| Brand | Ortoalresa |
|---|---|
| Origin | Spain |
| Model | Biocen 22 R |
| Type | Benchtop Refrigerated Centrifuge |
| Speed Range | 100–18,100 rpm |
| Max RCF | 31,865 × g |
| Max Capacity | 8 × 15 mL |
| Temperature Range | –20 °C to +40 °C (1 °C increments) |
| Cooling Medium | R-449A/HFO (CFC-free) |
| Dimensions (W×D×H) | 276 × 640 × 272 mm |
| Noise Level | <60 dB(A) |
| Compliance | EN 61010-1, EN 61010-2-020, EN 61326-1, EN 61326-2-6, EU Directives 2011/65/EU, 2012/19/EU, 2014/30/EU, 2014/35/EU, 98/79/EC |
| Safety Features | Automatic dual-lock lid, emergency lid release, imbalance detection, rotor auto-recognition, over-speed protection, stainless steel chamber, sterilizable rotors & adapters |
| Brand | Ortoalresa |
|---|---|
| Origin | Spain |
| Centrifuge Type | Benchtop |
| Maximum Capacity | 4 × 400 mL |
| Maximum Speed | 14,300 rpm |
| Maximum RCF | 21,948 × g |
| Dimensions (W × D × H) | 490 × 620 × 390 mm |
| Display | TFT Color Touchscreen |
| Acceleration/Deceleration Control | Progressive (PCBS), up to 175 selectable ramps |
| Unbalance Detection System (ULS) | Real-time bucket position identification |
| Programmable Protocols | 40 user-defined methods with password protection |
| Noise Level | <60 dB(A) |
| Motor | Brushless induction motor |
| Safety Compliance | EN 61010-1, EN 61010-2-020, EN 61326-1, EN 61326-2-6 |
| Regulatory Conformance | 2011/65/EU (RoHS), 2012/19/EU (WEEE), 2014/30/EU (EMC), 2014/35/EU (LVD), 98/79/EC (IVDR) |
| Brand | Ortoalresa |
|---|---|
| Origin | Spain |
| Instrument Type | Benchtop Centrifuge |
| Cooling Function | Refrigerated (−20 °C to 40 °C) |
| Maximum Capacity | 4 × 400 mL |
| Maximum Speed | 14,300 rpm |
| Maximum RCF | 21,948 × g |
| Dimensions (W × D × H) | 670 × 770 × 390 mm |
| Noise Level | <60 dB(A) |
| Rotor Type | Swinging-bucket (standard), with optional angle and microplate rotors |
| Safety Compliance | EN 61010-1, EN 61010-2-020, EN 61326-1, EN 61326-2-6 |
| Refrigerant | R-449A (HFO-based, zero ODP, low GWP) |
| Programmable Protocols | 40 user-defined methods with password protection |
| Control Interface | TFT color touchscreen (visible from ≥3 m) |
| Brand | Ortoalresa |
|---|---|
| Origin | Spain |
| Instrument Type | Benchtop Centrifuge |
| Maximum Speed | 2500 rpm |
| Maximum RCF | 866 × g |
| Maximum Capacity | 12 × 6 mL |
| Rotor Configuration | Horizontal Swing-Out Rotor |
| Separation Target | Large Organelles / Viruses |
| Dimensions (W × D × H) | 410 mm × 530 mm × 320 mm |
| Noise Level | < 60 dB(A) |
| Compliance | EN 61010-1, EN 61010-2-101, EN 61010-2-020, EN 61326-1, EN 61326-2-6, Directive 2011/65/EU, 2012/19/EU, 2014/30/EU, 2014/35/EU |
| Brand | Ortoalresa |
|---|---|
| Origin | Spain |
| Type | Benchtop Centrifuge |
| Maximum Speed | 16,500 rpm |
| Maximum RCF | 26,480 × g |
| Maximum Capacity | 4 × 100 mL |
| Dimensions (W×D×H) | 410 × 520 × 320 mm |
| Noise Level | <60 dB(A) |
| Motor | Brushless Induction Motor |
| Safety Compliance | EN 61010-1, EN 61010-2-101, EN 61326-1, EN 61326-2-6 |
| Regulatory Directives | 2011/65/EU (RoHS), 2012/19/EU (WEEE), 2014/30/EU (EMC), 2014/35/EU (LVD), 98/79/EC (IVDD) |
| Brand | Ortoalresa |
|---|---|
| Origin | Spain |
| Instrument Type | Benchtop Centrifuge |
| Cooling Function | Refrigerated (4 °C operation) |
| Rotor Configuration | Fixed-angle and swing-out options |
| Maximum Capacity | 4 × 100 mL |
| Maximum Speed | 16,500 rpm |
| Maximum RCF | 26,480 × g |
| Dimensions (W×D×H) | 590 × 620 × 320 mm |
| Noise Level | <60 dB(A) |
| Power Supply | 220–230 V / 50 Hz (700 W) or 110–120 V / 60 Hz (800 W) |
| Compliance | EN 61010-1, EN 61010-2-101, EN 61010-2-020, EN 61326-1, EN 61326-2-6 |
| Safety Features | Automatic lid locking, imbalance detection, overspeed protection, stainless steel chamber, autoclavable rotors & adapters |
| Brand | Ortoalresa |
|---|---|
| Origin | Spain |
| Model | Digtor 22 C |
| Instrument Type | Benchtop Centrifuge |
| Max Speed | 3000 rpm |
| Max RCF | 2425 × g |
| Max Capacity | 4 × 100 mL |
| Dimensions (W×D×H) | 540 × 650 × 400 mm |
| Noise Level | <60 dB(A) |
| Heating Range | +5°C to 80°C (adjustable in 1°C/1°F steps) |
| Compliance | ASTM D91, D96, D893, D1796, D2273, D2709, D2711, D4007, D5546 |
| Safety Standards | EN 61010-1, EN 61010-2-020, EN 61326-1, EN 61326-2-6, EN 61010-2-010 |
| EU Directives | 2011/65/EU (RoHS), 2012/19/EU (WEEE), 2014/30/EU (EMC), 2014/35/EU (LVD), 98/79/EC (IVDD) |
| Brand | Ortoalresa |
|---|---|
| Origin | Spain |
| Model | Digtor 22 C-8 |
| Instrument Type | Benchtop Centrifuge |
| Max Speed | 3000 rpm |
| Max RCF | 2425 × g |
| Max Capacity | 4 × 100 mL (8" tubes) |
| Dimensions (W×D×H) | 540 × 650 × 400 mm |
| Heating Range | +5°C to 80°C (programmable in 1°C/1°F increments) |
| Compliance | ASTM D91, D96, D893, D1796, D2273, D2709, D2711, D4007, D5546 |
| Safety Standards | EN 61010-1, EN 61010-2-020, EN 61326-1, EN 61326-2-6, EN 61010-2-010 |
| EU Directives | 2011/65/EU (RoHS), 2012/19/EU (WEEE), 2014/30/EU (EMC), 2014/35/EU (LVD), 98/79/EC (IVDD) |
| Brand | Ortoalresa |
|---|---|
| Origin | Spain |
| Model | Digtor 22 Col |
| Type | Benchtop Centrifuge |
| Maximum Speed | 3000 rpm |
| Maximum RCF | 1801 × g |
| Maximum Capacity | 4 × 60 mL |
| Dimensions (W×D×H) | 540 × 650 × 400 mm |
| Noise Level | <60 dB(A) |
| Motor | Brushless Induction Motor |
| Compliance | EN 61010-1, EN 61010-2-020, EN 61326-1, EN 61326-2-6, EN 61010-2-010, EU Directives 2011/65/EU, 2012/19/EU, 2014/30/EU, 2014/35/EU, 98/79/EC |
| Brand | Ortoalresa |
|---|---|
| Origin | Spain |
| Model | Digtor 22 CU |
| Type | Benchtop Centrifuge |
| Max Speed | 3,000 rpm |
| Max RCF | 2,425 × g |
| Max Capacity | 4 × 100 mL |
| Dimensions (W×D×H) | 540 × 650 × 400 mm |
| Noise Level | <60 dB(A) |
| Compliance | EN 61010-1, EN 61010-2-020, EN 61326-1, EN 61326-2-6, Directive 2014/35/EU, 2014/30/EU, 98/79/EC |
| Safety Features | Automatic lid locking, ULS imbalance detection, GRS (Gas Release System) pre-installed, stainless steel chamber, autoclavable rotors & adapters |
| Brand | Ortoalresa |
|---|---|
| Origin | Spain |
| Model | Digtor 22 |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | Up to 14,300 rpm |
| Max RCF | 21,948 × g |
| Max Capacity | 4 × 750 mL |
| Dimensions (W×D×H) | 540 × 650 × 390 mm |
| Noise Level | <60 dB(A) |
| Motor | Brushless Induction Motor |
| Control Interface | Color TFT Touchscreen (visible from ≥3 m) |
| Programmable Memories | 40 (password-protected) |
| Acceleration/Deceleration Ramps | 175 selectable profiles (PCBS) |
| Unbalance Detection System (ULS) | Real-time rotor position identification |
| Safety Compliance | EN 61010-1, EN 61010-2-020, EN 61326-1, EN 61326-2-6 |
| EU Directives | 2011/65/EU (RoHS), 2012/19/EU (WEEE), 2014/30/EU (EMC), 2014/35/EU (LVD), 98/79/EC (IVDD) |
| Brand | Ortoalresa |
|---|---|
| Origin | Spain |
| Model | Dilitcen 22 |
| Type | Benchtop Centrifuge |
| Max Capacity | 4 × 1000 mL |
| Max Speed | 14,300 rpm |
| Max RCF | 21,948 × g |
| Dimensions (W×D×H) | 540 × 650 × 390 mm |
| Noise Level | <60 dB(A) |
| Power Supply | 220–230 V / 50–60 Hz or 110–120 V / 50–60 Hz |
| Power Consumption | 1020 W |
| Compliance | EN 61010-1, EN 61010-2-020, EN 61326-1, EN 61326-2-6, EU Directives 2011/65/EU, 2012/19/EU, 2014/30/EU, 2014/35/EU, 98/79/EC |
| Brand | Ortoalresa |
|---|---|
| Origin | Spain |
| Model | Lacter 21 |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 0–1,200 rpm |
| Relative Centrifugal Force (RCF) | up to 224 × g |
| Maximum Capacity | 12 butyrometers |
| Heating Capability | Up to 80 °C |
| Dimensions (W×D×H) | 365 × 300 × 450 mm |
| Net Weight | 23 kg |
| Power Supply | 220–230 V / 50 Hz or 110–120 V / 50/60 Hz |
| Power Consumption | 500 W (heating mode), 480 W (standard mode) |
| Safety Compliance | EN 61010-1, EN 61010-2-020, EN 61326-1, EN 61326-2-6, EN 61010-2-010 |
| Regulatory Directives | 2011/65/EU (RoHS), 2012/19/EU (WEEE), 2014/30/EU (EMC), 2014/35/EU (LVD), 98/79/EC (IVDD) |
| Brand | Ortoalresa |
|---|---|
| Origin | Spain |
| Instrument Type | Floor-standing centrifuge |
| Cooling Function | Refrigerated (−20 °C to +40 °C) |
| Maximum Speed | 14,300 rpm |
| Maximum RCF | 21,948 ×g |
| Maximum Capacity | 4 × 750 mL |
| Dimensions (W×D×H) | 540 × 650 × 930 mm |
| Noise Level | <60 dB(A) |
| Drive System | Brushless induction motor |
| Control Interface | TFT color touchscreen with real-time RPM/RCF display |
| Programmability | 40 password-protected protocols |
| Safety Compliance | EN 61010-1, EN 61010-2-020, EN 61326-1, EN 61326-2-6 |
| Refrigerant | R-449A (HFO-based, zero ODP, low GWP) |
| Regulatory Conformance | 2011/65/EU (RoHS), 2012/19/EU (WEEE), 2014/30/EU (EMC), 2014/35/EU (LVD), 98/79/EC (IVDR), (EC) No 1005/2009, (EU) No 517/2014 |
| Brand | Ortoalresa |
|---|---|
| Origin | Spain |
| Model | Minicen |
| Instrument Type | Palm-Sized Centrifuge |
| Max Speed | 15,000 rpm |
| Max RCF | 15,596 × g |
| Max Capacity | 12 × 2 mL |
| Rotor Configuration | Fixed-angle rotor (12-position, for 1.5–2.0 mL tubes) |
| Adapters Available | For 0.2–0.4 mL and 0.5–0.6 mL microtubes |
| Dimensions (W×D×H) | 260 × 230 × 130 mm |
| Net Weight | 4 kg |
| Power Supply | 230 V / 110 V, 50–60 Hz |
| Power Consumption | 180 W |
| Noise Level | <60 dB(A) |
| Timer Range | 30 s – 999 min (1 s resolution) |
| Acceleration/Deceleration Control | Programmable stepwise (100 rpm / 100 × g increments) |
| Safety Compliance | EN 61010-1, EN 61010-2-020, EN 61326-1, EN 61326-2-6 |
| Regulatory Directives | 2011/65/EU (RoHS), 2012/19/EU (WEEE), 2014/30/EU (EMC), 2014/35/EU (LVD), 98/79/EC (IVDD) |
| Brand | Ortoalresa |
|---|---|
| Origin | Spain |
| Model | Plasma 22 |
| Type | Benchtop Centrifuge |
| Max Speed | 3000 rpm |
| Max RCF | 1288 × g |
| Capacity | 8 × 9/15 mL |
| Dimensions (W×D×H) | 270 × 400 × 270 mm |
| Net Weight | 19 kg |
| Power Supply | 220–230 V / 50–60 Hz (CE156) or 110–120 V / 50–60 Hz (CE165) |
| Power Consumption | 120 W |
| Noise Level | <60 dB(A) |
| Acceleration/Deceleration Ramps | 175 programmable profiles |
| Timer Range | 1–99 min ±5 s |
| Display | LCD showing rpm, rcf, time, acceleration/deceleration status |
| Safety Compliance | EN 61010-1, EN 61010-2-020, EN 61326-1, EN 61326-2-6 |
| Regulatory Directives | 2011/65/EU (RoHS), 2012/19/EU (WEEE), 2014/30/EU (EMC), 2014/35/EU (LVD), 98/79/EC (IVDR) |
| Brand | Ortoalresa |
|---|---|
| Origin | Spain |
| Model | Unicen 21 |
| Type | Benchtop Centrifuge |
| Max. Speed | 4200 rpm |
| Max. RCF | 2938 × g |
| Max. Capacity | 4 × 100 mL |
| Dimensions (W×D×H) | 410 × 520 × 320 mm |
| Noise Level | <60 dB(A) |
| Power Supply | 220–230 V / 50–60 Hz (CE 126), 110–120 V / 50–60 Hz (CE 127) |
| Power Consumption | 280 W |
| Safety Compliance | EN 61010-1, EN 61010-2-101, EN 61010-2-020, EN 61326-1, EN 61326-2-6 |
| Regulatory Directives | 2011/65/EU (RoHS), 2012/19/EU (WEEE), 2014/30/EU (EMC), 2014/35/EU (LVD), 98/79/EC (IVDR) |
| Brand | Ortoalresa |
|---|---|
| Origin | Spain |
| Model | Vetcen |
| Type | Benchtop Centrifuge |
| Max Speed | 11,500 rpm |
| Max RCF | 12,716 × g |
| Max Capacity | 6 × 1.5 mL + 6 × capillary tubes (1.5 × 75 mm) |
| Dimensions (W×D×H) | 270 × 400 × 270 mm |
| Noise Level | <60 dB(A) |
| Acceleration/Deceleration | 3-step programmable (Fast, Soft, Free) |
| Timer Range | 1–99 min (1 min resolution) |
| Control | Microprocessor-based with LED display (RPM/RCF/time) |
| Safety | Automatic lid lock, imbalance detection, over-speed protection, stainless steel chamber, autoclavable rotors & adapters |
| Compliance | EN 61010-1, EN 61010-2-101, EN 61010-2-020, EN 61326-1, EN 61326-2-6 |
| Brand | Orton |
|---|---|
| Origin | USA |
| Equipment Type | Horizontal Tube Furnace |
| Model | GTF-MD Series |
| Maximum Temperature | 1600 °C |
| Gradient Zone Length | 12 in (300 mm) or 16 in (405 mm) |
| Gradient Options | 10 °C/in or 20 °C/in |
| Corresponding ΔT Across Gradient Zone | 120 °C, 160 °C, 240 °C, or 320 °C |
| Compliance | ASTM C829A & C829B |
| Brand | Hefei Kejing |
|---|---|
| Origin | Anhui, China |
| Model | OTF-1200X-4-R-II |
| Type | Horizontal Dual-Zone Tube Furnace |
| Max Temperature | 1200°C |
| Temp Control Accuracy | ±1°C |
| Max Power | 4 kW |
| Heating Rate (to max temp) | 10°C/min |
| Internal Dimensions | 100 mm O.D. × 1200 mm L |
| Rotation Speed | 0–10 RPM (adjustable) |
| Tilt Angle | Left 0–30°, Right 0–15° |
| Vacuum Level | 1×10⁻² torr |
| Continuous Operating Temp | 1100°C |
| Heating Zone Length | 400 mm (2×200 mm zones) |
| Uniform Temp Zone | 150 mm (±1°C) |
| Voltage | 208–240 V AC, Single Phase |
| Circuit Breaker Requirement | 30 A |
| Net Weight | 100 kg |
| Overall Dimensions | 1300 × 600 × 1200 mm |
| Compliance | CE certified |
| Key | Max Temp: 1200°C (<1 hr) |
|---|---|
| Temp Control Accuracy | ±1°C |
| Heating Rate | ≤20°C/min (recommended ≤10°C/min) |
| Heating Zone Length | 40 mm |
| Uniform Temp Zone | 150 mm (±1°C) |
| Tube Dimensions | OD 100 mm × ID 94 mm × L 1450 mm |
| Power | 3 kW |
| Voltage | AC 208–240 V, 1-phase, 50/60 Hz |
| Vacuum Level | ≤0.05 Torr (pump-dependent) |
| Net Weight | ~85 kg |
| External Dimensions | 660 L × 400 W × 1450 H mm |
| Heating Element | Mo-doped Fe-Cr-Al alloy with ZrO₂ coating |
| Cooling Medium Compatibility | Liquid nitrogen, ice water, or quenching oil |
| Compliance | CE, UL/MET/CSA (for components >24 V), optional TÜV or CSA single-unit certification |
| Brand | Hefei Kejing |
|---|---|
| Origin | Anhui, China |
| Model | OTF-1200X-60HG |
| Max Operating Temperature | 1100°C |
| Continuous Working Temperature | 1000°C |
| Heating Zone Length | 440 mm |
| Uniform Zone Length | 150 mm (±1°C) |
| Tube Dimensions | OD 60 mm × ID 52 mm × L 1000 mm |
| Tube Material | Seamless Nickel-Based Alloy |
| Max Pressure Rating | 30 PSI (inert/O₂) / 5 PSI (H₂) |
| Vacuum Capability | ≤1×10⁻⁵ Torr |
| Power Rating | 3.0 kW |
| Voltage | Single-phase AC 208–240 V, 50/60 Hz |
| Max Ramp Rate | ≤20°C/min |
| Temperature Control | 30-Stage Programmable PID with Over-Temp & H₂-Leak Safety Interlock |
| H₂ Detection Threshold | <10% LEL (3M sensor) |
| Gas Flow Control | Stainless Steel Needle Valve + 1000 mL/min Rotameter |
| Exhaust Handling | Catalytic Combustion via 1/4" SS Exhaust Line |
| Cooling | Dual-Wall Air-Cooled Housing (Surface Temp <60°C) |
| Insulation | High-Purity Al₂O₃ Microfiber Vacuum-Formed Liner |
| Internal Coating | 1750°C Imported Al₂O₃ Reflective Layer |
| Heating Element | Mo-Doped Fe-Cr-Al Alloy with ZrO₂ Protective Coating |
| Required Ancillary Equipment | QL-500 High-Purity H₂ Generator (500 mL/min, ≥99.999% purity, CE-certified) |
| Max Temp | 1100°C |
|---|---|
| Max Pressure | 20 MPa |
| Heating Zone | 250 mm |
| Tube Dimensions | 55 mm O.D. × 20 mm I.D. × 550 mm L |
| Power | 2.5 kW |
| Voltage | AC 208–240 V, 50/60 Hz |
| Temp Uniformity | ±1°C (50 mm), ±2°C (70 mm) |
| Control | 30-Stage PID with Thermocouple Break Protection |
| Pressure Monitoring | Integrated Front-Panel Digital Gauge with Adjustable High/Low Alarm |
| Cooling | Dual-layer Air-Cooled Shell + Aluminum Heat Sink |
| Insulation | High-Purity Al₂O₃ Fiber + Imported High-Temp Al₂O₃ Coating |
| Seal | OFHC Copper O-Ring (CF-Style Flange) |
| Certification | CE, ZL-2011-2-0077158.0 |
| Brand | Hefei Kejing |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | OTF-1200X-III-80SL |
| Instrument Type | Horizontal Tube Furnace |
| Max Temperature | 1200 °C (<1 hr) |
| Continuous Operating Temp | 1100 °C |
| Temperature Uniformity | ±1 °C over 600 mm (400–1200 °C) |
| Control Accuracy | ±1 °C |
| Heating Rate (max) | 100 °C/min |
| Cooling Rate (max, under inert/vacuum) | 10 °C/s |
| Total Power | 7 kW |
| Voltage | AC 208–240 V, 50/60 Hz, Single Phase |
| Heating Element | Mo-doped Fe-Cr-Al Alloy |
| Tube Dimensions | Quartz, OD 80 mm × ID 75 mm × L 2400 mm |
| Heating Zone Length | 3 × 300 mm (900 mm total) |
| Effective Sliding Travel | 600 mm on 1200 mm Cr-plated Steel Dual Rails |
| External Dimensions | 2500 × 510 × 750 mm (L×W×H) |
| Net Weight | 150 kg |
| Vacuum Compatibility | Up to 10⁻⁵ Torr (with turbomolecular pump) |
| Safety Certifications | CE |
| Warranty | 12 months (excludes consumables: quartz tube, O-rings, heating elements) |
| Brand | MTI Corporation |
|---|---|
| Origin | Hefei, Anhui, China |
| Model | OTF-1200X-III-VT |
| Max Temperature | 1200 °C |
| Continuous Operating Temperature | 1100 °C |
| Temperature Uniformity | ±1 °C over 400 mm (isothermal zone) |
| Heating Rate | ≤20 °C/min (to max temp) |
| Temperature Control | Triple independent PID controllers, 30-segment programmable ramp/soak profiles per zone |
| Furnace Tube | High-purity quartz, OD 50 mm × ID 44 mm × L 1200 mm (also available in OD 60 mm and OD 80 mm variants) |
| Heating Zones | Top (135 mm), Center (260 mm), Bottom (135 mm) |
| Power Supply | AC 208–240 V, 1Φ, 50/60 Hz |
| Max Power Consumption | 4.8 kW (requires 30 A circuit breaker) |
| Cooling | Dual-layer air-cooled steel shell |
| Insulation | High-purity alumina fiber core with high-temperature alumina coating |
| Heating Elements | Mo-doped Fe–Cr–Al alloy wire with zirconia protective coating |
| Vacuum Compatibility | 10⁻² Torr (mechanical pump), 10⁻⁵ Torr (turbo-molecular pump) |
| Sealing System | Stainless steel flanges with integrated mechanical pressure gauge and stainless steel shut-off valve |
| Safety Features | Over-temperature cutoff, K-type Omega armored thermocouples, fail-safe thermal interlock |
| Certifications | CE-marked |
| Weight | ~115 kg |
| Dimensions (L×W×H) | 700 mm × 700 mm × 1680 mm |
| Warranty | 12 months parts and labor (excludes consumables: furnace tube, O-rings, heating elements) |
| Brand | Hefei Kejing |
|---|---|
| Origin | Anhui, China |
| Model | OTF-1200X-M12 |
| Max. Temperature | 1000 °C |
| Temp. Control Accuracy | ±1 °C |
| Max. Power | 3 kW |
| Max. Ramp Rate | ≤20 °C/min |
| Heating Element | Molybdenum-doped Fe-Cr-Al Alloy |
| Tube Dimensions | 100 mm O.D. × 94 mm I.D. × 650 mm L |
| Furnace Chamber Material | High-purity Al₂O₃ Fiber with High-temp Al₂O₃ Coating |
| Control System | 30-Stage PID Programmable Controller |
| Safety Features | Over-temperature & Thermocouple Break Protection |
| Certified | CE, UL (for components >24 V), TUV/UL/CSA optional |
| Weight | 48 kg |
| Dimensions (Closed) | 430 × 480 × 480 mm (L×W×H) |
| Dimensions (Open) | 660 × 480 × 720 mm (L×W×H) |
| Brand | 合肥科晶 |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | OTF-1200X-S2-50SL |
| Price Range | USD 7,000–14,000 |
| Instrument Type | Horizontal Tube Furnace |
| Max Temperature | 1200°C |
| Temperature Control Accuracy | ±1°C |
| Total Power | 2.5 kW |
| Max Ramp Rate (via sliding) | 100°C/min |
| Heating Element | Molybdenum-Doped Fe-Cr-Al Alloy |
| Tube Dimensions | Quartz, OD 50 mm × ID 44 mm × L 1400 mm |
| Chamber Dimensions (per zone) | 200 mm heating length, 60 mm uniformity zone (±1°C @ 400–1200°C) |
| Vacuum Level | 1×10⁻² Torr (mechanical pump) |
| Sliding Rail Length | 1200 mm |
| Net Weight | ~80 kg |
| Certifications | CE, UL/MET/CSA compliant components (>24 V), TÜV/UL61010 or CSA certification available upon request |
| Brand | Hefei Kejing |
|---|---|
| Origin | Anhui, China |
| Model | OTF-1200X-SF |
| Max. Operating Temperature | 1100°C |
| Temperature Control Accuracy | ±1°C |
| Max. Power | 3.6 kW |
| Heating Rate (to Max Temp) | 10°C/min |
| Heating Element Material | Molybdenum-Doped Fe-Cr-Al Alloy |
| Tube Dimensions | 100 mm O.D. × 94 mm I.D. × 750 mm L (Fused Quartz) |
| Heating Zone Length | 440 mm |
| Uniformity Zone | 100 mm |
| Power Supply | Single-phase, 220 V AC, 50/60 Hz |
| Net Weight | 100 kg |
| Closed Footprint | 1220 × 458 × 585 mm |
| Open (Sliding Rail Extended) Length | 1676 mm |
| Vacuum Interface | KF25 |
| Cooling | Water-cooled sliding flange (right) and water-cooled intermediate flange |
| Optional Accessories | PC-based temperature control software, recirculating chiller, vacuum gauge, pressure regulator |
| Brand | 合肥科晶 |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestically Manufactured |
| Model | OTF-1200X-VHP4 |
| Price Range | ¥50,000–¥100,000 |
| Instrument Type | Tubular Furnace |
| Max Operating Temperature | 1100 °C |
| Temperature Control Accuracy | ±1 °C |
| Max Power | 2.2 kW |
| Heating Rate | Not Specified |
| Heating Method | Resistive (Silicon Carbide Heating Elements) |
| Internal Chamber Dimensions | Ø100 mm × 1200 mm (Quartz Tube), Heating Zone Length:300 mm |
| Maximum Applied Pressure | 6 ton-force (10 MPa gauge) |
| Vacuum Level | 1×10⁻⁵ Torr (with turbomolecular pump), 1×10⁻² Torr (with rotary vane pump) |
| Cooling | Water-cooled KF-25 flanges |
| Programmability | 30-segment PID temperature ramping |
| Input Voltage | 208–240 VAC, 50/60 Hz |
| Net Weight | 365 kg |
| Overall Dimensions | 1050 mm (L) × 750 mm (W) × 1750 mm (H) |