| Brand | HORDE Electric |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | HD-DP601 |
| Unit Price | USD 1,200 (FOB) |
| Liquid Velocity Measurement Resolution | 0.001 mm/s |
| Liquid Level Range | 0–10 m |
| Flow Velocity Range | 0–5 m/s |
| Instantaneous Flow Rate Range | 0–999,999,999 m³/h |
| Cumulative Flow Range | 0–999,999,999 m³ |
| Temperature Range | −10 to +70 °C |
| Level Resolution | 0.001 m |
| Flow Rate Resolution | 0.1 m³/h |
| Temperature Resolution | 0.1 °C |
| Housing Material | PVC |
| Power Consumption | <2 W |
| Display | TFT Color LCD |
| Enclosure Rating | IP65 (Transmitter), IP68 (Sensor) |
| Supply Voltage | Transmitter: AC 220 V / DC 24 V / Solar-Charged Battery |
| Sensor | 9–24 V DC |
| Output Signals | RS-485 Modbus RTU (standard), 4–20 mA analog output (standard), optional HART / NB-IoT / LoRaWAN |
| Data Update Interval | 8 s (default) |
| Mounting | Wall-mounted transmitter, immersion-type sensor with adjustable bracket |
| Cable Length | 10 m standard (custom lengths available) |
| Cable Material | Polyurethane-coated corrosion-resistant cable |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | GHD-1000 |
| Pricing | Available Upon Request |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GHD-3000 |
| Pricing | Available Upon Request |
| Brand | HUANKONG |
|---|---|
| Model | GHK-6010 |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Compliance | JJG711-1990, HJ15-2019, HJ353-2019, HJ354-2019, HJ355-2019 |
| Measurement Principle | Ultrasonic Time-of-Flight (TOF) |
| Display | 7-inch Color TFT Touchscreen |
| ADC Resolution | 24-bit |
| Data Storage Capacity | 50,000 Records |
| Battery Life | Up to 72 Hours (Li-ion Rechargeable) |
| Connectivity | USB 2.0, RS232, Optional GNSS (GPS/BeiDou) |
| Printing | Integrated Thermal Microprinter |
| Portability | Carry-on Case Design, <3.2 kg Total Weight |
| 堰 Compatibility | V-notch, Rectangular, Parshall, and Trapezoidal (UST) Weirs |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | GHK-6010 |
| Liquid Mass Flow Accuracy | ±0.1% FS |
| Signal Acquisition Resolution | 24-bit |
| Data Storage Capacity | 50,000 records |
| Battery Life | Up to 72 hours (fully charged) |
| Display | Color TFT LCD with capacitive touch interface |
| Connectivity | USB port for data export and printer interface |
| Optional | GNSS positioning (GPS/BeiDou) |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Regional Category | Domestic (China) |
| Model | GHK-7000 |
| Pricing | Upon Request |
| Flow Measurement Principle | Differential Pressure |
| Key Components | Orifice Module, Soap Film Module, Thermal Mass Flow Module, Microcontroller Unit, TFT Touch Display |
| Calibration Standards | JJG 586–2006, JJG 700–2016, JJF 2033–2023 |
| Operating Modes | Real-time flow display (actual, STP @ 273.15 K / 101.325 kPa, NTP @ 293.15 K / 101.325 kPa, RTP @ 298.15 K / 101.325 kPa) |
| Data Storage | 80 entries per range |
| Power Supply | Rechargeable Li-ion battery (>8 h runtime) |
| Interface | USB port (U-disk export supported), Optional Bluetooth thermal printer |
| Environmental Input | Manual barometric pressure & ambient temperature entry |
| Sensor Calibration | Digital calibration for flow, differential pressure, temperature, time, and battery voltage |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | GHK-7000Z |
| Flow Principle | Soap Film Method |
| Display | 4.3-inch Color Touchscreen |
| Time Resolution | 0.001 s |
| Operating Modes | Ambient / STP (273.15 K, 101.325 kPa) / NTP (293.15 K, 101.325 kPa) |
| Environmental Correction | Integrated Temperature & Pressure Compensation |
| Data Interface | USB Type-B, Optional Bluetooth Thermal Printer |
| Power Supply | AC Adapter (100–240 VAC) + Rechargeable Li-ion Battery (≥8 h runtime) |
| Compliance | JJG 586–2006 Verification Regulation for Soap Film Flowmeters |
| Construction | Modular Detector Cartridge Design |
| Sensor Technology | Infrared Photogate Array with Microcontroller-Based Timing Engine |
| Light Shielding | Opaque Acrylic Tube Housing |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | GHK-7000Z |
| Flow Principle | Soap film displacement method |
| Measurement Range | Multi-range configurable (low / medium / high flow modes) |
| Display | Color touchscreen interface |
| Time Resolution | 0.001 s |
| Environmental Compensation | Temperature, pressure, and volumetric correction algorithms |
| Data Output | USB port, optional USB flash drive export, Bluetooth printer support |
| Power Supply | AC/DC dual-mode with built-in rechargeable Li-ion battery (≥8 h operation) |
| Compliance | JJG 586–2006 “Verification Regulation for Soap Film Flowmeters” |
| Application Scope | Calibration of air samplers, dust samplers, microbial samplers, flue gas samplers, and GC carrier gas flow systems |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | GHK-7100 |
| Price | USD 1,150 (FOB) |
| Flow Measurement Principle | Differential Pressure (Soap Film Method) |
| Display | Large LCD with Chinese/English bilingual interface |
| Time Resolution | 0.001 s |
| Power Supply | AC/DC dual-mode |
| Operating Conditions Compensation | Automatic temperature (°C), pressure (kPa), and volume correction for standard conditions at 273.15 K / 101.325 kPa and 293.15 K / 101.325 kPa |
| Data Output | Optional thermal mini-printer support |
| Compliance | JJG 586–2006 Verification Regulation for Soap Film Flowmeters |
| Electromagnetic Compatibility | IEC 61326-1 compliant design |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | GHK-7201 |
| Pricing | Upon Request |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | GHK-7202 |
| Product Category | Differential Pressure-Based Calibrator |
| Calibration Standards | JJG586–2006, HJ/T368–2007, JJG633–2005, JJF2033–2023 |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | GHK-7203 |
| Price | Upon Request |
| Flow Range | 5–100 L/min |
| Display | Backlit LCD with Chinese UI |
| Data Storage | 100 records (flow, volume, pressure, temperature, resistance) |
| Environmental Compensation | Automatic ambient temperature & atmospheric pressure measurement |
| Reference Conditions | Standard (273.15 K, 101.325 kPa), Reference (298.15 K, 101.325 kPa), Actual (in-situ) |
| Power Supply | Rechargeable Li-ion battery, ≥8 h continuous operation |
| Connectivity | USB port for data export to USB flash drive |
| Output | Thermal printer support (optional) |
| Compliance Standards | HJ 955–2018, JJG 680–2021, JJG 520–2005 |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | GHK-7204 |
| Pricing | Available Upon Request |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | GHK-7301 |
| Pricing | Upon Request |
| Compliance | JJG 586–2006 “Verification Regulation for Soap Film Flowmeters” |
| Display | High-contrast LCD with intuitive GUI |
| Sensing Method | Infrared optical detection |
| Time Resolution | 0.001 s |
| Environmental Compensation | Real-time T & P measurement (ambient temperature, atmospheric pressure, gas path temperature & pressure) |
| Output Interfaces | TTL timing pulse port, RS232 serial interface |
| Correction Capabilities | Temperature, pressure, and volumetric calibration factor adjustment |
| Tube Configurability | Modular soap film tube assembly for multi-range operation |
| EMC Design | IEC 61326-compliant electromagnetic compatibility architecture |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | GHK-7302 |
| Product Category | Differential Pressure Type |
| Compliance | JJG 586–2006 Verification Regulation for Soap Film Flowmeters |
| Measurement Principle | Volumetric Displacement via Soap Film Transit Time |
| Display | 7-inch Color Touchscreen |
| Time Resolution | 0.001 s |
| Data Storage Capacity | 10,000 Records |
| Communication | Wireless (Host–Detector Separation) |
| Sensor Type | Infrared Photogate Array |
| Calibration Output | Actual Flow (Q_act), Standard Flow at 0 °C/101.325 kPa (Q_std_0C), Standard Flow at 20 °C/101.325 kPa (Q_std_20C), N-cycle Average |
| Environmental Correction | Digital Temperature, Pressure, and Volume Compensation |
| Automation Features | Auto-film generation, auto-wetting, auto-measurement, real-time display of flow states |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | GHK-7400 |
| Price | USD 14,000 (FOB) |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | GHK-7500 |
| Pricing | Upon Request |
| Brand | ISCO |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ISCO 2150 |
| Price | Upon Request |
| Measurement Principle | Continuous-Wave Doppler Ultrasonics + Velocity-Area Method |
| Minimum Measurable Depth | 25 mm |
| Enclosure Rating | NEMA 4X/6P, IP68 |
| Operating Temperature | −40 °C to +60 °C |
| Power Supply | 12 VDC (7.0–16.6 VDC) |
| Typical Operating Current | 100 mA |
| Standby Current | 1 mA |
| Dimensions (H×W×D) | 7.4 cm × 28.7 cm × 19.1 cm |
| Weight | 0.9 kg |
| Housing Material | Impact-resistant polystyrene & stainless steel |
| Battery Life (15-min logging) | 15 months (Energizer® 529 alkaline) |
| Data Storage | Non-volatile flash memory |
| Communication | RS-232, 38,400 bps |
| Probe Calibration | Factory-calibrated at 120 points across 3 m depth range and multiple temperatures |
| Pressure Compensation | Integrated vented piezoresistive sensor |
| Probe Sealing | Epoxy-potted transducer with hydrophobic membrane & desiccant tube |
| Brand | ISCO |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LaserFlow |
| Pricing | Upon Request |
| Brand | Junray |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | ZR-5031 |
| Product Category | Volumetric Flow Calibrator |
| Applicable Standards | JJF 1826–2020, JJG (Hebei) 164–2019, GB/T 16293–2010 |
| Brand | Junray |
|---|---|
| Model | ZR-5041 |
| Type | Portable Orifice-Based Flow Calibration Instrument |
| Measurement Principle | Critical-Flow Orifice (CFO) / Differential Pressure Method |
| Display | 5-inch HD Touchscreen |
| Power | Rechargeable Lithium Battery (>8 h runtime) |
| Operating Ambient Temperature | −20 °C to +40 °C |
| Flow Accuracy & Repeatability | Engineered for high reproducibility per HJ/T 368–2007 and JJG 640–2016 |
| Temperature Sensing | Integrated PT100-compatible circuitry, ±1 °C max permissible error |
| Pressure Sensing | Built-in high-precision differential pressure sensor |
| Data Output | Bluetooth-enabled thermal printing |
| Flow Modes | Real-time actual (working condition), standard (STP: 273.15 K, 101.325 kPa), and scale flow display |
| Averaging Function | Time-weighted mean calculation up to 9999 seconds |
| Compliance | HJ/T 368–2007, HJ 644–2013, HJ 93–2013, HJ 1263–2022, HJ 955–2018, JJG 640–2016, JJG 680–2021, JJG 956–2013, JJG 1169–2019 |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | CTA/HWA 7000 |
| Sensor Type | Thermal (Constant-Temperature Anemometry) |
| Bridge Ratio Options | 1:1 (max. 500 mA) or 5:1 (max. 1.2 A) |
| Probe Current Limit | 500 mA (1:1 configuration) |
| Frequency Response | Up to 140 kHz (with 5 µm tungsten wire probe) |
| Power Supply | AC 100/115 V ±10%, 50/60 Hz |
| Enclosure Dimensions | 436 × 149 × 456 mm |
| Compliance | Designed for ISO/IEC 17025-aligned laboratory environments and ASTM D5467-compliant airflow characterization |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | BubbleMaster |
| Sensor Type | Optical Fiber (Wedge-Tip, F-Top Configuration) |
| Measurement Principle | Optical Intensity Modulation at Bubble-Transit Interface |
| Output | Individual Bubble Diameter & Transit Velocity |
| Fluid Compatibility | Electrically Insulating Liquids |
| Compliance | Designed for Research-Grade Bubble Characterization in Nuclear and Chemical Engineering Environments |
| Price Range | USD 13,500 – 40,500 (FOB Japan) |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | IHW-100 |
| Sensor Type | Thermal (Constant-Temperature Anemometry) |
| Measurement Principle | CTA (Constant-Temperature Anemometry) |
| Bridge Ratio | 10:1 |
| Maximum Probe Current | 500 mA |
| Frequency Response | 10 kHz (with 5 µm tungsten wire probe) |
| Power Supply | AC 100/115 V ±10%, 50/60 Hz |
| Dimensions (H×W×D) | 99 × 430 × 300 mm |
| Probe Compatibility | Interchangeable hot-wire and hot-film probes |
| Compliance | Designed for laboratory-grade fluid dynamics research per ISO 80000-4, ASTM D5096, and IEC 60068-2 environmental test standards |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | LDV (1D-FLV, 2D-FLV, Smart LDV) |
| Laser Source | He–Ne (10 mW) / Ar-ion |
| Frequency Shift | Dual Bragg Cell |
| Shift Frequencies | 0–5 MHz (1–2–5 steps) |
| Photodetection | Photomultiplier Tube (PMT) |
| Optical Configuration | Forward-scatter (1D/2D), Focal Length: 170 mm (Smart LDV) |
| Dimensions (1D-FLV) | 430 × 200 × 600 mm |
| Weight | Approx. 20 kg |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | Smart LDV II |
| Velocity Range | –40 to +100 m/s |
| Laser Source | Laser Diode, λ = 660 nm, 60 mW |
| Focal Distances | 150 / 200 / 250 / 300 / 350 / 400 mm |
| Focal Spot Size | 0.13 mm × 0.13 mm |
| Probe Dimensions | 61 mm (dia.) × 312 mm (length) |
| Doppler Shift Frequency Range | 0.01–10 MHz |
| Probe Weight | 2.5 kg |
| Signal Processor (Model 8008) | 8-bit FFT, 1 kHz–40 MHz bandwidth, 16,000 data points/sec, full-size PCI board |
| Traverse System | 3-axis, max vertical load 7 kg, translation speed 80 mm/sec, positioning accuracy ±0.025 mm |
| Interface | RS232C, BNC I/O, interlock connector |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | SmartLDV III |
| Laser Wavelength | 660 nm |
| Laser Power | 60 mW |
| Velocity Range | –40 to +264 m/s (at 400 mm focal distance, model 8743-S) |
| Focal Distances | 150, 200, 250, 300, 350, 400 mm |
| Spot Size | 0.13 mm × 1.3 mm (f = 200 mm) |
| Probe Dimensions | Ø61 mm × 345 mm |
| Probe Weight | 3.5 kg |
| Frequency Shift Range | 0.01–10 MHz |
| Signal Processor | KANOMAX Model 8008 |
| FFT Resolution | 8-bit |
| Frequency Bandwidth | 1 kHz – 40 MHz |
| Input Signal Range | 20 mV – 1 V (Doppler signal) |
| Data Acquisition Rate | 16,000 samples/sec |
| 3-Axis Traverse Stage | Max. vertical load 7 kg |
| Traverse Speed | 80 mm/sec |
| Positioning Accuracy | ±0.025 mm |
| Interface | RS232C |
| Compliance | CE-marked |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 8745-S |
| Laser Wavelength | 660 nm |
| Laser Power | 60 mW |
| Velocity Range | –40 to +264 m/s (at 400 mm focal distance, model 8745-S) |
| Focal Distances | 150, 200, 250, 300, 350, 400 mm |
| Spot Size | 0.13 mm × 1.3 mm (f = 200 mm) |
| Probe Dimensions | Ø61 mm × 345 mm |
| Probe Weight | 3.5 kg |
| Frequency Shift Range | 0.01–10 MHz |
| Signal Processor | SmartLDV Model 8008 |
| FFT Resolution | 8-bit |
| Frequency Bandwidth | 1 kHz – 40 MHz |
| Input Signal Range | 20 mV – 1 V |
| Data Acquisition Rate | 16,000 samples/sec |
| 3-Axis Traverse System | Max. vertical load 7 kg, travel speed 80 mm/sec, positioning accuracy ±0.025 mm |
| Interface | RS232C |
| Compliance | CE-marked, RoHS-compliant, designed for ISO/IEC 17025-aligned laboratory environments |
| Brand | KEYENCE |
|---|---|
| Origin | Japan |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | FD-Q |
| Pricing | Upon Request |
| Liquid Mass Flow Accuracy | ±0.15% |
| Brand | KEYENCE |
|---|---|
| Origin | Japan |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | FD-X |
| Pricing | Upon Request |