| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Model | CTA |
| Air Flow Range | 0–3 L/min (digital display, ±0.1 L/min resolution) |
| Temperature Control | Dual-mode PID (programmable ramp & single-point setpoint) |
| Max Furnace Temp | 1100 °C with over-temperature cutoff |
| Furnace Type | Openable quartz tube furnace with imported thermocouple-based heating system |
| Auxiliary Instruments | Magnetic stirrer, pH meter, conductivity meter |
| Filtration | Activated carbon + silica gel dual-column air filter |
| Standards Compliance | GB/T 17650.1–2, IEC 60754-1/2:1994, EN 50305, BS 6853 Annex B |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Model | CTA |
| Air Flow Range | 0–3 L/min (digital display, adjustable in 0.1 L/min increments) |
| Temperature Control | Dual-mode PID (programmable ramping and single-point setpoint) |
| Max Furnace Temperature | 1100 °C with over-temperature cutoff |
| Furnace Type | Openable tubular furnace with imported thermocouple-equipped quartz heating tube |
| Auxiliary Instruments | Magnetic stirrer, pH meter, conductivity meter |
| Air Filtration | Activated carbon + silica gel columns |
| Compliance | GB/T 17650.1–2–1998, IEC 60754-1/2–1994, EN 50305, BS 6853 Annex B |
| Brand | MOTIS |
|---|---|
| Origin | Shanghai, China |
| Model | CWFP |
| Applicable Standards | NFC 32-070 (France), UL 2556 |
| Heating Source | Electric Furnace + Dual Butane Burners |
| Sample Mounting | Vertically Suspended Cable |
| Smoke Duct | PTFE-Coated, Rotatable with Three 120° Ventilation Orifices |
| Ignition System | Electric Spark-Ignited Butane Burners with V-Shaped Wind Shield |
| Airflow Control | Variable-Frequency Fan + Adjustable Top-Mounted Damper + Anemometer |
| Calibration | Standard Radiant Rod for Furnace Power Verification |
| Chamber Construction | Integrated Combustion Test Enclosure with Forced-Air Ventilation |
| Compliance Support | Designed for GLP-aligned test execution and traceable calibration protocols |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | FFM |
| Pricing | Available Upon Request |
| Test Standard Compliance | GB/T 16556–2007, EN 136 |
| Simulated Head | Metallic anthropomorphic head (rotatable) |
| Thermocouple | K-type, positioned 250 mm above burner tip, range 950 ± 50 °C |
| Burners | 6 × TEKLU-type adjustable-height burners |
| Gas Flow Control | Mass flow meter with digital display |
| Supply Pressure Range | 10–50 kPa |
| Safety Features | Flame flashback arrestor |
| Dimensions (W×D×H) | 1000 × 650 × 1300 mm |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Model | FPR |
| Standards Compliance | ISO 9239-1, ASTM E648, GB/T 11785 |
| Radiation Panel | 300 mm × 450 mm porous ceramic, mounted at 30° angle |
| Heat Flux Range | 0–50 kW/m² (water-cooled thermopile) |
| Thermopile Accuracy | <2% |
| Response Time | 0.2 s |
| Light Source | Tungsten filament lamp, 2900 ± 100 K |
| Photodetector | Silicon photodiode |
| Smoke Measurement | Transmittance-based optical density (OD), real-time DAQ via 15″ touchscreen PC |
| Air Supply | Integrated variable-frequency blower with Venturi gas-air mixer and flashback arrestor |
| Ignition | Pneumatically actuated T-shaped burner (propane) |
| Safety | Flame-out detection via thermal probe, automatic gas shutoff |
| Calibration | Motorized lift stage for thermopile positioning |
| Sample Holders | 3 stainless steel fixtures |
| Temperature Monitoring | Chimney thermocouple, chamber thermocouple, infrared radiometer for panel surface temperature |
| Software | Dedicated DAQ platform with synchronized heat flux, smoke density, transmittance, airflow, and time-stamped flame spread tracking |
| Brand | MOTIS |
|---|---|
| Origin | Shanghai, China |
| Model | FPT |
| Compliance | BS 476-6:2009+A1:2009 |
| Heating Source | Dual 1000 W quartz radiant heaters + T-type gas burner |
| Power Control | Automated time-programmed output (530 J/s initial → 1800 W at 2 min 45 s → 1500 W at 5 min) |
| Temperature Monitoring | T-type thermocouples measuring ΔT between flue gas and ambient air |
| Data Acquisition | Real-time logging with automated I-index calculation per BS 476-6 Annex B |
| Sample Holders | Three stainless-steel-clad configurations for wall/ceiling linings |
| Combustion Chamber Lining | Calcium silicate board |
| Structural Frame | Stainless steel support chassis |
| Reporting | ASTM/ISO-compliant PDF export with audit trail metadata |
| Brand | MOTIS |
|---|---|
| Model | FRAT |
| Standard Compliance | UL 1685, IEEE 383, IEEE 1202 |
| Chamber Dimensions (L×W×H) | 2600 × 2600 × 3100 mm |
| Internal Volume | 20.28 m³ |
| Floor Area | 6.76 m² |
| Test Duration | 20 min |
| Burner Heat Release Rate | 20 kW (70,000 BTU/hr) |
| Burner Type | Venturi-mixed propane burner per IEC 60332-3 |
| Tray Dimensions | 305 × 76 × 2438 mm |
| Ladder Bar Width | 25 ± 6 mm |
| Ladder Rung Spacing | 229 mm |
| Temperature Monitoring | Thermocouples + bidirectional hot-wire anemometry in exhaust duct |
| Gas Control | Mass flow controller + solenoid valves |
| Data Acquisition | Dedicated DAQ board for flame & structural temperature logging |
| Safety | Manual emergency power cutoff (instrument only, excludes PC) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | FT-45 |
| Pricing | Available Upon Request |
| Brand | MOTIS |
|---|---|
| Origin | Shanghai, China |
| Model | FVT |
| Compliance | GB/T 8333, ASTM D3014a |
| Burner Type | Bunsen burner |
| Maximum Flame Temperature | 900 °C |
| Thermocouple | Manually Positionable |
| Automation | Motorized Burner Translation |
| Flame Height Measurement | Calibrated Steel Scale |
| Gas Flow Control | Adjustable and Auto-Shutoff |
| Chamber Lining | PTFE-Coated Interior |
| Operation Mode | One-Touch Test Initiation |
| Brand | MOTIS |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCF |
| Pricing | Available Upon Request |
| Temperature Control | Programmable controller with standard temperature ramp profile (e.g., BS 8414 Annex A) |
| Test Duration | Up to 24 h continuous monitoring and control |
| Compliance | BS 8414-1:2015, BS 8414-2:2015 (aligned with draft GB/T 39173 under development) |
| Data Acquisition | Real-time display of furnace interior and specimen surface temperatures |
| Thermocouple Configuration | Integrated internal furnace thermocouples + dedicated specimen surface thermocouples |
| Specimen Handling | Freely accessible test chamber with standardized mounting interface for façade system assemblies |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Model | GCF |
| Compliance | GB/T 29416–2012 Annex C, BS 8414 |
| Temperature Control | Programmable controller with standardized temperature ramp profile |
| Test Duration | 24 h continuous monitoring |
| Thermocouple Configuration | Internal furnace thermocouples + surface-mounted sample thermocouples |
| Data Logging | Real-time temperature display and curve plotting |
| Pass/Fail Criteria | Based on thermal trajectory divergence (sample center temperature vs. furnace ambient temperature) |
| Software Functionality | Automated test execution, time-synchronized thermal data acquisition, and smoldering propensity classification per GB/T 29416–2012 |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HFT |
| Price Range | USD 1,400 – 7,000 (FOB) |
| Application Domain | Automotive Interior Materials Testing |
| Compliance | GB 8410, FMVSS 302 |
| Ignition Time Setting | 15 s (automatically terminated) |
| Gas Control | Integrated needle valve and ball valve for precise propane flow regulation and shutoff |
| Sample Holder Options | Two interchangeable specimen holders |
| Specimen Mounting | Right-side insertion design for ergonomic operation |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Model | SFT |
| Compliance | ISO 5658-2, IMO Resolution A.653(16), GB/T 28752-2012 |
| Application Domain | Transportation (Marine, Rail, Automotive Interiors) |
| Radiation Panel Dimensions | 480 mm × 280 mm |
| Calibrated Heat Flux Range | 0–100 kW/m² (via water-cooled calorimeter) |
| Ignition Source | Ceramic-tube burner with propane/air or methane/air mixture |
| Data Acquisition | Thermocouple array (mV output), synchronized video capture, foot-switch-triggered timing |
| Cooling | Portable closed-loop water chiller for calorimeter stabilization |
| Software | PC-based control & analysis platform compliant with GLP audit trail requirements |
| Brand | MOTIS |
|---|---|
| Model | 503 |
| Standard Compliance | NFP 92-503 |
| Heat Flux Source | Calibrated Electric Radiant Panel |
| Flame Application | Fan-shaped Gas Burner |
| Flame Height Control | Rotameter-adjusted to 30 mm |
| Specimen Holder | Stainless Steel Frame with Needle-type Specimen Clamp |
| Test Duration | Programmable Automatic Timer |
| Radiant Heat Monitoring | Copper Disc Calorimeter (1 unit) |
| Construction | Domestic Manufacturing (Jiangsu, China) |
| Distributor Type | Authorized General Distributor |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | MTT |
| Price Range | USD 14,000 – 28,000 |
| Application Field | Construction Materials |
| Compliance Standard | GB/T 20285 “Hazard Classification of Smoke Toxicity from Materials” |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NCF |
| Pricing | Available Upon Request |
| Temperature Control | PID → Constant Power Switching at 750±5°C |
| Max Furnace Temp | 900°C |
| Data Interface | RS-232C with Dedicated Acquisition Card |
| Calibration Compliance | ISO 1182 & GB/T 5464-2010 |
| Reporting | Automated Report Generation & Printing |
| Sensor Suite | Integrated Internal Thermocouple + Scanning Wall Thermocouples |
| Software Functions | In-Furnace & Wall Temperature Calibration Curve Mapping |
| Brand | MOTIS |
|---|---|
| Origin | Shanghai, China |
| Model | NCF |
| Temperature Control | PID + Constant-Power Hybrid Mode |
| Operating Temperature | 750 ± 5 °C |
| Calibration | Dual Thermocouple System (360° Circumferential Wall Scan + Adjustable Internal Probe) |
| Data Interface | RS-232C with Dedicated Acquisition Card |
| Compliance | GB/T 5464–2010, GB 8624–2011 |
| Software | Integrated Calibration Curve Generation, Auto-Judgment Logic, Report Generation & Printing |
| Structural Design | Modular Furnace Assembly for Simplified Maintenance |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Model | NCF |
| Compliance | ISO 1182, GB/T 5464, BS 476-4 & BS 476-11, IMO FTP Code Part 1 |
| Temperature Control Range | 750 ± 5 °C |
| Heating Method | Radiant Tube with Kanthal® Resistance Band |
| Thermocouple Type | OMEGA™ Type K (NiCr-NiAl) |
| Temperature Monitoring Points | Furnace Chamber, Specimen Surface, Specimen Center |
| Calibration Capabilities | 360° Rotatable & Vertically Adjustable Thermocouple Scanning System for Furnace Wall and Internal Temperature Mapping |
| Airflow Stabilization | PTFE-Coated Stainless Steel Inverted Conical Air Stabilizer and Cylindrical Flow Guide |
| Software | Integrated Windows-Based Data Acquisition, Real-Time Curve Plotting, Automated Report Generation (PDF/Excel), ASTM/ISO-Compliant Data Logging with Timestamped Audit Trail |
| Brand | MOTIS |
|---|---|
| Origin | Shanghai, China |
| Model | PFET |
| Compliance | IMO A.753, ISO 19921–1 & 19921–2, ISO 10497, FTP Code Annex 2 (Res. A.753) |
| Test Pressure Range | 0–20 bar |
| Thermal Radiation Sensor | Calibrated heat flux meter (kW/m²) |
| Cooling System | Integrated water-cooled calorimeter mount |
| Temperature Monitoring | Dual K-type thermocouples (0–1200 °C) |
| Sample Positioning | Motorized X-Y-Z adjustable test platform |
| Data Acquisition | PC-based real-time logging software with time-synchronized thermal, pressure, and radiation curves |
| Brand | MOTIS |
|---|---|
| Origin | Shanghai, China |
| Model | Polynorme 505 |
| Compliance | NF P92-505, EU Directive 95/28/EC |
| Radiant Flux | 30 kW/m² |
| Radiation Source | Epiradiator |
| Sample Holder | Adjustable-height stainless steel tray with cotton substrate support |
| Radiation Source Mount | Rotatable 90° stainless steel bracket |
| Power Display | Digital front-panel readout |
| Power Control | Precision radiant flux regulator |
| Height Gauge | Integrated calibratable positioning tool |
| Brand | MOTIS |
|---|---|
| Model | PSS |
| Origin | Shanghai, China |
| Compliance | BS 476-7, BS 6853 |
| Radiant Panel Size | 850 mm × 850 mm |
| Ignition Source | Electric spark igniter |
| Specimen Holder | Water-cooled vertical mount with calibrated scale |
| Heat Flux Sensor | NIST-traceable water-cooled calorimeter |
| Control System | PLC-based HMI with digital heat flux display |
| Safety Interlock | Automatic gas shutoff upon radiant panel flameout |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Model | RFS |
| Standards Compliance | ASTM E162, ASTM E365, ASTM D3675 |
| Radiant Panel Dimensions | 300 × 460 mm |
| Reflector Surface | 305 × 457 mm, Porous Cement |
| Max Reflector Temp | 815 °C |
| Calibration Burner | Methane (95% purity, 20 L/min @ 150 mbar) |
| Pilot Burner | Acetylene (0.5 L/min @ 150 mbar) |
| Propane Burner | 1.0 L/s @ 20 mbar |
| Compressed Air Supply | 50 L/s @ 700 Pa water column |
| Exhaust Airflow Velocity | 0.5 m/s ±0.05 m/s |
| Black-Body Temperature Control Range | 180–230 °C (±5 °C accuracy) |
| Heat Flux Measurement Range | 0–100 kW/m² (±10% full scale, Schmidt-Boelter type) |
| Data Acquisition | GPIB/USB interface DAQ system with 19" touchscreen control unit |
| Frame Dimensions | 1850 H × 700 D × 1250 L mm |
| Electrical Supply | 220 V AC, 60 Hz, 12 A |
| Brand | MOTIS |
|---|---|
| Origin | Shanghai, China |
| Model | RPT |
| Compliance | NF P92-501, TB/T 2639.1 |
| Heat Flux | 30 kW/m² |
| Key Outputs | Ignitability Index (i), Average Flame Height Index (S), Maximum Flame Height Index (h), Combustion Heat Release Index (C) |
| Construction | Stainless Steel Enclosure with Fire-Resistant Lining |
| Viewing Window | Tempered Quartz |
| Test Angle | 45° Inclined Specimen Mount |
| Radiant Source | Epiradiator with Power-Controlled Output |
| Burners | Dual Stainless Steel Burners (Upper & Lower), Pilot Ignition System |
| Flame Control | Adjustable Needle Valves with Height Gauge |
| Gas Shutoff | Quarter-Turn Isolation Valves |
| Temperature Monitoring | Top & Inlet Thermocouples |
| Software | Dedicated Test Suite with Automated Index Calculation, Report Generation & Data Export (CSV/PDF) |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Model | RRT |
| Heating System | 4000 W primary + 2000 W auxiliary electric heating elements with dual PID temperature control |
| Reflector | Stainless steel parabolic reflector |
| Headform | Metallic anthropomorphic headform with adjustable horizontal positioning rail |
| Thermal Flux Measurement | Water-cooled heat flux meter calibrated per ISO 8503-2 |
| Breathing Simulation | Programmable sinusoidal artificial lung (PLC-controlled |
| Failure Detection | Differential pressure sensor for real-time mask seal integrity monitoring |
| Compliance | EN 136:2023, GB/T 16556–2007 |
| Power Supply | 220 V AC, 30 A |
| Dimensions | 1400(W) × 600(D) × 1400(H) mm |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Model | SCF |
| Compliance | ASTM E108, UL 790, NFPA 256, IEC 61730-2 Annex A |
| Test Chamber Dimensions (L×W×H) | 1020 × 1000 × 1473 mm |
| Roof Deck Substrate | Plywood, 1300 × 1000 × 120 mm |
| Non-combustible Backstop Panel | Stainless steel, installed at rear end of test deck |
| Adjustable Fan-shaped Deflector Plate | 1440 × 940 mm, stainless steel, angle-adjustable |
| Eave Simulator Assembly | 330 × 2130 × 584 mm, non-combustible board mounted at front frame |
| Airflow Velocity | 19 ± 8 km/h (5.5 ± 2.2 m/s), monitored via calibrated anemometer |
| Exhaust Duct | Stainless steel, 2130 × 762 × 3000 mm, equipped with honeycomb flow straightener, guide vanes, and adjustable turbulence plates |
| Fan | 220 V, 50 Hz, three-phase, reverse-flow capable, 0–100% infinitely variable speed control, min. airflow 300 m³/min |
| Gas Burner | 1.12 m long × 60.3 mm OD, linear slit (12.7 mm wide × 0.91 m long), heat output Class A/B: 21,000–22,000 Btu/min (369–387 kWh) for 10 min |
| Class C | 18,000–19,000 Btu/min (316–334 kWh) for 4 min |
| Burner Surface Temperature | 880 ± 10 °C |
| Automatic Ignition System | High-voltage electrode ≥1.8 kVp |
| Mass Flow Control | Precision thermal mass flow meters for repeatable gas delivery per test class |
| Data Acquisition | NI-based LabVIEW system with 16-bit thermocouple input, 16-bit analog input, digital I/O, 12-bit analog output, 4/8-slot chassis, real-time & Ethernet modules |
| Sample Support | Rotatable metal mesh tray with load-bearing capacity for standard PV modules (up to 2.0 m length) |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Model | SCF |
| Standards Compliance | ASTM E108, UL 790, NFPA 256, IEC 61730-2 Annex A |
| Test Chamber Dimensions (L×W×H) | 1020 × 1000 × 1473 mm |
| Sample Support Base | 1300 × 1000 × 120 mm Plywood Deck |
| Stainless Steel Fan Duct | 2130 × 762 × 3000 mm |
| Airflow Velocity | 5.5 ± 2.2 m/s (19 ± 8 km/h) |
| Gas Burner Length | 1.12 m, Slot Width: 12.7 mm, Slot Length: 0.91 m |
| Heat Release Rate | Class A/B: 369–387 kWh (21,000–22,000 Btu/min) for 10 min |
| Class C | 316–334 kWh (18,000–19,000 Btu/min) for 4 min |
| Burner Surface Temperature | 880 ± 10 °C |
| Data Acquisition | NI PXI-based LabVIEW system with 16-bit thermocouple input, 16-bit and 12-bit analog I/O modules, real-time & Ethernet communication support |
| Power Supply | 220 V, 50 Hz, 3-phase |
| Minimum Airflow Capacity | 300 m³/min |
| Auto-Ignition Voltage | ≥1.8 kVp |
| Brand | MOTIS |
|---|---|
| Origin | Shanghai, China |
| Model | SC F |
| Compliance Standards | ASTM E108, UL 790, NFPA 256, IEC 61730-2 Annex A |
| Test Chamber Dimensions (L×W×H) | 1020 × 1000 × 1473 mm |
| Test Panel Size | 1300 × 1000 × 120 mm (plywood substrate) |
| Flame Impingement Burner | 1.12 m long × 60.3 mm OD, 12.7 mm × 910 mm slot |
| Heat Release Rate | Class A/B: 21,000–22,000 Btu/min (369–387 kWh) |
| Class C | 18,000–19,000 Btu/min (316–334 kWh) |
| Airflow Velocity | 5.5 ± 2.2 m/s (19 ± 8 km/h) |
| Exhaust Fan Capacity | ≥300 m³/min, variable-speed (0–100%), 220 V / 50 Hz / 3-phase |
| Ignition Voltage | ≥1.8 kVp |
| Burner Surface Temperature | 880 ± 10 °C |
| Data Acquisition | NI-based LabVIEW system with 16-bit thermocouple input, 16-bit and 12-bit analog I/O modules, real-time & Ethernet communication support |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | SCT |
| Pricing | Available Upon Request |
| Brand | MOTIS |
|---|---|
| Origin | Shanghai, China |
| Model | SCV |
| Chamber Dimensions (H×W×D) | 1300 mm × 300 mm × 450 mm |
| Sample Mounting | Dual stainless-steel support rods |
| Burner | 1 kW premixed gas burner (propane/air) |
| Gas Control System | Pressure gauge, pressure-reducing valve, rotameter, shut-off ball valve, and check valve |
| Compliance | IEC 60332-1-1, IEC 60332-1-2, IEC 60332-1-3, EN 50086-1:1994, GB/T 18380.11–2022, GB/T 18380.12–2022 |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | SFT |