Chromatography Instruments
Filter
Showing 1201–1230 of 1564 results
| Brand | Shine |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultra-High-Performance Liquid Chromatograph (UHPLC) |
| Flow Rate Range | 0.001–10.000 mL/min |
| Maximum Pressure | 700 bar (standard), 1000 bar (optional high-pressure configuration) |
| Autosampler Capacity | 768-well microplate or 108-position 2 mL vial tray |
| Column Oven Temperature Range | 5–85 °C |
| UV-Vis Detection Wavelength Range | 190–1000 nm |
| Data Acquisition Rate | 50–100 Hz |
| Gradient Formation Options | Isocratic, Binary High-Pressure, Quaternary Low-Pressure |
| Pump Head Options | Interchangeable 5 mL, 10 mL, and 50 mL heads |
| Detector Options | UV/VIS, Diode Array Detector (DAD), Refractive Index Detector (RID) with Intelligent Temperature Control |
| System Architecture | Modular, Front-Access Design for Maintenance |
| Brand | Shine |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Conventional HPLC System |
| Flow Rate Range | 0.001–10.000 mL/min |
| Maximum Pressure | 42 MPa |
| Flow Accuracy | ≤0.06% RSD (ASTM D7507) |
| Autosampler Capacity | 120 positions |
| Injection Volume Range | 10–500 µL |
| Column Oven Temperature Range | Ambient +5°C to 65°C |
| UV-Vis Detection Wavelength Range | 190–800 nm |
| Data Acquisition Rate | 100 Hz |
| Brand | Shine |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | SH-CIC3200 |
| Instrument Type | Online Analyzer |
| Pump Pressure Rating | 0–35 MPa |
| Flow Rate Range | 0–9.999 mL/min |
| Eluent Flow Rate | 0.1–5.0 mL/min |
| Maximum Operating Pressure | 35 MPa |
| Operating Temperature Range | Ambient +5°C to 60°C |
| Temperature Reproducibility | ±0.2°C |
| Eluent Concentration Range | 0.1–100 mM |
| Brand | Shine |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | SH-GIC7000 |
| Instrument Type | Online Analyzer |
| Application Specificity | Dedicated for Ambient Air Particulate Analysis |
| Pump Pressure Range | 0–35 MPa |
| Flow Rate Range | 0–9.999 mL/min |
| Eluent Flow Rate | 0.1–5.0 mL/min |
| Maximum Operating Pressure | 35 MPa |
| Operating Temperature Range | Room Temperature +5°C to 60°C |
| Temperature Reproducibility | ±0.2°C |
| Eluent Concentration Range | 0–100 mM |
| Brand | Shine |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | SH-WIC5000 |
| Instrument Type | Online Analyzer |
| Application Specificity | Dedicated for Water Matrix |
| Maximum Pump Pressure | 35 MPa |
| Flow Rate Range | 0–9.999 mL/min |
| Eluent Flow Rate | 0.1–5 mL/min |
| Maximum Operating Pressure | 35 MPa |
| Operating Temperature Range | Ambient +5 °C to 60 °C |
| Temperature Reproducibility | ±0.2 °C |
| Eluent Concentration Range | 0–100 mM |
| Detection Limits | 0.5 µg/L (as Cl⁻) |
| Brand | ShineCIC |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | CIC-D200E |
| Instrument Type | Laboratory Benchtop Ion Chromatograph |
| Application Specificity | Dedicated for Carbohydrate (Monosaccharide, Disaccharide, Polyol) Analysis |
| Auto-sampler Capacity | 60 or 120 positions |
| Injection Modes | Full-loop, Partial-loop, and Non-destructive (Needle-in-loop) |
| Detection Principle | Pulsed Amperometric Detection (PAD) with Triple-mode Electrochemical Control (DC, Pulsed, Integrated) |
| Column Oven Integration | Built-in, Temperature-Controlled (30–60 °C, ±0.1 °C stability) |
| Gradient Pump | Multi-channel High-Pressure Mixing System, Max Pressure: 41.4 MPa (6000 psi), pH Tolerance: 0–14, Compatible with Organic Solvents (e.g., Acetonitrile, Methanol, Ethanol) |
| Brand | Shinsco |
|---|---|
| Model | GC-7820 |
| Type | Dual-Valve, Dual-Column, Dual-FID Gas Chromatograph for LPG Hydrocarbon & Oxygenate Analysis |
| Origin | Shandong, China |
| Manufacturer | Shinsco Instrument Co., Ltd. |
| Compliance | GB/T 5274, GB 11174, GB/T 12576, GB 19159, SH/T 0233 |
| Column Configuration | Al₂O₃ PLOT (30 m × 0.53 mm, 15 µm) + Low-Ox (10 m × 0.53 mm, 10 µm) |
| Carrier Gas | Ultra-High-Purity Helium (≥99.999%) |
| Injection | Split Mode (10:1–50:1, recommended 50:1) |
| Oven Program | 90°C (1 min) → 6°C/min → 180°C (30 min) |
| Valve Oven Temp | 150°C |
| Injector Temp | 200°C |
| Dual FID Temp | 230°C |
| H₂ Flow | 30 mL/min |
| Air Flow | 350 mL/min |
| N₂ Make-up | 25 mL/min |
| Quantitation Loop | 0.5–1.0 mL (recommended 0.5 mL) |
| Detection Range | Methane (0.01–1%), Ethane (0.01–3%), Ethylene (0.01–3%), Propane (0.05–95%), Propylene (0.01–95%), i-Butane (0.05–80%), n-Butane (0.02–99%), trans-2-Butene (0.01–40%), Isobutylene (0.01–3%), 1-Pentene (0.01–0.5%), Dimethyl Ether (1.0–40%) |
| Brand | Shinsco |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Model | GCS-60 |
| Detector Type | Flame Photometric Detector (FPD) |
| Measurement Range | 50 ppb – 0.1% (v/v) |
| Accuracy | ±5% for major components, ±10% for trace components |
| Output Signal | 4–20 mA |
| Communication | RS232 / RS485 (Modbus RTU) |
| Dimensions | 800 × 700 × 1900 mm |
| Weight | 170 kg |
| Power Requirement | 5 kW (increases with heated sample line length) |
| Operating Temperature | 5–45 °C |
| Operating Humidity | 5–95% RH |
| Compliance Standard | GB/T 28727–2012 |
| Brand | Elite |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model Series | Shodex |
| Pricing | Available Upon Request |
| Brand | ShoLyn |
|---|---|
| Model | ShoDetec-UV |
| Instrument Type | Thin-Layer Chromatography (TLC) Imaging System |
| Operation Mode | Manual |
| Wavelength Options | 254 nm, 365 nm |
| Light Source | High-Stability UV LED |
| Spectral Bandwidth | 12.2 nm |
| Wavelength Accuracy | ±2.7 nm |
| Wavelength Repeatability | <0.2 nm |
| Imaging Area | 50 × 70 mm |
| Camera Resolution | 5 MP fixed-focus |
| Display | 2.83-inch TFT (480 × 640) |
| Onboard Storage | 16 GB |
| Connectivity | USB-C, microSD card slot, optional Wi-Fi module |
| Power | Rechargeable 2500 mAh Li-ion battery |
| Working Distance (Depth of Field) | 5 cm |
| Rf Calculation Support | Yes |
| Brand | ShoLyn |
|---|---|
| Origin | Shanghai, China |
| Model | ShoDetec-UVE |
| Instrument Type | TLC Imaging System |
| Operation Mode | Manual |
| Wavelength Selection | Manual Dual-Band Switching |
| Wavelengths | 254 nm, 365 nm |
| Light Source | High-Intensity UV LED |
| Spectral Bandwidth | 18 nm |
| Wavelength Accuracy | ±5 nm |
| Imaging Wavelengths | 254 nm, 365 nm |
| Sample Platform | Accommodates 200 × 200 mm preparative silica gel plates and standard TLC plates (e.g., 20 × 50 mm) |
| UV Output Power | 6 W at 254 nm |
| LED Lifetime | >10,000 h |
| Built-in Rechargeable Battery | 5000 mAh |
| Viewing Area | Up to 200 × 200 mm with integrated UV-blocking filter |
| Brand | ShoLyn |
|---|---|
| Origin | Shanghai, China |
| Model | ShoDetec-UVW |
| Instrument Type | TLC Imaging System |
| Operation Mode | Manual |
| Imaging Wavelengths | 254 nm, 365 nm |
| Light Source | High-Stability UV LED (2 W per channel) |
| Spectral Bandwidth | 12.2 nm |
| Wavelength Accuracy | ±2.7 nm |
| Wavelength Repeatability | <0.2 nm |
| Sample Stage Capacity | Max. 50 × 70 mm TLC plate |
| Camera Resolution | 5 MP fixed-focus CMOS sensor |
| Display | 2.83″ TFT LCD (480 × 640) |
| Onboard Storage | 16 GB internal flash |
| Connectivity | USB-C port, microSD slot, Wi-Fi 802.11 b/g/n |
| Image Transfer Modes | USB, microSD readout, Wi-Fi upload |
| RF Calculation Support | Yes |
| Working Distance (Depth of Field) | 5 cm |
| Battery Capacity | 2500 mAh rechargeable Li-ion |
| Brand | SilcoTek |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | SilcoNert2000 |
| Pricing | Available Upon Request |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Manufacture | China |
| Model | GC5400 |
| Application Scope | General-purpose analytical chromatography |
| Brand | Skyray Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Classification | Domestic (China) |
| Model | LC-310 |
| Price Range | USD 14,000–28,000 |
| Instrument Type | Conventional HPLC System |
| Flow Rate Range | 0–10 mL/min |
| Maximum Operating Pressure | 42 MPa |
| Sample Vial Capacity | 108 positions (2 mL vials) |
| Injection Volume Range | 0–20 µL |
| Column Oven Temperature Range | Ambient +5°C to 80°C |
| UV-Vis Wavelength Range | 190–680 nm |
| Data Acquisition Frequency | 50 Hz |
| Brand | Skyray Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | TIC-600 |
| Price Range | USD 14,000 – 28,000 |
| Instrument Type | Benchtop Laboratory System |
| Maximum Pump Pressure | 42 MPa |
| Flow Rate Range | 0–10 mL/min |
| Eluent Flow Rate Range | 0–10 mL/min |
| Maximum Operating Pressure | 42 MPa |
| Operating Temperature Range | 5–60 °C |
| Temperature Stability | ≤ 0.2 °C/h |
| Eluent Concentration Range | 0–40 mmol/L (Na₂CO₃/NaHCO₃) |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | TIC-660 |
| Instrument Type | Laboratory Benchtop |
| Application Scope | Universal Multi-Analyte Ion Analysis |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic Laboratory Ion Chromatograph |
| Model | TIC-680 |
| Configuration | Benchtop Dual-Channel IC System with Electrolytic Eluent Generator and Multi-Detector Compatibility |
| Intended Use | General-purpose anion/cation analysis, speciation coupling (AFS/ICP/ICP-MS), and regulatory-compliant water testing per GB 5750.10–2023 |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Category | Domestic (PRC) |
| Model | UPY-100 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-purpose RoHS Compliance Testing |
| Oven Temperature Range | Ambient +4 °C to 450 °C |
| Oven Ramp Rate | 0–120 °C/min |
| Oven Cooling Rate | <10 min from 350 °C to 50 °C |
| Carrier Gas Flow Range & Control | 0–1250 mL/min, Electronic Flow Control (EFC) |
| Carrier Gas Pressure Range & Control | 0–100 psi, Electronic Pressure Control (EPC) at Column Inlet |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–100 psi |
| Injector Total Flow Setting Range | 0–1250 mL/min |
| Brand | SofTA |
|---|---|
| Origin | USA |
| Model | UM3000 |
| Detection Principle | Evaporative Light Scattering |
| Light Source | 650 nm Laser Diode |
| Detector | Photomultiplier Tube (PMT) |
| Evaporation Zone Temp Range | Ambient to 130 °C |
| Nebulizer Tube Temp Range | Ambient to 80 °C |
| Temp Control Increment | 1 °C |
| Temp Accuracy | ±1 °C |
| Mobile Phase Flow Rate | 10 µL/min to 3 mL/min |
| Carrier Gas | Nitrogen or Compressed Air |
| Gas Input Pressure | 2–5 bar |
| Gas Pressure Measurement Accuracy | 0.01 bar |
| Gas Consumption | 1–4 L/min |
| Detection Limit | <1 ng (glucose, direct injection) |
| Typical Quantitation Range | 0.2–10 µg (glucose, HPLC) |
| Noise Level | <0.1 mV (at 1 mL/min) |
| Signal Output | 0–10 mV DC or 0–1 V DC |
| Interface | RS232 |
| Detection Angle | 120° |
| Display | LCD |
| Operating Environment | 15–35 °C, RH <90% |
| Power Supply | 220 VAC, 50 Hz |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | 50-0.22 |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Lanbo |
| Pricing | Available Upon Request |
| Brand | SOPOTOP |
|---|---|
| Origin | Shanghai, China |
| Model | LC1620A |
| Instrument Type | Conventional High-Performance Liquid Chromatograph (HPLC) |
| Flow Rate Range | 0.001–9.999 mL/min |
| Maximum Operating Pressure | 45 MPa |
| Autosampler Capacity | Up to 120 positions |
| Injection Volume Range | 0.1–120 μL |
| Column Oven Temperature Range | Ambient +5°C to 100°C |
| UV Detector Wavelength Range | 190–700 nm |
| Data Acquisition Frequency | 1 Hz |
| Flow Accuracy | ≤±0.5% (at 1 mL/min, water) |
| Flow Precision (RSD) | ≤0.08% (at 1 mL/min, water) |
| UV Wavelength Accuracy | ±1 nm |
| UV Wavelength Repeatability | 0.1 nm |
| Baseline Noise | ≤±0.8×10⁻⁵ AU |
| Baseline Drift | ≤1×10⁻⁴ AU/h |
| LOD (UV) | 0.4×10⁻⁸ g/mL (naphthalene in methanol) |
| Linear Dynamic Range (UV) | ≥10⁴ |
| RI Detector Refractive Index Range | 1.00–1.75 |
| ELSD Evaporator Temp Range | Ambient to 130°C |
| ELSD Detection Limit | <1 ng (glucose, direct injection) |
| Autosampler Precision (RSD) | <0.5% |
| Carryover | <0.01% |
| Brand | Soptop |
|---|---|
| Origin | Shanghai, China |
| Model | GC1120 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | 7 °C above ambient to 400 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Cooling Rate | ~10 min from 300 °C to 50 °C |
| Carrier Gas Flow Range | 0–1200 mL/min |
| Carrier Gas Pressure Range | 0–900 kPa |
| Injector Maximum Temperature | 400 °C |
| Injector Pressure Setting Range | 0–900 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Temperature Program | 8-stage ramping |
| Isothermal Hold Time | 0–655 min |
| FID Sensitivity | ≤8×10⁻¹² g/s (C₁₆) |
| TCD Sensitivity | ≥5000 mV·mL/mg (C₁₆) |
| ECD Detection Limit | ≤1×10⁻¹³ g/mL (γ-BHC) |
| FPD Detection Limit | ≤1×10⁻¹¹ g/s (P), ≤1×10⁻¹⁰ g/s (S) |
| NPD Detection Limit | ≤5×10⁻¹² g/s (N), ≤5×10⁻¹³ g/s (P) |
| PID Detection Limit | ≤1 ppb (benzene) |
| Maximum PID Operating Temperature | 350 °C |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | SP-2020 |
| Instrument Type | Online Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | Up to 400 °C |
| Temperature Ramp Rate | 0.1–50 °C/min |
| Oven Cooling Rate | 0.1–50 °C/min |
| Carrier Gas Flow Control Range | 0–600 kPa |
| Carrier Gas Pressure Control Range | 0–600 kPa |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–600 kPa |
| Injector Total Flow Setting Range | 0–100 / 200 / 500 mL/min (selectable) |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | SP-2100A |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | 20 °C to 400 °C |
| Ramp Rate | 0.1–40 °C/min |
| Cool-Down Rate | 400 °C → 20 °C |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setpoint Range | 0–970 kPa |
| Injector Total Flow Setpoint Range | 0–1200 mL/min |
| Detector Options | TCD, FID, ECD, FPD |
| TCD Sensitivity | ≥5000 mV·mL/mg n-C₁₆ |
| FID Detection Limit | ≤1×10⁻¹¹ g/s |
| ECD Detection Limit | ≤4×10⁻¹³ g/s (α-HCH) |
| FPD [P] Detection Limit | ≤5×10⁻¹² g/s (parathion) |
| FPD [S] Detection Limit | ≤1×10⁻¹⁰ g/s (parathion) |
| Column Oven Programmable Steps | 5-stage ramp |
| Injector Configurations | Dual packed-column injectors + 1 capillary injector |
| Power Supply | AC 220 V ±10%, 50 Hz ±0.5 Hz, 15 A |
| Dimensions (W×D×H) | 445 × 550 × 560 mm |
| Net Weight | ~38 kg |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Origin | Domestic (China) |
| Model | SP-3400 |
| Instrument Type | Online Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | 4°C to 450°C |
| Oven Ramp Rate | 0.1–39°C/min |
| Oven Cooling Time | ~6 min (from 450°C to 50°C) |
| Carrier Gas Flow Range & Control | 0.1–1200 mL/min |
| Carrier Gas Pressure Range & Control | ±0.05 kPa |
| Injector Maximum Operating Temperature | 450°C |
| Injector Pressure Setting Range | ±0.05 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Detector Options | TCD, FID, ECD, FPD, TSD |
| Injector Types | Packed Column Injector, Split/Splitless Capillary Injector |
| Method Storage Capacity | 4 methods |
| Key Features | Real-time self-diagnosis, programmable detector range/attenuation, automated valve & signal switching, multi-safety interlocks (TCD flow failure, overtemperature, FPD light leakage), microprocessor-based full-keyboard interface |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | SP-I |
| Instrument Category | TLC Sample Spotter |
| Spotting Uniformity | < 0.2 mm |
| Maximum Plate Size | 200 mm × 200 mm |
| Spotting Mechanism | Capillary or Microsyringe-Based Manual Deposition |
| Plate Protection Feature | Non-penetrating Tip Design |
| Compliance | Designed for GLP-aligned manual sample preparation workflows |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | SP6900 |
| Pricing | Available Upon Request |
| Temperature Control | 5-Channel Independent Zones |
| Oven Temperature Range | Ambient +15°C to 399°C |
| Temperature Accuracy | Better than ±0.1°C |
| Ramp Rate | 0.1–40°C/min |
| Programmed Temperature Steps | Up to 5 stages |
| Hold Time Range | 0–255 min per step |
| TCD Detector Sensitivity | ≥3500 mV·mL/mg |
| Baseline Noise | ≤0.02 mV |
| Drift | <0.1 mV/h |
| Instrument Weight | ~60 kg |
| Sample Introduction | Six-Port Rotary Valve |
| Data Output | Real-time digital display of LPG composition and purity via integrated PC software |
| Brand | Spark Holland |
|---|---|
| Origin | Netherlands |
| Model | UHPLC Spark |
| Instrument Type | Ultra-High-Performance Liquid Chromatography–Online Solid-Phase Extraction (UHPLC–SPE) System |
| Flow Rate Range | 1–4000 µL/min |
| Maximum Pressure | 18,850 psi |
| Flow Precision | ≤ 0.075 % RSD (at 200–2000 µL/min) |
| Flow Accuracy | ±1 % (at 200–2000 µL/min) |
| Sample Tray Capacity | 96 positions × 1.5 mL vials |
| Injection Volume Range | 1–10,000 µL |
| Column Oven Temperature Range | 5–90 °C |
| UV-Vis Detector Wavelength Range | 190–700 nm |
| Data Acquisition Rate | 100 Hz |