| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | Imported |
| Model Numbers | 51029701, 51029702, 51029703, 51029704 |
| Instrument Category | Horizontal Laminar Flow Clean Bench |
| User Configuration | Single-Sided Operation |
| Internal Width Options | 900 mm, 1200 mm, 1500 mm, 1800 mm |
| Standard Work Height | 650 mm |
| Extended Work Height | 950 mm |
| Compliance | GOST, CE (2006/95/EC |
| 2006/121/EC), EN 61010-1 | 2011, EN 61326:2006 |
| Drive System | Brushless DC Motor |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | ECO 0.9 |
| Airflow Type | Vertical Laminar Flow |
| Cleanliness Class | ISO Class 5 (100-level) |
| Noise Level | <55 dB(A) |
| Rated User Capacity | 2 operators |
| Pre-filter | EN779 G3 coarse-to-medium dust filter |
| HEPA Filter | EN1822 H14 (≥99.995% @ 0.3 µm) |
| Work Surface Options | Melamine or 316 stainless steel |
| UV Lamp | Optional |
| Illumination | >1000 lx |
| Power Consumption | 270 W |
| Air Velocity Range | 0.15–0.25 m/s (low mode), 0.36–0.45 m/s (high mode) |
| Compliance | CE marked per 2006/95/EC (LVD), 2004/108/EC (EMC), 2011/65/EC (RoHS), 2006/121/EC (REACH) |
| EN 61010-1 | 2011, EN 61326:2006 |
| Certifications | GOST-R certified for CIS markets |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Invitrogen PowerEase Touch Touchscreen Electrophoresis Power Supply |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Type | Box-Type Muffle Furnace |
| Model | K114 |
| Maximum Temperature | 1100 °C |
| Temperature Uniformity | ±6 °C |
| Control Accuracy | ±2–4 °C |
| Heating Method | Resistance Wire Heating |
| Internal Dimensions | 170 × 130 × 160 mm |
| Chamber Volume | 3.5 L |
| Max Power | 690 W |
| Ramp Rate to Max Temp | 6–12 °C/min |
| External Dimensions | 456 × 646 × 570 mm |
| Net Weight | 36 kg |
| Power Supply | 230 V, 50/60 Hz |
| Insulation | Asbestos-Free Refractory Material |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LabServ™ Automated Sample Processing Workstation |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Ultra-Pure Water System |
| Model | LabTower EDI |
| Pure Water Grade | ASTM Type I |
| Resistivity | 18.2 MΩ·cm |
| TOC | 1–5 ppb |
| Microbial Content | < 1 CFU/mL |
| Endotoxin | < 0.001 EU/mL |
| Particles (>0.1 µm) | < 1 particle/mL |
| Flow Rate Options | 15 L/h or 30 L/h |
| Integrated Storage Tank | 100 L PE tank with recirculation loop and sterile air filter |
| UV Option | Available |
| CO₂ Absorber | Optional |
| Compliance | ASTM D1193, ISO 3696, USP <645>, GLP-ready, FDA 21 CFR Part 11–compatible data logging |
| Brand | Thermo Fisher |
|---|---|
| Origin | Imported |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | LabTower RO |
| Output Flow Rate | 20 L/hr or 40 L/hr |
| Storage Tank Capacity | 100 L (HDPE, light-blocking) |
| Resistivity Monitoring | Yes (electrode constant 0.16 cm⁻¹) |
| Conductivity/Resistivity Display | Backlit LCD with tilt adjustment |
| Operating Modes | Production, Standby, Cleaning |
| Tank Level Indication | % display |
| Data Logging | RS-232 interface with optional printer support |
| GLP Compliance | Yes (audit-trail capable, password-protected parameter settings) |
| Pretreatment | Integrated antiscalant cartridge, 5 µm sediment filter, activated carbon filter |
| RO Membrane Protection | Antiscalant + carbon prefiltration |
| TOC Reduction | ≥99% |
| Particulate Removal (>0.1 µm) | ≥99% |
| Ionic Impurity Removal | ~98% |
| Application Grade | ASTM Type III Reagent Water (per ASTM D1193-20) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Imported |
| Manufacturer | Thermo Fisher Scientific |
| Model | LabTower TII |
| Output Flow Rate | 20 or 40 L/hr |
| Integrated Storage Tank Capacity | 100 L (conical, light-blocking polypropylene) |
| Resistivity | 10–15 MΩ·cm at 25 °C |
| TOC | < 30 ppb |
| Particulates (>0.1 µm) | < 1 particle/mL |
| Compliance | ASTM D1193 Type II, ISO 3696 Grade 2, CLSI-CLRW |
| Temperature Control Accuracy | ±0.1 °C |
| Conductivity Cell Constant | 0.01 cm⁻¹ with automatic temperature compensation |
| Pre-filtration | 5 µm sediment filter + activated carbon cartridge |
| Anti-scaling Cartridge | Integrated scale inhibition for RO membrane protection |
| RO Membrane Rejection | ≥97–99% of inorganic ions, ≥99% of organic compounds, microorganisms, and particulates |
| Final Polishing | Low-TOC, high-capacity mixed-bed ion exchange resin |
| Optional UV Module | 185/254 nm dual-wavelength germicidal lamp (for microbial control) |
| Data Interface | RS-232 with GLP-compliant audit trail and optional thermal printer support |
| User Interface | Backlit 4-line LCD display with password-protected parameter access |
| Operating Modes | Production, Standby (continuous recirculation), Cleaning |
| Tank Drainage | Full emptying via conical bottom geometry |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | Legend X1/X1R & XT/XTR |
| Max Rotor Capacity | 4×1000 mL (XT/XTR) / 4×750 mL (X1/X1R) |
| Max Speed | 15,200 rpm |
| Max RCF | 25,830 ×g |
| Temperature Range | –10 °C to +40 °C (X1R/XTR only) |
| Refrigeration | CFC-free compressor-based cooling |
| Drive System | Brushless DC induction motor |
| Rotor Locking | Auto-Lock® III |
| Biosafety | ClickSeal® sealed bucket system |
| Rotor Material | Fiberlite® carbon-fiber composites |
| Control System | SMARTSpin® microprocessor-based interface |
| Programs | 99 stored methods (5 quick-access) |
| Acceleration/Deceleration Profiles | 9/10 selectable |
| Max Run Time | 9 h 59 min + continuous mode |
| Noise Level | <61 dBA (X1), <55 dBA (X1R), <57 dBA (XT/XTR) |
| Chamber | Stainless steel |
| Compliance | IEC 61010-1, IEC 61010-2-020, ISO 13485 (manufacturing), FDA 21 CFR Part 11-ready software architecture |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Box Furnace |
| Maximum Temperature | 1500°C |
| Temperature Uniformity | ±2–4°C |
| Rated Power | 6400 W |
| Heating Rate (to 1500°C) | 6–12°C/min |
| Heating Element | Silicon Carbide (SiC) Rods |
| Internal Chamber Dimensions | 127 × 304.8 × 152.4 mm (H × D × W) |
| External Dimensions | 660.4 × 736.6 × 635 mm (H × D × W) |
| Voltage/Frequency | 208–240 V, 50/60 Hz |
| Net Weight | 91 kg |
| Controller | Multi-segment Single-Program Digital Controller |
| Thermocouple Type | Type R (Platinum/Rhodium), Rear-Mounted |
| Door Configuration | Vertical Lift |
| Insulation | Moldatherm® High-Density Ceramic Fiber |
| Safety Features | Interlocked Door Switch, Over-Temperature Protection (optional models) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Box Furnace |
| Max Temperature | 1200°C |
| Temperature Uniformity | ±5°C at 1200°C |
| Control Accuracy | ±2–4°C |
| Max Power | 4600 W |
| Ramp Rate to Max Temp | 6–12°C/min |
| Heating Method | Resistance Wire (NiCr or Inconel) |
| Internal Dimensions (H×D×W) | 133.4×355.6×190.5 mm |
| Chamber Volume | 9 L |
| External Dimensions (H×D×W) | 622.3×508×508 mm |
| Net Weight | 66 kg |
| Thermocouple Type | Platinel II (10 ft lead with plug) |
| Insulation | Moldatherm® ceramic fiber |
| Door Design | Bottom-hinged, spring-assisted, floating-pin seal with high-temp insulation and viewing window |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Box Furnace |
| Maximum Temperature | 1700°C |
| Temperature Uniformity | ±2–4°C |
| Rated Power | 5900 W |
| Heating Rate (to 1700°C) | 6–12°C/min |
| Heating Element | Molybdenum Disilicide (MoSi₂) Rods |
| Internal Chamber Dimensions | 228.6 × 266.7 × 279.4 mm (H × D × W) |
| Chamber Volume | 17 L |
| Controller Type | Digital Single-Point |
| Voltage/Frequency | 208–240 V, 50/60 Hz |
| Net Weight | 159 kg |
| Safety Features | Interlocked Door Switch, Rear Gas Inlet (Ø9.5 mm), Moldatherm Insulation, Dual-Wall Construction |
| Cooling | Integrated High-Speed Circulation Fan |
| Thermocouple | Type B (with 3 m cable and standardized connector) |
| Compliance | Designed for GLP-compliant thermal processing environments |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Box Furnace |
| Maximum Temperature | 1200°C |
| Temperature Control Accuracy | ±2–4°C |
| Rated Power | 5800 W |
| Heating Rate (to Max Temp) | 6–12°C/min |
| Heating Method | Resistance Wire |
| Internal Dimensions | 177.8 × 279.4 × 330.2 mm |
| Door Configuration | Vertically Lifting |
| Gas Inlet/Outlet | Rear 0.375″ inlet, Top 1″ exhaust port |
| Thermal Insulation | Moldatherm™ ceramic fiber insulation |
| Heating Element | Patented LGO™ (Low-Glow Oxide) wire |
| Thermocouple Type | Platinel II |
| Safety Features | Automatic power cutoff upon door opening, adjustable overtemperature protection |
| Control System | Integrated digital controller with dual LED display (setpoint & actual temperature), selectable °C/°F units |
| Standard Accessories | One removable combination shelf, Moldatherm™ furnace floor plate |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Type | Tube Furnace |
| Temperature Range | 1100°C to 1700°C |
| Heating Zone Lengths | 304.8 mm, 609.6 mm, or 914.4 mm |
| Configuration | Single-Zone or Triple-Zone |
| Controller | Integrated or External Microprocessor-Based Programmable Controller |
| Orientation | Horizontal or Vertical |
| Compliance | Designed for ASTM E1142, ISO/IEC 17025-compliant laboratory environments |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Split-Tube Furnace |
| Max Temperature | 1200°C |
| Temperature Control Accuracy | ±2–4°C |
| Max Power | 2675 W |
| Ramp Rate (to Max Temp) | 6–12°C/min |
| Heating Method | Resistive Wire Heating |
| Internal Chamber Dimensions | 406.4 × 431.8 × 584.2 mm |
| Voltage/Frequency | 208/240 V, 50/60 Hz |
| Controller Model | CC58114C-1 |
| Tube Diameter Range | 25.4–76.2 mm |
| Heated Zone Length | 304.8 mm |
| External Dimensions (H×D×W) | 406.4 × 431.8 × 584.2 mm |
| Net Weight | 55 kg |
| Compliance | CE, UL Listed (per ANSI/UL 61010-1), RoHS Compliant |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Lindberg/Blue M (Thermo Fisher Scientific) |
| Model | BF51748C-1 |
| Instrument Type | Box-Type Muffle Furnace |
| Max Temperature | 1100°C |
| Temperature Uniformity | ±2–4°C (at setpoint) |
| Max Power | 5600 W |
| Heating Rate (to 1100°C) | 6–12°C/min |
| Heating Method | Resistance Wire (Kanthal A1 alloy) |
| Internal Chamber Dimensions | 101.6 × 203.2 × 101.6 mm (H × D × W) |
| Chamber Volume | 1.99 L |
| Controller Type | Single-Setpoint Digital Controller |
| External Dimensions | 444.5 × 508 × 381 mm (H × D × W) |
| Net Weight | 25 kg |
| Safety Features | Automatic power cutoff upon door opening, adjustable overtemperature protection, K-type thermocouple (IEC 60584 compliant), dual-wall insulated housing |
| Gas Purge Ports | 25.4 mm (1") top exhaust port + 9.5 mm (0.375") rear inlet port |
| Standard Accessories | Moldatherm furnace tray, front-panel mounted power switch |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Lindberg/Blue M |
| Model | BF517xxC / BF518xxC Series |
| Chamber Volume | 1.99 L, 5.3 L, 18.4 L, or 42.5 L |
| Max Operating Temperature | 1100°C |
| Control Options | Digital Single-Setpoint or Multi-Step Programmable Controller |
| Power Supply | 208–240 V, 50/60 Hz |
| Heating Power | 1.8 kW (1.99–5.3 L), 3.5 kW (18.4 L), or 5.6 kW (42.5 L) |
| External Cooling Surface Temp | <60°C at 1100°C operation |
| Safety Features | Door-Interlocked Power Cut-off, Adjustable Over-Temperature Protection, K-Type Thermocouple |
| Gas Ports | 1" Top Exhaust + 3/8" Rear Inlet |
| Construction | Dual-Wall Insulated Steel Housing with Embedded Heating Elements |
| Compliance | Designed for GLP/GMP environments |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Horizontal Tube Furnace |
| Max Temperature | 1700°C |
| Temperature Uniformity | ±2–4°C |
| Max Power | 5000W (STF54434C) / 10000W (STF54454C) |
| Ramp Rate to Max Temp | 6–12°C/min |
| Heating Element | Silicon Molybdenum (MoSi₂) Rods |
| Chamber Internal Dimensions | 482.6 × 406.4 × 558.8 mm |
| Work Tube OD | 76.2 mm (3 in.) |
| Heating Zone Length | 304.8 mm (STF54434C) / 609.6 mm (STF54454C) |
| Controller | CC59256PCOM / CC59256PCOM2CKT |
| Thermocouple | Type B (Pt/Rh), 3 m (10 ft) lead with molded plug |
| External Dimensions (H×D×W) | 462.6×406.4×556.8 mm / 482.6×406.4×863.6 mm |
| Shipping Weight | 43 kg / 75 kg |
| Insulation | Dual-shell construction with convective air gap and high-purity alumina fiber insulation |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Tube Furnace |
| Max Temperature | 1100°C |
| Temperature Control Accuracy | ±2–4°C |
| Max Power | 3300 W |
| Ramp Rate (to Max Temp) | 6–12°C/min |
| Heating Method | Resistive Wire Heating |
| Internal Chamber Dimensions | 152.4 × 304.8 × 152.4 mm |
| Controller | Microprocessor-Based PID with Multi-Stage Ramp/Soak Programming |
| Thermocouple Type | K-Type |
| Optional Interface | RS485 Digital Communication Port |
| Insulation | Moldatherm™ High-Efficiency Ceramic Fiber with Hollow-Core Air Gap Design |
| Zone Configuration | Independent Three-Zone Heating & Control |
| Safety Features | Adjustable Over-Temperature Cut-Off, Dual-Redundant Thermal Protection |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Horizontal Tube Furnace |
| Model | STF55433C-1 |
| Max Temperature | 1500°C |
| Temperature Uniformity | ±2–4°C |
| Max Power | 6000 W |
| Ramp Rate (to Max Temp) | 6–12°C/min |
| Heating Element | Silicon Carbide (SiC) Rods |
| Internal Chamber Dimensions | 482.6 × 406.4 × 863.6 mm (W × H × L) |
| External Dimensions | 481.8 × 482.6 × 584.2 mm (H × D × W) |
| Voltage/Frequency | 208/240 V, 50/60 Hz |
| Net Weight | 123 kg |
| Controller | Single-Point Multi-Step PID Microprocessor |
| Thermocouple Type | Type R (Platinum/Rhodium) |
| Compatible Tube OD | 25.4–76.2 mm (1–3 inch) |
| Heating Zone Length | 304.8 mm |
| Operating Temp Range | 500–1500°C |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Tube Furnace |
| Max Temperature | 1100°C |
| Temperature Control Accuracy | ±2–4°C |
| Max Power | 800 W |
| Heating Rate (to Max Temp) | 6–12°C/min |
| Heating Method | Resistive Wire (Kanthal A1) |
| Internal Chamber Dimensions | 381 × 279.4 × 406.4 mm |
| External Dimensions (H×D×W) | 381 × 279.4 × 406.4 mm |
| Voltage/Frequency | 208–240 V, 50/60 Hz |
| Net Weight | 16 kg |
| Thermocouple Type | K-type |
| Controller Options | Single-Setpoint or Multi-Step Programmable Controller |
| Operating Tube ID | 25.4 mm |
| Heated Zone Length | 304.8 mm |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Benchtop Muffle Furnace |
| Model | M110 |
| Instrument Category | Box Furnace |
| Maximum Temperature | 1100°C |
| Temperature Uniformity | ±7°C |
| Control Accuracy | ±2–4°C |
| Max Power | 1400 W |
| Heating Rate (to 1100°C) | 6–12°C/min |
| Heating Method | Resistance Wire (Embedded in Grooved Ceramic Walls) |
| Internal Dimensions | 200 × 150 × 300 mm |
| Chamber Volume | 9 L |
| External Dimensions | 576 × 752 × 720 mm |
| Net Weight | 78 kg |
| Safety Certification | CE Marked |
| Insulation | Multi-layer Ceramic Fiber (Asbestos-Free) |
| Door Design | Horizontal Side-Opening |
| Thermal Architecture | Double-Wall Air-Gapped Casing |
| Over-Temperature Protection | Adjustable Limit Switch |
| Brand | Thermo Fisher |
|---|---|
| Origin | Imported |
| Manufacturer | Thermo Fisher Scientific |
| Model | MicroPure |
| Purified Water Grade | Type I (ASTM D1193-20) |
| Resistivity | 18.2 MΩ·cm @ 25°C |
| Total Organic Carbon (TOC) | 1–5 ppb |
| Endotoxin | < 0.001 EU/mL |
| Particles (>0.1 µm) | < 1 particle/mL |
| Flow Rate | ≤ 1 L/min |
| Dimensions (W×D×H) | 305 × 300 × 455 mm (without tank) |
| Power Consumption | 0.06 kW |
| Feed Water Requirement | RO/DI/distilled water with conductivity < 5 µS/cm, TOC ≤ 50 ppb, bacteria < 100 CFU/mL, turbidity < 1.0 NTU, temperature 2–35°C, pressure 0.1–6 bar |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Category | Imported Instrument |
| Model | Multidrop™ Pico 1 |
| Plate Formats Supported | 12-, 24-, 48-, 96-, and 384-well plates |
| Plate Height Range | 6–47 mm |
| Dispensing Accuracy | ≤8% CV |
| Dispensing Volume Range | 11 pL–20 μL or 1 nL–200 μL (dual-range configuration) |
| Throughput | 1 plate per run |
| Dimensions | 31 cm × 28 cm × 20 cm |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Category | Imported Instrument |
| Model | Multidrop™ Pico 8 Digital Dispenser |
| Plate Formats Supported | 12-, 24-, 48-, 96-, 384-, and 1536-well plates |
| Plate Height Range | 6–47 mm |
| Dispensing Accuracy | ≤8% CV |
| Dispensing Range | 11 pL–20 µL (8-channel pico-dispense cartridge), 1 nL–200 µL (4-channel cartridge) |
| Throughput | 8 samples per dispensing cycle |
| Dimensions | 47 cm × 38 cm × 23 cm |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Circulating Water Bath |
| Models | TSCIR19 / TSCIR35 / TSCIR89 |
| Bath Capacity | 19 L / 35 L / 89 L |
| Temperature Range | +5 °C to 100 °C |
| Temperature Stability | ±0.1 °C (±0.05 °C at 70 °C) |
| Circulation Type | Internal Recirculation |
| Control System | Microprocessor-Based PID Controller |
| Display | Icon-Driven Graphical LCD |
| Safety Features | Low-Level Fluid Detection, Audible Alarm, Over-Temperature Protection |
| Construction | Stainless Steel Bath Chamber with Removable Perforated Lid and Diffuser Tray |
| Power Rating | 1200 W (TSCIR19), 1500 W (TSCIR35 & TSCIR89) |
| Working Chamber Dimensions (L × W × H) | 305 × 387 × 192 mm (TSCIR19), 305 × 692 × 192 mm (TSCIR35), 483 × 914 × 241 mm (TSCIR89) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Origin Category | Imported |
| Model | 4105MAT |
| Pricing | Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Model | 88881004 |
| Speed Range | Adjustable, Typically 2–80 rpm |
| Construction | Corrosion-Resistant Anodized Aluminum Frame with Stainless Steel Rollers |
| Environmental Rating | Suitable for Humid Environments and CO₂ Incubators (5–95% RH, 5–50 °C) |
| Tube/Bottle Compatibility | Adjustable Roller Spacing for Tubes (10–50 mm OD) and Bottles (up to 250 mL) |
| Stacking Capability | Dual-unit vertical stacking supported via optional stack kit |
| Timer Function | Integrated digital timer (0.1–99.9 h) with auto-shutoff |
| Remote Control | Optional IR remote for operation inside incubators |
| Sealing Integrity | Includes silicone O-rings for secure, wobble-free rotation of capped tubes |
| Warranty | 90-day limited warranty from date of shipment per Thermo Fisher’s standard Terms and Conditions |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | ASE350 |
| Extraction Type | Solid-phase accelerated solvent extraction (ASE) |
| Pressure Range | 1500 psi |
| Temperature Range | Up to 200 °C |
| Flow Rate | 70 mL/min |
| Extraction Cell Volumes | 1, 5, 10, 22, 34, 66, and 100 mL |
| Solvent Options | Up to 3 solvents programmable per method |
| Solvent Consumption | <50 mL per 20 g sample (typical) |
| Automation Capacity | Up to 24 samples unattended |
| Compliance | Designed for GLP/GMP environments |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | BF51732 / BF51841 / BF51842 |
| Instrument Type | Box Furnace |
| Temperature Range | 100 °C to 1200 °C |
| Door Mechanism | Vertically Lifting Lid |
| Chamber Volume | 16.4 L |
| Control System | Integrated Digital Controller |
| Voltage/Frequency | 208–240 V, 50/60 Hz |
| Power Rating | 4500 W |
| Internal Dimensions (H×D×W) | 177.8 × 279.4 × 330.2 mm |
| Transport Weight | Approx. 130 kg |