Flow Cytometer
Filter
Showing 31–60 of 88 results
| Brand | Beckman Coulter |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic IVD Instrument |
| Model | DxFLEX |
| Product Category | Clinical Flow Cytometry System |
| Application Domain | In Vitro Diagnostic (IVD) Laboratories |
| Laser Configuration | 3 Lasers / 13 Fluorescence Parameters |
| Fluorescence Sensitivity | ≤30,000 Equivalent Stained Particles (ESPs) |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Model | EPICS XL / XL-MCL |
| Product Type | Flow Cytometry Analyzer |
| Regulatory Classification | Imported Instrument |
| Software Platform | System II™ |
| Detection Capability | 4-color fluorescence, multi-parameter analysis |
| Sample Throughput (XL-MCL) | Up to 100 samples/hour |
| Fluidics Architecture | Closed-system design with pre-aspirational mixing and barcode-enabled tri-channel positive sample identification |
| Optical Configuration | Interchangeable filter sets for flexible assay configuration |
| Compliance Framework | Designed for GLP/GMP-aligned workflows |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Model | Gallios |
| Product Type | Flow Cytometry Analyzer |
| Category | Cell Analysis Instrument |
| Import Status | Imported |
| Distribution Model | Authorized Distributor |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Model | MoFlo XDP |
| Product Category | High-Performance Flow Cytometry-Based Cell Sorting System |
| Sample Size Range | 0.5–50 µm |
| Maximum Analysis Rate | >100,000 cells/sec |
| Maximum Sorting Rate | >70,000 cells/sec |
| Fluorescence Parameters | Up to 18 colors + 2 scatter channels (with multi-laser configuration) |
| Sorting Output | 4-way simultaneous sorting |
| Nozzle Options | 8 interchangeable nozzles (50–200 µm) |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Navios EX |
| Technology Platform | Spectral Flow Cytometry |
| Instrument Type | Clinical-Grade Flow Cytometer |
| Laser Configuration | Up to 3 Lasers |
| Detection Channels | 12 |
| Forward Scatter (FSC) Collection Modes | Wide (1–18°), Narrow (1–8°), Wide Enhanced (optimized for submicron particles) |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Navios |
| Product Category | Flow Cytometry Analyzer |
| Intended Use | Clinical Diagnostics |
| Lasers | 405 nm (violet), 488 nm (blue), 638 nm (red) |
| Detection Channels | Up to 10-color capability |
| Fluorescence Sensitivity | <112 MESF (FITC), <78 MESF (PE), <15 MESF (PC5) |
| Forward & Side Scatter Detection | Photodiode-based FSC/SSC |
| Fluorescence Detection | Photomultiplier Tube (PMT)-based |
| Optical System | Solid-state diode lasers with integrated flow cell |
| Flow Cell Dimensions | 150 µm × 460 µm rectangular quartz cuvette |
| Temperature Control | Integrated thermal regulation for optical path stability |
| Data Processing | Real-time digital signal processing |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Regulatory Certification | China NMPA Import Registration No. 20172401770 |
| Compliance | Designed for CLIA- and CAP-aligned clinical laboratories |
| Brand | Beckman Coulter |
|---|---|
| Model | Vi-CELL XR |
| Origin | USA |
| Product Type | Automated Cell Viability and Counting System |
| Sample Volume Range | 0.5–100 µL |
| Cell Size Detection Range | 2–700 µm |
| Imaging Sensor | 1394 × 1040 CCD array |
| Interface | IEEE 1394 (FireWire) |
| Focus Mechanism | Motorized Auto-Focus |
| Reagent Kits Available | Vi-CELL XR Quad Pack, Vi-CELL AS/S Quad Pack |
| Calibration Standards | Vi-CELL Concentration Control, Vi-CELL Focus Control |
| Data Export Format | Native Excel (.xlsx), CSV, TIFF image archives |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | S3e |
| Product Type | Flow Cytometric Cell Sorter |
| Lasers | 3 lasers (405 nm, 488 nm, 640 nm) |
| Fluorescence Detection Channels | 6 parameters (4 fluorescence + FSC + SSC) |
| Coefficient of Variation (CV) | ≤2.5% for FITC beads |
| Sorting Speed | Up to 100,000 events/sec |
| Sensitivity | ≥125 MESF (Molecules of Equivalent Soluble Fluorochrome) for FITC |
| Sample Temperature Control | 4–35 °C adjustable, ±0.5 °C stability |
| Nozzle Sizes | 70 µm, 85 µm, 100 µm |
| Auto-Calibration | Fully automated hydrodynamic and optical alignment via AutoGimbal™ system |
| Biosafety Compatibility | Certified for operation inside Class I biosafety cabinets |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | ZE5 |
| Product Type | Flow Cytometer |
| Application | Research |
| Lasers | 5 lasers |
| Detection Parameters | 30 parameters |
| Coefficient of Variation (CV) | ≤3% |
| Sample Flow Rate | 3.5 µL/min |
| Fluorescence Sensitivity | ≤10 MESF (Molecules of Equivalent Soluble Fluorochrome) for FITC |
| Event Acquisition Rate | Up to 100,000 events/sec |
| Maximum Data Storage per Acquisition | 100 million events |
| Throughput | 96-well plate in ≤12 minutes |
| Fluidic Velocity | 8 m/sec |
| Software | Everest Flow Cytometry Software |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | ZOE |
| Product Category | Integrated Fluorescent Cell Imaging System |
| Excitation/Emission Filters (Blue Channel) | 355/40 nm / 433/36 nm |
| Excitation/Emission Filters (Green Channel) | 480/17 nm / 517/23 nm |
| Excitation/Emission Filters (Red Channel) | 556/20 nm / 615/61 nm |
| Imaging Sensor | 5 MP, 12-bit CMOS monochrome camera |
| Display | 10.1-inch high-resolution LCD touchscreen (1280 × 768) |
| Objective | 20× achromatic, wide-field mounting (0.70 mm² FOV, ~180% larger than standard 20×) |
| Stage | Motorized XY stage with ±6 mm travel, touch-controlled navigation |
| Illumination | LED-based brightfield (adjustable green LED ring with quadrant masking for oblique illumination) and fluorescence excitation (no warm-up, >10,000 h lifetime) |
| Image Storage | 16 GB internal memory (~2,500 JPEG images) |
| Output Formats | JPEG, TIFF, RAW |
| Software Features | Real-time gain, exposure time, LED intensity, and contrast adjustment |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Agile Pulse In Vivo |
| Product Category | In Vivo Electroporation System |
| Voltage Range | 50–1000 V |
| Pulse Duration | 5 µs – 10 ms |
| Inter-Pulse Interval | 20 µs – 1 s |
| Data Export | USB Storage |
| Operating Temperature | 10–40 °C |
| Input Voltage | 100–250 VAC |
| Dimensions (L×W×H) | 32.0 × 20.0 × 39.9 cm |
| Weight | 11.34 kg |
| Electrode Compatibility | Multi-needle Matrix Electrodes (Subcutaneous & Intramuscular) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Agile Pulse Max |
| Product Type | Cell Analysis System |
| User Interface | Color Touchscreen |
| Voltage Range | 50–1200 V |
| Pulse Duration | 5 µs – 10 ms |
| Inter-Pulse Interval | 20 µs – 1 s |
| Data Export | USB Flash Drive |
| Operating Temperature | 10–40 °C |
| Input Voltage | 100–250 VAC |
| Dimensions (L×W×H) | 32.0 × 20.0 × 39.9 cm |
| Weight | 11.34 kg |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ECM 399 |
| Price Range | USD $13,500 – $40,500 (FOB) |
| Product Type | Electroporation System for Cell Transfection and Transformation |
| Brand | BTX |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | ECM 630 |
| Price Range | USD $13,500 – $40,500 (FOB US Port) |
| Product Type | Electroporation System for Cell Transfection and Transformation |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | ECM2001 |
| Price Range | USD 14,000 – 43,000 |
| Product Category | Cell Analysis System |
| AC Parameters | Non-sinusoidal waveform, 1 MHz frequency, 0–75 V amplitude, 0–99 s duration, AC/DC inter-pulse interval 50 µs |
| DC Parameters (High-Voltage Mode) | 10–3000 V (10 V step), pulse width 1–99 µs (1 µs step) |
| DC Parameters (Low-Voltage Mode) | 10–500 V (10 V step), pulse width 1–99 ms (1 ms step) or 10–990 µs (10 µs step) |
| Pulse Count | 1–9 pulses per train |
| Inter-Pulse Interval | 1 s |
| Cycle Count | 0–9 cycles |
| Minimum Load Impedance | 20 Ω |
| Electrode Compatibility | All BTX electrodes except 35 mm dish electrodes |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | cellenONE F1.1 |
| Product Type | Automated Single-Cell Dispensing System |
| Application Domain | Research |
| Laser Excitation Efficiency | 95% |
| Detection Channels | 3 |
| Optical Resolution (Spatial) | 200 nm |
| Fluorescence Sensitivity Threshold | ≥10,000 cells/s |
| Cell Processing Throughput | 0.2 cells/s (single-cell validation rate) |
| Core Technology | Piezoelectric Acoustic Droplet Ejection (ADE) with Real-Time Optical Monitoring |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | cellenONE |
| Product Category | Flow Cytometry-Based Single-Cell Dispenser |
| Application Domain | Research |
| Laser Efficiency | 95% |
| Detection Channels | 3 |
| Optical Resolution | 200 nm |
| Fluorescence Sensitivity | 10,000 cells/s |
| Cell Dispensing Throughput | 0.2 wells/s |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | f1.4 |
| Detection Channels | 3 |
| Fluorescence Sensitivity | 10,000 cells/s |
| Cell Analysis Speed | 0.2 mL/min |
| Detection Resolution | 200 µm |
| Laser Efficiency | 95% |
| Product Type | Flow Cytometry-Based Single-Cell Isolation Platform |
| Compatible Collection Formats | 96-well, 384-well, 1536-well, and custom microplates |
| Reagent Dispensing Precision | Nanoliter (nL)-level |
| Single-Cell Isolation Accuracy | ≥95% |
| Minimum Input Volume | 5 µL |
| Minimum Viable Cell Input | 50 cells |
| Cell Viability Post-Isolation | >90% (vs. typical FACS: 70–85%) |
| Brand | KELLER HCW |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | SAMPLER1 |
| Pricing | Available Upon Request |
| Product Type | Flow Cytometer |
| Spectral Detection Range | 420–832 nm |
| Dynamic Range | 10⁷·² (log scale) |
| Fluorescence Sensitivity | High |
| Resolution | High |
| Linearity | ≥0.99 |
| Continuous Sample Loading Duration | Up to 30 min |
| Temperature Control | Precise |
| Vibration Damping | Integrated |
| Optical-Electronic Module | Modular Design |
| Brand | CytoBuoy (Netherlands) |
|---|---|
| Origin | Netherlands |
| Model | CytoBuoy |
| Application Platform | Buoy-Integrated Autonomous Monitoring System |
| Detection Principle | Pulse-Shape Analysis (PSA) + High-Speed Flow Imaging Cytometry |
| Optical Channels | FWS, SWS, FLR, FLY, FLO |
| Depth Rating | Up to 20 m (with CytoSub module) |
| Data Transmission | Wireless (GSM/3G/4G, optional satellite) |
| Compliance | Designed for GLP-aligned environmental monitoring workflows |
| Software | CytoUSB (acquisition), CytoClus & EasyClus (batch clustering & morphometric analysis) |
| Particle Size Range | 1–500 µm |
| Measurement Modes | In situ profiling (with CTD), vertical剖面, remote-controlled unattended operation |
| Brand | CytoBuoy (Netherlands) |
|---|---|
| Origin | Netherlands |
| Model | CytoSense XR |
| Detection Principle | Laser-scanning flow cytometry with hydrodynamic focusing and synchronized high-resolution imaging |
| Particle Size Range | 0.2–700 µm |
| Concentration Range | 10²–10¹¹ particles/L |
| Sheath Fluid System | Closed-loop recirculating |
| Optical Channels | Forward scatter (FWS), red fluorescence (FLRed, ~680 nm), side scatter (optional), multi-wavelength excitation (488 nm standard, optional 532/640 nm) |
| Imaging Mode | Pulse-profile scanning + triggered micrograph acquisition |
| Data Output | Per-particle parameter vectors (size, shape, pigment distribution, internal structure morphology), time-stamped event files, TIFF/JPEG image stacks |
| Compliance | Designed for GLP-compliant environmental monitoring |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Model | CytoFLEX nano |
| Particle Detection Range | 40 nm – 1 µm |
| Fluorescence Channels | 6 |
| Scatter Channels | 6 |
| Automated Sample Loading | Yes |
| Software | FCMpass (licensed) |
| Carryover Rate | <1% |
| Intended Use | Research-Grade Nanoparticle & Submicron Vesicle Analysis |
| Regulatory Context | Designed for GLP-compliant lab environments |
| Brand | Beckman Coulter |
|---|---|
| Origin | Jiangsu, China (Manufactured under Beckman Coulter’s global quality system) |
| Type | Analytical Flow Cytometer |
| Laser Configuration | 1–3 lasers (violet 405 nm, blue 488 nm, red 638 nm) |
| Detection Channels | Up to 13 parameters (including FSC, SSC, and fluorescence) |
| Optical Resolution | rCV < 3% across all channels |
| side scatter resolution | < 300 nm (488 nm laser), < 80 nm (405 nm laser) vs. polystyrene beads |
| Flow Rate | Fixed settings at 10, 30, and 60 µL/min |
| user-defined range | 10–240 µL/min |
| Fluorescence Sensitivity | ≤30 MESF (FITC), ≤10 MESF (PE) at 15-parameter configuration |
| Throughput | Up to 30,000 events per second (EPS) |
| Automation | Integrated autosampler with plate loader (96-/384-well compatible) |
| Compensation | Real-time automated compensation (spillover matrix-based) |
| Sorting Capability | Optional integrated cell sorting module (12-way sorting) |
| Voltage Control | User-adjustable PMT voltage per detector |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | CytoFLEX SRT |
| Price Range | USD $15,000–$120,000 (FOB) |
| Technology Platform | Sorting Flow Cytometry |
| Product Type | High-Performance Benchtop Flow Cytometer with Integrated Cell Sorting |
| Intended Use | Research-Only |
| Sample Delivery Rate | 10–100 µL/s (continuously adjustable) |
| Sorting Output | 4-way electrostatic sorting |
| Voltage Adjustment Required | Yes |
| Optical Configuration | V-B-Y-R (Violet-Blue-Yellow-Green-Red) up to 15 fluorescence detectors |
| Biosafety Options | Optional aerosol containment system compatible with Class II biological safety cabinets |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | TAXIScan-FL |
| Price Range | USD 140,000 – 280,000 (FOB Japan) |
| Product Category | Live-Cell Chemotaxis Analysis System |
| Application Domain | Academic & Preclinical Research |
| Excitation Source | None (Requires External Fluorescence Illumination) |
| Detection Channels | 1 (Single-Channel Fluorescence + Brightfield) |
| Spatial Resolution | ≤30 µm |
| Fluorescence Sensitivity | ≥0.1 ng/mL (FITC-equivalent) |
| Imaging Throughput | Up to 12 Concurrent Assays |
| Sample Requirement | As Few as 100 Viable Cells per Assay |
| Temperature Control Range | RT + 3°C to 40°C |
| Microchannel Depths | 4, 5, 6, or 8 µm |
| Objective Lenses | 10×, 20×, 40×, 100× (Oil Immersion Compatible) |
| Filter Sets | Standard B/G/R Cube Configuration |
| Data Output Format | TIFF/AVI Time-Lapse Sequences with Metadata Embedding |
| Software Compliance | FDA 21 CFR Part 11–Ready Audit Trail, GLP-Compliant Experiment Logging |
| Origin | United Kingdom |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LC-AMF System |
| Product Category | Live-Cell Time-Lapse Imaging & Electromagnetic Field Exposure Platform |
| CO₂ Input | 5% (v/v) |
| Recirculating Water Bath Flow Rate | 320 mL/min |
| Temperature Stability | ±0.2 °C |
| Max Frequency | 951.5 kHz (at 13.2 mT) |
| Min Frequency | 128.8 kHz (at 20 mT) |
| Dimensions | 127 × 85 × 26 mm |
| Compatible Vessel | 35 mm Tissue Culture Dish |
| Frequency Tuning Range | 128.8–951.5 kHz (dependent on inductance/capacitance matching) |
| Brand | FuTech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | SN415 |
| Pricing | Upon Request |
| Technology Platform | Nanoscale Flow Cytometry |
| Instrument Type | High-Parameter Flow Cytometer with Sorting Capability |
| Intended Use | Research-Only |
| Laser Configuration | Up to 4 Lasers |
| Detection Channels | 2 Scatter (FSC/SSC) + Up to 13 Fluorescence Parameters |
| Acquisition Rate | 10,000 Events per Second |
| Compensation | Automated and Manual Compensation Support |
| Nozzle Sizes | 70 µm, 85 µm, 100 µm, 130 µm |
| Sorting Capability | Yes |
| Sorting Throughput | 10,000 Events per Second |
| Sorting Output | 4-Way Sorting |
| Voltage Adjustment Required | Yes |
| Brand | Merck |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | easyCyte 8 |
| Product Category | Flow Cytometer |
| Laser Configuration | Dual-laser (488 nm blue + 635 nm red) |
| Fluorescence Channels | 6 (Green, Yellow, Red1, Red2, NIR1, NIR2) + 2 Scatter (FSC, SSC) |
| Sample Format | 1.2 mL or 1.5 mL microtubes |
| Software Platform | guava InCyte v3.x |
| Brand | Merck |
|---|---|
| Origin | USA |
| Manufacturer | Merck KGaA, Darmstadt, Germany |
| Product Type | Benchtop Flow Cytometer |
| Laser Configuration | 488 nm Blue Laser + 638 nm Red Laser |
| Fluorescence Channels | 6 (Green, Yellow, Red1, Red2, NIR1, NIR2) + 2 Scatter (FSC, SSC) |
| Detection Optics | High-Transmission Bandpass Filters (e.g., 525/30 nm, 583/26 nm, 692/46 nm, 661/19 nm, 785/70 nm ×2) |
| Sample Format | 96-Well Microplate (Standard ANSI/SLAS), 1.2–1.5 mL Tubes |
| Automation | Integrated 96-Well Plate Autoloader |
| Software | Guava InCyte v3.x (FDA 21 CFR Part 11–Ready, Audit Trail Enabled, GLP/GMP-Compatible Workflow Support) |
| Brand | Instec |
|---|---|
| Origin | USA |
| Model | HCS60 |
| Temperature Range | 5 °C to 60 °C (optional up to 95 °C) |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.1 °C at 37 °C |
| Max. Heating Rate | +50 °C/min at 37 °C |
| Max. Cooling Rate | −50 °C/min at 37 °C |
| Min. Heating/Cooling Rate | ±0.1 °C/hour |
| Control Method | PID with Variable Bipolar DC Control |
| Sensor | 100 Ω Platinum RTD |
| Working Distance | 5.6 mm (with optional insert) |
| Condenser Distance | 19.1 mm |
| Sample Area | 35 mm diameter |
| Chamber Height | 19 mm |
| Viewing Aperture | 13 mm (with insert), 20 mm (without insert) |