Flue Gas Analyzer
Filter
Showing 181–210 of 222 results
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0632 3520 |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurement Accuracy | ±5 % of reading |
| Repeatability | ≤2 % |
| Response Time | 10 s |
| Stability | ±5 % |
| Measured Gases | CO, CO₂, NO, NO₂, SO₂, O₂ (standard), optional H₂S, CₓHᵧ, and infrared CO₂ |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0632 3520 |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurement Accuracy | ±5 % of reading |
| Repeatability | ≤2 % |
| Response Time | 10 s |
| Stability | ±5 % |
| Measurable Gases | CO, CO₂, NO, NO₂, SO₂, H₂S, and CₓHᵧ |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0632 3521 |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurement Accuracy | ±5 % of reading |
| Repeatability | ≤2 % |
| Response Time | 10 s |
| Stability | ±5 % |
| Measurable Gases | CO, CO₂, NO, NO₂, SO₂, H₂S, CₓHᵧ |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 350 |
| Instrument Type | Portable Flue Gas Analyzer |
| Accuracy (Gas Sensors) | ±5% of reading (typical, per ISO 12039 & EN 15267-3) |
| Response Time (t₉₅) | 20 s |
| Detection Gases (Configurable) | O₂, CO, NO, NO₂, SO₂, H₂S, CₓHᵧ, CO₂ (NDIR) |
| Operating Temperature | −5 °C to +45 °C |
| Storage Temperature | −20 °C to +50 °C |
| Weight | 440 g |
| Dimensions | 88 × 38 × 220 mm |
| Data Memory | 2 MB (up to 250,000 measurement values) |
| Battery Life | Up to 5 h (without wireless transmission) |
| Protection Class | IP40 |
| Temperature Probe Compatibility | K-type (−200 °C to +1370 °C), S-type (0 °C to +1760 °C), ambient probe (−20 °C to +50 °C) |
| Flow Velocity Range | 0–40 m/s |
| Dew Point Calculation Range | 0–99.9 °Ctd |
| O₂ Measurement (Electrochemical) | 0–25 Vol.% (±0.2 Vol.% accuracy) |
| CO Measurement (Electrochemical, H₂-compensated) | 0–10,000 ppm (±5% rdg or ±10 ppm, whichever greater) |
| CO₂ Measurement (NDIR) | 0–50 Vol.% (±0.3 Vol.% at 0–25 Vol.%, ±0.5 Vol.% at >25 Vol.%) |
| Optional Modules | Peltier gas conditioning unit, automatic condensate removal pump, fresh air valve (5× range extension), single-channel range extender (0×/2×/5×/10×/20×/40×), 11–40 V DC input, integrated flow sensor with auto-zero pressure compensation |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | testo 350 |
| Pricing | Upon Request |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0632 3521 |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurement Accuracy | ±5 % of reading |
| Repeatability | ≤2 % |
| Response Time | 10 s |
| Stability | ±5 % |
| Measured Gases | CO, CO₂, NO, NO₂, SO₂, H₂S, and CₓHᵧ |
| Brand | testo |
|---|---|
| Origin | Shenzhen, China |
| Model | testo 350 |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurement Principle | Electrochemical (O₂, CO, NO, NO₂, SO₂, H₂S), NDIR (CO₂, CxHy), Catalytic Combustion (CxHy) |
| Response Time (t95) | 20 s (O₂), <30 s (SO₂), <40 s (CO), <10 s (CO₂ via NDIR) |
| Accuracy | ±5% of reading (typical for electrochemical sensors), ±4 ppm (SO₂, low range), ±0.3 Vol.% + 1% (CO₂, NDIR) |
| Detection Parameters | O₂, CO, NO, NO₂, SO₂, SO₂low, H₂S, CO₂ (calculated & NDIR), CxHy (CH₄, C₃H₈, C₄H₁₀), differential pressure, ambient & flue gas temperature, velocity, dew point, efficiency, heat loss |
| Sensor Interference Compensation | CO-compensated SO₂ and SO₂low sensors (up to 10,000 ppm CO), H₂-compensated CO and COlow |
| Preconditioning | Integrated high-efficiency gas conditioning module with condensate separation, multi-stage particulate filtration, automatic dilution for high-concentration sampling |
| Connectivity | testo DataBus interface (supports up to 16 analyzers in cascade), USB, Bluetooth, Wi-Fi, LIMS-compatible data export |
| Operating Temperature | −5 °C to +45 °C |
| Battery Life | Up to 5 h (rechargeable Li-ion) |
| Dimensions | 330 × 128 × 438 mm |
| Weight | 4800 g |
| IP Rating | IP40 |
| Max. Dust Load | 20 g/m³ |
| Max. Flue Gas Pressure | −300 mbar (vacuum) / +50 mbar (overpressure) |
| Max. Flue Gas Temp (via probe) | 1800 °C (Type S) |
| Brand | Testo |
|---|---|
| Origin | Germany |
| Model | testo 350 |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurement Principle | Electrochemical (O₂, CO, NO, NO₂, SO₂, H₂S), NDIR (CO₂), Catalytic Combustion (CxHy) |
| Accuracy | ±5% of reading (for most gases, with low-range exceptions) |
| Response Time (t₉₅) | 20 s |
| Detection Gases (Configurable) | O₂, CO, COlow, NO, NOlow, NO₂, SO₂, H₂S, CO₂ (NDIR), CxHy (CH₄/C₃H₈/C₄H₁₀) |
| Operating Temperature | −5 to +45 °C |
| Storage Temperature | −20 to +50 °C |
| Dimensions | 88 × 38 × 220 mm |
| Weight | 440 g |
| Battery Life | Up to 5 h (without wireless) |
| Memory Capacity | 2 MB (~250,000 measurement values) |
| Protection Class | IP40 |
| Data Connectivity | Bluetooth® 4.0, USB, optional WLAN module |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | testo 370 |
| Instrument Type | Portable Flue Gas Analyzer |
| Accuracy (Indication Error) | < ±2% of full scale |
| Repeatability | < ±2% of full scale |
| Response Time (T90) | ≤90 s |
| Long-Term Stability | < ±2% of full scale |
| Measurable Gases | CO, NO, N₂O, NO₂, NH₃, CH₄, HCl, SO₂, CO₂, H₂O, O₂ |
| Calibration | Zero calibration using ambient air only |
| Gas Supply Requirement | None (no instrument air required) |
| Brand | Testo |
|---|---|
| Origin | Germany |
| Model | TESTO340 |
| Instrument Type | Portable Flue Gas Analyzer |
| Indication Error | < ±5% |
| Repeatability | < ±5% |
| Response Time | < 40 s |
| Stability | < ±5% |
| Measurable Gases | SO₂, CO, COlow, NO, NOlow, NO₂, O₂ |
| Differential Pressure & Flow Velocity Measurement | Built-in |
| Sensor Architecture | Modular, 3 Expandable Sensor Slots (O₂ standard |
| Fuel Database | 10 Predefined + 10 User-Defined Fuels |
| Data Interface | USB to easyEmission PC Software |
| Compliance | Designed for EN 50379-1/-2, EN 15545, VDI 3862, and applicable EPA Method 6C/7E prerequisites |
| Brand | Testo |
|---|---|
| Origin | Germany |
| Type | Portable Flue Gas Analyzer |
| Measurement Accuracy | <5% |
| Repeatability | <2% |
| Response Time | <90 s |
| Stability | <5% |
| Measured Gases | O₂, CO, NO, NO₂, SO₂ |
| Optional Sensors | CO₂ (IR), H₂S |
| Sampling Flow Rate | 1.0 L/min (regulated) |
| Data Storage Capacity | 250,000 values |
| Operating Temperature Range | –0 °C to +1000 °C (with high-temp probe) |
| Differential Pressure Range | –200 to +200 hPa |
| IP Rating | IP40 |
| Weight | 4.8 kg |
| Dimensions | 330 × 128 × 438 mm |
| Brand | Tianhong |
|---|---|
| Origin | Hubei, China |
| Model | TH-LRD-801 |
| Instrument Type | Portable Flue Gas Particulate Monitor |
| Measurement Principle | Laser Backscatter (90° scattering geometry) |
| PM Concentration Range | 0.1–10,000 mg/m³ (expandable) |
| Accuracy | ≤ ±5% of reading |
| Sensitivity | ≤ ±2% F.S. |
| Zero Drift | ≤ ±2.0% F.S./24 h |
| Span Drift | ≤ ±2.0% F.S./24 h |
| Response Time (T₉₀) | ≤ 5 s |
| Output Signals | 0–5 V DC / 4–20 mA analog |
| Operating Temperature of Sensor Baseplate | < 50 °C (maintained via integrated purge-cooling airflow) |
| Lens Cleaning | Automated pulsed air purge system |
| Temperature Compensation | Built-in NTC thermistor-based real-time compensation |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Flue Gas Continuous Emission Monitoring System (CEMS) |
| Model | Aeke SO3 |
| Measurement Principle | Quantum Cascade Laser Absorption Spectroscopy (QCLAS) |
| Calibration Method | On-site SO₂-to-SO₃ conversion via integrated catalytic converter |
| Sampling Configuration | Dilution extractive probe with inertial filter |
| Installation Flexibility | Hot/wet sampling capable |
| Data Integration | Native compatibility with DAS and DCS platforms |
| Regulatory Alignment | Designed to support EPA Method 8/204 compliance, ISO 12039, and EU EN 15267-3 requirements |
| Software Compliance | Audit-trail enabled, 21 CFR Part 11–ready data logging |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | Arke SO3 |
| Instrument Type | Continuous Emission Monitoring System (CEMS) for Sulfur Trioxide |
| Accuracy (Indicated Value Error) | ±0 ppm |
| Repeatability | <0.2 ppm (300-s average) |
| Response Time (T90) | <15 s |
| Long-Term Stability (Zero Drift, 24 h) | <0.5 ppm |
| Span Drift | ≤2% of full scale |
| Linearity | ±1% of full scale |
| H₂O Interference | <1×10⁻⁵ (relative to SO₃ signal) |
| SO₂ Interference | <1×10⁻⁴ (relative to SO₃ signal) |
| Measurement Range | 0–200 ppm |
| Zero Noise (300-s avg) | 0.2 ppm |
| Limit of Detection (LOD, 300-s avg) | 0.4 ppm |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Hg-CEMS |
| Instrument Type | Flue Gas Continuous Emission Monitoring System (CEMS) |
| Measurement Principle | Cold Vapor Atomic Fluorescence Spectrometry (CVAFS) with Catalytic Dry Conversion |
| Detection Target | Elemental Mercury (Hg⁰), Oxidized Mercury (Hg²⁺), Total Mercury |
| Detection Limit | 2 ng/m³ (300-s average) |
| Zero Noise | 1 ng/m³ (300-s average) |
| Zero Drift (24 h) | <5 ng/m³ |
| Response Time (T₉₀) | 110 s (60-s averaging) |
| Linearity | ±1% of full scale |
| Hg⁰ Range | 0–50 µg/m³ (pre-dilution) |
| Dilution Ratio | 25:1 to 100:1 |
| SO₂ Interference Rejection Ratio | 8.4×10⁸:1 |
| NOₓ Interference Rejection Ratio | 4.2×10⁹:1 |
| Operating Temperature | 5–40 °C |
| Power Supply | 100/115 VAC ±10%, 275 W |
| Dimensions (W×H×D) | 425 × 219 × 584 mm |
| Weight | 22.2 kg |
| I/O | 16 digital inputs, 10 digital outputs, 6 isolated 0–20/4–20 mA analog outputs, 8 analog inputs (0–10 V), dual RS232/RS485, built-in Ethernet (TCP/IP), Modbus support |
| Compliance | EPA Performance Specification 12A (PS-12A), 40 CFR Part 60 Appendix B, 40 CFR Part 75, ASTM D6784, ISO 15202, GLP/GMP-ready data integrity architecture |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Low-Concentration CEMS |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Measurement Parameters | SO₂, NOₓ, Particulate Matter (PM), Hg, NH₃ |
| Integrated with Thermo Fisher Analyzers | 43i (SO₂), 42i (NOₓ), 48i (CO), 410i (CO₂), 17i (NH₃), PM CEMS, Mercury Freedom™ |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | CEMS |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Measurement Principle | In-situ dilution sampling with wet-gas analysis |
| Compliance | EPA Reference Method 10, ASTM D6522, ISO 12039, EN 14181, US EPA PS-11 & PS-2 |
| Certifications | ISO 9001, China National Environmental Protection Agency (MEP) Certification, China National Technical Supervision Bureau Certification |
| Calibration | Full-system dynamic calibration (probe-to-analyzer) per EPA requirements |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | Dilution |
| Instrument Type | Flue Gas Continuous Emission Monitoring System (CEMS) |
| Measurement Accuracy | ±0.5% of full scale (typical for certified dilution CEMS per EPA PS-2 and ISO 14956) |
| Repeatability | <0.3% RSD (under stable operating conditions) |
| Response Time (T90) | <120 s for SO₂ and NOₓ |
| Long-Term Stability | <1% drift over 7 days (with daily system calibration) |
| Origin | Imported |
|---|---|
| Manufacturer Type | Distributor |
| Model | Thermo Scientific Environmental & Process Instruments |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Price Range | USD 70,000 – 140,000 |
| Measurement Accuracy | Not Specified |
| Repeatability | Not Specified |
| Response Time | Not Specified |
| Long-Term Stability | Not Specified |
| Brand | Thermo Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | FGD-CEMS |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Measurement Principle | Dilution Extraction with UV/IR Absorption and Paramagnetic/O2 Electrochemical Detection |
| Key Parameters | SO₂, NOₓ, CO, O₂, Flow Rate, Temperature, Static Pressure, Particulate Matter (PM), Relative Humidity, Total Reduced Sulfur (TRS), H₂S |
| Compliance Framework | EPA Performance Specifications (PS-2, PS-3, PS-5, PS-15), EN 15267, ISO 14001, US EPA Method 6C, Method 7E, Method 10, Method 3A, ASTM D6522, ASTM D5197 |
| Data Integrity | 21 CFR Part 11–compliant audit trail, GLP/GMP-ready reporting |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | 3880i |
| Instrument Type | Flue Gas PM CEMS |
| Measurement Principle | Dual-Method (Beta Attenuation + Tapered Element Oscillating Microbalance, TEOM) |
| Traceability | NIST-traceable mass concentration |
| Compliance | EPA PS-11, QA/QC Procedure 2, Method 5/17 Verified |
| Range | 0–250 mg/m³ (extendable to 0–5 mg/m³ low-range mode) |
| Accuracy | ±20% (uncorrected), ±10% (source-corrected) |
| Detection Limit | 0.25 mg/m³ (15-min integrated) |
| Response Time (T90) | 15 min |
| Power Supply | 200–240 VAC, 50/60 Hz, 30 A |
| Purge Air | 80 slpm at 0.55–0.7 MPa |
| Max Flue Gas Temp | 200 °C |
| Operating Ambient Temp (Controller) | 4–50 °C, non-condensing |
| Analog Outputs | 6 × 0–100 mV / 1/5/10 V, 6 × 0–20 mA / 4–20 mA |
| Digital I/O | 1 power-fail alarm, 10 relay outputs |
| Probe Dimensions | 1117.85 mm (W) × 474.73 mm (H) × 7.09 mm (D), with 914/1524 mm sheath |
| Probe Weight | 59 kg |
| Controller Dimensions | 482.6 mm (19″ W) × 189.5 mm (H) × 655.32 mm (D) |
| Controller Weight | 25 kg |
| Brand | Thermo Scientific |
|---|---|
| Model | SCR-CEMS |
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Instrument Type | Flue Gas Continuous Emission Monitoring System (CEMS) |
| Measurement Parameters | NH₃, NO, NO₂, NOₓ, O₂ |
| Dilution Ratio | Fixed 100:1 (adjustable via calibrated sonic orifice) |
| Dilution Air Supply Requirement | 0.6 MPa, ≥20 L/min |
| Sample Flow Rate | 50–300 mL/min (typ. 50 mL/min) |
| NH₃ Conversion Furnace | Integrated within probe head |
| Probe Material | Hastelloy C-276 / Inconel 625 (corrosion-resistant high-temp alloy) |
| Compliance | EPA Performance Specification 15 (PS-15), EN 15267-3, ISO 14956, US EPA Method 7E, ASTM D6522 |
| Software | Thermo Scientific™ CEMS Pro v5.x with 21 CFR Part 11-compliant audit trail and GLP/GMP data integrity features |
| Data Output | 4–20 mA analog, Modbus TCP/IP, OPC UA, FTP/SCP |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Continuous Emission Monitoring System (CEMS) |
| Model | TRS CEMS |
| Measurement Principle | Thermal Oxidation + Pulsed Fluorescence SO₂ Detection |
| Detection Targets | H₂S, CH₃SH, CH₃SCH₃, CH₃SSCH₃, CS₂, COS (reported as SO₂-equivalent concentration) |
| Dilution Ratio | 20:1 to 200:1 |
| Sample Flow Rate | 400–800 cc/min |
| Oxidation Furnace Max Temp | 1093 °C |
| SO₂ Scrubber Efficiency | >99.9% |
| Detection Limit | 0.5 ppb (300-sec avg) |
| Accuracy | ±1% of reading or ±1 ppb |
| Response Time (T₉₀) | 80 s |
| Zero Drift (24 h) | <1 ppb |
| Span Drift (24 h) | ±1% FS |
| Operating Temperature Range | 0–45 °C (analyzer), –40–50 °C (probe) |
| Output Options | 4–20 mA (isolated, optional), RS232/RS485, TCP/IP, 10 status relays |
| Compliance | Designed for EPA Method 15/16A, ASTM D5502, ISO 14687, and supports 21 CFR Part 11 audit trail requirements in configured software mode |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | UW-50 |
| Instrument Type | Continuous Emissions Monitoring System (CEMS) |
| Measurement Accuracy | ≤1.5% F.S. |
| Repeatability | 0.5% |
| Response Time | <60 s |
| Stability | ≤±2% F.S./7 days (zero & span drift) |
| Measured Gases | SO₂, NO, CO₂ |
| Brand | Tianhong |
|---|---|
| Origin | Hubei, China |
| Model | TH-2000PMd |
| Instrument Type | Continuous Emission Monitoring System (CEMS) for Particulate Matter |
| Measurement Principle | β-ray attenuation with Dynamic Heating System (DHS) |
| Measurable Fractions | TSP, PM₁₀, PM₂.₅, PM₁.₀ |
| Display | 7-inch capacitive touchscreen (Chinese UI) |
| Data Storage | ≥1 year internal flash memory |
| Communication | Embedded GPRS module, digital (RS485/RS232) and analog (4–20 mA) outputs |
| Environmental Rating | IP55-rated enclosure, operational without external shelter |
| Temperature Control | Integrated thermostatic chamber |
| Compliance | HJ 653–2013, HJ 655–2013, HJ 93–2013 |
| Response Time | ≤1 min (T₉₀) |
| Accuracy | ±1 µg/m³ (as per HJ 653–2013 reference method validation) |
| Repeatability | ≤1% RSD |
| Long-term Drift | ≤1 µg/m³/30 days |
| Brand | Tianhong |
|---|---|
| Origin | Hubei, China |
| Model | TH-600C |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurement Accuracy | ±5% FS |
| Repeatability | ±2% FS |
| Response Time | 90 s |
| Stability | ±5% FS over 2 h |
| Measured Gases | NOₓ, SO₂, CO, CO₂, O₂ |
| Flow Rate (No Load) | 2.5 L/min |
| Flow Rate (at –20 kPa Load) | ≥1.5 L/min |
| Sampling Method | Dual-channel independent isokinetic sampling with pre-sampling purge and automatic line purging |
| Brand | Tianhong |
|---|---|
| Origin | Hubei, China |
| Model | TH-860 |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Measurement Error | ±5% FS |
| Repeatability | ≤2% RSD |
| Response Time | ≤200 s |
| Drift Stability | ≤5% / h |
| Measured Parameters | SO₂, NOₓ |
| Detection Limit | 0.5 ppb (SO₂ and NOₓ) |
| Dilution Ratio Range | 50:1 to 250:1 |
| O₂ Measurement Method | Electrochemical or Zirconia Sensor |
| Brand | Tianhong |
|---|---|
| Origin | Hubei, China |
| Model | TH-870 |
| Instrument Type | Flue Gas CEMS |
| Repeatability | ±2% FS |
| Response Time | ≤200 s |
| Stability | ±5% FS over 7 days |
| Measured Gases | SO₂, SO₃, NO, NO₂, HCl, HF, O₂, CO, CO₂ |
| Preconditioning | Nafion™ membrane-based dryers |
| Detection Principle | Low-range NDIR (SO₂, NOₓ, CO, CO₂), Electrochemical/Zirconia (O₂) |
| Brand | Tianhong |
|---|---|
| Origin | Hubei, China |
| Model | TH-880 |
| Instrument Type | Portable Flue Gas & Particulate Sampler |
| Sensor Integration | Optional electrochemical sensors (SO₂, CO, O₂, NOₓ) |
| Compliance Basis | Designed for compliance with GB/T 16157–1996, HJ/T 48–1999, and ISO 9096:2003 principles |
| Operating Principle | Pitot-static parallel isokinetic sampling with real-time velocity tracking |
| Brand | Tianhong |
|---|---|
| Origin | Hubei, China |
| Model | TH-880F |
| Power Supply | AC 220 V ±10%, 50 Hz or DC 12 V (with external power box) |
| Operating Temperature | −20 to 50 °C |
| Relative Humidity | 0–95 % RH |
| Atmospheric Pressure Range | 86–106 kPa |
| Data Storage | Onboard memory for ≥45,000 sample records |
| Flow Tracking Response Time | <4 s |
| Display | Industrial-grade 320×240 dot-matrix LCD with 180° mechanical tilt adjustment |
| Compliance | Designed for EPA Method 5/17/26A, ISO 9096, GB/T 16157, HJ/T 48–1999, HJ 836–2017 |
