| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SIT |
| Pricing | Available Upon Request |
| Compliance | EN ISO 11925-2, DIN 53438, GB/T 8626 |
| Chamber Material | SUS304 Stainless Steel |
| Viewing Windows | Dual Tempered Glass Doors |
| Flame Orientation | Adjustable (Vertical or 45°) |
| Flame Height Control | Rotameter with Calibration Gauge |
| Sample Holder | Dual-Mode (Vertical/Horizontal Translation + 90° Rotation) |
| Sample Fixtures | Standard & Wide Stainless Steel Clamps |
| Ignition Position Options | Center-Line (40 mm above bottom edge) / Edge-Ignition (depth-dependent per thickness) |
| Optional Accessories | 0–10 m/s Anemometer, 0.2 s Resolution Timer |
| Brand | MOTIS |
|---|---|
| Model | SIT |
| Principle | Kleinbrenner small-flame impingement (vertical orientation) |
| Standards Compliance | EN ISO 11925-2, DIN 53438, GB/T 8626, DIN 4102-1 (Class B2) |
| Chamber Construction | Full stainless steel |
| Viewing Windows | Dual tempered glass doors |
| Sample Holder | Adjustable vertical/horizontal positioning |
| Ignition Source | Selectable 0° (vertical) or 45° angle |
| Flame Height Control | Rotameter-regulated propane/air flame |
| Flame Measurement | Integrated calibrated flame gauge |
| Airflow Monitoring | 0–10 m/s anemometer |
| Timing Resolution | 0.2 s |
| Accessories | Annex A sample clamp & template set |
| Sample Fixtures | Two interchangeable stainless steel clamps |
| Origin | Shanghai, China |
| Distribution Type | Authorized distributor |
| Brand | MOTIS |
|---|---|
| Model | TPP |
| Origin | Shanghai, China |
| Compliance | NFPA 1971, ASTM D4018, GB 8965.1–2009, ISO 12749 |
| Heat Source | Dual Meker burners (38 mm, 5/16″ orifice) + 9× T150 quartz IR tubes |
| Total incident heat flux | 83 kW/m² ± 2 kW/m² |
| Radiant flux range | 13–40 kW/m² ± 4 kW/m² |
| Convection source | 800–1200 BTU/h per burner |
| Calibrated water-cooled heat flux sensor | 0–100 kW/m², response <200 ms, emissivity >0.95 |
| Data acquisition | 20 Hz (50 ms interval), 0.1 °C resolution, ±0.75 °C accuracy, cold-junction compensation |
| Gas control | Rotameter (±2% accuracy, >3 L/min), pressure regulator (0–15 psi), quarter-turn shutoff valve |
| Brand | MOTIS |
|---|---|
| Origin | Shanghai, China |
| Model | UIC-4 |
| Standards Compliance | TB/T 3237, UIC 564-2 |
| Sample Holder | Dual stainless-steel clamps with adjustable support stand |
| Ignition System | Electric spark igniter |
| Burner Type | Bunsen burner with 45° and 90° angular adjustment |
| Flame Height Gauge | Integrated calibrated gauge |
| Construction | Stainless-steel frame and combustion chamber components |
| Brand | MOTIS |
|---|---|
| Origin | Shanghai, China |
| Model | UK-1 & UK-2 |
| Compliance | BS 5852:2006, UK Furniture and Furnishings (Fire) (Safety) Regulations 1988 (as amended), CFR 1634 |
| Chamber Dimensions (UK-1) | 450 × 300 × 150 mm |
| Chamber Dimensions (UK-2) | 450 × 450 × 300 mm |
| Construction | Full stainless steel frame and test fixture |
| Ignition Sources | Standard smoldering cigarette (ISO 12403-1), No. 0–No. 7 calibrated ignition sources |
| Included Accessories | Certified standard polyurethane foam (density 25 ± 1 kg/m³), standardized timber crib (ASTM E1321), stainless steel mesh screen (aperture ≤ 1 mm), stainless steel ignition tube, precision-cut stainless steel template for specimen positioning |
| Brand | MOTIS |
|---|---|
| Origin | Shanghai, China |
| Model | UL94-X |
| Chamber Volume | >0.75 m³ |
| Interior Finish | Matte Black |
| Viewing Window | Large Transparent Observation Port |
| Burner Angle Adjustment | 0°, 20°, 45° |
| Ignition Source | Bunsen Burner (ASTM D5025 Compliant) |
| Flame Geometry | Fan-shaped Burner (ASTM D4986 Compliant) |
| Gas Flow Control | Rotameter + High-Precision Pressure Regulator |
| Exhaust System | Top-mounted Forced Ventilation |
| Optional Accessory | Burner Calibration Kit (ASTM D5207 Compliant) |
| Standards Supported | UL 94 HB/V-0/V-1/V-2/5VA/5VB/VTM-0/VTM-1/VTM-2/HF-1/HF-2/HBF |
| Referenced Standards | IEC 60695-11-10, IEC 60695-11-20, ISO 1210, ISO 9770, ISO 9772, ISO 9773, GB/T 2408, GB/T 5169.17, GB/T 8332 |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Model | UL94-X |
| Compliance | UL 94 HB, V0/V1/V2, 5VA/5VB, VTM-0/1/2, HF-1/HF-2/HBF |
| Chamber Volume | ≥0.75 m³ |
| Interior Finish | Matte Black |
| Viewing Window | Extra-Large Transparent Borosilicate Glass |
| Burner Types | Bunsen (ASTM D5025), Fan-Shaped (ASTM D4986) |
| Burner Angle Adjustment | 0°, 20°, 45° |
| Gas Flow Control | Precision Rotameter + High-Accuracy Pressure Regulator |
| Exhaust System | Top-Mounted Forced Ventilation |
| Optional Accessory | ASTM D5207 Compliant Burner Calibration Kit |
| Regulatory Alignment | IEC 60695-11-10/-20, ISO 1210, ISO 9770, ISO 9772, ISO 9773, GB/T 2408, GB/T 5169.17, GB/T 8332 |
| Brand | MOTIS |
|---|---|
| Origin | Shanghai, China |
| Model | UL94-X |
| Compliance | UL 94 (HB, V-0/V-1/V-2, 5VA/5VB, VTM-0/1/2, HF-1/HF-2/HBF) |
| Standards | UL 94, IEC 60695-11-10/-20, ISO 1210, ISO 9770, ISO 9772, ISO 9773, GB/T 2408, GB/T 5169.17, GB/T 8332, ASTM D5025, ASTM D4986, ASTM D5207 |
| Chamber Volume | ≥0.75 m³ |
| Interior Finish | Matte black non-reflective surface |
| Viewing Window | Large transparent borosilicate glass viewport |
| Burner Adjustment | 0°, 20°, 45° tilt positions |
| Gas Control | Precision pressure regulator + rotameter for propane/butane flow |
| Exhaust System | Top-mounted forced-air exhaust duct with fume hood interface |
| Optional Accessory | ASTM D5207-compliant burner calibration kit |
| Brand | MOTIS |
|---|---|
| Origin | Shanghai, China |
| Model | UL94-X |
| Compliance | UL 94 (HB, V-0/V-1/V-2, 5VA/5VB, VTM-0/1/2, HF-1/HF-2/HBF) |
| Chamber Volume | ≥0.75 m³ |
| Interior Finish | Matte Black |
| Viewing Window | Extra-Large Tempered Glass |
| Burner Adjustment | 0°, 20°, 45° |
| Gas Supply | Precision Regulated Propane or Methane |
| Flow Control | Rotameter with ±1% Full-Scale Accuracy |
| Pressure Regulation | High-Accuracy Dual-Stage Pressure Reducer |
| Burner Types | Bunsen (ASTM D5025), Ribbon (ASTM D4986) |
| Exhaust System | Top-Mounted Forced Ventilation |
| Optional | ASTM D5207 Burner Calibration Kit |
| Standards Supported | UL 94, IEC 60695-11-10/-20, ISO 1210/9770/9772/9773, GB/T 2408/5169.17/8332 |
| Brand | MOTIS |
|---|---|
| Origin | Shanghai, China |
| Model | VF-1 |
| Compliance Standards | ASTM D6413, ISO 6941, GB/T 5455, CFR 1615/1616, CA TB117 |
| Chamber Material | Stainless Steel (304) |
| Viewing Window | Tempered Borosilicate Glass |
| Burner Adjustment | Linear Sliding Rail with Precision Needle Valve |
| Sample Holder Options | Multiple Interchangeable Fixtures for Woven, Knitted, and Nonwoven Textiles |
| Flame Height Range | 10–50 mm (adjustable via calibrated needle valve) |
| Ignition Source | Laboratory-grade Bunsen-type Gas Burner (Propane or Butane) |
| Brand | MOTIS |
|---|---|
| Origin | Shanghai, China |
| Model | VF-2 |
| Compliance | CA TB 117 (Sec. A & B), CPAI 84 (Wall & Top), FAA FAR 25 App. F Part I, Boeing BSS 7230, Airbus AITM 2.0002, ASTM D6413 |
| Ignition Source | ASTM D5025-compliant Bunsen burner |
| Flame Application | Motorized lateral burner movement |
| Timing Resolution | 0.1 s |
| Chamber Construction | Stainless steel with transparent quartz side viewport |
| Sample Holders | Interchangeable stainless steel fixtures for multi-standard adaptability |
| Control Mode | Fully automated flame positioning and timing sequence |
| Brand | MOTIS |
|---|---|
| Model | VFT |
| Standard Compliance | ISO 15025, AQ 6103–2007 |
| Ignition Source | Propane burner |
| Ignition Duration | Adjustable (default 10 s) |
| Sample Orientation | Vertical |
| Measured Parameters | Afterflame time, afterglow time, char length |
| Burner Control | Stepper motor–actuated angular positioning for bottom-edge and edge ignition |
| Display | Integrated LCD interface |
| Power Supply | 220 V, 50 Hz |
| Ambient Conditions | 20 ± 2 °C, 65 ± 5 % RH |
| Dimensions (W × H × D) | 410 × 900 × 380 mm |
| Gas Supply | Propane |
| Brand | MOTIS |
|---|---|
| Model | VFT |
| Application | Automotive Interior Trim (M-Class Vehicles ≥22 Passengers) |
| Compliance | GB 32086–2015 |
| Construction | Stainless Steel Sample Holder Frame (560 mm H × 170 mm W) |
| Burner | Brass, Adjustable ±30° Tilt & Vertical Positioning |
| Ignition | High-Voltage Pulse Auto-Ignition |
| Control System | PLC + Touchscreen HMI |
| Timing | Fully Automated (Ignition Duration, Afterflame Time, Burn Rate Calculation) |
| Sample Fixation | Dual 2 mm Diameter Pins (27 mm Spacing), 20 mm Height Stop Pins |
| Flame Impingement Distance | 20 mm from Specimen Bottom |
| Marking Line Adjustment | Motorized Positioning |
| Flame Detection | Precision Microswitch-Based Endpoint Sensing |
| Data Handling | Automatic Burn Rate (mm/min) Computation & Timestamped Storage |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Model | NES 713 |
| Compliance Standard | NES 713 (Naval Engineering Standard) |
| Operating Temperature | 800 °C |
| Chamber Volume | V m³ (user-specified per configuration) |
| Sample Mass | 100 g (standard test mass) |
| Toxicity Index Calculation | Σ(C₈ᵢ / Cfᵢ), i = 1 to n |
| Observation Window | Reinforced PTFE-coated polycarbonate viewport |
| Exhaust Control | Timer-actuated automatic purge mode |
| Test Modes | Manual and programmable automatic cycle |
| Chamber Lining | PTFE-bonded stainless steel interior |
| Door Mechanism | Positive-seal dual-latch system |
| Ignition System | Electric spark ignition with auto-shutoff |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | HBK Horizontal Burning Chamber |
| Compliance Standards | ISO 3795, DIN 75200, FMVSS 302, GB 8410, CMVSS 302, FAR 25.853 |
| Sample Dimensions | 356 × 100 × ≤13 mm |
| Fuel | ≥95% purity propane |
| Gas Pressure | 4.0 bar |
| Chamber Dimensions (W×D×H) | 385 × 210 × 365 mm |
| Weight | 26 kg |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | KBK Flammability Test Chamber |
| Compliance | EN ISO 11925-2 |
| Sample Dimensions | 250 × 90 × ≤60 mm |
| Fuel | Propane (≥95% purity) |
| Gas Pressure | 4.0 bar |
| Airflow Velocity Accuracy | ±0.1 m/s |
| Operating Temperature | +23 ± 5 °C |
| Chamber Dimensions (W×D×H) | 700 × 400 × 980 mm |
| Construction Material | Corrosion-Resistant Stainless Steel |
| Viewing Windows | Dual Large-Sized Fire-Rated Glass Doors |
| Adjustable Sample Holder | Horizontal & Vertical Positioning |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | SBK Flammability Test Chamber for Toys |
| Compliance | EN 71-2 |
| Sample Dimensions (H × W) | 610 (310) × 100 mm |
| Sample Holder | Adjustable in Horizontal and Vertical Planes |
| Fuel | Propane (≥95% purity) |
| Gas Pressure | 4.0 bar |
| Operating Temperature | +23 ± 5 °C |
| Chamber Dimensions (W × D × H) | 70 × 70 × 121 cm |
| Construction | Corrosion-Resistant Stainless Steel |
| Viewing | Dual Large Fire-Rated Glass Doors |
| Gas Control | Front-Mounted Main Shut-Off Valve and Fine-Tuning Burner Control Valve |
| Pressure Monitoring | Integrated Pressure Gauge Regulator |
| Burner Positioning | Contaminant-Shielded Burner Displacement Mechanism |
| Application Scope | Textiles, Furnishings, Toy Accessories (e.g., Wigs, Facial Hair Simulants, Plush Trim) |
| Brand | MOTIS |
|---|---|
| Origin | Shanghai, China |
| Model | NFP-1 |
| Compliance | NFPA 701 (2004 & 2009 Ed.), Test Method 1 |
| Burner Type | Meker Burner |
| Heat Output | 10,500 BTU/hr |
| Ignition | Automatic spark ignition |
| Burn Duration | Fixed 20 s ± 0.1 s |
| Timer Resolution | 0.1 s |
| Sample Holder | Standard ASTM/NFPA-compliant specimen clamp |
| Max Fabric Areal Density | 700 g/m² (21 oz/yd²) |
| Chamber Construction | Calcium silicate board lined with stainless steel exterior |
| Configuration | Open-top vertical combustion chamber |
| Brand | MOTIS |
|---|---|
| Origin | Shanghai, China |
| Model | NFP-2 |
| Construction | Full stainless steel chamber |
| Burner | Standard NFPA 701-compliant burner with precision mass flow control and real-time gas flow monitoring |
| Ignition Angle | 25° fixed-angle burner head |
| Timing System | Programmable pre-set ignition duration + automatic test time logging |
| Compliance | NFPA 701–2004 (Method 1 & Method 2) |
| Brand | Phinix |
|---|---|
| Model | PX03002 |
| Standards Compliance | UL 94 HB/V0/V1/V2/5VA/5VB, IEC 60695-11-10/-11-20, ISO 1210/9770/9773, GB/T 2408/5169.17 |
| Chamber Volume | >0.75 m³ |
| Viewing Window | Large tempered glass, interior illumination ≤20 lux |
| Flame Source | HUMBOLDT Trillium burner (ID 9.5±0.3 mm, ASTM D5025 compliant) |
| Flame Orientation | Motorized 0°/20°/45° adjustment |
| Ignition | High-voltage pulse auto-ignition |
| Gas Control | Imported rotameter + differential pressure sensor + precision pressure regulator + solenoid valve |
| Sample Positioning | Motorized linear stage (horizontal/vertical), software-controlled |
| Control System | PLC + industrial touchscreen HMI |
| Safety Features | Auto gas cutoff after 10 min idle, flame duration alert, real-time V (mm/min) calculation and display |
| Optional | 50W/500W flame calibration kit with ±0.1°C certified thermocouples |
| Power | AC 220 V, 50 Hz, 2 A |
| Dimensions (Upper Cabinet) | 1350×700×1000 mm (W×D×H) |
| (Lower Cabinet) | 1350×700×650 mm |
| Weight | ~70 kg |
| Brand | MOTIS |
|---|---|
| Origin | Shanghai, China |
| Model | Polynorme 503 |
| Applicable Standard | NFP 92-503 |
| Test Principle | Radiant Heat + Pilot Flame Ignition |
| Application Scope | Building Materials & Railway Components Combustibility Assessment |
| Compliance | French National Fire Safety Regulations for Construction and High-Speed Rail Infrastructure |
| Brand | PW |
|---|---|
| Model | PW-UL94 |
| Compliance | UL 94 (1997), ASTM D4804-03, ISO 9773:1998 |
| Sample Dimensions | (200 ± 5) mm × (50 ± 1) mm × thickness (min/max required) |
| Flame Application | Two 3-second applications of 20 mm Bunsen burner flame (vertical mode) |
| Specimen Orientation | Vertical (VTM-0/VTM-1/VTM-2) and Horizontal (HB) |
| Ignition Source | Precision-calibrated methane or propane burner with adjustable flow control |
| Chamber Volume | ≥ 0.5 m³ |
| Viewing Window | Heat-resistant borosilicate glass with integrated LED lighting and real-time observation port |
| Safety Features | Automatic gas shutoff, flame failure detection, exhaust interlock, dual-layer door seal, internal temperature monitoring |
| Brand | Qinji |
|---|---|
| Origin | Shanghai, China |
| Model | RSC-157 |
| Compliance Standards | GB/T 2408, ISO 1210, GB 4609, IEC 60950, UL 94, IEC 707, IEC 695-2-2 |
| Burner Positioning | Motorized vertical adjustment with programmable timing and positional repeatability |
| Gas Leak Detection | Integrated high-sensitivity combustible gas alarm system |
| Flame Application | Manual jog control for burner elevation/depression to precisely set flame-to-specimen distance |
| Exhaust System | Dedicated forced-air exhaust ducting with external venting capability |
| Sample Holders | Dual independent fixtures—horizontal (H) and vertical (V) configurations |
| Test Mode Switching | Toggle switch for rapid, tool-free transition between horizontal and vertical flame exposure protocols |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | Relia-Burn |
| Pricing | Available Upon Request |
| Brand | SDL Atlas |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | M233G |
| Price Range | USD 14,000 – 28,000 |
| Application Field | Textiles & Home Furnishings |
| Test Angle | 45° |
| Flame Exposure Duration Options | 1 s, 5 s, 20 s |
| Timing Resolution | 0.1 s |
| Construction | Stainless Steel Chamber with Tempered Glass Viewing Window |
| Optional Accessory | Nylon Brush Kit |
| Brand | SDL Atlas |
|---|---|
| Model | M233M |
| Test Orientation | Vertical |
| Construction | Stainless Steel Combustion Chamber with Tempered Glass Viewing Window |
| Burner Type | Standard ASTM/ISO-Compliant Bunsen Burner |
| Gas Control | Manual or Optional Electromagnetic Solenoid Valve with Auto-Ignition and Timer Control |
| Sample Holder | Interchangeable Fixtures per Standard (e.g., ASTM D6413, ISO 6941, GB/T 5455, NFPA 701) |
| Compliance | Designed for Textile and Home Furnishing Flammability Testing |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Setchkin |
| Pricing | Available Upon Request |
| Brand | MOTIS |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | SPI |
| Pricing | Upon Request |
| Brand | MOTIS |
|---|---|
| Model | STF |
| Standard Compliance | UL 910 / NFPA 262 |
| Chamber Construction | Stainless Steel (304) with Refractory Brick Lining |
| Observation Window | Dual-Layer Quartz Glass |
| Flame Propagation Monitoring | LED Indicator Strip System |
| Smoke Seal | 2 mm 304 Stainless Steel Water-Tight Trough |
| Exhaust Fan | 3 kW, 380 V / 50 Hz, Variable-Frequency Drive, ≥8000 m³/h Capacity |
| Burner | Dual-Orifice Copper Burner, Heat Output Adjustable from 5.3 MJ/min (UL 910 baseline) up to 100 MJ/min via Mass Flow Control |
| Ignition System | High-Voltage Spark Igniter (44 kV / 50 mA, Minimum Electrode Voltage 1.8 kVp) |
| Pressure Monitoring | Differential Pressure Sensor, Range 0–250 Pa, Accuracy ±0.5 Pa (System Accuracy ±2 Pa) |
| Temperature & Smoke Signal Acquisition | 1 Hz Sampling Rate, Linearized Photometric Smoke Density Detection |
| Gas Control | 316 Stainless Steel Mass Flow Controller, Propane Range 0–2.3 g/s, Accuracy ±1% FS (0.6–2.3 g/s), Repeatability ±0.5% FS, NIST-Traceable Calibration |
| Software | Integrated Test Management Platform with Real-Time Logging of Airflow Velocity, Chamber Temperature, Optical Density, and Fuel Consumption |
| Auxiliary Systems | Municipal Water Supply Interface, Methane Gas Delivery Subsystem, Overhead Hoist for Sample Handling |
| Sample Mounting | Stepped Access Platform with Integrated Support for Calcium Silicate Cover Boards |
| Thermal Insulation | High-Temperature Ceramic Fiber Blanket within 304 Stainless Enclosure |
| Application Domain | Horizontal Cable Tray Fire Propagation Testing per UL 910/NFPA 262 for Plenum-Rated Communications Cables |
| Brand | TESTech |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TTech-GBT9775 |
| Price | Upon Request |
| Power Supply | AC 220 V ±10 V, 50 Hz |
| Fuel Source | Liquefied Petroleum Gas (LPG) or Town Gas |
| Flame Length Range | 10–100 mm |
| Flame Application Time | 0–999.9 s |
| Timing Accuracy | ±0.1 s |
| Temperature Range | Ambient to 1000 °C (Class 0.5 accuracy) |
| Temperature Stabilization | >3 min at 800 ±30 °C |
| Burner Inner Diameter | Φ9.5 ±0.5 mm, Length ≈100 mm |
| Chamber Dimensions (L×W×H) | 0.7 × 0.4 × 0.72 m |
| Weight | 25 kg |