Elemental Analyzer
Filter
Showing 151–180 of 531 results
| Brand | HACH |
|---|---|
| Origin | USA |
| Model | UVAS eco sc |
| Measurement Principle | UV Absorption at 254 nm |
| Output Parameter | Specific UV Absorbance (SAC₂₅₄) |
| Optical Design | Dual-beam |
| Probe Installation Options | Submersible or Flow-through |
| Automatic Cleaning | Integrated wiper system |
| Housing Material | Stainless steel (316L) |
| Compliance | Designed for ISO 7027-compliant turbidity compensation, supports EPA Method 415.3 principles, compatible with GLP/GMP data integrity workflows |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Model | HGA-100 |
| Instrument Type | Online Mercury Analyzer |
| Measurement Principle | Cold Vapor Atomic Absorption Spectrometry (CVAAS) |
| Sample Introduction | Solid/Liquid/Gas Direct Injection |
| Analysis Time | <5 min per sample |
| Sample Capacity | 40-position Autosampler |
| Reagent Consumption | Zero chemical reagents required |
| Temperature-Controlled Flow Path | Yes |
| Gold Amalgamation Trap | Nano-coated Au-Hg trap integrated |
| Catalyst System | Dual-stage composite catalyst |
| Exhaust Treatment | Integrated catalytic oxidation + activated carbon adsorption |
| Compliance Framework | Designed for GLP-compliant laboratories |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Model | HGM-200 |
| Instrument Type | Benchtop Laboratory Analyzer |
| Measurement Principle | Cold Vapor Atomic Absorption Spectrometry (CVAAS) |
| Detection Limit | ≤0.005 ng |
| Measurement Range | 0–15 ng (long-path absorption cell), 15–200 ng (short-path absorption cell) |
| Sample Throughput | 2.5 min per sample |
| Sample Capacity | 60-position autosampler tray |
| Compliance | ASTM D7623, EPA Method 7473, GB 5009.17-2021, HJ 923-2017, HJ 910-2017, SN/T series, ISO/IEC 17025-aligned operation |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Instrument Type | Benchtop Laboratory Analyzer |
| Measurement Principle | Cold Vapor Atomic Absorption Spectrometry (CVAAS) |
| Sample Throughput | 40-position or 120-position Automated Carousel Sampler |
| Integrated Carrier Gas Source | Yes |
| Gold Amalgamation Preconcentration System | Nano-coated Gold Trap |
| Dual-Beam Optical Design | Yes |
| Temperature-Controlled Absorption Cell | Yes |
| Compliance Standards | HJ 597–2011, HJ 543–2009, GB/T 17136–1997, DZ/T 0064.26–2021, USP <232>, ISO 17294-2, ASTM D6722-22 |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | D100 |
| Principle | Dumas combustion method |
| Nitrogen range | 0–500 mg N (absolute) or up to 100% N |
| Analysis time | 3–4 min per sample |
| Repeatability | RSD < 0.5% (EDTA standard, 9.57% N) |
| Sample mass | ≤1 g (solid) or ≤1 mL (liquid) |
| Recovery rate | >99.5% |
| Power rating | 2000 W |
| Dimensions (L×W×H) | 735 mm × 560 mm × 560 mm |
| Detector | Thermal conductivity detector (TCD) |
| Carrier gas | CO₂ (99.999% purity) |
| Oxygen purity | 99.999% |
| Combustion temperature | ~960 °C |
| Detection limit | 0.01 mg N |
| Weighing precision | ≤0.1 mg |
| Calibration | Linear or user-defined non-linear curve |
| Autosampler capacity | 120 positions |
| Operating environment | 5–30 °C, ≤85% RH, AC 220 V ±10%, 50 Hz |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | D200 |
| Analysis Principle | Dumas Combustion Method |
| Nitrogen Range | 0.1–500 mg |
| Sample Throughput | 3–4 min per sample |
| Repeatability | ≤0.5% RSD |
| Sample Mass | ≤1 g (solid) or ≤1 mL (liquid) |
| Recovery Rate | ≥99.5% |
| Power Consumption | 2000 W |
| Dimensions (L×W×H) | 735 mm × 560 mm × 560 mm |
| Detector | Thermal Conductivity Detector (TCD) |
| TCD Temperature Stability | ≤0.01 °C |
| Combustion Furnace Max Temp | 1200 °C |
| Carrier Gas | CO₂ (≥99.999% purity) |
| Oxygen Purity | ≥99.999% |
| Autosampler | 120-position single tray |
| Weight | 80 kg |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | D50 |
| Principle | Dumas Combustion Method |
| Nitrogen Range | 0.1–500 mg |
| Analysis Time | 3–4 min per sample |
| Repeatability | ≤0.5% RSD (using 150 mg of 10% N standard) |
| Sample Mass | ≤1 g (solid) or ≤1 mL (liquid) |
| Recovery Rate | >99.5% |
| Power Consumption | 2000 W |
| Dimensions (L×W×H) | 735 mm × 560 mm × 560 mm |
| Detector | Thermal Conductivity Detector (TCD) |
| Combustion Temperature | Up to 1200 °C |
| Carrier Gas | CO₂ (99.999% purity) |
| Oxygen Supply | High-purity O₂ (99.999%) |
| Autosampler Capacity | 1 × 60 positions |
| Calibration | Linear or user-defined non-linear curve |
| Communication Interface | RS485 (internal), RS232/USB (external) |
| Operating Environment | 15–30 °C, ≤85% RH |
| Weight | 80 kg |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | E500 |
| Measured Elements | C, H, O, N, S |
| Analysis Time | 3–4 min per element |
| Detection Limits | ≤30 ppm for C/H/N/S (TCD), ≤20 ppm for O (NDIR) |
| Measurement Accuracy | Absolute error ≤0.1% (10 mg standard sample) |
| Sample Mass | Up to 1.5 g or 1 mL liquid |
| Detector Configuration | TCD for C/H/N/S |
| Combustion Temperature | Up to 1400 °C |
| Autosampler Capacity | 120-position ceramic crucible tray |
| Gas Requirements | He (99.999%), O₂ (99.999%) |
| Dimensions (L×W×H) | 735 × 560 × 1160 mm |
| Net Weight | 100 kg |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | K1100 |
| Instrument Type | Kjeldahl Nitrogen Analyzer |
| Automation Level | Fully Automated |
| Nitrogen Determination Range | 0.1–240 mg N |
| Sample Weight Capacity | ≤5 g (solid), ≤20 mL (liquid) |
| Repeatability | ≤0.5% RSD |
| Recovery Rate | ≥99.5% |
| Steam Generation Control | Adjustable flow with real-time distillate temperature monitoring |
| Distillation Time | Programmable |
| Titration Resolution | 1.0 µL/step |
| Cooling Water Consumption | 1.5 L/min |
| Data Storage Capacity | 1800 test records |
| Power Supply | 220 V AC ±10%, 50 Hz |
| Rated Power | 2 kW |
| Dimensions (L×W×H) | 455 mm × 391 mm × 730 mm |
| Net Weight | 38 kg |
| Compliance | GB, NY, HJ, Chinese Pharmacopoeia, AOAC Official Methods, ISO 8968 & ISO 5983 |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | K1100 / K1100F |
| Nitrogen Range | 0.1–200 mg |
| Repeatability | ±0.5% |
| Sample Weight | ≤5 g (solid) / ≤20 mL (liquid) |
| Recovery Rate | ≥99.5% |
| Power Consumption | 2 kW |
| Dimensions (L×W×H) | 455 × 391 × 730 mm |
| Titration Resolution | 1.0 µL/step |
| Distillation Time | 5–10 min per sample |
| Data Storage Capacity | 1,000 (K1100) / 1,800 (K1100F) methods |
| Cooling Water Flow | 1.5 L/min |
| Operating Voltage | 220 VAC ±10%, 50 Hz |
| Net Weight | 38 kg |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | K1160 + K1124 |
| Instrument Type | Fully Automated Kjeldahl Nitrogen Analyzer |
| Nitrogen Determination Range | 0.1–240 mg N |
| Distillation Time | 2.8–3 min per sample |
| Repeatability (RSD) | ≤0.5% |
| Sample Weight Capacity | ≤5 g (solid), ≤20 mL (liquid) |
| Nitrogen Recovery Rate | ≥99.5% |
| Titration Resolution | 0.2 / 0.4 / 1.0 µL/step (selectable) |
| Power Consumption | 2 kW |
| Dimensions (L×W×H) | 460 × 360 × 725 mm |
| Net Weight | 38 kg |
| K1124 Autosampler | 24-position, 300 mL digestion tube capacity, integrated CAN interface, 24 VDC, 40 W, 920 × 625 × 908 mm, 80 kg |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | K1160 / K1160 + K1124 |
| Nitrogen Range | 0.1–240 mg |
| Distillation Time | 5–10 min/sample |
| Repeatability | ≤0.5% RSD |
| Sample Weight | ≤5 g (solid) or ≤20 mL (liquid) |
| Recovery Rate | ≥99.5% |
| Titration Resolution | 0.2, 0.4, or 1.0 µL/step (selectable) |
| Cooling Water Consumption | 0.5 L/min (at 15 °C inlet) |
| Power | 2 kW (K1160) |
| Dimensions (K1160) | 460 × 360 × 725 mm |
| Dimensions (K1124) | 920 × 625 × 908 mm |
| Net Weight (K1160) | 38 kg |
| Net Weight (K1124) | 80 kg |
| Data Storage | 1 million records (local), unlimited (cloud) |
| Compliance | FDA 21 CFR Part 11, GMP-aligned audit trail |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | K9840 |
| Nitrogen Determination Range | 0.1–240 mg N |
| Distillation Time | 0–60 min |
| Repeatability | ±0.5% |
| Sample Weight Capacity | ≤6 g (solid) / ≤16 mL (liquid) |
| Nitrogen Recovery Rate | ≥99.5% |
| Power Consumption | 1.3 kW |
| Dimensions (L×W×H) | 400 × 385 × 735 mm |
| Net Weight | 30 kg |
| Compliance | GB, NY, HJ, Chinese Pharmacopoeia, AOAC Official Methods, ISO 8968 & ISO 5983 |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | K9860 |
| Nitrogen Determination Range | 0.1 mg – 200 mg |
| Distillation Time | 5–10 min per sample |
| Repeatability | ±0.5% RSD |
| Sample Weight Capacity | ≤5 g (solid), ≤20 mL (liquid) |
| Nitrogen Recovery Rate | ≥99.5% |
| Power Consumption | 2 kW |
| Dimensions (L×W×H) | 455 mm × 391 mm × 730 mm |
| Touchscreen | 5.6-inch color LCD |
| Titration Resolution | 2.0 µL/step |
| Cooling Water Flow | 1.5 L/min |
| Data Storage | 1000 methods/results |
| Voltage | 220 VAC ±10%, 50 Hz |
| Net Weight | 38 kg |
| Brand | Hengmei |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Region | Domestic (China) |
| Model | HM-550 |
| Price | USD 25,000 (FOB Qingdao) |
| Measurable Elements | Na (11) to U (92) |
| Dimensions | 700 mm × 510 mm × 336 mm |
| Weight | 56 kg |
| Vacuum Chamber Dimensions | 400 mm × 340 mm × 80 mm |
| Operating Temperature | 15–30 °C |
| Relative Humidity | 40–70 % RH |
| Power Supply | AC 220 V ±5 V, 50/60 Hz |
| Detection Limit (RoHS elements) | 1 ppm |
| Measurement Time | 100–300 s (user-adjustable) |
| Energy Resolution | 129 ±5 eV (Mn Kα) |
| Detector | Silicon Drift Detector (SDD), Peltier-cooled |
| X-ray Tube | Max. 50 kV / 1 mA, tungsten anode |
| Vacuum Pump | 60 L/min, ultimate pressure 6.7×10⁻² Pa |
| Collimator Options | 7 fixed apertures (2–8 mm diameter) |
| Filter Options | 5 automatic filters |
| Spectral Channels | 4096-channel digital MCA |
| Interface | USB 2.0 |
| Brand | Hengmei |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Automated Kjeldahl Nitrogen Determinator |
| Automation Level | Fully Automated |
| Nitrogen Measurement Range | 0.1–240.0 mg N |
| Repeatability | ≤0.5% RSD (parallel determinations) |
| Sample Weight Capacity | ≤8.0 g (solid), ≤30.0 mL (liquid) |
| Nitrogen Recovery Rate | 99–101% |
| Power Consumption | ≤1500 W |
| Brand | Hiden |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | IG5C |
| Price | Upon Request |
| Ion Energy Range | 500 eV – 5 keV |
| Maximum Beam Current | 200 nA |
| Minimum Spot Size | 20 µm |
| Ion Source Lifetime | ~500 hours |
| Flange Type | DN-35 CF Conflat Wedge Flange |
| Power Consumption | 8 W |
| Filament Configuration | Dual-filament |
| Vacuum Compatibility | Optimized for UHV systems (<1×10⁻⁹ mbar) |
| Beam Blanking | Integrated electrostatic blanking for rapid beam on/off switching in grating applications |
| Brand | Hongtu |
|---|---|
| Origin | Shandong, China |
| Model | SP-6802 |
| Detection Limit (as S in H₂S) | 0.01 mg/m³ (Type A, non-conversion) |
| Measurement Range (as S in H₂S, undiluted) | 0.01–50 mg/m³ (extendable to 0.1–500 mg/m³) |
| Repeatability (RMS error) | <5% (n ≥10, certified H₂S standard gas or CS₂ permeation source) |
| Column Temperature Control | Ambient to 100°C ±0.2°C |
| Permeation Source Temperature Control | Ambient to 50°C ±0.1°C |
| Detector Temperature Control | Ambient to 110°C ±1°C |
| Converter Furnace Temperature | Ambient to 900°C ±5°C |
| High-Voltage Power Supply | –400 V to –800 V adjustable |
| Compliance | GB/T 19001–2016 (ISO 9001), GB/T 14001–2016 (ISO 14001) |
| Brand | Hongweiliangzi |
|---|---|
| Origin | Shandong, China |
| Model | HW-DYS2 |
| Measurement Channels | 6 |
| Sample Throughput | 20 consecutive samples |
| Analysis Time per Sample (8 elements) | ≤5 min |
| Stability | ±1 digit within 5 min |
| Compliance Standards | GB/T 4734, GB/T 6900, QB/T 2578–2002 |
| Operating Temperature | 10–30 °C |
| Relative Humidity | ≤85% |
| Power Supply | 220 V, 50/60 Hz |
| Power Consumption | 1 kW |
| Dimensions (Instrument) | 500 × 460 × 350 mm |
| Weight (Instrument + Packaging) | 15 kg |
| Brand | HORIBA |
|---|---|
| Origin | Imported |
| Manufacturer | HORIBA, Ltd. |
| Model | EMGA-Expert |
| Detection Principle | Pulse Heating Extraction + NDIR (CO/CO₂, H₂O) & TCD (N₂) |
| Gas Detection Methods | Non-Dispersive Infrared (NDIR) for O and H |
| Automation Options | Auto-Sampler, Auto-Crucible Loader, Auto-Electrode Cleaner, Halogen Trap |
| Compliance Support | ASTM E1019, ISO 14284, ISO 22356, JIS G 1257, USP <233>, FDA 21 CFR Part 11 (audit trail enabled), GLP/GMP-ready software architecture |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | EMIA-Expert |
| Pricing | Upon Request |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Heating System | High-Frequency Induction Furnace |
| Maintenance Interval | Up to 200 Analyses Without Service |
| Analysis Time | ≤70 Seconds per Sample |
| 清扫 Mechanism | Brushless Automatic Cleaning System |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Manufacturer Type | Manufacturer |
| Product Category | Imported Instrument |
| Model | EMIA-Pro |
| Measurement Principle | Infrared Absorption |
| Heating System | High-Frequency Induction Furnace |
| Measurement Range | C: 0.0002–6.0 wt% |
| S | 0.0002–1.0 wt% |
| Sensitivity | C: 0.01 ppm |
| S | 0.01 ppm |
| Accuracy | C: ±1 ppm or ±1.0% RSD |
| S | ±1 ppm or ±1.5% RSD |
| Analysis Time | 40 s |
| Origin | Sweden |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | XRF Scanner |
| Price Range | USD 27,000 – 68,000 (FOB) |
| Brand | JB |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | CS995 Advanced Digital Carbon-Sulfur Analyzer |
| Price | USD 16,800 (FOB Jiangsu) |
| Measurement Principle | Infrared Absorption Spectroscopy |
| Heating System | High-Frequency Induction Furnace (2.5 kW, 20 MHz) |
| Measurement Range | C: 0.0001–6.0000 wt% |
| S | 0.0001–0.5000 wt% |
| Sensitivity | 0.01 ppm (C and S) |
| Precision | ±1 ppm (RSD ≤ 0.5% at mid-range concentration) |
| Analysis Time | ≤35 seconds per sample (including combustion, gas purification, and IR detection) |
| Brand | JB |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | CS995 Carbon-Sulfur Analyzer |
| Price | USD 16,800 (FOB Jiangsu) |
| Measurement Principle | Electrolytic Conductivity Detection |
| Heating System | High-Frequency Induction Furnace (2.5 kHz, 20 kW) |
| Carbon Range | 0.0001–6.0000 wt% |
| Sulfur Range | 0.0001–0.5000 wt% |
| Sensitivity | 0.01 ppm (C and S) |
| Precision | ±1 ppm (RSD ≤ 0.5% at mid-range concentrations) |
| Analysis Time | ≤35 seconds per sample (including combustion, gas purification, and detection) |
| Brand | JB |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | CS995 |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Heating System | High-Frequency Induction Furnace (2.5 kHz, 3.5 kW) |
| Carbon Range | 0.0001–6.0000 wt% |
| Sulfur Range | 0.0001–0.5000 wt% |
| Sensitivity | 0.01 ppm (C and S) |
| Precision | ±1 ppm (RSD ≤ 0.5% at mid-range concentrations) |
| Analysis Time | ≤35 s per sample |
| Sample Weighing Range | 0.1–1.0 g (standard crucible mode) |
| Brand | Jiebo (JB) |
|---|---|
| Origin | Jiangsu, China |
| Model | TS6 |
| Power Supply | AC 220 V, 50 Hz |
| Display | 19-inch TFT True Color LCD |
| Operating Temperature | 0–50 °C |
| Operating Humidity | <76% RH |
| Power Consumption | 200 W |
| Measurement Time | 90 s |
| Cooling Curve Resolution | 0.1 °C (0–1370 °C) |
| CE Range | 2.30–4.83 wt%, ±0.10 wt% |
| C Range | 2.20–4.30 wt%, ±0.05 wt% |
| Si Range | 0.30–3.80 wt%, ±0.10 wt% |
| Spheroidization Rate (SG) | 60–95%, ±10.0% |
| Tensile Strength Range | HT100–HT350 |
| Data Storage Capacity | 5000 Measurements |
| Correction Offset Range | −0.99 to +0.99 for CE, C, Si |
| Brand | JBS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop Laboratory Analyzer |
| Principle | Cold Vapor Atomic Fluorescence Spectrometry (CVAFS) |
| Detection Limit | ≤0.003 µg/L |
| Repeatability (RSD) | ≤5% |
| Linearity Error | ±5% |
| Zero Drift | <0.2 mV |
| Measurement Range | 0.01–100 µg/L |
| Noise Level | <0.1 mV |
| Correlation Coefficient (Calibration Curve) | ≥0.996 |
| Operating Temperature | 5–35 °C |
| Relative Humidity | ≤80% |
| Environmental Requirements | Low-vibration, low-EMI, mercury-free ambient, well-ventilated location with external exhaust capability |
| Brand | Kaiyuanhongsheng |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Benchtop Laboratory Analyzer |
| Principle | Cold Vapor Atomic Absorption Spectrometry (CVAAS) with Thermal Decomposition |
| Detection Limit | 0.001 ng |
| Repeatability | RSD ≤ 1% at 1 ng |
| Linearity Error | ±3% across calibration range |
| Measurement Range | 0.005–1500 ng Hg per sample |