| Origin | Tianjin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | QT20500 / QTR20500 / QT20500K / QTSXR20500 |
| Quotation | Available upon Request |
| Capacity | 22.5 L |
| Ultrasonic Frequency | 40 kHz |
| Tank Material | 304 Stainless Steel Deep-Drawn Chamber |
| External Housing | Anodized Aluminum with Anti-Corrosion Coating |
| Internal Dimensions | 500 × 300 × 150 mm (L×W×H) |
| Overall Dimensions | 610 × 350 × 380 mm (L×W×H) |
| Timer Range | 0–30 min (QT20500), 1–20 min (QTR20500), 1–99 min (QT20500K & QTSXR20500) |
| Ultrasonic Power Output | 600 W (fixed) |
| Power Adjustment | None (QT20500), 20–100% (QTR20500 & QTSXR20500), 40–99% (QT20500K) |
| Heating Power | None (QT20500), 800 W (QTR20500 & QTSXR20500) |
| Temperature Control Range | 0–80 °C (heating models only) |
| Display | None (QT20500), LED Digital Display (QTR20500, QT20500K, QTSXR20500) |
| Drain Fitting | Not included |
| Net Weight | 12.0 kg |
| Gross Weight | 14.0 kg |
| Standard Accessories | Stainless Steel Lid and Rack |
| Color | Bright White |
| Critical Components | Fairchild Semiconductor (USA) ICs and Driver Modules |
| Warranty | 3-Year Limited Warranty, Lifetime Technical Support |
| Origin | Tianjin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | QT2060 / QT2060A / QT2060B / QTR2060 |
| Capacity | 2 L |
| Ultrasonic Frequency | 40 kHz |
| Tank Material | 304 Stainless Steel (Deep-Drawn) |
| External Housing | Anodized Aluminum with Corrosion-Resistant Coating |
| Internal Dimensions | 150 × 140 × 100 mm (L × W × H) |
| External Dimensions | 175 × 160 × 200 mm (L × W × H) |
| Timer Range | 0–30 min |
| Ultrasonic Power Output | 60 W (QT2060/QTR2060), 100 W (QT2060A), or Dual-Mode 60/100 W (QT2060B) |
| Heating Function | Optional (QT2060A only |
| Display | LED Timer Only (No Digital Temp/Power Readout) |
| Drain Port | Not Included |
| Weight (Net/Gross) | 2.0 kg / 2.5 kg |
| Standard Accessories | Stainless Steel Lid & Rack |
| Color | Gloss White |
| Key Components | Fairchild Semiconductor (USA) ICs and Drive Electronics |
| Brand | Qtechcorp |
|---|---|
| Origin | Canada |
| Model | QAsh1800 |
| Instrument Type | Box-type Microwave-Assisted Muffle Furnace |
| Max Temperature | 20–1200 °C |
| Temperature Control Accuracy | ±5 °C |
| Max Power Output | 1800 W |
| Heating Rate to Max Temp | ≤60 min |
| Power Supply | 220 V, 50 Hz, 20 A |
| Internal Cavity Dimensions | 36 × 41 × 27 cm (W × D × H) |
| Microwave Frequency | 2450 MHz |
| Exhaust Flow Rate | 150 CFM |
| Operating Ambient | 5–40 °C, 10–80% RH |
| Net Weight | 35 kg |
| Temperature Sensor | R-type Thermocouple |
| Data Acquisition Interval | 5 s |
| Scan Interval | 0.16 s |
| Ceramic Cavity Internal Dimensions | 22 × 14 × 10 cm |
| Brand | QTechCorp |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | QPrep |
| Price Range | USD 13,500 – 40,500 (est.) |
| Deck Capacity | 1 |
| Pipetting Accuracy | ±0.1% (at full scale) |
| Pipetting Volume Range | 1–1000 µL |
| Sample Throughput | 42 samples per run |
| Dimensions | 92 × 48 × 48 cm |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Weight | 35 kg |
| Compatible OS | Windows XP / 7 (USB interface required) |
| Z-Axis Positioning Accuracy | ±0.3 mm |
| Peristaltic Pump Flow Rate | 0.5–2 mL/sec |
| Optional Syringes | 5–25 mL |
| Fluidic Path Materials | PTFE-coated graphite sampling probe |
| Maximum Rack Capacity | 6 standard racks (360 positions) |
| Brand | Qtechcorp |
|---|---|
| Origin | Canada |
| Model | QWave 2000 |
| Sample Capacity | 42 vessels |
| Microwave Source | Dual magnetron |
| Maximum Temperature | 230 °C |
| Power Output | 1200 W |
| Frequency | 2450 MHz |
| Cavity Coating | PTFE-reinforced corrosion-resistant interior |
| Exhaust Flow Rate | 150 CFM |
| Safety Systems | QSens™ real-time pressure/temperature interlock, OPGuard™ active overpressure release, dual IR + fiber-optic temperature monitoring (±0.1 °C), auto-power modulation, rotating turntable + rotating microwave feed |
| Control Interface | 10.9 cm TFT-LCD touchscreen (480 × 272 px, 400 MHz processor) |
| Method Storage | 10 time-temperature, 5 time-power profiles |
| Software | QLAB Analyst™ PC application with audit trail, method synchronization, and GLP-compliant data export |
| Dimensions (W×D×H) | 58 × 61 × 64 cm |
| Weight | 75 kg |
| Electrical Supply | 220 VAC, 50 Hz, 15 A |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Vulcan 42S |
| Instrument Type | Electric Heating Digestion System |
| Automation Level | Fully Automated |
| Digestion Positions | 42 |
| Max Heating Temperature | 230 °C |
| Temperature Control Accuracy | ±1 °C |
| Heating Principle | Resistive Electric Heating |
| Reagent Channels | 12 (expandable) |
| Liquid Delivery Speed | ≥2 mL/s |
| Dispensing Accuracy | ±0.05 mL |
| Volumetric Completion Precision | ±0.5 mm (meniscus height) |
| Graphite Block Capacity | 42 × 50 mL or 30 × 100 mL tubes |
| Dimensions (W×D×H) | 125 × 66 × 75 cm |
| Integrated Fume Hood | Yes |
| Material Construction | All-Plastic (Chemical-Resistant Polymer Enclosure) |
| Reagent Pumps | 6 Syringe Pumps (incl. PTFE-lined HF-compatible pump) + 1 Dilution Pump + 2 Wash Pumps |
| Mixing Mechanism | Programmable Air-Bubble Agitation |
| Final Volume Adjustment | Non-contact Ultrasonic Meniscus Detection |
| Sample Transfer Function | Robotic Arm-Assisted Tube-to-Tube Transfer with On-the-Fly Dilution Capability |
| Brand | Qtechcorp |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | Vulcan42S |
| Instrument Type | Electric Heating Digestion System |
| Automation Level | Fully Automated |
| Digestion Positions | 42 |
| Max Heating Temperature | 230 °C |
| Temperature Control Accuracy | ±1 °C |
| Heating Mechanism | Graphite Block Heater |
| Reagent Channels | 6–12 |
| Brand | Qtechcorp |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Vulcan84 |
| Instrument Type | Electric Heating Digestion System |
| Automation Level | Fully Automated |
| Digestion Positions | 84 |
| Max Heating Temperature | 230 °C |
| Temperature Control Accuracy | ±1 °C |
| Heating Mechanism | Aluminum Block Heater |
| Reagent Channels | 6 |
| Dimensions (W×D×H) | 125 × 66 × 75 cm |
| Reagent Delivery Speed | ≥2 mL/s |
| Liquid Dispensing Accuracy | ±0.05 mL |
| Volume Calibration Precision | ±0.5 mm (meniscus height) |
| Compatible Vessels | 42 × 50 mL or 30 × 100 mL digestion tubes |
| Safety Features | Auto Over-Temperature Protection, Integrated Fume Hood |
| Software | Graphical PC-Based Control with Audit Trail Capability |
| Compliance Standards | EPA Methods 7470, 7471, 200.2, 200.7, 200.8, 3010A, 3020B, 3050B |
| Origin | Tianjin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | QTR-27600 |
| Pricing | Available Upon Request |
| Ultrasonic Frequency | 40 kHz |
| Tank Capacity | 27 L |
| Internal Tank Dimensions | 600 × 300 × 150 mm |
| External Dimensions | 710 × 350 × 380 mm |
| Ultrasonic Power Output | 600 W |
| Heating Power | 800 W |
| Temperature Range | 0–80 °C (adjustable) |
| Timer Range | 1–20 min |
| Display | LED digital interface |
| Tank Material | 304 stainless steel deep-drawn monolithic chamber |
| Housing Material | Imported corrosion-resistant aluminum with anti-rust coating |
| Weight (net/gross) | 15.0 / 20.0 kg |
| Standard Accessories | Stainless steel lid and mesh basket |
| Compliance | CE-marked design principles |
| Key | Origin: Tianjin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | QTR-3120 |
| Capacity | 3 L |
| Ultrasonic Frequency | 40 kHz |
| Tank Material | 304 Stainless Steel (Deep-drawn) |
| External Housing | Anodized Aluminum with Anti-corrosion Coating |
| Internal Dimensions | 240 × 140 × 100 mm (L×W×H) |
| Overall Dimensions | 270 × 160 × 240 mm |
| Ultrasonic Power Output | 120 W (Adjustable: 20–100%) |
| Heating Power | 300 W (Adjustable: 0–80 °C) |
| Timer Range | 1–20 min |
| Display | LED Digital Interface |
| Weight (Net/Gross) | 3.0 / 3.5 kg |
| Standard Accessories | Stainless Steel Lid & Rack |
| Compliance | CE-marked, RoHS-compliant, Designed for ISO/IEC 17025 Laboratory Environment Support |
| Origin | Tianjin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | QT6150 |
| Price | Upon Request |
| Tank Capacity | 6 L |
| Ultrasonic Frequency | 40 kHz |
| Tank Material | 304 Stainless Steel Deep-Drawn Bath |
| External Housing | Imported Anodized Aluminum with Corrosion-Resistant Coating |
| Internal Dimensions | 300 × 150 × 150 mm (L × W × H) |
| Overall Dimensions | 350 × 170 × 280 mm |
| Weight (Net/Gross) | 4.5 / 5.5 kg |
| Timer Range | 1–20 min (Digital LED Display) |
| Ultrasonic Power Output | 180 W (Adjustable: 20–100% in 10% increments) |
| Heating Power | 400 W |
| Temperature Control Range | 0–80 °C (Adjustable in 1 °C steps) |
| Power Supply | AC 220 V, 50 Hz |
| Key Components | Fairchild Semiconductor (USA) ICs and driver modules |
| Standard Accessories | Stainless steel lid, mesh basket, and support rack |
| Compliance | CE-marked |
| Brand | Deepflow |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | CYPAKQUAEX |
| Pricing | Available Upon Request |
| Brand | Lihero |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | LHQCM-2014 |
| Pricing | Available Upon Request |
| Brand | QUANPU |
|---|---|
| Origin | Shanghai, China |
| Model | QP-Plus-3H |
| Hydrogen Generation Principle | Alkaline Electrolysis |
| Output Flow Rate | 300 mL/min |
| Output Pressure | 0.4 MPa |
| Hydrogen Purity | 99.999% |
| Power Consumption | 180 W |
| Dimensions (W×D×H) | 425 × 245 × 390 mm |
| Weight | ~10 kg |
| Operating Temperature | 0–35 °C |
| Relative Humidity | ≤85% |
| Input Power | 220 V ±10%, 50 Hz ±5% |
| Brand | Quanpu |
|---|---|
| Origin | Shanghai, China |
| Model | QP-Plus-A3 |
| Output Flow Rate | 3 L/min |
| Output Pressure | Port A: 0.4 MPa, Port B: 0.5 MPa |
| Air Quality | Oil-free, Dry, Triple-Purified |
| Particle Filtration | ≤0.01 µm |
| Drying Method | Adsorption (Silica Gel) |
| Noise Level | <40 dB(A) |
| Power Supply | 220 V / 50 Hz |
| Max. Power Consumption | 180 W |
| Dimensions (L×W×H) | 550 × 305 × 425 mm |
| Weight | 27 kg |
| Tank Material | Electropolished SS316 |
| Gas Pathway | Electropolished & Ultrasonically Cleaned Stainless Steel Tubing |
| Safety Features | Pressure Relief Valve, High-Sensitivity Pressure Controller, Overcurrent Protection, Manual Vent Valve |
| Certifications | Compliant with ISO 8573-1 Class 1:2:1 (Compressed Air Purity), GLP-Compatible Design |
| Brand | Quanpu |
|---|---|
| Origin | Shanghai, China |
| Model | QPT-300ZD |
| Gas Purity | H₂ ≥ 99.999%, N₂ > 99.999% |
| Output Flow | H₂: 0–300 mL/min, Air: 0–2000 mL/min |
| Output Pressure | N₂: 0–0.5 MPa (factory-set at 0.4 MPa), H₂: 0–0.4 MPa (factory-set at 0.3 MPa), Air: 0–0.45 MPa (factory-set at 0.4 MPa) |
| Design | Integrated monoblock chassis |
| Control Mode | On/Off switch control |
| Power Supply | 220 V ±10%, 50 Hz ±5% |
| Max Power Consumption | 500 W |
| Operating Environment | 0–40 °C, RH ≤85%, non-corrosive, low-dust ambient |
| Dimensions (L×W×H) | 560 × 430 × 360 mm (excl. 30 mm mounting flange) |
| Brand | Quantum Design |
|---|---|
| Origin | USA |
| Manufacturer | Quantum Design, Inc. |
| Type | Imported |
| Model | HelioxVT |
| Pricing | Upon Request |
| Brand | Quantum Design |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Integra |
| Pricing | Upon Request |
| Brand | Quantum Design |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Microstat |
| Price | Upon Request |
| Cooling Method | Vacuum-cryogen-cooled (Liquid Nitrogen or Liquid Helium) |
| Temperature Range | 2.2 K to 500 K |
| Sample Environment | High-vacuum chamber |
| Sample Space (diameter × height) | 20 × 2 mm (N), 20 × 5 mm (He, HiRes) |
| Working Distance | Adjustable from 2.2 mm to 24.5 mm |
| Temperature Stability | ±0.1 K (10 min, Microstat He/HiRes), ±0.5 K (10 min, Microstat N) |
| Cool-down Time | <10 min (N, He), <15 min (HiRes) |
| Cryogen Consumption | <0.5 L/h (He, ~4.2 K), <0.45 L/h (He, HiRes), ~4.2 L/h (LN₂, 77 K) |
| Vibration | <0.1 µm (N, He), <20 nm (HiRes) |
| Lateral Sample Drift | <1 µm/h (N, He), <150 nm/h (HiRes) |
| Electrical Feedthroughs | 4 DC (N), 10 DC (He, HiRes) |
| Controller | Mercury iTC Intelligent Temperature Controller (optional, touch-enabled, 0.1 mK stability, 80 W/channel heating, 24-bit ADC) |
| Brand | Quantum Design |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | Imported |
| Model | OptiCool |
| Instrument Type | Vertical Cryostat |
| Temperature Stability | ±0.2% (T < 20 K) |
| Working Distance | 3 mm |
| Temperature Range | 1.7 K to 350 K |
| Vibration Stability | <10 nm peak-to-peak (horizontal) |
| Cooling Medium | Helium-free, dry-cycle pulse-tube refrigeration system |
| Optical Access | 7 side ports (NA > 0.11), 1 top port (NA > 0.7) |
| Magnetic Field | ±7 T |
| Sample Space | Ø89 mm × 84 mm |
| Electrical Feedthroughs | Standard 16 leads (expandable to 80) |
| Brand | Quantum Design |
|---|---|
| Origin | USA |
| Manufacturer | Quantum Design, Inc. |
| Type | Import |
| Model | Optistat DN, Optistat DN-V, Optistat CF, Optistat CF-V, Optistat Dry TLEX, Optistat Dry BLV |
| Cryogen Options | Liquid nitrogen, liquid helium, or cryogen-free (Cryofree™) |
| Base Temperature | 2.2 K–77.2 K (model-dependent) |
| Minimum Temperature | <3 K (Dry BLV/TLEX), 2.3 K (CF-V), 77.2 K (DN/DN-V) |
| Maximum Temperature | 300 K–600 K (model-dependent) |
| Sample Environment | Exchange gas or high vacuum |
| Sample Space | 20 mm Ø to 40 × 50 mm |
| Temperature Stability | ±0.1 K over 10 min |
| Cooling Time | 10 min (CF-V) to <6 hrs (Dry BLV) |
| Vibration | <0.1 µm RMS (CF-V/CF) to <10 µm RMS (Dry models, with mitigation) |
| Controller Interface | Mercury iTC intelligent temperature controller (optional), touchscreen, 24-bit resolution, 0.1 mK stability, up to 80 W/channel heating |
| Optical Windows | User-replaceable Spectrosil B (UV–mid-IR), CaF₂, ZnSe, TPX, and custom options for UV–THz coverage |
| Brand | Quantum Design |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Quantum Design Oxford Superconducting Magnet and Cryogenic System |
| Instrument Type | Vertical |
| Temperature Range | < 1.5 K to 600 K |
| Magnetic Field Options | 6–14 T (including 6-1-1 T hybrid) |
| Helium-3 Insert Temperature Range | 300 mK – 300 K |
| Sample Space Diameter | up to 50 mm (variable by configuration) |
| Temperature Stability | ±50 mK (standard cryostat), ±3 mK @ 350 mK (HelioxVT), ±0.1 K (optical systems) |
| Cooling Time (RT → base T) | <2 hr (<2 K, dry system), ~90 min (to 5 K, optical magnet), <10 min (Microstat LN₂), <150 min (<3 K, dry refrigeration) |
| Refrigeration Method | Cryogen-free (pulse tube or GM), liquid helium (open-cycle), or liquid nitrogen (open-cycle) |
| Software | oi.DECS (open architecture, Python API, multi-instrument control) |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | CME |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM/ODM Producer |
| Origin Classification | Domestic (China) |
| Model | Quartz Optical Fiber |
| Price | USD 265 (FOB Beijing) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | SYZ-A |
| Instrument Type | Sub-boiling Distiller |
| Heating Power | 1500 W |
| Distillate Output | 1000 mL/h |
| Dimensions (L×W×H) | 530 × 200 × 500 mm |
| Material | High-Purity Fused Quartz (SiO₂) |
| Brand | Zhongke Aobo |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | FGJ |
| Price | USD 2,100 (approx.) |
| Construction Material | Borosilicate Glass & Stainless Steel (KF Vacuum Components) |
| Operating Pressure Range | Low Vacuum to High Vacuum (Mechanical Pump: ≤50 Pa |
| Turbo-Molecular Pump | ≤5×10⁻⁴ Pa) |
| Leak Rate | ≤2×10⁻¹¹ Pa·m³/s |
| Tube Capacity | Up to 1 L |
| Max. Tube OD | 45 mm |
| Min. Tube OD | 8 mm |
| Max. Tube Wall Thickness | 2 mm |
| Max. Tube Length | 500 mm |
| Rotational Speed | 0–20 rpm (adjustable via precision potentiometer, digitally displayed) |
| Vacuum Interface | KF25 |
| Inlet Fitting | 6 mm Swagelok compression |
| Included Accessories | KF25 Gate Valve ×1, KF25 Bellows ×1, KF16 Vent Valve ×1, KF16 Mechanical Vacuum Gauge ×1, Torch Mounting Fixture ×1, Polarizing Viewer ×1, High-Temperature Gloves ×1, Quartz Tubes (with quartz rods) ×2, Quartz Tube Adapter ×1, KF16 Clamp Set ×1, KF25 Clamp Set ×2, 6 mm Inlet Tubing (3 m), Power Adapter ×1 |
| Brand | Abner |
|---|---|
| Origin | Jiangsu, China |
| Model | ABN-PCM-001 |
| Instrument Type | Benchtop Low-Temperature RF Plasma Surface Treater |
| Working Gases | Dual-Channel (Ar, O₂, N₂, H₂, CF₄ compatible) |
| Control Method | Dual-Independent Mass Flow Control |
| Chamber Material | Fused Quartz |
| Vacuum System | Integrated Rotary Vane Pump (Ultimate Pressure ≤ 5 × 10⁻² mbar) |
| RF Power Supply | 13.56 MHz, 0–100 W Adjustable |
| Chamber Volume | 8 L |
| Operating Temperature | Ambient to 60 °C (non-thermal plasma regime) |
| [Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (PRC-Made) |
| Model | 1810-B |
| Instrument Type | Subboiling Distillation Apparatus |
| Output Power | 3.0 kW |
| Voltage/Frequency | 220 V / 50 Hz |
| Dimensions (W×D×H) | 530 × 300 × 440 mm |
| Pure Water Yield | 1800–2500 mL/h |
| Construction Material | High-Purity Fused Quartz (All-Wetted Parts)] |
| Origin | USA |
|---|---|
| Manufacturer | Chandler Engineering (OEM) |
| Distributor Type | Authorized Distributor |
| Product Category | Imported Instrumentation |
| Model | Q6000 Series |
| Pricing | Available Upon Request |
| Brand | Langbo Instruments |
|---|---|
| Model | QW-6 |
| Origin | Jiangsu, China |
| Equipment Type | Laboratory Bottle Washer / Cleaning Validation Tester |
| Temperature Control Range | Ambient to 8°C |
| Rotational Speed Range | 0–200 rpm |
| Timer Range | 0–59 h 59 min |
| Control System | Microprocessor-Based Programmable Logic Controller (PLC) with Digital Interface |
| Brand | The Great Wall |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | R-3001 |
| Capacity | 1 L |
| Rotation Speed | 10–280 rpm |
| Temperature Control Range | 5–35 °C |
| Vacuum Pump Compatibility | SHB-III Circulating Water Vacuum Pump (optional, not integrated) |