Flow Cytometer
Filter
Showing 61–88 of 88 results
| Brand | JJD |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | JD-S |
| Price Range | USD 14,000–42,000 |
| System Type | Integrated Cell Observation Platform |
| Workbench Surface Finish | 8K Mirror-Polished Stainless Steel |
| Optical Magnification | 7×–180× |
| Video Magnification | 460× |
| Monitor Size | 17-inch LCD |
| Cold Light Source | 150 W, 21 V, 60 Hz, Uniformly Adjustable Intensity |
| Power Supply | 220 V, 50 Hz |
| Bench Dimensions | 1000 × 600 × 800 mm |
| Temperature Stability | Continuous operation at 37 °C ambient |
| Imaging Capability | Real-time capture, time-lapse recording, digital archiving |
| Stage Motion | Motorized X-Y translation platform |
| Objective Lenses | Standard 10× (optional 5× and 40×) |
| Camera | High-resolution digital CCD sensor |
| Illumination | Fiber-optic cold light delivery |
| Software Control | PC-based acquisition and annotation suite |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | Kaluza |
| Product Type | Flow Cytometry Data Analysis Software |
| Intended Use | Research-Grade Flow Cytometry Data Processing |
| Minimum Display Resolution | 1440×900 |
| File Format Support | FCS 2.0/3.0/3.1, LMD |
| Operating System | Windows 7 (64-bit) and later |
| Brand | Merck |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | CellStream |
| Product Type | Flow Cytometry Analyzer |
| Lasers | Up to 7 (configurable) |
| Detection Channels | 22 |
| Fluorescence Sensitivity (MESF) | FITC < 10, PE < 5 |
| Flow Rate | 3.66–14.64 µL/min |
| Fluorescence Detection Limit | 20,000 events/sec |
| Cell Analysis Throughput | FITC MESF < 10, PE MESF < 5 |
| Detector Technology | Time-Delay Integration CCD (TDI-CCD) |
| Brand | Merck |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | guava easyCyte 6-2L |
| Product Type | Flow Cytometer |
| Sample Vial Format | 1.2 mL or 1.5 mL microtubes |
| Fluorescence Channels | Red2 (661/19 nm), Red1 (690/50 nm), Yellow (583/26 nm), Green (525/30 nm) |
| Excitation Lasers | 488 nm blue laser, 638 nm red laser |
| Parameters Measured | 6-parameter (4 fluorescence + 2 light scatter) |
| Brand | Merck |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | guava easyCyte 6HT-2L |
| Pricing | Upon Request |
| Brand | Merck |
|---|---|
| Origin | USA |
| Manufacturer | Merck Millipore (acquired Amnis) |
| Product Type | Imported Instrument |
| Model | FlowSight |
| Pricing | Available Upon Request |
| Brand | Merck |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Import Category | Imported |
| Model | Muse |
| Product Type | Flow Cytometry-Based Cell Analyzer |
| Pricing | Available Upon Request |
| Brand | NARISHIGE |
|---|---|
| Model | IM-300 |
| Origin | Japan |
| Operating Pressure Range | Up to 7 kgf/cm² (≈686 kPa) |
| Power Consumption | ~35 W |
| Dimensions | 425 × 205 × 90 mm (W × D × H) |
| Weight | 3.7 kg |
| Includes | Inlet/Outlet Tubing, Foot Switch, Silicone Gasket, Power Cord, HI-7 Microinjector Holder |
| Brand | Merck |
|---|---|
| Origin | USA |
| Manufacturer | Merck KGaA |
| Product Type | Epithelial Resistance & Voltage Measurement System |
| Model | Millicell® ERS-2 |
| Measurement Principle | AC-based impedance spectroscopy (12.5 Hz sinusoidal current) |
| Electrode Type | Dual Ag/AgCl miniaturized probe electrodes |
| Probe Tip Diameter | ≤1.0 mm |
| Voltage Range | ±100 mV |
| Resistance Range | 0–10,000 Ω |
| Resolution | 1 Ω (0–1,000 Ω), 10 Ω (1,000–10,000 Ω) |
| Accuracy | ±2% of reading |
| Power Supply | 9 V alkaline battery (included) |
| Compliance | Designed for GLP-compliant TEER monitoring in vitro |
| Brand | POWCLIN |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | MSFLO |
| Pricing | Upon Request |
| Technology Platform | Mass Cytometry (ICP-TOF) |
| Instrument Type | Flow Cytometer for Single-Cell Metal Isotope Detection |
| Primary Use Case | Academic & Translational Research |
| Brand | Narishige |
|---|---|
| Origin | Japan |
| Model | IM-300 |
| Input Pressure Range | 60–100 psi (0.4–0.7 MPa) |
| Injection Pressure Range | 0.1–60 psi (0.7 kPa–0.4 MPa) |
| Balance Pressure Range | 0–10 psi (0–0.07 MPa) |
| Time Resolution | 10 ms–327.66 s |
| Step Count Range | 1–255 |
| Programmable Sequences | 10 × 100 steps |
| TTL Output | 8-bit |
| Power Supply | AC 100–120 V / 220–240 V, 50/60 Hz |
| Power Consumption | ~25 W |
| Dimensions | 425 × 205 × 90 mm |
| Weight | 3.7 kg |
| Brand | NARISHIGE |
|---|---|
| Origin | Japan |
| Model | XenWorks |
| Type | Motorized Micromanipulator and Digital/Analog Microinjector System for Intracellular and Embryonic Applications |
| Power Supply | 110–230 V AC, 50/60 Hz |
| Compliance | Designed for research use only |
| Brand | NIKON |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Patch-Clamp Electrophysiology System |
| Pricing | Available Upon Request |
| Brand | Sartorius |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | iQue® 3 |
| Product Type | High-Throughput Flow Cytometer |
| Application | Research Use Only |
| Brand | Sartorius |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | iQue® 5 |
| Technology Platform | Imaging Flow Cytometry |
| Product Type | Flow Cytometry Analyzer |
| Throughput | 96-well plate in ≤5 min, 384-well plate in ≤20 min |
| Detection Channels | 27 independent parameters with per-channel voltage control |
| Sample Compatibility | Cells, microspheres, yeast, and submicron particles down to 0.2 µm |
| Plate Formats | 96-well and 384-well plates |
| Automation Interface | Compatible with robotic liquid handlers |
| Fluidics Architecture | Patented air-gap sampling with swappable needles/tubing |
| Software Platform | iQue® ForeCyt® v6.x (with audit trail, analysis automation, and GLP-compliant reporting) |
| Optional Accessory | iQue® Qmax mobile fluid management cart |
| Brand | Sony |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Sony CGX10 |
| Pricing | Upon Request |
| Technology Pathway | High-Throughput Sorting Flow Cytometer |
| Product Type | Flow Cytometric Cell Sorter |
| Intended Use | Clinical & GMP-Compliant Cell Therapy Manufacturing |
| Lasers | 4 lasers (405 nm, 488 nm, 561 nm, 638 nm) |
| Detection Channels | 8-color fluorescence + FSC/SSC |
| Coefficient of Variation (CV) | ≤ 3% |
| Cell Analysis Rate | ≥ 100,000 cells/s |
| Sample Flow Rate | 20–60 µL/min |
| Compensation Modes | Automated, Manual, or Offline Compensation |
| Sorting Configuration | Fully enclosed bag-based collection system |
| Cell Sorting Rate | ≥ 33,000 cells/s |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Attune CytPix |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China-manufactured) |
| Model | Attune NxT Flow Cytometer |
| Pricing | Available upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | A59358 |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestically Produced Instrument |
| Model | Attune™ NxT Acoustic Focusing Flow Cytometer (Domestically Manufactured) |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (PRC-manufactured) |
| Model | Invitrogen Bigfoot Full-Spectrum High-Speed Flow Cytometer |
| Pricing | Available Upon Request |
| Brand | Invitrogen |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported Instrument |
| Model | Attune NxT |
| Product Category | Flow Cytometry Analyzer |
| Application Domain | Research-Grade Cell Analysis |
| Laser Configuration | Up to 4 Lasers, 16 Parameters |
| Coefficient of Variation (CV) | <3% |
| Sample Flow Rate | 12.5–1000 µL/min |
| Maximum Acquisition Speed | 65,000 events/sec |
| Fluorescence Sensitivity | ≤30 MESF (Molecules of Equivalent Soluble Fluorochrome) |
| Brand | Invitrogen |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Bigfoot |
| Product Category | Flow Cytometer for Cell Analysis |
| Application Domain | Research |
| Laser Configuration | Up to 9 Lasers, 60 Parameters |
| Optical Detection Channel Resolution | <0.2 µm |
| Sample Flow Rate | Up to 200 µL/min |
| Cell Throughput | >100,000 cells/sec |
| Fluorescence Sensitivity | <100 MESF (Molecules of Equivalent Soluble Fluorochrome) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | CTS Rotea Counter-Flow Centrifugation System |
| Pricing | Available Upon Request |
| Brand | Invitrogen |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Attune CytPix |
| Product Category | Imaging Flow Cytometer |
| Application Domain | Research |
| Laser Configuration | 4 Lasers (16 Detection Channels) |
| Optical Resolution (Spatial) | 0.2 µm |
| Sample Flow Rate | 100–1000 µL/min |
| Imaging Throughput | 6,000 images/sec |
| Cell Analysis Speed | ≤65,000 events/sec |
| Fluorescence Sensitivity | FITC < 80 MESF |
| Acoustic Focusing | Yes |
| Absolute Cell Counting | Integrated |
| Clog-Resistant Fluidics | Patented |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Tissue-3 |
| Price Range | USD 42,000 – 70,000 |
| Product Type | Microphysiological System (MPS) / Organ-on-a-Chip Platform |
| Laser Source | None (Optical Imaging–Based, Non-Flow Cytometric) |
| Detection Channels | 1 (Integrated Brightfield/Fluorescence Imaging Channel) |
| Spatial Resolution | ≤5 µm (at 20× objective) |
| Fluorescence Sensitivity | ≥10⁴ molecules per cell (FITC-equivalent) |
| Real-Time Imaging Frame Rate | Up to 30 fps (full-field, 1024 × 768) |
| On-Chip Perfusion Flow Rate | 0.1–100 µL/min, Pulsatile or Steady-State |
| Chip Format | Standard Microscope Slide Dimensions (75 × 25 × 1.0 mm) |
| Cell Culture Duration Support | ≥28 days under continuous perfusion |
| Brand | URIT |
|---|---|
| Origin | Guangxi, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (PRC) |
| Model | BF-710 |
| Pricing | Upon Request |
| Brand | URIT |
|---|---|
| Origin | Guangxi, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (PRC) |
| Model | BF-730 |
| Price Range | USD 14,000 – 140,000 |
| Technology Platform | Analytical Flow Cytometry |
| Instrument Type | Benchtop Flow Cytometer |
| Primary Use Case | Life Science Research & Clinical Assay Development |
| Lasers | Up to 3 solid-state lasers — 405 nm (≥85 mW), 488 nm (≥50 mW), 638 nm (≥60 mW) |
| Optical Detection Channels | 14 fluorescence parameters + 1 FSC channel + 1 SSC channel |
| Coefficient of Variation (CV) | ≤2% (at peak resolution, using standard calibration beads) |
| Fluorescence Sensitivity | FITC ≤25 MESF, PE ≤15 MESF |
| Maximum Event Acquisition Rate | 65,000 events/second |
| Sample Introduction | Integrated automated autosampler with continuous flow rate control (5–120 µL/s) |
| Compensation Modes | Real-time automated compensation, manual on-instrument compensation, and offline compensation via analysis software |