Common Laboratory Equipment
Filter
Showing 10891–10920 of 17931 results
| Brand | NAYO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | A96 |
| Pricing | Available Upon Request |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | HP-1000 |
| Unit Price | USD 28,500 (approx.) |
| Hydrogen Peroxide Capacity | 5 L |
| Airflow | Adjustable |
| Sterilization Volume | 1,000 m³ |
| Vaporization Temperature | Ambient (no heating) |
| Pre-sterilization Relative Humidity Control | ≤40% RH |
| HEPA Filtration Efficiency | ≥99.99% at 0.3 µm |
| Sterilant | Aqueous Hydrogen Peroxide (H₂O₂) |
| Log Reduction | ≥6-log for Geobacillus stearothermophilus spores |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | NEH-10 |
| Price | USD 495 (FOB Beijing) |
| Brand | New Biolink |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Membrane Pilot Testing System |
| Pricing | Upon Request |
| Sample Processing | Wastewater Treatment |
| Membrane Types Supported | Ceramic & Organic (Polymeric) Membranes |
| Configurable MWCO Range | 1 kDa – 500 kDa |
| Operating Pressure Range | Up to 10 bar |
| Feed Capacity | 5–100 L per batch |
| System Architecture | Skid-mounted, Modular, Benchtop-to-Pilot Scale |
| Brand | New Biolink |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | NF-Series |
| Pricing | Available Upon Request |
| Sample Processing | Industrial Wastewater & Process Streams |
| Molecular Weight Cut-Off (MWCO) | 100–1000 Da |
| Membrane Charge | Surface-Charged (Donnan Exclusion Dominant) |
| Divalent Ion Rejection | >90% (e.g., SO₄²⁻, Ca²⁺, Mg²⁺) |
| Monovalent Ion Rejection | 10–40% (e.g., Na⁺, Cl⁻) |
| Operating Temperature Range | 5–45 °C |
| Max Inlet Pressure | 25 bar |
| Feed pH Range | 3–11 |
| Membrane Material | Polyamide Thin-Film Composite (TFC) |
| System Configuration | Benchtop Skid-Mounted with Recirculation Loop, Pressure Control, and Permeate Monitoring |
| Brand | New Biolink |
|---|---|
| Model | UHP-RO Series |
| Max Operating Pressure | 20 MPa |
| Membrane Type | High-Pressure Tolerant RO Element with Open-Channel Feed Spacer |
| Feed Compatibility | High-Salinity Wastewater (TDS up to 120,000 mg/L) |
| Recovery Rate | ≥75% (system-dependent) |
| Origin | Beijing, China |
| Application | Laboratory-Scale Wastewater Concentration and Brine Minimization |
| Brand | New Chi / SCIENTZ |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | SCIENTZ-Bead 15 |
| Pricing | Upon Request |
| Brand | ADVANTEC (Yan Hua Dong Yang) |
|---|---|
| Origin | Japan |
| Model | 10-905 |
| Type | Manual Date/Number Embossing Punch |
| Max. Sheet Capacity | 10 sheets (64 g/m² paper, 8-digit imprint) |
| Cycle Time | 1.5 s/cycle (50 Hz) / 1.2 s/cycle (60 Hz) |
| Dimensions | 214 × 295 × 485 mm |
| Weight | 12.7 kg |
| Die Block Compatibility | MOLE 905-208 |
| Power Supply | None (Manual Operation) |
| Brand | Newport |
|---|---|
| Origin | USA |
| Body Material | 316 Stainless Steel |
| Optical Path Length | 1 cm |
| Clear Aperture | 11/16 in (≈17.5 mm) |
| Pressure Rating | 100,000 psi (689 MPa) |
| Port Configuration | Two 1/4-in SUPERPRESSURE fittings, orthogonal (90° apart) |
| Application | In-situ UV-Vis-NIR spectroscopy under extreme pressure conditions |
| Compliance | Designed for integration with ASTM E275, ISO 1042, and USP <857> spectrophotometric validation protocols |
| Brand | Newport |
|---|---|
| Origin | USA |
| Type | Imported Laboratory Diaphragm Compressor |
| Model Series | 46-14021-2, 46-14025-2, 46-14035-2, 46-14060-2, 46-14067, 46-14068 |
| Compression Principle | Pneumatically Actuated Metal Diaphragm |
| Flow Rate | 0–0.5 Nm³/h |
| Maximum Output Pressure | 0–200 MPa (0–30,000 psi) |
| Dew Point | +3 °C at Atmospheric Pressure |
| Particulate Filtration | <0.01 µm |
| Air Drive Inlet/Outlet Port | 0.053 cm / 1.27 cm |
| Fluid Side Port | 0.635 cm OD Tubing |
| Power Requirement | 50 Hz AC Supply |
| Compliance | Designed for ISO 8573-1 Class 2 compressed gas purity and GLP-compliant lab environments |
| Brand | Newport |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NP Series |
| Price | USD $150,000 |
| Max Temperature | 200 °C |
| Number of Channels | 3 |
| Extraction Vessel Volume | 20 L |
| Max Operating Pressure | 68.9 MPa |
| CO₂ Mass Flow Rate | 1 kg/min |
| Extraction Range | Configurable |
| Brand | Newport Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SuperPresure |
| Pricing | Available Upon Request |
| Brand | Newport Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Lab-Scale High-Pressure Reactor Series |
| Price | USD $50,000 |
| Usable Volume Range | 23–4520 mL |
| Construction Material | Modular Corrosion-Resistant Alloy with Interchangeable Liners |
| Operating Pressure | Up to 139 MPa (20,000 psi) |
| Vacuum Capability | 46–139 MPa (absolute, gauge-referenced) |
| Oscillation Angle | 30° |
| Oscillation Frequency | 36 cycles/min |
| External Drive Motor | Integrated AC Servo |
| Pressure Gauge | Dual-scale Analog + Digital Output |
| Heating Jacket | Segmented Resistive Heating with Independent Thermal Zones |
| Liner Options | Removable Pyrex® Glass, Electroless Nickel-Coated Stainless Steel, or Custom Alloy Liners |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 3-550 |
| Instrument Type | Box-Type Muffle Furnace |
| Max Temperature | 1050 °C |
| Temperature Control Accuracy | ±1 °C (at setpoint stability) |
| Max Power | 5600 W |
| Ramp-to-Max-Temp Time | 25 min |
| Heating Method | Embedded Resistance Heaters |
| Internal Chamber Dimensions | 15.2 × 15.2 × 22.9 cm (L×W×H) |
| Chamber Volume | 5.3 L |
| Voltage/Frequency | 200–250 V, 50/60 Hz |
| Temperature Range | 50–1100 °C |
| Temp Uniformity | ±8 °C (at 1000 °C, steady-state) |
| Ramp Rate | 0.1–40 °C/min |
| Cooling Profile | Natural convection-based |
| Safety | Interlocked vertical-lift door with automatic power cutoff |
| Brand | Neytech |
|---|---|
| Origin | USA |
| Model | VULCAN 3-550 |
| Type | Box-type Muffle Furnace |
| Max Temperature | 1100 °C |
| Temperature Control Accuracy | ±5 °C |
| Max Power | 1800 W |
| Heating Rate | 0.1–40 °C/min |
| Internal Chamber Dimensions | 4 × 13 × 12 cm (W×D×H) |
| Chamber Volume Options | 2 L, 9 L, 28 L |
| Temperature Uniformity | ±8 °C |
| Temp Range | 50–1100 °C |
| Programmable Profile | 9-segment, 3-step ramp/soak |
| Delayed Start | Up to 7 days |
| Heating Element | Resistance Wire |
| Chamber Material | Composite Refractory Liner |
| Nitrogen Purity | <3 ppm O₂, Dew Point −56 °C |
|---|---|
| Nitrogen Flow | 0–500 mL/min |
| Nitrogen Pressure | 0.4 MPa |
| Hydrogen Purity | 99.999% |
| Hydrogen Flow | 0–500 mL/min |
| Hydrogen Pressure | 0.4 MPa |
| Air Flow | 0–2000 mL/min |
| Air Pressure | 0.4 MPa |
| Power Consumption | 330 W |
| Dimensions (W×D×H) | 350 × 350 × 500 mm |
| Net Weight | ~33 kg |
| Brand | Nichipet (Nichiryo) |
|---|---|
| Origin | Japan |
| Type | Manual Multi-Channel Pipette |
| Channels | 8 or 12 |
| Volume Range | 0.5–10 µL, 10–100 µL, 20–200 µL, 30–300 µL |
| Maximum Capacity | 300 µL |
| Accuracy | ±0.01 µL (at lowest range) |
| Compliance | ISO 8655-2:2022, GLP-ready design |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Product Line | Nichipet Air |
| Pipette Type | Air-displacement Manual Pipette |
| Channel Configurations | Single-channel, 8-channel, 12-channel |
| Volume Range | 0.1–2 µL (ultra-low volume models) |
| Accuracy | ±3% |
| Weight Optimization | Reduced plunger force, minimized body mass, and low tip ejection force |
| Color Coding | 8 distinct pastel (macaron-style) color variants for single-channel models |
| Compliance | Designed in accordance with ISO 8655-2:2022 (Piston-operated volumetric apparatus — Part 2: Piston pipettes) and compatible with GLP/GMP workflows requiring traceable liquid handling |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | Nichipet Air |
| Volume Range Options | 0.1–2 µL (Gray), 0.5–10 µL (Pink), 2–20 µL (Beige), 10–100 µL (Orange), 20–200 µL (Yellow), 100–1000 µL (Blue), 500–5000 µL (Green), 1000–10000 µL (White) |
| Increment Resolution | 0.002–10 µL (model-dependent) |
| Operating Principle | Air-displacement positive displacement hybrid mechanism with low-force plunger actuation |
| Brand | Nichipet (Nichiryo) |
|---|---|
| Origin | Japan |
| Type | Air-displacement single-channel manual pipette |
| Channels | 1 |
| Volume Range | 0.1–2 µL, 0.5–10 µL, 2–20 µL, 10–100 µL, 20–200 µL, 100–1000 µL, 500–5000 µL, 1000–10000 µL |
| Maximum Capacity | 10 mL |
| Accuracy (at lowest range) | ±0.002 µL (for 0.1–2 µL setting) |
| Weight | 70 g |
| Actuation Force Reduction | Up to 70% vs. conventional models |
| Calibration | Tool-free adjustment via volume dial and locking fixture |
| Color-Coded Volume Ranges | Yes |
| Compliance | Designed for ISO 8655-compliant operation and GLP/GMP laboratory workflows |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | Nichipet FII & VII |
| Type | Manual Single-Channel Adjustable-Volume Pipette |
| Volume Range | 10–1000 µL |
| Accuracy | ±0.5% to ±1.2% (varies by volume) |
| Coefficient of Variation (CV) | ≤0.2% to ≤0.6% (volume-dependent) |
| Tip Compatibility | BMT2-series and F-series sterile filtered tips (e.g., BMT2-SG, FSGRB, BMT2-LE, FLERB) |
| Operating Principle | Air-displacement positive displacement (FII: fixed-volume |
| VII | triple presettable volumes) |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | ACCUPENSER JR |
| Instrument Type | Manual Adjustable Bottle-top Dispenser |
| Automation Level | Manual |
| Volume Range Options | 0.2–10 mL (AJ-1), 0.4–20 mL (AJ-2), 1–50 mL (AJ-5), 2–100 mL (AJ-10) |
| Minimum Increment | 0.05 mL (AJ-1), 0.1 mL (AJ-2 & AJ-5), 0.25 mL (AJ-10) |
| Coefficient of Variation (CV) | ≤0.1% |
| Bottle Compatibility | Standard 500 mL and 1 L reagent bottles (neck dimensions identical) |
| Bottle Dimensions (W × H, mm) | 75 × 210 (165), 100 × 210 (165), 146 × 210 (165) — values in parentheses indicate collapsed height when vernier head is folded |
| Materials in Contact with Liquids | Chemically resistant polymers |
| Sterilization | Autoclavable at 121°C for 20 minutes |
| Compliance | Designed to support GLP-compliant workflows |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | Custom-Made Pipettes |
| Instrument Type | Single-Channel Manual Pipette |
| Automation Level | Manual |
| Channel Count | Single |
| Volume Range | Custom-Defined (Typically 0.1–10,000 µL) |
| Accuracy & Precision | Compliant with ISO 8655 (per customer-specified calibration range) |
| Regulatory Compliance | Designed to support GLP/GMP workflows and FDA 21 CFR Part 11–aligned documentation protocols |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | Dispet Ex |
| Dispensing Range | 0.2–10 mL (DP-10), 0.4–20 mL (DP-20), 1–5 mL (DP-5), 2–10 mL (DP-10) |
| Minimum Increment | 0.05–0.25 mL |
| Accuracy | ±1.0% |
| Coefficient of Variation (CV) | ≤0.2% |
| Bottle Compatibility | Ø22 mm (for DP-5/DP-10), up to Ø45 mm (with optional adapters) |
| Adapter Options | DP-1118 (18 mm), DP-1119 (19 mm), DP-1122 (22 mm), DP-1124 (24 mm), DP-1125 (25 mm), DP-1128 (28 mm), DP-1133 (33 mm), DP-1138 (38 mm), DP-1145 (45 mm) |
| Included Accessories | One 220 mm flexible PTFE-lined tubing (user-cuttable) |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | DISPET EX II |
| Dispensing Volumes | 100–250 mL (±2.0%), 500–1000 mL (±1.0%), 1000–2000 mL (±1.0%) |
| Coefficient of Variation (CV) | ≤0.4% (100–250 mL), ≤0.2% (500–2000 mL) |
| Bottle Neck Compatibility | GL-28, GL-32, GL-45 (bottles sold separately) |
| Liquid Contact Materials | Chemically resistant PTFE, FEP, and ETFE components |
| Design | Handheld, portable, ergonomic manual dispenser |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | DISPET EX II |
| Type | Manual Bottle Top Dispenser |
| Volume Range | 0.2–10 mL |
| Minimum Graduation | 0.05 mL |
| Accuracy | ±0.1% of full scale |
| Maximum Permissible Error | ±0.5% of set volume |
| Pressure Resistance | Up to 6 bar |
| Temperature Resistance | Up to 120 °C |
| Material Compatibility | Chemically resistant PTFE, FFKM, and glass-reinforced PPS components |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | DISPET Mini |
| Dispensing Volumes | 100–250 mL (±2.0%), 500–1000 mL (±1.0%), 1000–2000 mL (±1.0%) |
| Coefficient of Variation (CV) | ≤0.4% (100–250 mL), ≤0.2% (500–2000 mL) |
| Bottle Neck Compatibility | GL-28 standard thread |
| Liquid Contact Materials | Chemically resistant PTFE, ETFE, and FEP components |
| Regulatory Compliance | Designed for ISO 8655-compliant volumetric dispensing procedures |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | DISPET Mini |
| Type | Manual Bottle Top Dispenser |
| Volume Range | 100–2000 µL (selectable in 5 fixed increments: 100, 250, 500, 1000, 2000 µL) |
| Accuracy | ±0.4% |
| Precision (CV) | ≤2% |
| Construction | Chemically resistant PTFE, ETFE, and PP components |
| Compatibility | Fits GL45 standard bottle threads |
| Certifications | ISO 8655-3 compliant for piston-type dispensers |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | MODEL2100DG |
| Type | Manual Multi-Channel Continuous Dispenser |
| Dispensing Range Options | 0.2–1.0 mL (00-21DG-1), 0.4–2.0 mL (00-21DG-2), 1.0–5.0 mL (00-21DG-5), 2.0–10.0 mL (00-21DG-10) |
| Minimum Increment | 0.01–0.10 mL depending on model |
| Display Resolution | 0.01 mL (DG-1/DG-2), 0.02 mL (DG-5), 0.10 mL (DG-10) |
| Fluid Contact Materials | PTFE, Tygon® tubing, polypropylene, Pyrex® glass, ceramic, platinum-iridium alloy |
| Housing | Impact-resistant polymer shell protecting internal glass and piston components |
| Ergonomics | Single-hand operation, lightweight design (<300 g) |