Food Specialized Instruments
Filter
Showing 421–450 of 786 results
| Brand | NIUMAG |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | PQ001-20-025V |
| Pricing | Available Upon Request |
| Magnet Type | Permanent Magnet |
| Magnetic Field Strength | 0.5 ± 0.08 T |
| Probe Coil Diameter | 25 mm |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PQ001-SFC |
| Pricing | Available Upon Request |
| Magnet Type | Permanent Magnet |
| Magnetic Field Strength | 0.5 ± 0.08 T |
| Larmor Frequency | 21.3 MHz |
| Probe Coil Diameter | 10 mm |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PQ001-ZF |
| Quotation | Upon Request |
| Magnet Type | Permanent Magnet |
| Magnetic Field Strength | 0.5 ± 0.08 T |
| Brand | NovaSina |
|---|---|
| Origin | Switzerland |
| Model | LabMaster-aw neo |
| Measurement Range | 0.0300–1.000 aw |
| Accuracy | ±0.0001 aw |
| Temperature Control Range | 0–60 °C |
| Temperature Stability | ±0.01 °C |
| Display | 240 × 480 LCD |
| Dimensions | 260 × 440 × 220 mm |
| Weight | 9.8 kg |
| Power Supply | 90–260 V, 50/60 Hz, max. 65 W |
| Protection Rating | IP21 |
| Interface | RS-232, USB, D-Sub 9M/9F |
| Brand | Novasina |
|---|---|
| Origin | Switzerland |
| Model | LabMaster-aw neo |
| Measurement Range | 0.0300–1.000 aw |
| Temperature Control Range | 0–60 °C |
| Temperature Stability | ±0.01 °C |
| Display | 240 × 480 LCD |
| Interface | RS-232, USB, D-Sub 9M/9F |
| Dimensions | 260 × 440 × 220 mm |
| Weight | 9.8 kg |
| Power Supply | 90–260 VAC, 50/60 Hz, max. 65 W |
| Protection Class | IP21 |
| Sensor Technology | NOVALYTE® Electrolytic Conductivity Sensor (Contactless, Maintenance-Free) |
| Calibration Standards | Factory-supplied saturated salt solutions (4–100% RH equivalent) |
| Brand | NovaSina |
|---|---|
| Origin | Switzerland |
| Model | LabStart-aw |
| Instrument Type | Portable |
| Measurement Range | 0.030–1.000 aw |
| Accuracy | ±0.01 aw |
| Temperature Range | 15–30 °C |
| Temperature Accuracy | ±0.1 °C |
| Display | Backlit LCD (shows aw, temperature, RH%) |
| Weight | 1 kg |
| Sample Cup Capacity | 20 reusable cups included |
| Calibration Standard | Non-consumable, multi-year service life |
| Brand | Novasina |
|---|---|
| Origin | Switzerland |
| Model | LabStart-aw |
| Measurement Range | 0.030–1.000 aw |
| Operating Environment | 5–40 °C, ≤85% RH (non-condensing) |
| Sensor Type | CM-4 Capacitive Electrolyte Sensor |
| Temperature Control | None (ambient measurement only) |
| Temperature Range for Measurement | 15–30 °C |
| Temperature Accuracy | ±0.3 K |
| Resolution | 0.01 aw |
| Accuracy | ±0.03 aw |
| Display | Backlit LCD (aw, °C, %RH) |
| Sample Cups | 20 reusable stainless-steel cups included |
| Data Storage | None (real-time readout only) |
| Power Supply | 90–264 VAC, 50–60 Hz |
| Dimensions (H×W×D) | 85 × 140 × 225 mm |
| Weight | 1.2 kg |
| Brand | NovaSina |
|---|---|
| Origin | Switzerland |
| Model | LabSwift-aw |
| Instrument Type | Portable |
| Measurement Range | 0.03–1.000 a<sub>w</sub> |
| Accuracy | ±0.001 a<sub>w</sub> |
| Temperature Operating Range | 5–45 °C |
| Host Weight | 1.2 kg |
| Calibration | Factory-performed 6-point calibration |
| Data Storage | Integrated SD card |
| Display | Large LCD |
| Brand | Novasina |
|---|---|
| Origin | Switzerland |
| Model | LabSwift-aw |
| Measurement Range | 0.03–1.000 aw |
| Resolution | 0.01 aw |
| Accuracy | ±0.01 aw |
| Temperature Range | 5–45 °C |
| Temperature Accuracy | ±0.15 K |
| Weight | 1.2 kg |
| Data Storage | SD card |
| Calibration | Factory 6-point certified calibration |
| Sensor Type | CM-2 dual-electrolyte resistive sensor |
| Compliance | NIST-traceable, FDA-recommended, ISO 21807 compliant |
| Brand | Novasina |
|---|---|
| Origin | Switzerland |
| Model | LabTouch-aw |
| Measurement Range | 0.030–1.000 aw |
| Temperature Control Range | 15–30 °C |
| Accuracy | ±0.001 aw |
| Temperature Accuracy | ±0.1 °C |
| Display | Full-color TFT touchscreen |
| Probe Type | Patented Resistive Electrolyte Sensor (REMS) |
| Standard Reference | Long-life saturated salt solution standards |
| Host Weight | 1 kg |
| Compliance | NIST-traceable calibration, FDA-recognized methodology, ISO 21807, AOAC 975.34, USP <1112> |
| Brand | Novasina |
|---|---|
| Origin | Switzerland |
| Model | LabTouch-aw |
| Measurement Range | 0.030–1.000 aw |
| Operating Temperature | 5–45 °C |
| Temperature Control Range | 15–30 °C |
| Temperature Accuracy | ±0.15 K |
| Water Activity Resolution | 0.01 aw |
| Water Activity Accuracy | ±0.005 aw |
| Display | Large LCD touch screen |
| Data Storage | Internal memory for test data and methods |
| Connectivity | SD card, RS-232, USB |
| Dimensions (H×W×D) | 105 × 200 × 300 mm |
| Weight | 2.8 kg |
| Brand | OASIS |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LZ-7000 |
| Detection Method | Combined Spectrophotometric and Dry-Chemistry Assay |
| Measurement Range | 0–100% inhibition |
| Number of Channels | 36 |
| Measurement Error | ≤5% |
| Limit of Detection (LOD) | 0.01 mg/kg |
| Display | Color capacitive touchscreen |
| Storage | MicroSD (TF) card expandable |
| Connectivity | Wi-Fi, Bluetooth, Ethernet |
| Interfaces | USB 2.0, RJ45 Ethernet, HDMI |
| Power Supply | DC 12 V (adapter included) |
| Battery | Built-in high-capacity rechargeable Li-ion battery |
| Processor | Multi-core 1.8 GHz ARM-based SoC |
| Data Output | Integrated thermal printer + external printer support |
| GPS | Built-in GNSS module for geotagging |
| Brand | OMNION |
|---|---|
| Origin | USA |
| Model | OSI-24 |
| Temperature Range | 40–220 °C |
| Sample Capacity | 24 positions |
| Compliance | AOCS Cd 12b-92, ISO 6886:2006, EN 14112, JOCS, GB/T 21121 |
| Temperature Accuracy | ±0.1 °C |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | OSI-6 |
| Price Range | USD 27,000 – 68,000 |
| Origin | Denmark |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Oxidograph |
| Pricing | Available Upon Request |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | SKD-100 |
| Principle | Kjeldahl Method |
| Nitrogen Range | 0.1–240 mg N |
| Repeatability | RSD ≤ 0.5% |
| Detection Limit | 0.1–240 mg N |
| Recovery Rate | >99.5% |
| Sample Capacity | ≤6 g (solid) or ≤16 mL (liquid) |
| Distillation Time | 3–8 min/sample |
| Distillation Flow Rate | 15–30 mL/min |
| Alkali Addition Time | 0–99 s |
| Distillation Duration Setting | 0–99 min |
| Power Adjustment | 0–1500 W |
| Data Storage | 10 programmable distillation/alkalization protocols |
| Safety Features | Real-time liquid-level monitoring, overpressure protection, dry-run prevention, emergency stop |
| Housing Material | Integrated ABS engineering plastic enclosure |
| Tubing | Acid- and alkali-resistant custom polymer tubing (≥3-year service life) |
| Dimensions | 370 × 300 × 680 mm |
| Net Weight | 15 kg |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Water Supply | ≥0.15 MPa pressure, ≤20 °C inlet temperature |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | SKD-200 |
| Measurement Principle | Kjeldahl Method |
| Nitrogen Range | 0.1–240 mg N |
| Repeatability | ±0.5% RSD |
| Detection Limit | 0.1–240 mg N |
| Recovery Rate | >99.5% |
| Sample Capacity | ≤6 g (solid) or ≤16 mL (liquid) |
| Distillation Time | 3–8 min/sample |
| Distillation Flow Rate | 15–30 mL/min |
| Power Adjustment | 0–1500 W |
| Alkali Addition Time | 0–99 s (stepwise) |
| Acid Addition Time | 0–99 s |
| Distillation Duration Setting | 0–99 min |
| Data Storage | 10 programmable methods |
| Safety Features | Overpressure protection, dry-run prevention via real-time liquid level monitoring, emergency stop |
| Housing Material | Molded ABS engineering plastic (acid/alkali resistant) |
| Tubing | Custom corrosion-resistant polymer tubing (≥3-year service life) |
| Dimensions | 370 × 300 × 680 mm |
| Net Weight | 15 kg |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Cooling Water Requirement | ≥0.15 MPa pressure, ≤20 °C inlet temperature |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | SKD-2000 |
| Principle | Kjeldahl digestion and distillation followed by colorimetric titration |
| Nitrogen Range | 0.1–240 mg N |
| Repeatability | RSD ≤ 0.5% |
| Detection Limit | 0.1–240 mg N |
| Recovery Rate | >99.5% |
| Distillation Time | 3–8 min/sample |
| Distillation Rate | 15–30 mL/min (adjustable) |
| Titration Resolution | 0.002 µL/step |
| Minimum Titration Volume | 0.8 µL/step |
| Sample Capacity | ≤6 g solid or ≤16 mL liquid |
| Alkali Addition | 1–10 segments, 0–15 s interval |
| Delay Time | 0–1800 s |
| Dimensions | 500 × 350 × 720 mm |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SKD-800 |
| Price Range | USD 1,400 – 7,200 (FOB) |
| Instrument Type | Protein Nitrogen Determinator |
| Measurement Principle | Classical Kjeldahl Method |
| Nitrogen Recovery Rate | >99.5% |
| Repeatability (RSD) | <0.5% |
| Detection Range | 0.08–240 mg N |
| Sample Capacity | ≤6 g solid or ≤16 mL liquid |
| Distillation Time | 1–99 min |
| Adjustable Distillation Power | 1500 W |
| Distillation Flow Rate | 15–30 mL/min |
| Data Storage | 100 pre-programmed methods + >1,000 sample records |
| Cooling Water Requirement | ≥1.5 L/min at ≤20 °C |
| Operating Pressure | ≥0.15 MPa |
| Dimensions (W×D×H) | 370 × 300 × 680 mm |
| Enclosure Material | Molded ABS engineering plastic |
| Brand | Perten |
|---|---|
| Origin | Sweden |
| Model | PaddyCheck™ PC 6800 |
| Compliance | AACCI Method No. 61-10.01 |
| Power | Rechargeable battery (3 h analysis / 8 h standby) |
| Dimensions | Compact, portable design |
| Sensor Suite | Polarized light sensor, visible-light RGB sensor, precision force sensor (17 N max load) |
| Brand | Perkone |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PF-E |
| Price Range | USD 7,000 – 14,000 |
| Mixing Bowl Capacity | 300 g |
| Torque Range | 0–1000 FU |
| Torque Accuracy | ≤0.5% of full scale |
| Torque Measurement | Electronic transducer |
| Main Mixer Blade Speed | 63 rpm |
| Auxiliary Mixer Blade Speed | 94.5 rpm |
| Mixing Bowl & Blades | German-sourced hardened stainless steel (corrosion- and wear-resistant, >10-year service life) |
| Dropper Tip Material | PTFE |
| Interchangeable Mixing Heads | Yes |
| Includes | Farinograph主机, thermal printer, water supply unit, thermostatic water bath (±0.2°C stability), dual calibrated burettes, proprietary farinogram analysis software |
| Brand | Perten |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | doughLAB |
| Price Range | USD 68,000 – 109,000 |
| Torque Measurement Range | 0–25 N·m |
| Rotational Speed Range | 0 or 10–200 rpm |
| Temperature Control Range | 10–80 °C (standard), with ±0.2 °C stability at 30 °C |
| Water Dispensing Range | 1–300 mL |
| Sample Bowl Options | 50 g or 300 g |
| Dimensions (H×W×D) | 970 × 490 × 370 mm |
| Weight | 91 kg (with bowl), 70 kg (without bowl) |
| Ambient Operating Conditions | 5–40 °C, <80% RH at 31 °C |
| Data Interface | RS-232 to USB converter |
| Brand | Perten |
|---|---|
| Origin | Sweden |
| Model | FN1000 |
| Compliance | ASTM/ICC/AACC/ISO/GB Standards |
| Sample Type | Wheat, Durum, Rye, Barley, Flour, and Other Cereal Grains |
| Measurement Principle | Viscosity-based enzymatic hydrolysis kinetics (Hagberg-Perten method) |
| Temperature Control | Precise 100 °C water bath with auto-leveling system |
| Dispensing Accuracy | 25.0 ± 0.2 mL deionized water per test |
| Display | 5.7″ color touchscreen with multilingual UI (including Chinese) |
| Connectivity | USB 2.0 + Ethernet (RJ45) for LIMS integration, barcode readers, and thermal printers |
| Altitude Compensation | Automatic correction above 610 m (2000 ft) ASL |
| Dual-Mode Operation | Standard Falling Number (FN) and Fungal Falling Number (FFN) via firmware switch |
| Data Management | Sample ID registration, moisture-corrected reporting, audit-ready result logs |
| Brand | Perten |
|---|---|
| Origin | Sweden |
| Model | GM2000 |
| Gluten Washing Time | 5 min |
| Mixer Speed | 120 ± 5 rpm |
| Dough Mixing Time | 20 s |
| Compliance | AACC 38-12.02, ICC 155/158/137/1, ISO 21415-2 & -4, GB/T 5506.2 & 5506.4, IRAM 15864, CCAT Method 13 |
| Brand | Perten |
|---|---|
| Origin | Sweden |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LactoScope 300™ FT-IR |
| Detection Scope | Raw milk (cow, goat, sheep, camel), cream, whey, pasteurized milk, formulated milk, dairy beverages |
| Automation Level | Semi-automatic |
| Throughput | 60–80 samples/hour |
| Repeatability | ≤1.2% CV |
| Accuracy | ≤0.5% CV |
| Operating System | Windows 10 |
| Software Interface | Fully localized Chinese GUI with stepwise workflow navigation |
| Calibration Modules | Pre-configured, ready-to-use calibration packs for raw milk, cream, whey, pasteurized milk, goat milk, sheep milk |
| Data Storage | SQL-based database architecture with backup/restore capability and external storage support |
| Protein Range | 0–15% w/w |
| Measurement Principle | Fourier Transform Infrared Spectroscopy (FT-IR) with patented Dynascan™ interferometer |
| Brand | Perten |
|---|---|
| Origin | Netherlands |
| Model | LactoScope FT-A |
| Automation Level | Semi-automatic |
| Analysis Speed | 100–120 samples/hour |
| Measurement Range | Fat: 0–55% |
| Protein | 0–25% (including 0–15% for protein-specific quantification) |
| Lactose | 0–22% |
| Total Solids | 0–60% |
| Repeatability | ≤ 0.25% CV |
| Accuracy | < 1% CV |
| Operating System | Windows-based |
| Interface Language | English (localized UI available) |
| Calibration Kits | Pre-validated, ready-to-use modules for raw milk, cream, whey, flavored milk, and yogurt |
| Data Storage | SQL database architecture with backup, restore, and external storage support |
| Optical Technology | Mid-infrared (MIR) Fourier Transform Infrared Spectroscopy |
| Measurement Time | 30–45 seconds per sample |
| Interferometer | Patented Dynascan™ technology |
| Environmental Protection | OpticsGuard™ desiccation system with molecular sieve |
| Brand | Perten |
|---|---|
| Origin | Netherlands |
| Model | LactoScope FT-B |
| Automation Level | Semi-Automatic |
| Analysis Speed | 60–80 samples/hour |
| Detection Range | Fat: 0–40% |
| Protein | 0–15% |
| Lactose | 0–15% |
| Total Solids | 0–45% |
| Repeatability | ≤0.25% CV |
| Accuracy | <1% CV |
| Operating System | Windows-based GUI with localized Chinese interface |
| Calibration Kits | Pre-validated modules for raw milk, cream (up to 40% fat), whey, flavored milk, and yogurt |
| Data Storage | SQL database architecture with backup/recovery support and external storage compatibility |
| Optical System | Dynascan™ interferometer-based FTIR with OpticsGuard™ desiccation and molecular sieve protection |
| Compliance | ISO 9622 / IDF 141, AOAC 972.16, ICAR-certified |
| Sample Volume | 10 mL |
| Sample Temperature Range | 4–42 °C |
| Dimensions (W×D×H) | 49 × 70 × 49 cm |
| Weight | 86 kg |
| Power Supply | 100–120 V, 60 Hz or 220–240 V, 50 Hz |
| Brand | Perten |
|---|---|
| Origin | Imported |
| Model | RVA 4500 |
| Viscosity Range | 20–50,000 cP (at 80 rpm) |
| Measurement Time | 3 min (stirring value) |
| Sample Mass | 2–3 g |
| Compliance | GB/T 22427.7-2023, GB/T 24852-2010, GB/T 24853-2010, AACC 61-02 (1995), AACC 22-08 (1995), AACC 76-21 (1997) |
| Software | Thermocline for Windows (TCW3) |
| Drive System | Brushless DC motor |
| Temperature Control | Programmable ramping and holding (4–130 °C) |
| Shear Control | Variable rotational speed (up to 160 rpm) |
| Data Output | Time-temperature-viscosity profiles with automated parameter extraction (onset, peak, breakdown, setback, final viscosity) |
| Brand | Perten |
|---|---|
| Origin | Imported |
| Model | RVA 4800 |
| Temperature Range | Up to 140 °C |
| Viscosity Range | 20–50,000 cP (at 80 rpm) |
| Sample Mass | 2–3 g |
| Test Duration | 3 min (stirring value), 13 min (standard starch gelatinization) |
| Compliance | GB/T 22427.7–2023, GB/T 24852–2010, GB/T 24853–2010, AACC 61-02, AACC 22-08, AACC 76-21 |
| Software | TCW3 with 67 pre-validated methods |
| Interface | PC-connected via USB/RS-232 |
| Brand | Perten |
|---|---|
| Origin | Imported (Sweden) |
| Model | RVA-TecMaster |
| Viscosity Range | 40–16,000 cP at 80 rpm |
| Sample Mass | 2–3 g |
| Measurement Time | 3 min (stirring value), 13 min (paste viscosity profile) |
| Compliance | GB/T 22427.7-2023, GB/T 24852-2010, GB/T 24853-2010, AACC 61-02 (1995), AACC 22-08 (1995), AACC 76-21 (1997) |
| Software | Thermocline for Windows (TCW3), supports method upload and offline operation |
