Environmental Monitoring Instruments
Filter
Showing 5011–5040 of 9112 results
| Brand | LANENDE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | Domestic (China) |
| Model | LD-JSD-3 Smart |
| Instrument Type | Handheld |
| Measurement Accuracy | ±0.1 %F·S |
| Operating Temperature Range | 0–40 °C |
| Processor Architecture | ARM Cortex-M3 |
| Operating System | Android-based firmware |
| Connectivity | Wi-Fi, GPS, GPRS (optional), USB-C interface |
| Display | 3.5-inch color touchscreen |
| Data Storage Capacity | Up to 5 million records |
| Data Export Format | CSV/Excel-compatible |
| Power Interface | Standard USB-C charging |
| Sensor Output | Real-time penetrometer force (N) and depth (mm) |
| Brand | LANENDE Intelligent Technology |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | LD-TPHn |
| Instrument Type | Portable |
| Functionality | Multi-parameter Soil Analyzer |
| pH Range | 0–14 |
| pH Resolution | 0.01 |
| pH Accuracy | ±0.1 |
| Dimensions | 204 × 100 × 36 mm (L × W × H) |
| Weight | 0.3 kg |
| Data Storage Capacity | 300,000 records |
| Display | Full-color LCD |
| Connectivity | USB + 4G cellular uplink |
| Software | Free PC-based data management suite with Excel export, curve plotting, and threshold-based color-coded alerting |
| Brand | Langbo |
|---|---|
| Model | ETC-1000A |
| Origin | Jiangsu, China |
| Instrument Type | Laboratory Water Sampler |
| Sampling Volume Range | 10–1000 mL per aliquot |
| Control Interface | Interactive Human-Machine Interface (HMI) |
| Programmability | Full Schedule-Based Automation (Time, Volume, Trigger-Based Sequencing) |
| Origin | Guangdong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | Langcheng Coastal Land-Based Pollutant Online Monitoring System |
| Pricing | Available Upon Request |
| Origin | Guangdong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | LC-SPA Single-Parameter Fully Automated Online Water Chemistry Analyzer |
| Price Range | USD 7,000 – 14,000 |
| Instrument Type | Online Water Quality Monitoring Analyzer |
| Measured Parameters | Total Nitrogen (TN), Total Phosphorus (TP), Total Iron (Fe), Total Zinc (Zn), Total Copper (Cu), Total Manganese (Mn), Total Chromium (Cr), Total Lead (Pb), Total Nickel (Ni), Total Silver (Ag), Total Aluminum (Al), Sulfide (S²⁻), Sulfate (SO₄²⁻), Ammonia-Nitrogen (NH₃-N), Nitrate (NO₃⁻), Nitrite (NO₂⁻), Orthophosphate (PO₄³⁻), Silicate (SiO₃²⁻), Chloride (Cl⁻), Hexavalent Chromium (Cr⁶⁺), Fluoride (F⁻), Chemical Oxygen Demand (COD), Total Organic Carbon (TOC) |
| Origin | Guangdong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | LS-DB300MM |
| Price | USD 3,500 (FOB Shenzhen) |
| Positioning System | GPS/BeiDou Dual-Mode GNSS |
| Communication | BeiDou Short Message Service (BDS-SMS) |
| Power Supply | Rechargeable Lithium-Ion Battery (≥12,000 mAh) |
| Operational Lifetime | 30–240 days (configurable sampling/transmission interval) |
| Beacon | High-Luminance LED Navigation Light (remotely activatable) |
| Payload Interface | RS-485 & Analog (0–5 V / 4–20 mA) for optional sensors (e.g., CTD, SST, DO) |
| Environmental Rating | IP68 submersion rating (up to 5 m), UV-stabilized polyethylene buoy hull |
| Dimensions | Ø300 mm × 420 mm (H), mass: 2.8 kg |
| Deployment Flexibility | Riverine, lacustrine, and coastal marine environments |
| Origin | Guangdong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | LS-DB300MM |
| Price | USD 2,800 (FOB Shenzhen) |
| Origin | Guangdong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | LangCheng Ocean Buoy Automatic Monitoring System |
| Pricing | Available Upon Request |
| Brand | Lanjing |
|---|---|
| Model | LJ-201 |
| Measurement Principle | Salicylate Spectrophotometry |
| Measurement Ranges | (0–5), (0–10), (0–25), (0–50), (0–125), (0–250) mg/L NH₃–N |
| Zero Drift | ±0.02 mg/L |
| Span Drift | ±1.0% F.S. |
| Accuracy | ±8.0% at 20% F.S., ±5.0% at 50% F.S., ±3.0% at 80% F.S. |
| Limit of Quantitation | 0.15 mg/L |
| Repeatability | ≤2.0% |
| Cycle Time | ≤60 min |
| MTBF | ≥720 h |
| Insulation Resistance | >20 MΩ |
| Output Interfaces | RS232 / RS485, 4–20 mA analog |
| Dimensions | 500 × 440 × 1440 mm (L×W×H) |
| Weight | 55 kg |
| Display | 7-inch color touch screen |
| Control System | Industrial PLC |
| Operating Temperature | 5–35 °C |
| Operating Humidity | 20–85% RH |
| Power Supply | AC 220 V ±25 V, 50 Hz ±0.5 Hz |
| Rated Power | 100 W |
| Brand | Lanjing |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | LJ-DC8000 |
| Price | USD 25,000 (FOB) |
| Measurement Principle | Enzyme-Substrate (β-D-galactosidase/ONPG) |
| Detection Range | 0–100 MPN/100 mL and 0–10,000 MPN/100 mL (extendable) |
| Sample Volume | 100 mL per analysis |
| Analysis Time | ≤24 h |
| Repeatability | ±5% |
| Accuracy (Standard Deviation) | ±20% |
| Drift | ±5% F.S. |
| Operating Temperature | 5–35 °C |
| Humidity Limit | <90% RH (non-condensing) |
| Enclosure Rating | IP66 / NEMA 4 |
| Dimensions (H×W×D) | 1675 × 630 × 610 mm (incl. reagent cabinet) |
| Power Supply | 220 V AC, auto-restart on power recovery |
| Data Storage | 100,000 records internal |
| Output Interfaces | 4–20 mA / 0–10 V analog, RS232, RS485 (Modbus RTU), Ethernet |
| Remote Capabilities | GPRS/4G, Wi-Fi, remote calibration & control |
| Sample Intake | Built-in peristaltic pump (suction head ≤2 m) |
| Reagent Consumption | 18 mL per test |
| Sample Consumption | ~100 mL per test |
| Compliance | Designed for ISO 9308-1, ASTM D5392, US EPA Method 1604, and GLP-aligned operational traceability |
| Brand | Lanjing |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | LJ-DCY |
| Price | USD 5,000 (FOB Qingdao) |
| Brand | Lanjing |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | LJ-DX |
| Instrument Type | Portable |
| Test Organism | Bioluminescent Bacteria (e.g., *Vibrio fischeri*, *Photobacterium phosphoreum*, *Aliivibrio qinghaiensis*) |
| Operating Temperature | +5°C to +45°C |
| Reagent Storage Temperature | −10°C to +50°C |
| Repeatability | Relative standard deviation <1% across three replicate measurements per sample |
| Assay Time | ≤15 minutes post-sample preparation |
| Spectral Response Range | 300–1100 nm |
| Detection Principle | Bioluminescence Inhibition Assay |
| Compliance | GB/T 15441–1995, ISO 11348-3 |
| Power Supply | AC 220 V / DC 12 V dual-mode |
| Battery | 6000 mAh Li-ion, >8 h continuous operation |
| Dimensions | 420 × 330 × 175 mm |
| Weight | 5 kg |
| Data Storage Capacity | ≥80,000 records |
| Connectivity | RJ45, Wi-Fi, 4G, Bluetooth, USB |
| Display | 7-inch capacitive touchscreen |
| Detector | Silicon Photomultiplier (SiPM) |
| Brand | Lanjing |
|---|---|
| Model | LJ-MDC |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Category | Domestic Instrument |
| Price | USD 13,600 (FOB) |
| Application | Enzyme-Substrate Method (Colilert®, Enterolert®, etc.) & Traditional Plate/Filtration Counting |
| Detection Targets | Total Coliforms, Fecal Coliforms, Escherichia coli, Enterococci, Pseudomonas aeruginosa, Total Viable Count (TVC) |
| Sample Formats | 51-well/97-well Quanti-Tray®, 84-well TVC tray, 90 mm Petri dishes, 45 mm membrane filters |
| Illumination | 8-channel tunable visible LED array (white + warm white), dual 365 nm narrow-band UV-LEDs |
| Imaging | 6.3 MP Sony Exmor back-illuminated CMOS sensor, 1/1.8″ format, 12-bit dynamic range, USB 3.0 interface |
| Enclosure | Fully sealed steel imaging chamber with matte black non-reflective interior |
| Data Management | Audit-trail-enabled software compliant with GLP/GMP principles, 21 CFR Part 11–ready configuration options |
| Operating System | Windows 10 Pro |
| Hardware | 13.3″ capacitive touchscreen all-in-one unit, Intel Core i7 CPU, 8 GB RAM, 512 GB SSD |
| Brand | Lanjing |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | LJ-PF1000 |
| CO₂ Range | 0–2000 ppm (customizable) |
| CH₄ Range | 0–100 ppm (customizable) |
| H₂O Range | 0–6% |
| CO₂ Precision | ±0.1 ppm @ 1 Hz |
| CH₄ Precision | ±10 ppb @ 1 Hz |
| H₂O Accuracy | ±1.5% of reading |
| Temperature Accuracy | ±0.1 °C (20–60 °C) |
| Sampling Flow Rate | 1 L/min (adjustable) |
| Chamber Dimensions | Ø220 mm × 120 mm H |
| Chamber Volume | 3140 cm³ |
| Battery Life | 8 hours (Li-ion) |
| Operating Temp. | −30 to +60 °C |
| Operating Humidity | <99% RH (non-condensing) |
| Weight | <10 kg |
| Data Output | Real-time flux & respiration rate calculation |
| Connectivity | Wi-Fi, BeiDou/GPS dual-mode (optional) |
| Expandability | 预留RS485, analog, and digital I/O ports for optional sensors (PAR, soil T/RH, anemometer, 4G telemetry) |
| Brand | Lanjing |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | LJ-QCMn54 |
| Instrument Type | Laboratory Benchtop Analyzer |
| Measurement Range | 0.05–5 mg/L KMnO₄ |
| Sample Volume | 100 mL |
| Sample Throughput | ≤5 min/sample |
| Detection Endpoint Resolution | 1 µL |
| Heating Temperature Accuracy | ±0.1 °C |
| Digestion Positions | 6 |
| Sample Capacity | 54 positions |
| Dimensions (L×W×H) | 1000 × 650 × 550 mm |
| Operating Ambient | 5–35 °C, 30–85% RH, 70–106 kPa, AC 220 V / 50 Hz |
| Brand | Lanjing |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | LJ-TZMn |
| Instrument Type | Benchtop Laboratory Analyzer |
| Detection Principle | Photometric Method (Formaldehyde Oxime & Potassium Periodate) |
| Target Analyte | Total Manganese (Mn) |
| Detection Range | 0–5 mg/L |
| Detection Limit | 0.1 mg/L |
| Accuracy | ≤ ±5% FS |
| Stability | < 0.5% (20 min) |
| Repeatability | < 0.5% RSD |
| Optical Drift | ≤ 0.002 A in 20 min |
| Light Source | Imported High-Brightness LED with Auto-Calibration |
| Cuvette Compatibility | 10 mm, 30 mm, 50 mm rectangular cuvettes & φ16 mm round tubes |
| Display | 8-inch TFT-LCD Touchscreen (1024 × 768) |
| OS | Android 7.1.1 |
| Data Storage | 8 million records |
| Connectivity | Wi-Fi, RJ45, Bluetooth, Mobile Hotspot, USB 2.0, HDMI |
| Cloud Platform | Integrated Regulatory Compliance Cloud (LAN/WAN upload |
| Printer | Built-in Thermal Line Printer (QR code supported) |
| Power Supply | AC 220 V ±10%, 50 Hz / Optional 6 Ah Li-ion Battery |
| Dimensions | 367 × 243 × 125 mm |
| Weight | 5.3 kg |
| Operating Environment | 5–40 °C, RH < 85% (non-condensing) |
| Rated Power | 10 W |
| Brand | Lanjing |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | LJ-YL01 |
| Instrument Type | Portable |
| Measured Parameters | Free Chlorine, Total Chlorine, Chlorine Dioxide |
| Measurement Ranges | 0.04–3 mg/L and 0.2–15 mg/L |
| Repeatability | <0.5% |
| Measurement Principle | Photometric Colorimetry (LED-based) |
| Wavelength Selection | Automatic |
| Display | 3.5-inch TFT Color Touchscreen |
| Operating System | Android-based Embedded OS |
| Data Storage Capacity | >80,000 records |
| Connectivity | USB Type-C, Wi-Fi, Bluetooth, Mobile Hotspot |
| Power Supply | 5 V DC / Internal 5600 mAh Rechargeable Li-ion Battery |
| Continuous Operation Time | Up to 8 hours |
| Dimensions | 180 × 80 × 70 mm |
| Weight | 700 g |
| Environmental Operating Range | 0–50 °C, 0–90% RH (non-condensing) |
| Optical Source | Imported Cold LED Light Source (Lifetime ≥100,000 h) |
| Compliance Reference | HJ 586–2010 |
| Brand | Lanjing |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | LJ-ZGSG |
| Instrument Type | Online Analyzer |
| Measurement Ranges | 0–30 ppb, 0–500 ppb, 0–5000 ppb |
| Accuracy | ±1% F.S. |
| Repeatability | ±1% F.S. |
| Drift | ≤±1% F.S. / 24 h |
| Response Time | 12 min (initial) |
| Sampling Cycle | ~10 min per channel |
| Sample Flow Rate | >100 mL/min |
| Sample Temperature | 10–45 °C |
| Sample Pressure | 10–100 kPa |
| Ambient Temperature | 5–45 °C |
| Relative Humidity | <85% RH |
| Reagent Consumption | ~3 L/month per reagent (3 reagents total) |
| Output | 4–20 mA (configurable, per-channel independent) |
| Alarm Output | Relay NO contact (220 VAC / 1 A) |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Power Consumption | ≈50 VA |
| Dimensions (H×W×D) | 720 × 460 × 300 mm |
| Panel Cutout | 665 × 405 mm |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Product Category | Atmospheric Heavy Metal Analyzer |
| Model | AOA 200 |
| Measurement Principle | X-ray Fluorescence (XRF) Spectrometry combined with β-ray Absorption and Automated Airborne Particulate Enrichment |
| Measurement Range | Heavy Metals: 0–100 µg/m³ |
| PM₂.₅/PM₁₀ Mass Concentration | 0–10 mg/m³ |
| Detection Limits | Heavy Metals: sub-ng/m³ level (1-hour sampling at 16.7 L/min) |
| Particulate Matter | <1 µg/m³ (24-hour average) |
| Filter Cartridge Lifetime | ~30 days under continuous hourly sampling mode |
| Operating Temperature | −40 °C to +50 °C |
| Operating Humidity | 0–90 %RH (non-condensing) |
| Ambient Pressure Range | 86–116 kPa |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | AOA 200CEMS |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Measurement Principle | Heated Extractive Sampling + Isokinetic Particulate Sampling + Energy-Dispersive X-Ray Fluorescence (ED-XRF) |
| Target Analytes | Pb, Cr, Cd, As, Hg, Ni, Zn, Cu, Mn, Sb (as particulate-bound species) |
| Sampling Interval | Programmable (default 15 min) |
| Data Output Interfaces | RS232/RS485, USB, GPRS, ADSL, Ethernet |
| Radiation Safety | Fully Shielded ED-XRF Module with <0.1 µSv/h external dose rate |
| QC Protocol | Internal Standard Element Monitoring for Drift Correction |
| Compliance Framework | Designed to support EPA Method 29 / ISO 14956 / HJ 657–2013 / HJ 93–2013 alignment |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Product Category | Atmospheric Heavy Metal Analyzer |
| Model | GaOA |
| Measurement Principle | X-ray Fluorescence (XRF) Spectrometry |
| Measurement Range | 0–100 µg/m³ |
| Detection Limit | 1 ng/m³ (1-hour sampling at 16.7 L/min) |
| Filter Tape Replacement Interval | One roll lasts ~30 days under hourly sampling |
| Operating Temperature | −40 °C to +50 °C |
| Operating Relative Humidity | 0–90% RH (non-condensing) |
| Ambient Pressure Range | 80–106 kPa |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM/ODM) |
| Product Category | Atmospheric Heavy Metal & Sulfur Compound Online Analyzer |
| Model | SPAS |
| Price Range | USD 140,000 – 210,000 (FOB Jiangsu) |
| Compliance | CE-marked for industrial environmental monitoring |
| Brand | LANTIAN |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Model | AOX- Organic Halogen Combustion Furnace |
| Compliance | HJ/T 83–2001, ISO 9562:1989, GB/T 15959–1995, GB 8978–1996, GB 3544–2008 |
| Sample Throughput | Up to 24 samples per batch (standard configuration) |
| Combustion Temperature Range | Ambient to 1100 °C (programmable, ±2 °C stability) |
| Gas Supply | Dual-gas system (N₂ for adsorption, O₂ for combustion) |
| Tube Material | High-purity quartz combustion tube (OD 15 mm, length 600 mm) |
| Integrated Scrubbing System | Five-stage acid/alkali wash bottles + dual absorption traps |
| Brand | LANTIAN |
|---|---|
| Model | AOX-C |
| Detection Principle | High-Temperature Combustion Coupled with Ion Chromatography |
| Compliance | HJ/T 83–2001, ISO 9562:1989, GB/T 15959–1995 |
| Combustion Temperature | Up to 1150 °C |
| Sample Introduction | Nitrogen-Pressurized Column Adsorption |
| Sample Mass Range | 5–1000 mg |
| Detection Range | 0.8–1000 µg/L (as Cl⁻ equivalent) |
| Analysis Time (instrumental) | 3–10 min per sample |
| Carrier Gas | O₂ ≥99.6% (recommended ≥99.999%) |
| Accessories Included | Integrated combustion furnace, quartz combustion tube, dual sample boats, quartz push rod, rubber end caps, adsorption column assembly (×2), 1.27 m silicone tubing (OD 15 mm), 5 scrubbing bottles, 2 absorption bottles, 2 absorption tubes, mounting fixtures,纱布,胶布,扎线 |
| Software Option | Real-time instrument control and quantitative data processing module (optional) |
| Brand | LANTIAN |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic Instrument |
| Model | AOX-C |
| Compliance | HJ/T 83–2001, ISO 9562:1989, GB/T 15959–1995 |
| Detection Method | Ion Chromatography (IC) of Inorganic Halides (Cl⁻, F⁻, Br⁻) after High-Temperature Combustion |
| Sample Matrix | Water (drinking, surface, groundwater, wastewater, seawater, treated effluent), sludge, sediment, soil, and waste oils |
| Key Components | Integrated furnace with built-in scrubbing system, quartz combustion tube, dual-zone oxygen supply, nitrogen-pressurized adsorption module, IC-compatible absorption train |
| Brand | LANTIAN |
|---|---|
| Model | AOX-C |
| Origin | Zhejiang, China |
| Manufacturer | LANTIAN Instrument Co., Ltd. |
| Application | AOX determination in water and solid matrices per HJ/T 83–2001, ISO 9562:1989, and GB/T 15959–1995 |
| Detection Method | High-temperature catalytic combustion followed by alkaline absorption and ion chromatographic quantification of F⁻, Cl⁻, Br⁻ |
| Sample Types | Drinking water, surface water, groundwater, wastewater, effluent, seawater, pulp mill discharge, soil, sediment, sludge, and waste oils |
| System Configuration | Integrated furnace with built-in scrubbing system, quartz combustion tube, dual-zone oxygen supply, nitrogen-driven adsorption module, standardized absorption train, and IC-compatible sample preparation workflow |
| Compliance | Designed to support GLP-compliant AOX testing workflows |
| Brand | LANTIAN |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Model | AOX-C |
| Compliance | HJ/T 83–2001, ISO 9562:1989, GB/T 15959–1995 |
| Detection Method | High-Temperature Combustion Coupled with Ion Chromatography (IC) |
| Measurable Species | AOX (as Cl), AOCl, AOF, AOBr |
| Sample Matrices | Drinking water, surface water, groundwater, wastewater, effluent, seawater, pulp mill discharge, soil, sediment, sludge, and waste oils |
| System Configuration | Integrated furnace with built-in gas scrubbing, dual-zone combustion tube, nitrogen pressurized adsorption unit, alkaline absorption train, and IC-ready halide quantification |
| Brand | LANTIAN |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic Instrument |
| Model | AOX-C Ion Chromatography-Based AOX Analyzer |
| Price | USD 4,200 (FOB Zhejiang) |
| Brand | LANYO |
|---|---|
| Origin | Beijing, China |
| Model | RT-S100 |
| Sampling Depth | 0–10 m |
| Host Weight | 20 kg |
| Core Diameter | 36 mm |
| Outer Diameter | 51 mm |
| Inner Diameter (Sampler Tube) | 41 mm |
| Vibration Frequency | 1720 cycles/min |
| Power Source | 1.6 HP gasoline engine |
| Fuel Consumption | 0.6 L/h |
| Sampling Rate | ≥1.1 m/min |
| Sample Recovery Rate | >97% |
| Sampling Method | Vertical impact-driven coring with single-use inner liner |
| Extraction Mechanism | Integrated hydraulic + mechanical extraction assist |
| Transport Configuration | Wheeled mobile cart assembly |
| Brand | LANYO |
|---|---|
| Origin | Beijing, China |
| Model | RT-S300 |
| Sampling Depth | 0–15 m (up to 20 m in soft soils) |
| Host Weight | 27 kg |
| Sampling Method | Hydraulic Impact |
| Core Diameter | 36 mm |
| Outer Diameter | 51 mm |
| Sample Recovery Rate | >97% |
| Hammering Frequency | 1400 bpm |
| Hydraulic Oil Capacity | 6.5 L |
| Pull-Out Force | 16.5 tonnes |
| Sampling Speed | up to 1.5 m/min |
| Sampling Principle | Single-Use Liner-Based Impact Coring |
| Mobility | Integrated Wheeled Cart System |
| Compliance | Designed for ASTM D1586, ISO 22475-1, and GB/T 50123-2019 soil sampling protocols |
