| Brand | Ailun General / Qingdao Ailun |
|---|---|
| Origin | Shandong, China |
| Model | AL-2051 |
| Sampling Flow Rate | 0.2–1.5 L/min |
| Flow Accuracy | ±0.1% (full scale) |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Continuous Operation Time | >15 h |
| Operating Temperature | −20 to +45 °C |
| Operating Humidity | 0–95% RH |
| Dimensions | 240 × 180 × 240 mm |
| Weight | ~2 kg |
| Compliance | HJ/T 47–1999 |
| Brand | Ailun General / Qingdao Ailun |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HB6020 |
| Instrument Type | Flue Gas and Particulate Sampler |
| Measured Gases | O₂, SO₂, NO, NO₂, CO, CO₂, H₂S |
| Flow Accuracy | ≤ ±4.0% |
| Maximum Cumulative Sampling Volume | 999,999.9 L |
| Flue Gas Velocity Range | 1–45 m/s |
| Moisture Content Range | 0–60% |
| Brand | Ailun General / Qingdao Ailun |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HB6040 |
| Price Range | USD 14,000–42,000 (FOB) |
| Instrument Type | In-situ UV Absorption Flue Gas Analyzer |
| Measured Gases | SO₂, NO, NO₂, CO, CS₂, H₂S, NH₃ |
| Flow Accuracy | ≤ ±2 % FS |
| Sampling Flow Rate | 0.5–1.5 L/min |
| Flue Gas Velocity Range | 5–30 m/s |
| Moisture Content Measurement Range | 0.1–40.0 % v/v |
| Brand | AMAE |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AC-3072C |
| Instrument Type | Flue Gas Sampler |
| Sampling Flow Rate | 200–2000 mL/min |
| Brand | AMAE |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AC-5000A |
| Instrument Type | Flue Gas and Ambient Air VOC Sampler |
| Sampling Flow Rate | 10–200 mL/min |
| Brand | AMAE |
|---|---|
| Origin | Guangdong, China |
| Model | EM-3088-4.0 |
| Sampling Flow Rate | 0–110 L/min |
| Flow Accuracy | ±5% or better |
| Sample Type | Isokinetic particulate sampling + flue gas component analysis (O₂, SO₂, CO, NO, NO₂, H₂S, CO₂) |
| Compliance | Designed for fixed-source emission monitoring per Chinese EPA HJ/T 47–1999, HJ/T 48–1999, and compatible with ISO 16911-1:2013 principles |
| Power | Integrated rechargeable battery for field operation |
| Water Removal | Triple-stage condensate removal with auto-drain function |
| Data Output | Real-time parametric logging including stack temperature, static/dynamic pressure, atmospheric pressure, moisture content, flow velocity, and volumetric flow |
| Brand | AMAE |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | EM-3088S |
| Price Range | USD 16,500 – 20,500 |
| Instrument Type | Flue Gas and Particulate Sampler |
| Sample Application | Isokinetic particulate sampling and real-time flue gas component analysis in exhaust ducts under industrial operating conditions |
| Sampling Flow Rate | 0–110 L/min |
| Flow Accuracy | ±5% or better |
| Flue Gas Velocity Range (Isokinetic Suction) | 1–50 m/s |
| Moisture Tolerance | Relative Humidity ≤95% RH |
| Brand | AMS |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | AMS Flue Gas Heavy Metal Sampler |
| Instrument Type | Particulate and Heavy Metal Sampling System |
| Target Analytes | Heavy Metals (e.g., Pb, Cd, Hg, As, Ni, Cr) |
| Flow Accuracy | ±2% |
| Compliance Standard | UNI-EN 14385 |
| Brand | AMS |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AMS Flue Gas Particulate Sampling System |
| Instrument Type | Isokinetic Particulate Sampler |
| Flow Accuracy | ±2% |
| Brand | AMS |
|---|---|
| Origin | Italy |
| Model | AMS Dioxin |
| Instrument Type | Flue Gas Dioxin Sampling System |
| Flow Accuracy | ±2% |
| Compliance | UNI-EN 1948:2006 |
| Sampling Methods | Filter-Condensation, Dilution, Cooled Probe |
| Primary Adsorbent | XAD-2 Resin or PUF Foam |
| Heating Zone Temperature | <125 °C (maintained above gas dew point) |
| Condenser Outlet Temperature | <20 °C |
| Main Flow Rate | 3–5 m³/h |
| Side Stream Flow Rate | 0.5–0.7 m³/h |
| Side-to-Main Flow Ratio Tolerance | ±10% |
| Linear Velocity in XAD-2 Tube | ≤34 cm/s |
| Brand | AMS |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AMS HCl Flue Gas Sampling System |
| Instrument Type | Flue Gas Sampling System |
| Flow Accuracy | ±2% |
| Compliance | EN 1911, ISO 9096:1992 |
| Operating Probe Temperature | ≥120 °C (≥20 °C above HCl acid dew point) |
| Filter Efficiency | >99.5% (glass fiber or quartz fiber) |
| Sample Transit Time | <5 s (nozzle to impinger) |
| Main Stream Flow Rate | 30–150 L/min (isokinetic mode) |
| Impinger Flow Rate | 2–3 L/min |
| Typical Sampling Volume | 50–200 L (for [HCl] = 1–10 mg/m³ |
| Brand | AMS |
|---|---|
| Origin | Italy |
| Model | AMS Mercury Sampling System |
| Instrument Type | Flue Gas Sampling System |
| Target Analyte | Mercury (Hg) and Other Heavy Metals |
| Flow Accuracy | ±2% |
| Compliance | UNI-EN 13211 |
| Sample Path Material | Borosilicate Glass & Inert Heated Components |
| Probe Operating Temperature | ≥120 °C (≥20 °C above acid dew point) |
| Max. Sample Residence Time | <5 s (from probe inlet to impinger train) |
| Brand | AMS |
|---|---|
| Origin | Italy |
| Model | Stack Gas2001 (600/ISS1400K) |
| Instrument Type | Heated Flue Gas Sampling Probe |
| Flow Accuracy | ±2% of full scale |
| Probe Length Options | 350 mm / 750 mm |
| Heating Element | Integrated, temperature-controlled |
| Filter | In-probe heated particulate filter (ceramic or sintered metal, typical operating temp: 180–200 °C) |
| Power Supply | Internal 14 Ah sealed lead-acid battery (rechargeable, designed for ≥500 cycles) |
| Sampling Line Assembly | Dual-layer polyethylene tubing (1.25 m length), integrated cooling jacket + electronic control unit (P/N 2100152) |
| Optional Integration | Compatible with DiluGas™ dynamic dilution system (dual-input interface) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | XC-260 |
| Price Range | USD 7,000 – 14,000 |
| Flow Range Options | 0.2–2.4 L/min or 100–1000 mL/min (XC-260A variant) |
| Dry Gas Meter | Positive-displacement diaphragm type, 0.7 L/rev, 8-digit LCD display, 1 mL resolution |
| Dual Diaphragm Pump | 12 V DC motor, max vacuum 20 inHg |
| Temperature Display | Digital, °C |
| Thermocouple Inputs | Five external K-type, two internal flowmeter temperature sensors |
| Dimensions | 50 × 53 × 30.5 cm |
| Weight | 17.7 kg |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | XC-5000 |
| Price Range | USD 7,000 – 14,000 |
| Brand | BCT |
|---|---|
| Origin | Italy |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | BCT QB-D |
| Instrument Type | Flue Gas Sampler |
| Sample Type | Flue Gas |
| Flow Accuracy | ±0.1% |
| Sampling Flow Rate | 5 mL/s |
| Flue Gas Velocity | 1 m/s |
| Moisture Content | 5% |
| Brand | BCT |
|---|---|
| Origin | Italy |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | BCT SF PU |
| Instrument Type | Flue Gas and Particulate Sampler |
| Target Analytes | Heavy Metals, Polycyclic Aromatic Hydrocarbons (PAHs), Polychlorinated Dibenzo-p-dioxins and Dibenzofurans (PCDD/PCDF) |
| Flow Accuracy | ±1% |
| Sampling Flow Rate | 4.5–8.5 m³/h |
| Flue Gas Velocity Range | 100–500 L/min |
| Moisture Content Tolerance | 10% |
| Brand | BCT |
|---|---|
| Origin | Italy |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | BCT SG5 |
| Instrument Type | Flue Gas and Particulate Sampler |
| Sample Type | Flue Gas |
| Flow Accuracy | ±2% |
| Sampling Flow Rate | 5–60 L/min |
| Flue Gas Velocity Range | 0.4–6.0 m³/h |
| Moisture Content Detection Limit | 0.1% |
| Origin | Qingdao, Shandong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | 3012H |
| Pricing | Available Upon Request |
| Sampling Principle | Isokinetic Sampling via Pitot Tube + Gravimetric Collection |
| Gas Detection Method | Potentiostatic Electrolysis |
| Operating Power | AC 220 V ±10%, 50 Hz or DC 12 V |
| Dimensions | 450 × 168 × 410 mm |
| Weight | ~10.0 kg |
| Noise Level | <65 dB(A) |
| Power Consumption | <180 W |
| Data Storage Capacity | >100,000 measurement records |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GHK-2900 |
| Instrument Type | Flue Gas Sampling Preconditioner |
| Dehumidification Technology | Integrated Peltier Cooling + Nafion® Membrane Permeation |
| Filtration | Dual-stage particulate filtration (≤0.3 µm) |
| Temperature Control | PID-regulated heating & cooling (±0.8 °C stability) |
| Condensate Management | Programmable peristaltic pump drainage |
| Sample Line | Fully heated sampling probe and PTFE-lined transport tubing |
| Real-time Monitoring | Displayed dew point temperature and absolute humidity (g/m³) |
| Brand | Guo Ruili Heng |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | GR-3100D-6 |
| Instrument Type | Flue Gas and Particulate Sampler |
| Sample Parameters | Dynamic Pressure, Static Pressure, Flow Velocity, Pre-Flowmeter Pressure, Pre-Flowmeter Temperature, Flue Gas Temperature, Moisture Content, O₂, SO₂, CO, NO, NO₂, H₂S, CO₂ |
| Flow Accuracy | ≤ ±5% |
| Sampling Flow Rate | 0–100 L/min |
| Flue Gas Velocity Range | 1–45 m/s |
| Moisture Content Range | 0–60% |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | GHK-2000 |
| Instrument Type | Flue Gas Sampler |
| Sample Type | Flue Gas |
| Sampling Flow Rate | 0.1–1.5 L/min |
| Flue Gas Velocity | 1–45 m/s |
| Moisture Content Range | 0–60% |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GHK-2000E |
| Instrument Category | Flue Gas and Particulate Sampler |
| Sampling Flow Rate | 5–60 L/min |
| Moisture Content Range | 0–60% |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GHK-2000L |
| Instrument Category | Flue Gas Sampling System |
| Target Analyte | Hydrogen Chloride (HCl) |
| Compliance Standards | HJ 547–2017, HJ 548–2016, HJ 549–2016 |
| Sampling Configuration | Heated Probe + PTFE Filter Cartridge + Temperature-Controlled Absorption Bottles + Condensation Management Unit |
| Heating Range | 0–60 °C |
| Temperature Control Accuracy | ±2 °C |
| Absorption Bottle Capacity | 6 positions (including blank and sample) |
| Filter Medium | Cellulose Acetate Microporous Membrane |
| Tubing Material | Fluorosilicone Insulated Tubing with Anti-Adsorption Lining |
| Internal Probe Liner | PTFE (non-adsorptive) |
| Filter Housing & Support Mesh | PTFE-coated |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | GHK-2000Q |
| Instrument Category | Flue Gas Sampling System |
| Target Analytes | Aldehydes and Ketones (e.g., formaldehyde, acetaldehyde, acetone, propionaldehyde) |
| Operating Temperature Range | −30 °C to +50 °C |
| Sampling Gun Heating Range | 0–200 °C |
| Dual-Channel Flow Control | Independent constant-flow sampling (±10% tolerance |
| Data Storage | 200 entries with time-stamped flow, temperature, pressure, and volume data |
| Power Supply | Integrated high-capacity lithium battery powering host, heated box, trace-heated line, and sampling probe |
| Compliance | GB/T 16157–1996, HJ 1153–2020 |
| Key Features | Light-shielded isothermal sample preservation, anti-backflow desiccant bottle, real-time standard-volume correction (STP), ambient temperature & barometric pressure sensing, brushless diaphragm pump, IP-rated weather-resistant enclosure |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | GHK-2000W |
| Instrument Type | Flue Gas VOC Sampler |
| Compliance Standards | HJ 734–2014, HJ 644–2013, HJ 583–2010, HJ 584–2010, HJ 801–2016 |
| Sampling Method | Solid-phase Adsorption with Thermal Desorption |
| Cooling Range | 0–5 °C (adsorbent tube compartment) |
| Filtration | Integrated 2 µm sintered metal filter |
| Heating Control | PID-regulated, ±2 °C accuracy |
| Data Storage | Up to 1000 sampling records |
| Optional | Bluetooth thermal printer module |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | GHK-2100 |
| Instrument Type | Flue Gas and Particulate Sampler |
| Sampled Gases | O₂, SO₂, NO, NO₂, CO, H₂S, CO₂ (configurable) |
| Sampling Flow Rate | 0–100 L/min |
| Flow Accuracy | ≤ ±2.5% FS |
| Flue Gas Velocity Range | 1–45 m/s |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Regional Classification | Domestic (China) |
| Model | GHK-2200 |
| Instrument Type | Flue Gas Particulate Sampler |
| Flue Gas Velocity Range | 1–45 m/s |
| Measurement Principle | Beta-Ray Absorption Gravimetry |
| Regulatory Compliance | GB/T 16157–1996, HJ/T 397–2007, DB37/T 3785–2019 |
| Optional Modules | Integrated Humidity Sensor, Heated Filter Tape Transport System, Modular Pitot Tube, IoT Data Transmission Module, USB Mass Storage Export |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GHK-2300 |
| Instrument Type | Flue Gas Sampling and Analysis System |
| Sampling Flow Rate | 1.0 L/min |
| Flue Gas Velocity Range | 1–45 m/s |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Key Measured Gases | SO₂, NOₓ (NO/NO₂), CO₂, CO, H₂S, O₂, CH₄, N₂O |
| Integrated Humidity Sensor | Yes |
| Operating Temperature Range | –20 °C to 50 °C |
| Power Supply | DC 12–26 V / AC 80–260 V |
| Battery Runtime | >4 h (host + probe) |
| Data Storage | High-Capacity Internal Memory with USB Export |
| Connectivity | Bluetooth (printer), Optional IoT Module for Remote Transmission |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | GHK-2901 |
| Instrument Type | Flue Gas Preconditioner |
| Sample Type | Flue Gas |
| Compliance Standard | HJ/T 47–1999 “Technical Specifications for Flue Gas Samplers” |
| Cooling Method | High-Power Compressor-Based Refrigeration |
| Minimum Refrigeration Temperature | –10 °C |
| Heating & Cooling Control | Dual-Screen PID Control |
| Sample Line Material | PTFE-Lined Tubing |
| Filtration | Dual-Stage — Sintered Metal + PTFE Membrane |
| Condensate Removal | External Peristaltic Pump with Visual Chamber |
| Electrical Safety | Low-Voltage DC for Heating/Refrigeration Circuits |
| Connection Interface | Quick-Connect Fittings for Gas and Power |