Combustion Analyzer
Filter
Showing 241–270 of 280 results
| Origin | Tianjin, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | Plastic Oxygen Index Tester |
| Price | USD 145 (approx.) |
| Gas Flow Total | 10.6 L/min |
| O₂ Concentration Range | 0–100% |
| Resolution | 0.1% |
| Accuracy | ±0.1% |
| Response Time | <3 s |
| O₂ Adjustment Step | 0.2% (v/v) |
| Sensor Type | External Electrochemical O₂ Sensor |
| Display | Digital Concentration Meter (O₂%, N₂ flow, total flow) |
| Standards Compliance | GB/T 2406, GB/T 10707, GB/T 5454, ASTM D2863, ISO 4589-2, BS 2782-1:141, NF T51-071 |
| Brand | Peiyi |
|---|---|
| Origin | Shanghai, China |
| Model | PY-NS01 |
| Ignition Source | Liquefied Petroleum Gas (LPG) or Town Gas |
| Burner Inner Diameter | 9.5 ± 0.5 mm, Length: ~100 mm |
| Adjustable Flame Height | 20–100 mm |
| Flame Application Time Range | 0–99 min 99 sec |
| Chamber Volume | 0.05 m³ |
| Chamber Material | Stainless Steel or Powder-Coated Steel |
| Power Supply | AC 220 V, 50 Hz, 5 A |
| Compliance | GB 8410–2006, FMVSS 302, ISO 3795, ASTM D5132 |
| Brand | Phinix |
|---|---|
| Model | PX03002 |
| Standards Compliance | UL 94 HB/V0/V1/V2/5VA/5VB, IEC 60695-11-10/-11-20, ISO 1210/9770/9773, GB/T 2408/5169.17 |
| Chamber Volume | >0.75 m³ |
| Viewing Window | Large tempered glass, interior illumination ≤20 lux |
| Flame Source | HUMBOLDT Trillium burner (ID 9.5±0.3 mm, ASTM D5025 compliant) |
| Flame Orientation | Motorized 0°/20°/45° adjustment |
| Ignition | High-voltage pulse auto-ignition |
| Gas Control | Imported rotameter + differential pressure sensor + precision pressure regulator + solenoid valve |
| Sample Positioning | Motorized linear stage (horizontal/vertical), software-controlled |
| Control System | PLC + industrial touchscreen HMI |
| Safety Features | Auto gas cutoff after 10 min idle, flame duration alert, real-time V (mm/min) calculation and display |
| Optional | 50W/500W flame calibration kit with ±0.1°C certified thermocouples |
| Power | AC 220 V, 50 Hz, 2 A |
| Dimensions (Upper Cabinet) | 1350×700×1000 mm (W×D×H) |
| (Lower Cabinet) | 1350×700×650 mm |
| Weight | ~70 kg |
| Brand | Phinix |
|---|---|
| Model | PX04006 |
| Combustion Chamber Dimensions | 750(W) × 300(D) × 900(H) mm |
| Control Cabinet Dimensions | 650(W) × 650(D) × 1600(H) mm |
| Power Supply | AC 220 V, 50 Hz, 16 A |
| Weight | ~180 kg |
| Fuel Source | Propane (≥95% purity) |
| Heat Flux Calibration Range | 0–100 kW/m² |
| Heat Flux Accuracy | <±3% |
| Response Time | 0.2 s |
| Emissivity | >0.95 |
| Radiant Heat Source | Nine T150 quartz infrared tubes (13 kW/m² ±4 kW/m²) |
| Convective Heat Source | Two 45°-inclined Meker burners (38 mm outer diameter, 5/16″ inner orifice), 25 kW total output |
| Total Incident Heat Flux | 84 kW/m² ±2 kW/m² |
| Temperature Measurement | OMEGA thermocouples with stainless-steel calibration disk, 0–1100 °C range, 0.1 °C display resolution |
| Cooling System | Integrated chiller (10 L/min flow rate), water-cooled aluminum heat sink plate (340 × 286 mm), portable closed-loop water source |
| Automation | PLC-controlled electromechanical positioning modules for specimen and heat flux sensor actuation |
| Software Platform | NI LabVIEW-based HMI with real-time curve visualization, data logging, audit-trail-enabled reporting, and GLP-compliant export formats |
| Brand | Phoenix |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PX01005 |
| Price Range | USD 4,200 – 7,000 |
| Dimensions | 650(W) × 375(D) × 530(H) mm |
| Power Supply | AC 220 V, 50/60 Hz, 2 A |
| Weight | ~30 kg |
| Required Gas Sources | O₂ ≥99.99%, N₂ ≥99.99%, C₃H₈ ≥95% |
| Oxygen Sensor Type | Paramagnetic |
| Oxygen Measurement Accuracy | ±0.1% vol |
| Control System | PLC + 7″ HMI Touchscreen |
| Optional | PC-based LOI control & data management software |
| Brand | MOTIS |
|---|---|
| Origin | Shanghai, China |
| Model | Polynorme 503 |
| Applicable Standard | NFP 92-503 |
| Test Principle | Radiant Heat + Pilot Flame Ignition |
| Application Scope | Building Materials & Railway Components Combustibility Assessment |
| Compliance | French National Fire Safety Regulations for Construction and High-Speed Rail Infrastructure |
| Brand | PW |
|---|---|
| Model | PW-UL94 |
| Compliance | UL 94 (1997), ASTM D4804-03, ISO 9773:1998 |
| Sample Dimensions | (200 ± 5) mm × (50 ± 1) mm × thickness (min/max required) |
| Flame Application | Two 3-second applications of 20 mm Bunsen burner flame (vertical mode) |
| Specimen Orientation | Vertical (VTM-0/VTM-1/VTM-2) and Horizontal (HB) |
| Ignition Source | Precision-calibrated methane or propane burner with adjustable flow control |
| Chamber Volume | ≥ 0.5 m³ |
| Viewing Window | Heat-resistant borosilicate glass with integrated LED lighting and real-time observation port |
| Safety Features | Automatic gas shutoff, flame failure detection, exhaust interlock, dual-layer door seal, internal temperature monitoring |
| Brand | Peiyi |
|---|---|
| Origin | Shanghai, China |
| Model | PY-LD07 |
| Chamber Volume | ≥0.5 m³ |
| Test Voltage Range | 100–600 V AC |
| Electrode Force | 1.0 N ± 0.05 N |
| Electrode Material | Platinum |
| Droplet Volume | 44–50 drops/cm³ |
| Droplet Height Adjustment | 30–40 mm |
| Droplet Interval | 30 ± 5 s |
| Short-Circuit Current Threshold | ≥0.5 A (cut-off after 2 s) |
| Voltage Drop Limit | ≤10% at 1 A ± 0.1 A |
| Power Supply | AC 220 V / 50 Hz |
| Construction | Stainless Steel & Brass Housing |
| Compliance | IEC 60112, IEC 60335-1, GB/T 4207, GB 4706.1, GB 2099.1, VDE 0620 |
| Brand | Qinji |
|---|---|
| Origin | Shanghai, China |
| Model | RSC-157 |
| Compliance Standards | GB/T 2408, ISO 1210, GB 4609, IEC 60950, UL 94, IEC 707, IEC 695-2-2 |
| Burner Positioning | Motorized vertical adjustment with programmable timing and positional repeatability |
| Gas Leak Detection | Integrated high-sensitivity combustible gas alarm system |
| Flame Application | Manual jog control for burner elevation/depression to precisely set flame-to-specimen distance |
| Exhaust System | Dedicated forced-air exhaust ducting with external venting capability |
| Sample Holders | Dual independent fixtures—horizontal (H) and vertical (V) configurations |
| Test Mode Switching | Toggle switch for rapid, tool-free transition between horizontal and vertical flame exposure protocols |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | QUICK 1 |
| Pricing | Upon Request |
| Thermal Conductivity Range (VIP samples) | 0.001–0.015 W/(m·K) |
| Thermal Conductivity Range (Homogeneous samples) | 0.03–10.0 W/(m·K) |
| Repeatability (VIP) | ±5% or ±0.001 W/(m·K), whichever is greater |
| Repeatability (Homogeneous) | ±5% |
| Accuracy | Traceable to NIST-traceable reference standards |
| Operating Temperature | +5 °C to +40 °C |
| Measurement Time | ≤60 s per sample |
| Data Storage Capacity | 99 measurements |
| Power Supply | AC adapter, 100–240 V AC, 50/60 Hz |
| Dimensions | 250 × 200 × 90 mm |
| Weight | 4 kg |
| Brand | R&P |
|---|---|
| Origin | Germany |
| Model | A.21/O.2 Oxidizing Liquids Test Apparatus |
| Compliance | UN Manual of Tests and Criteria, Rev. 4 |
| Pressure Range | 690–2070 kPa (0–500 psi) |
| Response Time | <5 ms |
| Sensor Accuracy | ±0.2% FS |
| Ignition Wire | NiCr, 25 cm × 0.6 mm, 3.85 Ω/m |
| Burst Disc | Aluminum, 0.2 mm thick, burst pressure ≈ 320 psi |
| Power Supply | 10 A / 16 V constant current |
| Data Acquisition | Digital storage oscilloscope with PC interface and printer output |
| Remote Ignition Distance | ≥2 m |
| Enclosure | Stainless steel box-type support frame |
| Brand | FTT |
|---|---|
| Origin | United Kingdom |
| Model | Radiant Panel Flame Spread Apparatus |
| Compliance Standards | ASTM E162, ASTM D3675 |
| Radiation Panel Dimensions | 12 in × 18 in (305 mm × 457 mm) |
| Panel Material | Porous cement and cast iron |
| Ignition System | Electronic spark igniter with auto-shutdown safety monitoring |
| Sample Holder | Stainless steel, calibrated at 3-inch (76 mm) intervals for flame front observation |
| Thermocouple Array | Eight calibrated stainless steel thermocouples integrated into exhaust duct |
| Surface Temperature Measurement | Calibrated high-temperature pyrometer with mounting fixture |
| Gas Control | Precision methane flowmeter and adjustable gas mixture valve |
| Exhaust System | Removable-panel stainless steel ducting for maintenance access |
| Safety Systems | Interlocked gas shutoff valve and circuit-breaker activated by flame failure or overtemperature |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | Relia-Burn |
| Pricing | Available Upon Request |
| Origin | Tianjin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | Relia-Burn |
| Price | USD 1,420 (FOB Tianjin) |
| Compliance | ISO 6940/6941/10047/15025, BS 5438/5722/EN 1103/13772, EN 71-2, GB/T 8745/8746/5456, AS 2755.1–3 |
| Flame Source | Adjustable butane/propane burner (0–600 W), electric spark ignition |
| Radiator | 500 W Epiradiator (120 mm Ø quartz disc) |
| Test Chamber Volume | ≥ 4 m³ |
| Positioning Accuracy | ±0.18° (burner angle), stepper motor–driven linear & rotational motion |
| Control System | Siemens HMI + PLC with preloaded test protocols |
| Sample Mounting | 8 standardized needle frames + stainless steel specimen clamps |
| Safety | Floor-standing design, external operation mode, 180° rotatable support arm, 360° rotatable touchscreen |
| Brand | SDL Atlas |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | M233G |
| Price Range | USD 14,000 – 28,000 |
| Application Field | Textiles & Home Furnishings |
| Test Angle | 45° |
| Flame Exposure Duration Options | 1 s, 5 s, 20 s |
| Timing Resolution | 0.1 s |
| Construction | Stainless Steel Chamber with Tempered Glass Viewing Window |
| Optional Accessory | Nylon Brush Kit |
| Brand | SDL Atlas |
|---|---|
| Model | M233M |
| Test Orientation | Vertical |
| Construction | Stainless Steel Combustion Chamber with Tempered Glass Viewing Window |
| Burner Type | Standard ASTM/ISO-Compliant Bunsen Burner |
| Gas Control | Manual or Optional Electromagnetic Solenoid Valve with Auto-Ignition and Timer Control |
| Sample Holder | Interchangeable Fixtures per Standard (e.g., ASTM D6413, ISO 6941, GB/T 5455, NFPA 701) |
| Compliance | Designed for Textile and Home Furnishing Flammability Testing |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Setchkin |
| Pricing | Available Upon Request |
| Brand | MOTIS |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | SPI |
| Pricing | Upon Request |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | SR613 |
| Pricing | Available Upon Request |
| Brand | MOTIS |
|---|---|
| Model | STF |
| Standard Compliance | UL 910 / NFPA 262 |
| Chamber Construction | Stainless Steel (304) with Refractory Brick Lining |
| Observation Window | Dual-Layer Quartz Glass |
| Flame Propagation Monitoring | LED Indicator Strip System |
| Smoke Seal | 2 mm 304 Stainless Steel Water-Tight Trough |
| Exhaust Fan | 3 kW, 380 V / 50 Hz, Variable-Frequency Drive, ≥8000 m³/h Capacity |
| Burner | Dual-Orifice Copper Burner, Heat Output Adjustable from 5.3 MJ/min (UL 910 baseline) up to 100 MJ/min via Mass Flow Control |
| Ignition System | High-Voltage Spark Igniter (44 kV / 50 mA, Minimum Electrode Voltage 1.8 kVp) |
| Pressure Monitoring | Differential Pressure Sensor, Range 0–250 Pa, Accuracy ±0.5 Pa (System Accuracy ±2 Pa) |
| Temperature & Smoke Signal Acquisition | 1 Hz Sampling Rate, Linearized Photometric Smoke Density Detection |
| Gas Control | 316 Stainless Steel Mass Flow Controller, Propane Range 0–2.3 g/s, Accuracy ±1% FS (0.6–2.3 g/s), Repeatability ±0.5% FS, NIST-Traceable Calibration |
| Software | Integrated Test Management Platform with Real-Time Logging of Airflow Velocity, Chamber Temperature, Optical Density, and Fuel Consumption |
| Auxiliary Systems | Municipal Water Supply Interface, Methane Gas Delivery Subsystem, Overhead Hoist for Sample Handling |
| Sample Mounting | Stepped Access Platform with Integrated Support for Calcium Silicate Cover Boards |
| Thermal Insulation | High-Temperature Ceramic Fiber Blanket within 304 Stainless Enclosure |
| Application Domain | Horizontal Cable Tray Fire Propagation Testing per UL 910/NFPA 262 for Plenum-Rated Communications Cables |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Classification | Domestic (China) |
| Model | TAI |
| Pricing | Upon Request |
| Brand | TESTech |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Model | TTech-GBT14402 |
| Standard Compliance | GB/T 14402-2007, GB 8624-2012, ISO 1716:2002 |
| Oxygen Bomb Capacity | (300 ± 50) mL |
| Maximum Oxygen Pressure | 3.5 MPa |
| Burst Pressure Rating | 21 MPa |
| Crucible Dimensions | Φ25 mm × (14–19) mm (stainless steel, 1 mm wall thickness) |
| Stirring Power | 3 W |
| Stirring Speed | 375 rpm (inner bucket) |
| Temperature Measurement Range | 4.5–50 °C |
| Temperature Resolution | 0.0001 °C (PT100 sensor) |
| Inner Bucket Volume | 2000 mL |
| Calorimeter Heat Capacity | ~10,000 J/K |
| Heat Capacity Repeatability Error | ≤0.2% |
| Timer Accuracy | ±0.5 s |
| Operating Ambient | 10–35 °C, RH ≤80% |
| Max Power Consumption | 0.5 kW |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Brand | TESTech |
|---|---|
| Model | TTech-GBT18380B |
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Compliance Standards | GB/T 18380.31–36, IEC 60332-3-10, UL 1685, EN 50399, KS C IEC 60332-3-21 to -25 (Classes A–D), IEEE 383 (with 20° burner tilt option) |
| Test Chamber Dimensions | 1,000 ± 100 (W) × 2,000 ± 100 (D) × 4,000 ± 100 (H) mm |
| Airflow Rate | (5,000 ± 500) L/min |
| Propane Burner | 257 mm × 4.5 mm ribbon-type, 242 × Ø1.35 mm orifices in triple-row configuration (81/80/81), 3.2 mm pitch |
| Gas Supply | Technical-grade propane (≥95% purity), regulated at 100 kPa @ 20 °C |
| Ignition | Automatic spark ignition |
| Control System | PLC-based with 10.1″ industrial touchscreen HMI |
| Timing Resolution | 1 s, max duration 999 min |
| Thermocouple | K-type armored, Ø2 mm |
| Inlet Opening | 800 ± 20 (W) × 400 ± 10 (D) mm, located 150 ± 10 mm from front panel |
| Exhaust Duct | Stainless steel, integrated with optional gas analysis interface for HRR & SPR measurement |
| Brand | TESTech |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TTech-GBT9775 |
| Price | Upon Request |
| Power Supply | AC 220 V ±10 V, 50 Hz |
| Fuel Source | Liquefied Petroleum Gas (LPG) or Town Gas |
| Flame Length Range | 10–100 mm |
| Flame Application Time | 0–999.9 s |
| Timing Accuracy | ±0.1 s |
| Temperature Range | Ambient to 1000 °C (Class 0.5 accuracy) |
| Temperature Stabilization | >3 min at 800 ±30 °C |
| Burner Inner Diameter | Φ9.5 ±0.5 mm, Length ≈100 mm |
| Chamber Dimensions (L×W×H) | 0.7 × 0.4 × 0.72 m |
| Weight | 25 kg |
| Brand | TESTech |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TTech-ISO5658 |
| Pricing | Upon Request |
| Brand | TESTech |
|---|---|
| Model | TTech-NFP92 |
| Origin | Jiangsu, China |
| Manufacturer | TESTech (OEM/ODM Producer) |
| Compliance | NF P 92-505, EU Directive 95/28/EC, ECE R118 Annex 7 |
| Radiation Aperture | 100 mm ± 5 mm |
| Radiant Flux at 30 mm Below Aperture | 3 W/cm² |
| Sample Holder Inner Diameter | 118 mm |
| Drip Collection Pan | 118 mm ID × 12 mm depth, lined with cotton wadding |
| Power Supply | 220 V AC, 50 Hz |
| Footprint | 425 mm × 300 mm |
| Max Height | 680 mm |
| Weight | 13 kg |
| Brand | TESTech |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Model | TTech-UL2596 |
| Compliance Standard | UL 2596–2023 |
| Flame Temperature | Up to 1200 °C |
| Flame Power Output | 3 kW |
| Grit Feed Rate | 1.5 g/s ±10% |
| Test Cycle Modes | 15 s flame only |
| Control Interface | PC-based LabVIEW software + industrial touchscreen HMI |
| Gas Flow Control | Mass flow controllers for fuel gas and oxygen |
| Grit Air Flow Control | Mass flow controller |
| Frame Dimensions | 1200 mm × 500 mm × 1500 mm (W×D×H) |
| Burner Nozzle Diameter | 28.6 mm |
| Integrated Fireproof Baffle | Stainless steel + ceramic fiber, slide-in replaceable design |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | testo 327-1 |
| Pricing | Available Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | EN 367 |
| Pricing | Upon Request |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | UIC-5 |
| Pricing | Available Upon Request |
