| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | MODEL3100 |
| Pipette Type | Manual Multi-Channel Pipette |
| Volume Range Options | 0.2–1.0 mL, 0.4–2.0 mL, 1.0–5.0 mL, 2.0–10.0 mL |
| Minimum Increment | 0.1 mL (for 0.2–1.0 & 0.4–2.0 mL ranges), 0.5 mL (for 1.0–5.0 & 2.0–10.0 mL ranges) |
| Accuracy | ±1.0% |
| Coefficient of Variation (CV) | ≤1.0% |
| Tip Compatibility | Nichiryo Standard Clear Tips (00-MPT-1, 00-MPT-2, 00-BMT2-X, 00-BMT2-Z) |
| Piston Material | PTFE-Coated Stainless Steel |
| Tip Packaging | 1000 or 2000 per pack |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | MODEL5100 |
| Pipette Type | Single-Channel Manual Pipette |
| Adjustable Volume Range | 15–25 mL and 30–50 mL (via interchangeable volume adjustment tubes) |
| Accuracy | ±1.0% |
| Coefficient of Variation (CV) | ≤1.0% |
| Compatible Tip Type | Nichiryo TL50 Series (e.g., 00-51TL50) |
| Tip Packaging | 50 pcs per pack |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | MODEL8100 |
| Type | Motorized Multi-Step Electronic Dispenser |
| Sample Volume Range | 1 µL – 5 mL (configurable via 7 interchangeable syringe barrels) |
| Accuracy | ±0.8% to ±2.5% (volume-dependent) |
| Precision (CV) | ≤0.3% to ≤4.0% (volume-dependent) |
| Max. Dispensing Cycles per Fill | 10–58 (barrel-dependent) |
| Sterilization | Autoclavable at 121 °C for 20 min (all barrels except 3.0 mL and 60 mL) |
| Syringe Tip Length | 50 mm |
| Materials | PP (standard), PE (N3 and Z barrels) |
| Drive Mechanism | Pulse-driven positive displacement |
| Compliance | Designed for GLP-compliant liquid handling workflows |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | MODEL8800 |
| Instrument Type | Multi-Channel Manual Continuous Dispenser |
| Number of Channels | 8 |
| Operating Range | 10–100 µL (6 preset volumes: 10, 20, 25, 40, 50, 100 µL) |
| Accuracy | ±2.0% (at specified volumes) |
| Coefficient of Variation (CV) | ≤1.2% |
| Syringe Options | A (520 µL), B (1300 µL) |
| Max. Sequential Dispensing Cycles | 50 (at 10 µL), 25 (at 20/25 µL), 12 (at 40/50/100 µL) |
| Dimensions (with syringes installed) | 285 × 82 × 23 mm |
| Sterilization Compatibility | Autoclavable at 121°C for 20 min |
| Actuation | Manual lever-driven continuous dispensing |
| Brand | AS ONE (Nichiryo) |
|---|---|
| Origin | Japan |
| Manufacturer | Nichiryo Co., Ltd. |
| Model | 00-NSTP (equivalent to AS ONE catalog no. 2-5001-01) |
| Dispensing Range | 1–5000 µL |
| Dispense Increment | 1 µL |
| Drive Type | Motorized (Electric) |
| Channel Configuration | Single-Channel |
| Compliance | CE-marked, ISO 8655-compliant design principles |
| Calibration | Factory-calibrated per ISO 8655-6 |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | NPLO2 |
| Pipette Type | Manual Single-Channel |
| Volume Range | 0.5 µL – 50 mL (via interchangeable syringe barrels) |
| Accuracy | ±0.3% to ±5% (volume-dependent) |
| Precision (CV) | <0.2% to <8.0% (volume-dependent) |
| Sterilizable Options | Yes (selected syringe barrels) |
| Compatible Tips | BMT-UT tips (NS-V), NS-ASP adapters (NS-Y/Z), Eppendorf 4780-compatible syringes |
| Syringe Material | Polypropylene (barrel), Polyethylene (plunger) |
| Max Sequential Dispensing Cycles | 48 |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | Nichipet ECO |
| Pipette Type | Single-channel Manual Pipette |
| Volume Range | 20 µL – 10 mL |
| Maximum Capacity | 10 mL |
| Accuracy | ±3.0% to ±6.0% |
| Precision (CV) | ≤3.0% to ≤6.0% |
| Tip Compatibility | Nichiryo Glass Tips (S, L, X, Z series) |
| Operating Principle | Air-displacement with ceramic piston and PTFE-coated tip cone |
| Sealing | Dual O-ring tip ejection mechanism |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | EX II MULTI |
| Pipette Type | Manual Multi-Channel Pipette |
| Channels | 8 or 12 |
| Volume Range Options | 0.5–10 µL (V), 5–100 µL (S), 20–200 µL (L), 30–300 µL (K) |
| Minimum Increment | 0.01 µL (V), 0.1 µL (S), 0.2 µL (L), 1 µL (K) |
| Sterilization | Full-unit autoclavable at 121°C for 20 min |
| Tip Compatibility | BMT2-UT/UTWR/UTWRB, FUT/FUTRB, BMT2-SG/SGR/SGRB, FSE/FSERB, FAG/FAGRB, BMT2-K/KR/KRB |
| Material | UV-resistant polymer housing |
| Weight Reduction | ~30% vs. previous generation |
| Ergonomic Design | Rotatable 360° plunger knob, reduced plunger force, serviceable modular construction |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | Nichipet EX II |
| Type | Manual Single-Channel Pipette |
| Volume Range | 0.1–10,000 µL |
| Maximum Capacity | 10 mL |
| Accuracy | ±2.0% |
| Sterilization | Autoclavable at 121°C for 20 min |
| Tip Ejection | Non-contact, plastic ejector mechanism |
| Sealing Material | PTFE in air-tight components |
| Piston Material | Ceramic (for ≥200 µL models) |
| Filter Tip Compatibility | Integrated filter sleeve (≥1000 µL models) |
| Volume Adjustment | Digital dial with lockable knob |
| Minimum Increment | 0.002–10 µL (model-dependent) |
| Tip Compatibility | BMT2-series tips (UT, SS, SG, LE, X, Z) |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | Nichipet EX Plus II |
| Pipette Type | Manual Single-Channel |
| Volume Range | 0.1–10,000 µL |
| Maximum Capacity | 10 mL |
| Accuracy | ±2.0% |
| Tip Compatibility | BMT2-series (UT, SS, SE, L, X, Z) |
| Sterilization | Autoclavable (121°C, 20 min) & UV-Capable |
| Calibration | In-lab adjustable via integrated locking dial |
| Piston Material | Ceramic (≥100 µL), Fluoropolymer-coated stainless steel (≤10 µL) |
| O-rings | FKM (fluoroelastomer) |
| Spring | Corrosion-resistant alloy |
| Chemical Resistance | Verified against strong acids, bases, ketones, esters, aldehydes, and inorganic/organic solvents |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | NSS-1000II Basic |
| Type | Benchtop Robotic Liquid Handler |
| Configuration | Standalone or Integrated Platform |
| Programming Interface | C-language or Visual Basic SDK |
| Compliance | Designed for GLP/GMP-aligned lab environments |
| Application Scope | Life Sciences, Pharmaceutical R&D, Clinical Diagnostics, Chemical Laboratories |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | Pipette Mate NEO |
| Power Source | Rechargeable Lithium-Ion Battery (Charging Time: 4 h |
| Input Voltage | 100–240 V, 50/60 Hz, 0.2 A |
| Filter | Hydrophobic PTFE, 20 mm × 0.2 µm |
| Compatible Pipettes | 1–100 mL glass or plastic serological pipettes |
| Sterilization | Autoclavable at 121 °C for 20 min (liquid-contact components only) |
| Weight | 167 g |
| Certifications | CE, RoHS |
| Operating Environment | Compatible with laminar flow hoods and UV sterilization workflows |
| Ergonomics | Integrated speed control dial, vertical stand-alone design (no support rack required) |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | Pipette Mate NEO |
| Instrument Type | Single-Channel Electric Pipette Controller |
| Power Source | Rechargeable Lithium-Ion Battery (3.6 V, 600 mAh) |
| Operating Time | ~1700 dispenses per full charge (4-hour charging time) |
| Pipette Compatibility | 1–100 mL plastic or glass serological pipettes |
| Filter | Hydrophobic 0.2 µm (20 mm diameter) |
| Compliance | CE, RoHS |
| Autoclavable Components | Nosecone, Silicone Holder, Filter |
| Weight | 167 g |
| Ergonomic Design | Self-standing, UV-resistant housing |
| Speed Control | Dial-type adjustable suction/dispense speed |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Type | Sterilizable Disposable Pipette Tips |
| Packaging Options | Bulk (1000 pcs) and Rack (96-well or 50-well formats, sterilized or non-sterilized) |
| Volume Range | 0.1–10 µL, 0.5–10 µL, 2–200 µL, 50–300 µL, 100–1000 µL, 1000–5000 µL, 1000–10000 µL |
| Material | High-purity polypropylene (PP) |
| Sterilization | Autoclavable at 121 °C for 20 minutes |
| DNase/RNase-Free | Yes (except X and Z series) |
| UV-Compatible | Yes |
| Brand | KJ GROUP |
|---|---|
| Purity | >99.9% |
| Thickness | 0.025 mm |
| Width | 150 mm |
| Length | 5000 mm |
| Resistivity | 6.97 μΩ·cm (at 20 °C) |
| Density | 8.9 g/cm³ (at 25 °C) |
| Melting Point | 1453 °C |
| Boiling Point | 2732 °C |
| Net Weight | 200 g |
| Brand | NIL |
|---|---|
| Origin | Denmark |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NIL-4i |
| Pricing | Contact for Quotation |
| Wafer Size | 4 in |
| Imprintable Area | 2 in diameter |
| Imprint Pressure Range | 0–25 PSI (upgradable to 100 PSI) |
| Mold Substrate Dimensions | 5 × 0.090 in |
| Typical Throughput | < 5 min/wafer |
| Controller Platform Dimensions | 5.8 × 16.5 × 12 in |
| Main Platform Dimensions | 17 × 16 × 15 in |
| Weight (Controller) | 18.5 lb |
| Weight (Main Unit) | 45 lb |
| Operating Temperature | 10–35 °C |
| Relative Humidity | ≤65% RH |
| Compressed Air Supply | Filtered, 70–100 PSI |
| Vacuum Source | ≤−14 PSI |
| Power Input | 110–220 VAC, 2 A, 50/60 Hz |
| Cleanroom Class | ISO Class 6 (Class 1000) or better |
| Brand | NIL |
|---|---|
| Origin | Denmark |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NIL |
| Pricing | Upon Request |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Circulating Constant-Temperature Bath |
| Circulation Mode | Internal & External |
| Temperature Control | Refrigeration & Heating |
| Bath Volume | 10 L |
| Temperature Range | −40 °C to +200 °C |
| Temperature Stability | ±0.1 °C |
| Programming Capacity | 32 Segments |
| Compressor | Hermetically Sealed Imported (Tecumseh/Taikang) |
| Refrigerant | Environmentally Friendly (R-404A or R-507 compliant) |
| Safety Features | Overheat & Overload Protection, Auto-Restart on Power Recovery, User-Configurable Power-On Mode |
| Timing Function | Adjustable Operation Duration with Auto-Shutdown |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Refrigerated/Heating Circulating Bath |
| Bath Volume | 10 L |
| Temperature Range | −40 °C to +200 °C |
| Temperature Stability | ±0.1 °C |
| Control Mode | PID with Microprocessor |
| Circulation | Internal & External |
| Refrigerant | Environmentally Compliant (R-404A or R-507 Equivalent) |
| Programming Capacity | 32 Segments |
| Safety Features | Compressor Overheat & Overload Protection, Auto-Restart on Power Recovery |
| Compliance | Designed for GLP-compliant labs |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | DC-0510 |
| Instrument Type | Constant-Temperature Bath |
| Circulation Mode | Internal & External Circulation |
| Temperature Control | Dual-mode (Heating & Refrigeration) |
| Bath Chamber Dimensions | 260 × 200 × 200 mm (L × W × H) |
| Temperature Range | −40 °C to +100 °C |
| Temperature Stability | ±0.1 °C |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | DC-0515 |
| Instrument Type | Constant-Temperature Bath |
| Circulation Mode | Internal & External Circulation |
| Temperature Control | Dual-mode (Heating & Refrigeration) |
| Bath Chamber Dimensions (L×W×H) | 300 × 250 × 200 mm |
| Temperature Range | –5 °C to +100 °C |
| Temperature Stability | ±0.05 °C |
| Display | 7-inch Tilted Touchscreen |
| Compressor | Secop (Germany) Hermetic Scroll Compressor |
| Refrigerant | R134a (ODP = 0, GWP = 1430) |
| Pump Flow Rate | Adjustable up to 18 L/min |
| Max. External Load Pressure | 0.2 MPa |
| Safety Protections | Compressor Overheat & Overload Protection, Dry-run Prevention, Overtemperature Alarm |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | DC-0530 |
| Instrument Type | Water/Oil Bath Thermostatic Circulator |
| Circulation Mode | Internal & External Dual Circulation |
| Temperature Control | Dual-mode (Heating & Refrigeration) |
| Bath Dimensions (L×W×H) | 440 × 325 × 200 mm |
| Temperature Range | −5 °C to +100 °C |
| Temperature Stability | ±0.05 °C |
| Display | 7-inch Tilted Touchscreen |
| Compressor | Secop (Germany) Hermetic Scroll Compressor |
| Refrigerant | R-134a (ODP = 0, GWP = 1430) |
| Pump Flow Rate | Adjustable up to 20 L/min (external loop), max pressure 0.4 bar |
| Safety Features | Compressor overheat & overload protection, dry-run prevention, over-temperature alarm, auto-restart with memory retention |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | DC-1006 |
| Instrument Type | Circulating Constant-Temperature Bath |
| Circulation Mode | Internal & External |
| Temperature Control | Refrigeration & Heating Combined |
| Bath Dimensions (L×W×H) | 260 × 200 × 140 mm |
| Temperature Range | −10 °C to +100 °C |
| Temperature Stability | ±0.05 °C |
| Display | 7-inch TFT Touchscreen |
| Pump Flow Rate | 0–20 L/min (DC Speed-Controlled), Max Head: 5 m |
| Refrigeration System | Eco-friendly Non-CFC Compressor-Based |
| Safety Features | Overtemperature Alarm (adjustable upper/lower limits), Auto-Delay Restart (3 min after power interruption), Overheat & Overload Protection, Self-Tuning PID Control, Fuzzy Logic Ambient Compensation |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | DC-1010 |
| Instrument Type | Constant-Temperature Bath |
| Circulation Mode | Internal & External Circulation |
| Temperature Control | Dual-mode (Heating & Refrigeration) |
| Bath Chamber Dimensions | 260 × 200 × 200 mm (L×W×H) |
| Temperature Range | −10 °C to +100 °C |
| Temperature Stability | ±0.05 °C |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | DC-1030 |
| Instrument Type | Constant-Temperature Circulating Bath |
| Circulation Mode | Internal & External Dual Circulation |
| Temperature Control | Heating & Refrigeration |
| Tank Dimensions (L×W×H) | 440 × 325 × 200 mm |
| Temperature Range | −10 °C to +100 °C |
| Temperature Stability | ±0.05 °C |
| Display | 7-inch Tilted Touchscreen Interface |
| Compressor | Secop (Danfoss Group) Hermetic Scroll Compressor |
| Refrigerant | R-134a (ODP = 0, GWP = 1430) |
| Pump Flow Rate | Adjustable up to 20 L/min (external loop), max. pressure 0.4 bar |
| Safety Features | Compressor overheat & overload protection, dry-run prevention, over-temperature alarm, auto-shutdown on timer completion |
| Power Supply | AC 220 V ± 10%, 50/60 Hz, 2.8 kW |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | DC-3030 |
| Instrument Type | Constant-Temperature Bath |
| Circulation Mode | Internal & External Circulation |
| Temperature Control | Dual-mode (Heating & Refrigeration) |
| Bath Chamber Dimensions | 440 × 325 × 200 mm (L×W×H) |
| Temperature Range | −30 °C to +100 °C |
| Temperature Stability | ±0.1 °C |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | DC-4010 |
| Instrument Type | Circulating Temperature Bath |
| Circulation Mode | Internal & External Loop |
| Temperature Control | Dual-mode (Heating & Refrigeration) |
| Bath Chamber Dimensions | 260 × 200 × 200 mm (L × W × H) |
| Temperature Range | −40 °C to +100 °C |
| Temperature Stability | ±0.1 °C |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | DC-4015 |
| Instrument Type | Circulating Temperature Bath |
| Circulation Mode | Internal & External Loop |
| Temperature Control | Dual-mode (Heating & Refrigeration) |
| Bath Chamber Dimensions (L×W×H) | 300 × 250 × 200 mm |
| Temperature Range | −40 °C to +100 °C |
| Temperature Stability | ±0.1 °C |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | DCW-0506 |
| Instrument Type | Water/Oil Bath Circulator |
| Circulation Mode | Internal & External |
| Temperature Control | Dual-mode (Heating & Refrigeration) |
| Bath Chamber Dimensions (L×W×H) | 260 × 200 × 140 mm |
| Temperature Range | −6 °C to +100 °C |
| Temperature Stability | ±0.05 °C |
| Display | 7-inch Tilted Touchscreen |
| Compressor | Secop (formerly Danfoss) Hermetic Scroll Compressor |
| Refrigerant | R134a (ODP = 0, GWP = 1430) |
| Pump Flow Rate | Adjustable up to 15 L/min (external loop) |
| Safety Protections | Compressor overheat & overload cutoff, dry-run protection, overtemperature alarm |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | DCW-1015 |
| Instrument Type | Refrigerated & Heated Circulating Bath |
| Circulation Mode | Internal & External Dual-Mode Circulation |
| Temperature Control | Dual-mode (Heating & Refrigeration) |
| Bath Chamber Dimensions (L×W×H) | 280 × 250 × 220 mm |
| Temperature Range | −10 °C to +100 °C |
| Temperature Stability | ±0.05 °C |
| Display | 7-inch Tilted Touchscreen Interface |
| Compressor | Secop (Danfoss Group) Hermetic Scroll Compressor |
| Refrigerant | R-134a (ODP = 0, GWP = 1430) |
| Safety Protections | Compressor Overheat & Overload Protection, Dry-run Prevention, Auto-Shutdown on Timer Completion |
| Power Supply | 220 V AC, 50 Hz |
| Pump Flow Rate | Adjustable up to 15 L/min (external loop), max head pressure 0.2 MPa |