| Baseline Drift | 2 × 10⁻⁴ AU/hr |
| Detector | SSI Model 500 UV-Vis Variable Wavelength Detector |
| Brand | LabAlliance |
|---|---|
| Origin | USA |
| Model | SSI Prep 2100 |
| Pump Flow Rate | Up to 100 mL/min per pump |
| Gradient Modes | Step, Linear, and Curvilinear (Programmable) |
| Detector Options | UV-Vis (UV201, wavelength-programmable), RID, ELSD (with flow splitter) |
| Fraction Collection | FC Jr. Fraction Collector (time-, volume-, drop-, or peak-triggered) |
| Construction | Stainless steel flow path |
| Compliance | FDA 21 CFR Part 11, GLP-ready audit trail |
| Brand | STT |
|---|---|
| Origin | Beijing, China |
| Manufacturer | STT Senfu Technology |
| Model | EQ STT-5000 |
| Detection Limit | 0.1 ppb for benzene |
| Weight | 2.2 kg |
| Dimensions | 267 × 197 × 308 mm |
| Column | MEMS microfabricated capillary column |
| Detector | 10.6 eV Photoionization Detector (PID) |
| Measurement Range | 0.1–300 ppb (benzene, low-range mode) or 50 ppb–10 ppm (benzene, high-range mode) |
| Accuracy | ±1% FS |
| Carrier Gas | Ambient air (filtered via activated carbon and molecular sieve) |
| Battery Life | >9 hours |
| Compliance | GB/T 18883-2022 Annex C.3, EPA Method 5035, EPA Method 8021 |
| Brand | STT |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | EQ STT-5000 |
| Detection Limit | 0.1 ppb for benzene |
| Weight | 2.2 kg |
| Dimensions | 267 × 197 × 308 mm |
| Brand | STT |
|---|---|
| Origin | Beijing, China |
| Manufacturer | STT Senfu Technology |
| Model | EQ-STT-5000 |
| Detection Limit | 0.1 ppb (benzene) |
| Weight | 2.2 kg |
| Dimensions | 267 × 197 × 308 mm |
| Column | Microfabricated GC column with 10.6 eV PID detector |
| Power | Built-in rechargeable battery (>9 h operation) |
| Carrier Gas | Ambient air (filtered via activated carbon + molecular sieve) |
| Measurement Range | 0.1–300 ppb or 50 ppb–10 ppm (benzene) |
| Accuracy | ±1% FS |
| Sample Matrices | Air, water (with optional headspace module), soil (with optional thermal desorption unit) |
| Brand | STT |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | EQ-STT-5000 |
| Detection Limit | 0.1 ppb for benzene |
| Weight | 2.2 kg |
| Dimensions | 267 × 197 × 308 mm |
| Column Technology | MEMS microfabricated capillary column |
| Detector | 10.6 eV Photoionization Detector (PID) |
| Carrier Gas | Ambient air (with activated carbon + molecular sieve filtration) |
| Battery Life | >9 h |
| Measurement Range | 0.1–300 ppb (benzene, low-range mode) or 50 ppb–10 ppm (benzene, high-range mode) |
| Accuracy | ±1% FS |
| Sample Matrices | Air, water (with headspace module), soil (with thermal desorption accessory) |
| Brand | Sunny Hengping Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-made) |
| Model | GC1120 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-purpose |
| Oven Temperature Range | Ambient +7 °C to 400 °C |
| Oven Ramp Rate | 0–40 °C/min |
| Oven Cool-down Rate | 250 °C to 50 °C in ≤7 min |
| Carrier Gas Flow Range & Control | 0–200 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.3 MPa |
| Injector Maximum Operating Temperature | 420 °C |
| Injector Pressure Setting Range | 0–0.3 MPa |
| Injector Total Flow Setting Range | 0–200 mL/min |
| Brand | Sunny Hengping Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | GC1120 NMHC-Dedicated Gas Chromatograph |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Environmental Monitoring |
| Oven Temperature Range | Ambient +7 °C to 400 °C |
| Oven Ramp Rate | 0–40 °C/min |
| Oven Cooling Rate | 250 °C to 50 °C in ≤7 min |
| Carrier Gas Flow Range & Control | 0–200 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.3 MPa |
| Injector Maximum Operating Temperature | 420 °C |
| Injector Pressure Setting Range | 0–0.3 MPa |
| Injector Total Flow Setting Range | 0–200 mL/min |
| Brand | Sunny Hengping Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-Made) |
| Model | GC1290 |
| Instrument Category | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | Ambient + 5°C to 420°C |
| Ramp Rate | 0–80°C/min |
| Cool-Down Time | <2.5 min (from 350°C to 100°C) |
| Carrier Gas Flow Range & Control | 0–200 mL/min |
| Carrier Gas Pressure Range & Control | 0–100 psi |
| Injector Maximum Operating Temperature | 420°C |
| Injector Pressure Setpoint Range | 0–100 psi |
| Injector Total Flow Setpoint Range | 0–250 µL/min |
| Brand | Sunny Hengping Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | IC1800 |
| Instrument Type | Laboratory Benchtop System |
| Pump Pressure Range | 0–25 MPa |
| Flow Rate Range | 0.000–9.999 mL/min |
| Eluent Flow Rate Range | 0.000–9.999 mL/min |
| Maximum Operating Pressure | 25 MPa |
| Column Oven Temperature Range | Ambient to 60 °C |
| Temperature Reproducibility | ±0.1 °C within ambient +2 °C to 100 °C |
| Eluent Concentration Range | 0–100 mmol/L (expressed as OH⁻) |
| Brand | Sunny Hengping Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | IC1820 |
| Instrument Type | Laboratory Benchtop |
| Maximum Pump Pressure | 35 MPa |
| Flow Rate Range | 0–9.999 mL/min |
| Eluent Flow Rate | 1.5 mL/min |
| Max Operating Pressure | 15 MPa |
| Column Oven Temperature Range | 25–60 °C |
| Temperature Stability | ±0.5 °C |
| Eluent Concentration Range | 0–100 mM (OH⁻ or CO₃²⁻/HCO₃⁻) |
| Brand | Sunny Hengping Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Origin | Domestic (China) |
| Model | LC1620A |
| Instrument Category | Conventional HPLC System |
| Flow Rate Range | 0.001–9.999 mL/min |
| Maximum Pressure | 45 MPa |
| Autosampler Capacity | 0–120 positions |
| Injection Volume Range | 0–120 µL |
| Column Oven Temperature Range | Ambient +5°C to 100°C |
| UV-Vis Wavelength Range | 190–700 nm |
| Data Acquisition Frequency | 1 Hz |
| Brand | Sunny Hengping Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | LC1620APlus |
| Price Range | USD 7,000–14,000 (FOB Shanghai) |
| Instrument Type | Conventional HPLC System |
| Application Scope | General-Purpose Analytical HPLC |
| Flow Rate Range | 0.000–10.000 mL/min |
| Maximum Operating Pressure | 42 MPa |
| Flow Accuracy | ≤ ±0.3% RSD |
| Wavelength Range (UV-Vis Detector) | 190–680 nm |
| Brand | Sykam |
|---|---|
| Origin | Germany |
| Model | S-150 |
| Instrument Type | Laboratory |
| Pump Pressure Range | 0–40 MPa |
| Flow Rate Range | 0.000–10.000 mL/min |
| Eluent Flow Rate Range | 0.000–10.000 mL/min |
| Maximum Operating Pressure | 35 MPa |
| Operating Temperature Range | 5–35 °C |
| Temperature Reproducibility | ±0.01 °C |
| Eluent Concentration Range | Application-dependent (compatible with common carbonate/bicarbonate, hydroxide, methanesulfonic acid, and other IC eluents) |
| Brand | Sykam |
|---|---|
| Origin | Germany |
| Model | S-433D |
| Instrument Type | Post-column Derivatization Amino Acid Analyzer |
| Pump Flow Rate | 0.000–9.999 mL/min |
| Maximum Pump Pressure | 40 MPa (400 bar, 6000 psi) |
| Autosampler Injection Volume | 1–500 µL |
| Autosampler Temperature Control | +4 °C to 70 °C (electronic thermostating) |
| Post-column Reactor Temperature Range | Ambient to 180 °C (temperature stability ±0.1 °C) |
| Detection Wavelengths | Simultaneous dual-wavelength detection at 570 nm and 440 nm |
| Flow Cell Volume | 8 µL |
| Brand | Sykam |
|---|---|
| Origin | Germany |
| Model | S-501 |
| Instrument Type | Conventional High-Performance Liquid Chromatograph |
| Flow Rate Range | 0.001–10.000 mL/min |
| Maximum Pressure | 40 MPa |
| Autosampler Capacity | 120 positions |
| Injection Volume Range | 0.1–999.9 µL |
| Column Oven Temperature Range | 4–100 °C |
| UV/Vis Wavelength Range | 190–800 nm |
| Data Acquisition Rate | 10 Hz |
| Brand | Sykam |
|---|---|
| Origin | Germany |
| Model | S-504 |
| Instrument Type | Conventional High-Performance Liquid Chromatograph |
| Flow Rate Range | 0.001–10.000 mL/min |
| Maximum Pressure | 40 MPa |
| Autosampler Capacity | 60 positions × 1.5 mL vials or 96 positions × 0.5 mL vials |
| Injection Volume Range | 0.1–999.9 µL |
| Column Oven Temperature Range | 4–100 °C |
| UV/Vis Wavelength Range | 190–800 nm |
| Data Acquisition Rate | 10 Hz |
| Brand | Sykam |
|---|---|
| Origin | Germany |
| Model | S433D |
| Instrument Type | Post-Column Derivatization System |
| Pump Flow Rate | 0–9.999 mL/min |
| Maximum Pump Pressure | 40 MPa |
| Autosampler Injection Volume | 0–500 µL |
| Autosampler Temperature Control | +5 °C to 70 °C (electronic thermostating) |
| Post-Column Reactor Temperature Range | Ambient to 180 °C |
| Detection Wavelengths | 570 nm and 440 nm |
| Flow Cell Volume | 8 µL |
| Brand | Synpec |
|---|---|
| Model | M3000 Micro GC |
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Detection Principle | Micro-Electro-Mechanical Systems (MEMS)-Based Thermal Conductivity Detection (μTCD) |
| Detector Pool Volume | 200 nL |
| Detection Limit | 0.5 ppm (for H₂, CO, CH₄, etc., in N₂ carrier) |
| Analysis Time | < 30 s per channel (multi-channel parallel operation) |
| Column Type | Capillary micro-column (ID ≤ 0.15 mm) |
| Power Supply | Internal rechargeable Li-ion battery (8 h continuous operation) |
| Carrier Gas | Integrated miniature high-pressure gas cylinder (N₂ or He) |
| Communication Interfaces | RS-485, MODBUS RTU, digital/analog I/O |
| Software | Onboard embedded OS with method editor, real-time data processing, and automated report generation |
| Compliance | Designed to support GLP/GMP-aligned workflows |
| Brand | Synpec |
|---|---|
| Model | P200OEM |
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Price Range | USD 14,000 – 42,000 |
| Brand | Synpec |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Region of Origin | Domestic (China) |
| Model | P200GC |
| Price Range | USD 14,000 – 43,000 |
| Dimensions | 410 mm (L) × 280 mm (W) × 235 mm (H) |
| Weight | ≤10 kg |
| Analysis Cycle | NMHC: ≥1 min |
| BTEX | ≥5 min |
| Measurement Range | 0–50,000 ppm |
| LOD | 0.05 ppm |
| Repeatability | RSD ≤1% |
| Accuracy | ±1% of full scale |
| Power Supply | Integrated rechargeable battery, >6 h runtime |
| Operating Temperature | 10–45 °C |
| Detection Principle | Flame Ionization Detection (FID) with capillary column separation |
| Sample Path | Fully heated from inlet to detector (up to 220 °C) |
| Connectivity | Industrial-grade Wi-Fi, USB, Ethernet, optional thermal printer interface |
| Compliance | Designed for field deployment in accordance with EPA Method 25A, ASTM D6348, and ISO 11843-2 for trace hydrocarbon quantification |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | TB-2 |
| Price Range | USD 140–700 (FOB) |
| Instrument Type | TLC Scanner Accessory |
| Wavelength Range | 190–700 nm (multi-band selectable) |
| Calibration Wavelengths | UV 254 nm, UV 365 nm, and White Light |
| Plate Size Capacity | 50 × 50 mm to 200 × 200 mm |
| Adjustability | Horizontal Leveling ±0.1°, Width Adjustment Range: 50–220 mm |
| Construction | Anodized Aluminum Frame with Tempered Glass Doors & Stainless Steel Shelves |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose (Benzene-Series & TVOC Analysis) |
| Oven Temperature Range | 5°C above ambient to 400°C |
| Oven Ramp Rate | 0.1–39°C/min |
| Oven Cooling Rate | 50°C/min |
| Injector Maximum Operating Temperature | 400°C |
| Detector | Photoionization Detector (PID) |
| Benzene LOD | 1 ppb |
| Flow Monitoring | Digital Electronic Pressure & Flow Display |
| Software | TVOC-Specific Reverse-Controlled Workstation with Automated Quantitation & Reporting |