| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ÄKTA ready™ |
| Pricing | Available Upon Request |
| Brand | Cytiva |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | BioProcess IC 1.5-inch |
| Pricing | Available Upon Request |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | OligoProcess™ |
| Synthesis Scale | 10–1800 mmol per run |
| Regulatory Compliance | FDA 21 CFR Part 11, GMP-ready architecture |
| Software Platform | UNICORN 7.x or later |
| Column Technology | Flow-through synthesis columns (compatible with ÄKTA oligopilot plus and OligoPilot 400) |
| Construction | Industrial-grade, explosion-proof certified components |
| Application Scope | Clinical-phase development through commercial-scale cGMP manufacturing |
| Brand | Cytiva |
|---|---|
| Origin | Japan |
| Model | Amersham Typhoon IP |
| Dynamic Range | >5 decades |
| Scan Area | 40 × 46 cm |
| Imaging Modes | Phosphor Imaging, Fluorescence (RGB), Near-Infrared (NIR), Optical Density (OD) |
| Detector Type | High-Sensitivity PMT-based Scanning System |
| Lens | Fujifilm Precision Optics |
| Compliance | Supports IQ/OQ Documentation, GLP/GMP-Ready Data Acquisition |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | WAVE 20/50 |
| Maximum Working Volume | 25 L |
| Tray Sizes | 5 L / 10 L / 25 L |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | ÄKTA readyflux |
| Type | Single-Use Tangential Flow Filtration (TFF) System |
| Application Scope | Lab-Scale to Pilot-Scale Bioprocessing |
| Control Software | UNICORN 7.x or later |
| Compatibility | DeltaV™ DCS, ReadyToProcess Hollow-Fiber Cartridges, Xcellerex XDUO Single-Use Mixers, Third-Party Bag Mixers |
| Regulatory Alignment | Designed for GLP/GMP environments |
| Brand | Cytiva |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | Xcellerex™ X-50 |
| Pricing | Upon Request |
| Application Domain | Biopharmaceutical Cell Culture |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | 29-0182-24 |
| Purification Principle | Affinity Chromatography (AC) |
| Detector Type | Xenon Lamp UV-Vis Detector |
| Absorbance Range | ±6 AU |
| Weight | 48 kg |
| Brand | Cytiva |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Omics Bundle |
| Separation Method | Automated |
| Cell Viability (%) | ≥90% |
| Compatibility | Requires Integration with VIA Freeze™ Uno Controlled-Rate Freezer |
| Intended Use | Research Use Only (RUO), Not for Diagnostic Purposes |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | ÄKTA™ start |
| Purification Principle | Affinity Chromatography (AC) |
| Gradient Type | Linear Gradient |
| Flow Rate Range | 0.5–5 mL/min |
| Flow Accuracy | ±15% at ≤1 mL/min |
| Flow Precision | ±15% at ≤1 mL/min |
| Detection | UV Monitor (280 nm single-wavelength), Conductivity Monitor |
| Pressure Range | 0–0.5 MPa |
| Conductivity Range | 0–300 mS/cm |
| Solvent Compatibility | Compatible with in-place cleaning using 1 mol/L NaOH and 2 mol/L NaCl for ≥3 hours per day |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | AKTA avant |
| Purification Principle | Affinity Chromatography (AC) |
| Detector Type | Xenon Lamp UV-Vis Detector |
| Detection Range | UV 190–700 nm |
| System Pressure Rating | Up to 20 MPa |
| Flow Rate Range | 0.001–20 mL/min (AKTA avant 25) |
| Conductivity Accuracy | ±0.01 mS/cm or ±2% |
| UV Absorbance Range | –6 to +6 AU |
| pH Measurement Range | 0–14 pH units (±0.1 pH accuracy, pH 2–12) |
| Temperature Control Range | 4–35 °C |
| Column Pressure Differential Monitoring | Dual integrated pressure sensors (pre- and post-column) |
| Buffer Preparation | Integrated BufferPro with quaternary valve, 26 preconfigured buffer recipes, real-time composition display |
| Software Platform | UNICORN 6 with FDA 21 CFR Part 11 compliance, audit trail, electronic signatures, role-based access control |
| Dimensions (L×W×H) | 860 × 710 × 660 mm |
| Weight | 116 kg |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | Biacore 1K SPR System |
| Configuration | Single-injection needle, six-flow-cell platform |
| Regulatory Readiness | Optional GxP-compliant software package (21 CFR Part 11 audit trail enabled) |
| Software | Biacore Insight™ v3.x |
| Service Support | OptiRun™ lifecycle service program |
| Upgrade Path | Compatible with Biacore 1K+ expansion module for enhanced ligand multiplexing and sample throughput |
| Brand | Cytiva |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Xcellerex APS |
| Pricing | Available Upon Request |
| Brand | Cytiva |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Xcellerex™ |
| Pricing | Available Upon Request |
| Brand | Cytiva |
|---|---|
| Origin | Japan |
| Model | Amersham Typhoon NIR / NIR+ |
| Instrument Type | Multicolor Fluorescent Gel Imaging System |
| Detection Principle | Confocal Laser Scanning with Dual-NIR Fluorescence Excitation and Emission Filtering |
| Laser Wavelengths | 685 nm, 785 nm |
| Emission Filters | IRshort 720BP20, IRlong 825BP30 |
| Scan Modes | Automatic, Semi-Automatic, Manual |
| Sample Formats | SDS-PAGE gels, agarose gels, nitrocellulose/PVDF membranes, microplates, Petri dishes, glass slides, tissue sections |
| Detector | Enhanced Photomultiplier Tube (PMT) optimized for NIR spectral range |
| Dynamic Range | >4 orders of magnitude (log-linear response) |
| Spatial Resolution | ≤50 µm (pixel size adjustable) |
| Software Platform | ImageQuant TL with GLP-compliant audit trail and 21 CFR Part 11 optional modules |
| Brand | Cytiva |
|---|---|
| Origin | Switzerland |
| Instrument Model | Sefia S-2000 |
| Type | Fully Automated |
| Regulatory Designation | Import (CE-marked for IVDR/MDR-compliant use in cell therapy manufacturing) |
| Single-Use Kit Compatibility | CT-300.1, CT-400.1 + PB-100.1, CT-200.1, CT-800.1, CT-350.1S |
| Software Integration | Chronicle™ v3.2+ with eSOP/eBMR and 21 CFR Part 11 / EU Annex 11 compliance |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | ÄKTA™ pure micro |
| Purification Principle | Gel Filtration Chromatography (GFC) |
| Gradient Type | Linear Gradient |
| Flow Rate Range | 0.001–25 mL/min |
| Flow Accuracy | ±1.2% (absolute), RSD <0.5% (0.25–25 mL/min, <3 MPa, 0.8–2 cP) |
| UV Detection Range | 190–700 nm (multi-wavelength) |
| Conductivity Range | 0.01–999.99 mS/cm |
| Optional pH Sensor | 0–14 pH, ±0.1 pH (pH 2–12) |
| Pressure Range | 0–20 MPa |
| Solvent Compatibility | Compatible with 1 mol/L NaOH and 2 mol/L NaCl for ≥3 h in-place cleaning |
| Internal System Volume | As low as 18 µL (with micro kit) |
| Microfluidic Components | 0.8 µL injection valve, 2.6 µL UV flow cell, 5.4 µL conductivity cell, 0.7 µL outlet valve, 0.6 mL mixer, tubing ID: 0.13 mm or 0.25 mm |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | UniFlux Tangential Flow Filtration System |
| Flow Rate Options | 10, 60, 120 L/min (400 L/min available on custom basis) |
| Vessel Capacity Range | 5–600 L (stainless steel or single-use mixing systems supported) |
| Automation Platform | UNICORN Software (21 CFR Part 11 compliant) |
| Application Scope | Microfiltration (e.g., cell harvest) and Ultrafiltration (e.g., protein concentration & diafiltration) |
| Brand | Cytiva |
|---|---|
| Origin | USA |
| Model | ReadyToProcess WAVE 25 |
| Maximum Working Volume | 25 L |
| Drive Mechanism | Motorized Rocking Platform with Adjustable Speed, Angle, and Motion Profile |
| Temperature Control | Integrated Heated Tray with Dual Independent PID Loops (Dual-Mode Operation) |
| Weight Measurement | Built-in Load Cells with Auto-Calibration Capability |
| Gas Transfer | Passive O₂/CO₂ Exchange via Sterile Vent Filters (Heated Exhaust Filter Included) |
| Data Storage | Dual Mirrored SSDs + UNICORN Database Integration |
| Communication Protocol | OPC UA Compliant |
| Compliance | Designed for GMP Environment |
| Brand | Cytiva |
|---|---|
| Origin | Switzerland |
| Model | NanoAssemblr™ Spark™ Instrument |
| Sample Volume Range | 25–250 µL |
| Mixing Technology | NxGen™ Microfluidic Vortex Mixing |
| Sterility Design | BSC-Compatible, Aseptic Operation Ready |
| Chip Type | Single-Use, Gamma-Irradiated Cartridge |
| Scalability Pathway | Seamless Transition to NanoAssemblr™ Ignite™ and NxGen™ Production Platforms |
| Regulatory Context | Designed for GLP-compliant early-stage development, supports 21 CFR Part 11–ready software integration (optional) |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | AKTAcrossflow |
| Application Scope | Lab-scale to process-development TFF for protein purification, cell harvesting, UF/DF, and membrane screening |
| Max Total Membrane Area | 150 cm² (3 × 50 cm² cassettes) |
| Minimum Working Volume | 25 mL |
| Control Software | UNICORN v7.x or later |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Fluid Path Materials | USP Class VI-certified elastomers, 316L stainless steel (pump head, valves), single-use compatible |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Biacore 1S+ SPR System |
| Instrument Type | Surface Plasmon Resonance (SPR) |
| Flow Cell Configuration | Six parallel flow cells |
| Detection Range | fM to mM |
| Sample Capacity | Up to two 96-well or 384-well microplates plus 21–43 additional sample positions |
| Analysis Time per Cycle | 2–15 minutes |
| Temperature Control Range | 4–37°C |
| Brand | Cytiva |
|---|---|
| Origin | Switzerland |
| Type | Fully Automated |
| Model | Sefia™ Automated Cell Expansion System |
| Compliance | CE-marked (2006/42/EC), IEC 61010, IEC 61326, ICES-001 Class A, China RoHS SJ/T11364-2014 |
| Software Compliance | Chronicle™ Viewer validated per GAMP™5 and FDA 21 CFR Part 11 |
| Operating Environment | 15–25°C, 20–80% RH (non-condensing), 840–1060 mbar, indoor use only, max. altitude 2000 m |
| Consumables | Single-use FEP or silicone-based disposable kits (e.g., Cat. No. 29716713, 29739346) |
| Integration | Compatible with Chronicle™ Viewer for audit-trail-enabled data management and real-time process monitoring |
| Brand | Cytiva |
|---|---|
| Origin | Japan |
| Model | Amersham ImageQuant 500 |
| Imaging Type | Chemiluminescence |
| CCD Resolution | 8.3 MP |
| Dynamic Range | 4.8 decades |
| Lens Aperture | f/0.14 (Fujifilm) |