Flue Gas Analyzer
Filter
Showing 121–150 of 245 results
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | PG-350 |
| Instrument Type | Portable Flue Gas Analyzer |
| Accuracy | ±2.0% FS |
| Repeatability | ±1.0% FS |
| Response Time (T90) | ≤45 s for NOₓ, CO, CO₂, O₂ |
| Drift | ±1.0% FS/day (SO₂: ±2.0% FS/day) |
| Warm-up Time | 30 min |
| Sample Flow Rate | ~0.5 L/min |
| Display | Color TFT LCD with Touch Interface |
| Data Storage | Removable SD Card |
| Output | 4–20 mA DC analog output, Ethernet interface |
| Power Supply | 100–120 VAC / 200–240 VAC, 50/60 Hz |
| Dimensions | 226 × 265 × 510 mm (W × H × D) |
| Weight | ~14 kg |
| Operating Environment | 5–40 °C, ≤85% RH |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | VA-3000 / VS-3000 |
| Repeatability | ±0.5% FS |
| Response Time (T90) | ≤30 s |
| Stability | ±2.0% FS/week |
| Detection Principles | NDIR, CLA, MPA, Electrochemical (Galvanic), Zirconia |
| Gas Compatibility | CO, CO₂, NOₓ, SO₂, CH₄, N₂O, C₂H₄, O₂ |
| Max Integrated Sensor Modules | 3 |
| Analog Outputs | DC 0–1 V / 4–20 mA (optional) |
| Communication Interface | RS-232C |
| Operating Temperature | 0–40 °C |
| Power Supply | AC 100–120 V or 200–240 V, 50/60 Hz |
| Weight (VA-3000) | ~20 kg |
| Enclosure | 19-inch rack-mount chassis |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | VA-3000/VS-3000 |
| Repeatability | ±0.5% of Full Scale |
| Response Time | T90 ≤ 30 s |
| Stability | ±2.0% of Full Scale per Week |
| Detection Principles | NDIR, CLA, MPA, Electrochemical (Galvanic), Zirconia |
| Gas Compatibility | CO, CO₂, NOₓ, SO₂, CH₄, N₂O, C₂H₄, O₂ |
| Max Internal Sensor Modules | 3 |
| Analog Outputs | DC 0–1 V / 4–20 mA (optional) |
| Communication Interface | RS-232C |
| Operating Temperature | 0–40 °C |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Weight (VA-3000) | ~20 kg |
| Enclosure | 19-inch rack-mountable chassis |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | VA-3000 (Analyzer Unit) / VS-3000 (Sampling System) |
| Repeatability | ±0.5% of Full Scale |
| Response Time | T90 ≤ 30 s |
| Stability | ±2.0% of Full Scale per Week |
| Detection Principles | NDIR, CLA, MPA, Electrochemical (Galvanic), Zirconia |
| Gas Compatibility | CO, CO₂, NOₓ, SO₂, CH₄, N₂O, O₂, C₂H₄ (optional), Cl₂ (optional) |
| Analog Outputs | DC 0–1 V / 4–20 mA (optional) |
| Digital Interface | RS-232C |
| Operating Temperature | 0–40 °C |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Analyzer Dimensions | 430 × 132 × 550 mm (W×H×D) |
| Weight | ~20 kg |
| Sampling Unit Dimensions (VS-3004) | 430 × 221 × 550 mm |
| Weight | ~20 kg |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | VA-3000 (Analyzer Unit) / VS-3000 (Sampling System) |
| Detection Principle | Non-Dispersive Infrared (NDIR), Chemiluminescence (CLA), Magnetic Pressure (MPA), Electrochemical (Galvanic), Zirconia |
| Repeatability | ±0.5% FS |
| Response Time (T90) | ≤30 s |
| Drift | ±2.0% FS/week (NDIR/CLA/MPA/ZrO₂), ±1.0% FS/day (Galvanic O₂) |
| Linearity | ±1.0% FS (≤10× range), ±1.5% FS (>10× range) |
| Warm-up Time | 20–60 min (varies by sensor type) |
| Analog Outputs | DC 0–1 V, 4–20 mA (optional) |
| Digital Interface | RS-232C |
| Sample Flow Rate | 0.5 L/min (analyzer inlet) |
| Operating Environment | 0–40 °C, RH ≤90% non-condensing |
| Power Supply | AC 100–120 V or 200–240 V, 50/60 Hz |
| Dimensions (VA-3000) | 430 × 132 × 550 mm (W×H×D) |
| Weight (VA-3000) | ~20 kg |
| Compliance | Designed for ISO 14001-aligned monitoring, compatible with EPA Method 6C/7E/10, EN 15267-certified system architecture (sensor modules), supports GLP/GMP data integrity via timestamped analog/digital output logging |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurement Accuracy | ≤ ±5% FS |
| Repeatability | ≤ ±5 ppm |
| Response Time | ≤ 60 s |
| Drift Stability | ≤ ±5% over 24 h |
| Measured Gases | O₂, CO, NO, NO₂, SO₂, CO₂, H₂, NOₓ (as NO₂), flue gas temperature, ambient temperature, static/velocity pressure, dew point, excess air ratio, combustion efficiency, heat loss, fuel moisture |
| Display | 7-inch full-color TFT LCD touchscreen |
| Data Storage Capacity | 300,000 records |
| Gas Filtering | 4-stage particulate filtration (≥1 µm) |
| Optional Sensors | Low-range, high-precision electrochemical and NDIR modules compliant with updated Chinese emission standards |
| Brand | HUANKONG |
|---|---|
| Model | GHK-2010 |
| Type | Portable Flue Gas Analyzer |
| Measurement Principle | Pitot Tube Method |
| Compliance | JJG 518–1998, GB/T 16157–1996 |
| Power Supply | Rechargeable Li-ion Battery (≥48 h operation) |
| Data Storage | 800 measurement sets |
| Display | High-brightness wide-temperature color LCD |
| Connectivity | Built-in Bluetooth v4.2 |
| Pressure Sensors | High-accuracy differential pressure transducers (±0.5 Pa resolution) |
| Parameters Measured | Flue gas velocity, volumetric flow rate, dry standard flow rate, dynamic pressure, static pressure, flue gas temperature |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Portable Flue Gas Analyzer |
| Measured Parameter | Flue Gas Moisture (Relative Humidity & Dew Point) |
| Measurement Principle | Capacitive Hygrometry with Temperature/Pressure Compensation |
| Compliance Standard | GB/T 11605–2005 |
| Sensor | Imported Capacitive Humidity Sensor with Integrated Heating Element and Dual-Layer Dust Filtration |
| Operating Temperature Range | –20 °C to +180 °C (probe), –10 °C to +50 °C (main unit) |
| Data Storage Capacity | 10,000 measurement records |
| Display | Wide-Temperature High-Brightness LCD |
| Power | Removable High-Capacity Rechargeable Battery |
| Optional Accessory | Thermal Printer Module |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | GHK-2020B |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurement Accuracy (Humidity) | < ±1% FS |
| Repeatability | < 2% |
| Response Time | < 30 s |
| Measured Parameters | Relative Humidity (%RH), Flue Gas Velocity (m/s), Static/Total Pressure (kPa), Temperature (°C), and Operating Condition Parameters (e.g., stack diameter, sampling point depth, isokinetic ratio) |
| Brand | HUANKONG |
|---|---|
| Model | GHK-2100D |
| Type | Portable Flue Gas & Particulate Analyzer |
| Origin | Shandong, China |
| Manufacturer | HUANKONG (Domestic Producer) |
| Compliance | GB/T 16157–1996, HJ/T 48–1999, HJ 57–2017, HJ 693–2014, HJ 836–2017, JJG 680–2007, JJG 968–2002 |
| Sampling Principle | Pitot Tube Parallel Isokinetic Sampling + Gravimetric Filtration (for PM) + Potentiostatic Electrolysis (for SO₂/NOₓ) |
| Display | High-brightness wide-temperature color touchscreen with dual touch/key input |
| Flow Range | 0–110 L/min (max), isokinetic tracking up to 40 L/min |
| Power Input | AC 80–260 V (with overvoltage/overcurrent protection) |
| Housing Material | Titanium alloy (high-temp resistant, corrosion-resistant, low adsorption, lightweight) |
| Data Storage | ≥100,000 records |
| Connectivity | Wired & wireless (sampling tube), Bluetooth printer support |
| Certifications | Compliant with Chinese national metrological verification regulations and environmental monitoring technical specifications |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Portable Flue Gas Analyzer |
| Model | GHK-2400 |
| Measurement Principle | UV DOAS (Differential Optical Absorption Spectroscopy) |
| Measured Gases | SO₂, NO, NO₂, O₂, CO, CO₂ |
| Measurement Uncertainty | ≤ ±5.0% FS |
| Repeatability | ≤ 2.0% RSD |
| Response Time (T₉₀) | ≤ 90 s |
| Zero Drift & Span Drift (24 h) | ≤ 5.0% FS |
| Water Vapor Interference | Negligible (DOAS-based water vapor correction embedded) |
| Regulatory Compliance | GB/T 37186–2018, HJ 1131–2020, HJ 1132–2020, HJ 1045–2019, JJG 968–2002, DB37/T 2704–2015, DB37/T 2705–2015, DB37/T 2641–2015, HJ/T 397–2007, GB 13233–2011 |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | GHK-2400S |
| Instrument Type | Portable Flue Gas Analyzer |
| Response Time | ≤90 s |
| Measurable Gases | SO₂, NO, NO₂, NH₃, CO, CO₂, O₂ |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | HY-3000 |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Measurement Repeatability | <1% |
| Response Time | 30 s |
| Measured Gases | CO, CO₂, CH₄, O₂ |
| Brand | IMR |
|---|---|
| Origin | USA |
| Model | 2800P |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurement Accuracy | ±2% FS |
| Response Time | <90 s |
| Drift Stability | <5% over 1 h |
| Measured Parameters | O₂, NO, NO₂, CO, SO₂, HC/CH₄, Flue Gas Temperature (TG), Ambient Temperature (TA) |
| Sensor Technology | Electrochemical (O₂, NO, NO₂, CO, SO₂, HC/CH₄) |
| Operating Temperature Range (Probe) | Up to 1200 °C (1600 °C optional) |
| Battery Life | 6 h (rechargeable Li-ion) |
| Compliance | Certified for official emission monitoring per German TA Luft and EU Directive 2010/75/EU (IED), supports ASTM D6522, EN 15267-3, and VDI 3862 |
| Data Output | RS232, USB |
| Display | Backlit LCD showing up to 8 parameters simultaneously |
| Built-in Printer | Yes (programmable, on-site thermal printout) |
| Fuel Database | 23 preloaded fuel types + 4 user-definable |
| Calculated Parameters | λ (excess air ratio), qA (dry flue gas loss), CO₂ (by ASME PTC 4.1 equation), NOₓ (as NO₂-equivalent) |
| Brand | IMR |
|---|---|
| Origin | USA |
| Model | IMR1400C |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurement Accuracy | <2% FS |
| Repeatability | <2% FS |
| Response Time | 1 s |
| Stability | <2% FS over 8 h |
| Measurable Gases | O₂, NO, NO₂, CO, SO₂, HC/CH₄ |
| Optional Sensors | HCl, N₂O, Cl₂, H₂, NH₃, H₂S, CO₂ (IR) |
| Operating Temperature Range | –20 °C to +1200 °C (flue gas), –20 °C to +120 °C (ambient) |
| Dimensions | 305 × 228.6 × 117 mm |
| Weight | 2.9 kg |
| Battery Life | Up to 6 h (rechargeable Li-ion) |
| Communication Interfaces | RS232, USB |
| Compliance | Certified for official emissions monitoring per German TA-Luft and EU EN 15267-3 |
| Brand | IMR |
|---|---|
| Origin | USA |
| Model | IMR5000 |
| Instrument Type | Flue Gas CEMS |
| Measurement Accuracy | <2% FS |
| Repeatability | <2% FS |
| Stability | <2% FS |
| Response Time | Real-time |
| Measured Parameters | O₂, NO, NO₂, CO, SO₂, HC, CH₄, H₂S, HCl, NH₃, N₂O, O₃, PM |
| Sensor Technologies | Electrochemical (O₂, NO, NO₂, CO, SO₂, H₂S, NH₃, HCl, N₂O, O₃), NDIR (CH₄, CO₂*), Catalytic Bead (HC), Optional Paramagnetic (O₂), Thermal Conductivity (H₂), Optical Scattering (PM) |
| Brand | IMR |
|---|---|
| Origin | USA |
| Model | IMREX660 |
| Instrument Type | Portable Flue Gas Analyzer |
| Accuracy | <2% FS |
| Repeatability | <2% FS |
| Response Time (T90) | <30 s |
| Stability | <2% FS over 8 h |
| Operating Temperature | –20°C to +50°C (toxic gases) |
| Operating Humidity | <95% RH, non-condensing |
| Weight | 500 g |
| Dimensions | 168 × 91 × 45 mm |
| Data Storage Capacity | 100,000 records |
| Battery Life | Up to 30 h (rechargeable Li-ion) |
| Detection Methods | Electrochemical, Catalytic Bead, NDIR, PID, and Semiconductor Sensors |
| Gas Channels | Up to 6 simultaneous sensor modules (7 gas parameters concurrently) |
| Alarm Modes | Dual-stage audible (buzzer), visual (LED flash), and tactile (vibration) |
| Compliance | Certified per German TA-Luft emission guidelines |
| Brand | Junfang Lihua |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | GXH-1050D |
| Price Range | USD 1,400 – 7,000 |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Measurement Principle | Non-Dispersive Infrared (NDIR) |
| Accuracy | ≤ ±1% F.S. |
| Repeatability | ≤ ±1% F.S. |
| Response Time (T₀–T₉₀) | ≤ 15 s |
| Zero Drift | ≤ ±1% F.S. / 24 h |
| Span Drift | ≤ ±1% F.S. / 24 h |
| Linearity Error | ≤ ±1% F.S. |
| Detection Gases | CO, CO₂, CH₄, C₃H₈, H₂, O₂ |
| Minimum Range | 0–100 ppm |
| Maximum Range | 0–100% v/v |
| Flow Rate | 0.5–3 L/min |
| Operating Temperature | 0–40 °C |
| Relative Humidity | ≤ 90% RH (non-condensing) |
| Power Supply | 220 V ±10%, 50 Hz ±0.5 Hz, 150 W |
| Output Signals | 0–20 mA, 4–20 mA, 0–10 mV, 1–5 V (load ≤ 600 Ω, isolated) |
| Display | Digital concentration readout with dual-range capability (ppm and % v/v) |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM/ODM Producer |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurement Accuracy | ±5% FS |
| Repeatability | ±1% FS |
| Response Time | 90 s (T90) |
| Drift Stability | ±3% over 8 h |
| Measured Parameters | O₂, SO₂, NO, NO₂, CO, Flue Gas Temperature, Ambient Temperature, Draft Pressure (±500 Pa range) |
| Power Supply | Rechargeable Li-ion battery (6 h continuous operation) |
| Data Storage | Internal memory for ≥10,000 measurement records |
| Communication | Bluetooth 4.2 BLE, Infrared thermal printer interface |
| Calibration | Built-in zero/span auto-calibration routine with user-guided prompts |
| Display | Backlit 3.5" TFT LCD (320×240), Chinese/English bilingual UI |
| Gas Path | Dual-pump aspiration system with integrated particulate filter, hydrophobic membrane, and catalytic CO/SO₂ cross-interference compensation module |
| Compliance | Designed per GB/T 16157–1996, HJ/T 397–2007, and ISO 12039:2000 principles for stationary source emission monitoring |
| Brand | LAND |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Lancom 4 |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurement Accuracy (Full Scale) | ±2% |
| Repeatability | ±2% |
| Response Time (T90) | 60 s |
| Long-Term Stability (24 h) | ±2% |
| Measurable Gases | CO, O₂, NO, NO₂, CO₂, H₂S, SO₂, CₓHᵧ (up to 9 gases simultaneously) |
| Display | High-Resolution Color TFT Screen |
| Language Support | English, French, German, Italian, Spanish, Chinese (custom languages available on request) |
| Data Interface | USB 2.0 (PC connectivity & USB flash drive support) |
| Weight | 6 kg (13.2 lbs) |
| Compliance | ASTM D6522 (when used with integrated sample drying probe) |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | AOA 200CEMS |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Measurement Principle | Heated Extractive Sampling + Isokinetic Particulate Sampling + Energy-Dispersive X-Ray Fluorescence (ED-XRF) |
| Target Analytes | Pb, Cr, Cd, As, Hg, Ni, Zn, Cu, Mn, Sb (as particulate-bound species) |
| Sampling Interval | Programmable (default 15 min) |
| Data Output Interfaces | RS232/RS485, USB, GPRS, ADSL, Ethernet |
| Radiation Safety | Fully Shielded ED-XRF Module with <0.1 µSv/h external dose rate |
| QC Protocol | Internal Standard Element Monitoring for Drift Correction |
| Compliance Framework | Designed to support EPA Method 29 / ISO 14956 / HJ 657–2013 / HJ 93–2013 alignment |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | SootMaster |
| Instrument Type | Continuous Emission Monitoring System (CEMS) for Soot |
| Application Domain | In-situ, time-resolved soot volume fraction and primary particle size distribution imaging in combustion flows |
| Brand | LESHI |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Portable FTIR Flue Gas Analyzer |
| Price | USD 155,000 (approx.) |
| Measurement Accuracy | ≤ ±2% FS |
| Repeatability | ≤ 1% RSD |
| Response Time | 1 scan/sec (adjustable based on resolution) |
| Baseline Stability | ≤ ±2% over 24 h |
| Quantitative Capability | ≥51 gases (simultaneous) |
| Qualitative Capability | ≥380 compounds (library-matched) |
| Spectral Resolution | 0.7–8 cm⁻¹ (software-selectable, unapodized) |
| Operating Sample Temperature | Up to 180 °C (hot-wet sampling) |
| Particle Filtration | <2 µm (dual-stage heated filter) |
| Detector | Room-temperature DTGS |
| Reference Source | VCSEL laser (10-year lifetime) |
| O₂ Sensor | Integrated zirconia sensor |
| Data Output | Real-time spectral + concentration + metadata (T, P, O₂, resolution) |
| Compliance | HJ 919–2017, HJ 920–2017, HJ 1011–2018, HJ 1240–2021, HJ 1330–2023 |
| Software Standards Support | ASTM D6348, US EPA Method 320, ISO 14912, UK EA TGN 15 |
| Brand | LESHI |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | 9100HIR |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurement Accuracy | ≤ ±2% FS |
| Repeatability | ≤ 2% FS |
| Response Time | T90 |
| Baseline Stability | ≤ 2% FS over 24 h |
| Measured Gases | >50 Species (O₂, CO, CO₂, NO, NO₂, N₂O, SO₂, CH₄, NH₃, H₂O, HCl, CH₂O, C₃H₈, etc.) |
| Optical Path Length | Up to 16 m |
| Detection Principle | High-Temperature Non-Dispersive Infrared (NDIR) Spectroscopy with Multi-Range Auto-Switching |
| Brand | LESHI |
|---|---|
| Model | SE300-Tech |
| Type | Portable Flue Gas Analyzer |
| Detection Principle | NDIR (CO, CO₂, HC, SO₂), Electrochemical (O₂, NO, NO₂, NH₃, H₂S), Optional NDUV (NO, NO₂, SO₂) |
| Gas Channels | Up to 6 simultaneously measurable gases (standard configuration) |
| Compliance | Designed for field-deployable combustion efficiency and emissions verification per ISO 12039, EN 15267, and EPA Method 6C/7E prerequisites |
| Power | Rechargeable Li-ion battery (≥4 hr continuous operation) |
| Display | 5.7" TFT LCD with touch interface |
| Data Storage | Removable MMC card (up to 32 GB) |
| Connectivity | USB 2.0, Bluetooth 4.2, optional RS-232 |
| Operating Temperature | 0–40 °C |
| Protection Rating | IP42 |
| Weight | ≤2.8 kg |
| Brand | LESHI |
|---|---|
| Origin | Beijing, China |
| Model | SE305 |
| Type | Portable Flue Gas Analyzer |
| Detection Principles | Electrochemical (O₂, CO, NO, NO₂, SO₂) and Catalytic/Thermal Conversion (NO₂ → NO for NOx calculation) |
| Compliance | HJ 692–2014 (Determination of Nitrogen Oxides in Exhaust Gas from Stationary Sources — Potentiostatic Electrolysis Method) |
| Display | Backlit LCD with Single- or Multi-parameter View (O₂, CO, SO₂, NO, NO₂, NOₓ) |
| Sampling System | Integrated diaphragm pump, stainless-steel probe (with 12 ft PTFE-lined sampling hose), condenser, dual-stage particulate filter, mass flow meter, and onboard NO₂-to-NO converter |
| Optional Accessories | Continuous condensate drain module, external cooling/drying unit |
| Enclosure Rating | IP54 (dust-protected, splash-resistant) |
| Operating Temperature Range | 0–40 °C |
| Power Supply | Rechargeable Li-ion battery (≥6 h continuous operation) |
| Data Logging | Internal memory (≥10,000 records), USB export |
| Brand | M&C |
|---|---|
| Model | ECM-1 / ECM-2 / ECM-EX2-1 / ECM-EX2-2 |
| Origin | Germany |
| Cooling Principle | Compressor-based refrigerated drying with jet-type heat exchanger |
| Dew Point Range | Adjustable from +2 °C to +7 °C |
| Dew Point Accuracy | ±0.1 °C |
| Heat Exchanger Capacity | ECM-1/ECM-EX2-1: 1 × 250 Nl/h |
| ECM-2/ECM-EX2-2 | 2 × 150 Nl/h |
| Ambient Operating Temperature | Up to 50 °C |
| Certification | ATEX II 2G Ex db IIB T4 Gb, CSA C/US Class I Div 2, FM Class I Div 2, cCSAus |
| Condensate Removal | Peristaltic pump SR25.2 or automatic drain AD |
| Display | Front-panel digital temperature controller with real-time cooling temperature readout and alarm relay output (active at <2 °C or >8 °C) |
| Mounting | Compact rear-panel mounting |
| Housing Material Options | Standard heat exchanger tubes available in borosilicate glass, stainless steel (316L), or PVDF |
| Compliance | Designed for integration into EN 15267-, EPA PS-11-, and ISO 16911-compliant flue gas monitoring systems |
| Brand | Madur |
|---|---|
| Origin | Austria |
| Model | CMS-7 |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Accuracy | ±5% of reading |
| Repeatability | ≤2% |
| Response Time (T90) | 45 s |
| Stability | ≤5% drift over 1 h |
| Gas Detection Principle | NDIR (CO₂, CH₄, CO), Electrochemical (CO, NO, NO₂, SO₂, H₂S, H₂), Paramagnetic/Zirconia (O₂) |
| Temperature Range (Operating) | 10–40 °C |
| Dimensions (L×H×W) | 600 × 635 × 518 mm |
| Weight (excl. probe) | 48 kg |
| Display | 320×240 pixel backlit LCD |
| Data Storage | 256 MB MMC card |
| Analog Outputs | 8 channels, 0–10 V / 0/4–20 mA |
| Communication | RS232C |
| Power Supply | 230 VAC, 50–60 Hz |
| Sample Flow Rate | 90 L/h (adjustable diaphragm pump) |
| Condensate Handling | Peltier-cooled condensate separator with peristaltic pump |
| Heated Sampling Line | 3 m, integrated 20 µm filter |
| Probe | Heated gas probe (standard 300 mm, custom lengths available) |
| Pressure Measurement | Differential and absolute pressure sensors (±25 hPa, 800–1200 hPa), resolution 0.1–1 Pa (configurable) |
| Flow Velocity | Pitot tube-based, 1–30 m/s |
| Brand | Madur |
|---|---|
| Origin | Austria |
| Model | GA-12plus |
| Instrument Type | Portable Flue Gas Analyzer |
| Accuracy (Indication Error) | ≤5% |
| Repeatability | ≤2% |
| Response Time | 45 s |
| Stability | ≤5% |
| Optional Electrochemical Sensors | NO, NO₂, SO₂, H₂S |
| Ambient CO Resolution | 0.1 ppm |
| Temperature Measurement Range | Flue Gas & Ambient Air |
| Differential Pressure Resolution | 0.1 Pa |
| Bacharach Smoke Number Test (Electronically Controlled Flow | 1.631 L/min) |
| Calculated Parameters | CO₂, Combustion Efficiency, Excess Air, Lambda, Losses, etc. |
| Data Storage | 32 Reports |
| Display | Backlit LCD (66 × 36 mm) |
| Battery Life | Up to 75 h (6 V, 4×AA Alkaline or Rechargeable) |
| Operating Temperature | 10–50 °C |
| Storage Temperature | −20–+55 °C |
| Dimensions (W×D×H) | 245 × 90/128 × 60 mm |
| Weight | 700 g |
| Probe Length | 150 mm |
| Gas Hose Length | 2 m |
| In-line Filter | 20 µm |
| Interface | IR, RS-232C |
| Compliance | EN 50379-1 & EN 50379-2 |
| Brand | Madur |
|---|---|
| Origin | Austria |
| Model | GA-21plus |
| Instrument Type | Portable Flue Gas Analyzer (not CEMS) |
| Measurement Principle | Electrochemical (O₂, CO, NO, NO₂, SO₂, H₂S, Cl₂, H₂) & NDIR (CO₂, CH₄) |
| O₂ Range | 0–25% (electrochemical) / 0–100% (bias-cell) |
| CO Range | 0–20,000 ppm |
| NO/NOₓ Range | 0–5,000 ppm |
| NO₂ Range | 0–1,000 ppm |
| SO₂ Range | 0–5,000 ppm |
| H₂S Range | 0–1,000 ppm |
| Cl₂ Range | 0–300 ppm |
| H₂ Range | 0–1,000 ppm |
| CO₂ Range | 0.5% or 0–100% (NDIR) |
| CH₄ Range | 0.5% or 0–100% (NDIR) |
| Gas Temperature | –40 to 1600 °C |
| Ambient Temperature | –40 to 100 °C |
| Pressure Range (Differential) | –25 to +25 hPa |
| Atmospheric Pressure | 800–1200 mbar |
| Flow Velocity | 0–50 m/s |
| Response Time (T₉₀) | 45 s (gas sensors), 30 s (temperature), 10 s (pressure/flow) |
| Accuracy | ±5 ppm or ±5% rel (electrochemical gases) |
| Repeatability | 5 ppm |
| Zero Drift Stability | ≤5% over 1 h |
| Display | Backlit graphical LCD (simultaneous multi-parameter view) |
| Data Storage | Internal memory for 1024 records (10 databases), up to 10 variables per record |
| Interface | RS232C |
| Power | 230 V/50 Hz or 110 V/60 Hz AC |
| Dimensions | 460 × 170 × 160 mm |
| Weight | 6.2 kg |
| Operating Temp. | 10–50 °C |
| Storage Temp. | –20 to +55 °C |
| Probe Max Temp. | ≥800 °C |
| Compliance | Meets SCAQMD requirements including automatic O₂ correction |