Food Specialized Instruments
Filter
Showing 391–420 of 786 results
| Brand | MakeWave |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | MKX-J2A |
| Price | Upon Request |
| Applicable Standards | GB/T 18006.1–2009, GB/T 27587–2011, SN/T 1891 Series |
| Temperature Accuracy | ±1 °C |
| Brand | Shanda Instruments |
|---|---|
| Model | SD-BQ12T |
| Origin | Shandong, China |
| Instrument Type | Benchtop Integrated Spectrophotometric Analyzer for MDA Quantification in Edible Animal Fats |
| Detection Principle | Colorimetric Assay (Thiobarbituric Acid Reactive Substances, TBARS) |
| Display | 10.1-inch Vertical Touchscreen (Android OS, ARM Cortex-A7 RK3288 Quad-Core @ 1.88 GHz) |
| Optical System | Four-Wavelength Cold Light Source per Channel (410 / 520 / 590 / 630 nm), Patented Optical Path Switching Enabling Up to 64 Wavelengths |
| Detection Channels | ≥12 Simultaneous Channels with Precision Rotating Cuvette Holder |
| Calibration | One-Touch Auto-Calibration with Persistent SP Storage of Light Source Parameters |
| Data Storage | ≥200,000 Records, USB Exportable as Excel Files, Password-Protected Access |
| Connectivity | Dual USB, RJ45 Ethernet, Bluetooth 4.2, 4G APN Module, Wi-Fi |
| Software Expandability | Pre-Configured for 60+ Food Safety Assays |
| Compliance Framework | Designed for Routine Use in GLP-Compliant Food Quality Control Environments |
| Brand | MBS.SRL |
|---|---|
| Origin | Italy |
| Model | MBS(Fitlylab) MBS-MR |
| Function Type | Multi-analyte Quantitative Microbial Detection |
| Sample Types | Solid, Liquid, Surface, Paste, Slurry |
| Wavelengths | Simultaneous Blue-Green-Red (450 nm, 530 nm, 630 nm) |
| Detection Time | 2–10× faster than conventional culture methods |
| Reproducibility | High (CV < 5% across replicate runs) |
| Detection Channels | 8 independent, temperature-controlled wells |
| Sensitivity | 1 CFU per test |
| Specificity | ≥99.999% |
| Compliance | ISO 16140:2003 (validation of alternative microbiological methods), ISO/IEC 17025:2005 (testing laboratory competence), ISO/TR 13843:2000 (water microbiology) |
| Brand | MBS.SRL |
|---|---|
| Origin | Italy |
| Model | MBS(Fitlylab) |
| Detection Channels | 8 |
| Wavelengths | Triple-wavelength (Blue, Green, Red) |
| Detection Time | 2–10× faster than conventional plate culture methods |
| Repeatability | High |
| Sample Types | Solid, liquid, surface swabs, pastes, slurries |
| Regulatory Compliance | ISO 16140:2003 (validation of alternative microbiological methods), ISO/IEC 17025:2005 (general requirements for competence of testing and calibration laboratories), ISO/TR 13843:2000 (water quality — validation of microbiological methods) |
| Brand | AQUALAB |
|---|---|
| Origin | USA |
| Model | AquaLab TDL 2 |
| Measurement Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) at H₂O-specific isotopic absorption line (1368.59 nm) |
| Range | 0.0000–1.0000 aw |
| Resolution | 0.0001 aw |
| Accuracy | ±0.005 aw @ 25 °C |
| Repeatability | ±0.001 aw |
| Temperature Control Range | 15–50 °C |
| Temp. Accuracy | ±0.1 °C |
| Measurement Time | ≤5 min (standard), 1 min (optional rapid mode) |
| Operating Environment | 0–90% RH non-condensing, 4–50 °C ambient |
| Interface | RS-232 & USB |
| Compliance | USP <922>, AOAC Official Method 2014.01, ISO 21807:2022, ASTM F1980-22 |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Model | 892 |
| Heating Range | 50–220 °C (0.1 °C resolution) |
| Sample Capacity | 8 independent reaction vessels |
| Air Flow Control | 1–25 L/h (integrated diaphragm pump, calibrated at 25 °C/1013 hPa) |
| Conductivity Measurement Range | 0–400 µS/cm |
| Temperature Uniformity | <0.3 °C between vessels |
| Temperature Stability | <0.1 °C at setpoint |
| Data Acquisition Interval | 12 s |
| Interface | USB-controlled, PC-based operation |
| Compliance | Fully compliant with FDA 21 CFR Part 11 (via StabNet™ client-server architecture), GLP/GMP-ready audit trail and user role management |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer | Metrohm AG |
| Country of Origin | Imported |
| Model | 892 |
| Pricing | Upon Request |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Easy Na |
| Pricing | Upon Request |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | Easy Na |
| Type | Ion-Selective Electrode (ISE) Analyzer for Sodium (Na⁺) |
| Measurement Principle | Standard Addition Method with Solid-State Sodium ISE |
| Compliance | Designed to support compliance with GB 28050–2011, FDA 21 CFR Part 11 (when used with validated EasyDirect™ configuration), ISO/IEC 17025 laboratory practices |
| Software | EasyDirect™ Data Acquisition Software |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | Migration Cell |
| Quotation | Available Upon Request |
| Single-Side Contact Area | 0.05–2.0 dm² |
| Double-Side Contact Area | 0.1–4.0 dm² |
| Volume | 10–200 mL |
| Brand | MIKROLAB |
|---|---|
| Origin | Denmark |
| Model | OXIPRES |
| Sample Capacity | 100 mL (with ≥5 g fat) |
| Operating Pressure | up to 10 bar (1 MPa) |
| Temperature Range | 30–150 °C |
| Heating Block Max Temp | 150 °C |
| Pressure Sensing | Electronic transducer |
| Output Signal | 1 V FS or 5 V FS |
| Dimensions (2/4/6-sample configurations) | 41 × 30 / 62 × 30 / 83 × 30 cm |
| Footprint | ~600 mm (excl. PC) |
| Power Supply | 230 V / 50 Hz, max. 8 A |
| Software | PARALOG v3 |
| Gas Charging Station | Dual- or hexa-port with safety valve |
| Sample Vessel | 125 mL borosilicate glass jar with sealing lid and O-ring |
| Brand | Astori |
|---|---|
| Origin | Italy |
| Model | CryoTouch 1 |
| Display | 7-inch full-color touchscreen |
| Sample Volume | 2–2.5 mL |
| Analysis Time | ~2 min |
| Preheating Time | ~5 min |
| Temperature Range (Ambient) | +5°C to +36°C |
| Resolution | ±0.0005 °C |
| Repeatability (Raw Milk) | ±0.0025 °C |
| Output Units | °C, °H, % Water |
| Data Storage Capacity | >4,000 results |
| Interface | USB, RS-232 |
| Optional | EP-50 thermal printer |
| Dimensions (W×D×H) | 29 × 44 × 33 cm |
| Weight | ~13 kg |
| Power Supply | 220 V / 50 Hz / 150 W |
| Compliance | IDF-ISO 5764:2009, AFNOR, GB 5413.38–2010 |
| Certification | Verified by China National Institute of Metrology |
| Brand | Mocon |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ProSpect TS/TD-30 |
| Price Range | USD 70,000 – 140,000 (FOB) |
| Application | Real-time milk composition analysis |
| Automation Level | Fully Automatic |
| Analysis Time | 20–30 seconds per measurement |
| Spectral Range | 850–1100 nm |
| Repeatability | ±0.5–2 mm (pathlength-dependent optical consistency) |
| Accuracy | ±35–50 µm (wavelength calibration stability) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | MS2100 |
| Pricing | Upon Request |
| Measurement Range (aw) | 0.000–1.000 aw |
| Accuracy | ±0.015 aw |
| Repeatability | ±0.005 aw |
| Resolution | 0.001 aw |
| Moisture Content Range | 0–100% w/w |
| Moisture Accuracy | ±2% abs |
| Moisture Repeatability | ±0.5% abs |
| Moisture Resolution | 0.1% |
| Sample Temperature Range | −40 to +85 °C |
| Power Supply | Internal rechargeable battery (4 h continuous operation |
| Intrinsic Safety Rating | Ia, Class 1, Groups A/B/C/D |
| Communication Interface | RS-232 & RS-485 dual-port |
| Data Storage | 100 sample records with timestamp, auto/manual logging |
| Calibration Options | Saturated salt solutions (ERH method) or certified reference standards |
| Sensor Principle | Capacitive polymer humidity sensor with integrated temperature compensation |
| Data Retention | Non-volatile memory (2 MB), retains all settings and logs after power loss |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | N-4L |
| Price Range | USD 150–2,500 (FOB Yokohama) |
| Test Target | Somatic Cell Count (SCC) & Electrical Conductivity (EC) Correlates for Subclinical Mastitis |
| Automation Level | Semi-Automatic |
| Analysis Time | ≤3 seconds per quarter |
| Detection Principle | Dual-Parameter Impedance Spectroscopy & Conductivity Ratio Analysis |
| Repeatability | CV ≤3.2% (n=20, pooled quarter milk samples) |
| Accuracy | ±0.1 unit in normalized conductivity ratio (dimensionless index) |
| Brand | NCS |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | NX-300 |
| Function Type | Multi-analyte (Cd, Pb, As, Hg, Cr, etc.) |
| Sample Type Compatibility | Solid food matrices (rice, grains, flour, spices, infant formula, dried vegetables) |
| Detection Time | ≤3 min for screening |
| Power Supply | 220 VAC ±10%, 50/60 Hz, 1.5 A |
| Dimensions | 550 W × 330 D × 440 H mm |
| Weight | 30 kg |
| X-ray Source | Air-cooled microfocus X-ray tube |
| Detector | Fast Silicon Drift Detector (FastSDD) |
| Optical Path | Non-destructive, optimized beam collimation and scatter suppression architecture |
| Radiation Safety | Compliant with GBZ 115–2002 “Hygienic Protection Standard for X-ray Diffraction and Fluorescence Analyzers” |
| Brand | NCS (China Iron and Steel Research Institute Group) |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Yes |
| Country of Origin | China |
| Model | NX-300FA |
| Pricing | Upon Request |
| Detection Principle | Energy-Dispersive X-ray Fluorescence (EDXRF) |
| Sample Throughput | Up to 84 samples unattended |
| Analysis Time | 3 min (Cd screening), 10 min (Cd quantification), 6 min (multi-element screening), 20 min (multi-element quantification) |
| Detection Limits | Cd ≤ 0.038 mg/kg, Se ≤ 0.048 mg/kg |
| Linear Range | Cd 0.038–2.6 mg/kg, Se 0.048–2.0 mg/kg |
| Precision (RSD) | Cd ≤ 5%, Se ≤ 10% |
| Reproducibility | Absolute difference between two independent measurements ≤ 20% of mean |
| Radiation Safety | Compliant with GBZ 115–2002 (Chinese national standard for radiation protection of XRF instruments) |
| Sample Form | Direct analysis of powdered or granular cereal grains and processed food matrices |
| Elements Supported | Cd, Pb, As, Cr, Hg, Se |
| Regulatory Alignment | Designed for compliance with GB 2762–2022 (Chinese National Standard for Contaminants in Foods), aligned with ISO 13253:2012 (EDXRF for metals in food), and supports audit-ready data handling per GLP/GMP principles |
| Brand | Neo |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MILKYWAY-S |
| Detection Parameters | Fat (0.5–12.00%), Non-Fat Solids (6.00–12.00%), Density (1.0260–1.0330 g/cm³), Protein (2.00–6.00%), Freezing Point (0.000–1.000 °C), Water Adulteration (0–60.00%), Lactose (1.5–7.0%), Ash (0–30%), Temperature (1–40 °C) |
| Analysis Time | 60–90 seconds |
| Repeatability | < 0.5% CV |
| Accuracy | Fat ±0.1%, Protein ±0.2%, Lactose ±0.15% |
| Automation Level | Semi-Automatic |
| Application Category | Food & Dairy Quality Control Instruments |
| Brand | Niklas |
|---|---|
| Origin | Germany |
| Model | W.N. 14 |
| Coating Capacity | 2–14 t/h |
| Liquid Dosing Range | 0.3–2.6 mL/kg, 0.9–4.2 mL/kg, 2.7–6.3 mL/kg, 3.7–8.6 mL/kg |
| Dual-Liquid Capability | Yes |
| Compliance | JKI Federal Research Centre Certified |
| Construction | Stainless Steel Mixing Drum with Nylon-Brush Auger |
| Dosing Principle | Patented Niklas Metering System (Mechanical Seed Roller + Precision Liquid Metering Wheel) |
| Liquid Delivery | Centrifugal Pump with Overflow-Regulated Metering Trough and Recirculation Loop |
| Optional Features | Dust Extraction Unit, Cross-Flow Sieve, Compressed Air Interface (for Pneumatic Actuation), Dual-Bagging Nozzle Adapter (DN 150 mm) |
| Brand | Niklas |
|---|---|
| Origin | Germany |
| Model | W.N.5/100 |
| Batch Capacity | 35–140 L |
| Throughput | 16 t/h |
| Control System | Integrated PLC with Weight & Time-Based Dosing |
| Liquid Delivery | Precision Metering Pumps with 20 L Load Cell System |
| Spray Nozzle | Fine Mist Dispenser at Parabolic Seed Flow Core |
| Compliance | Designed for ISO 9001-aligned seed treatment workflows and compatible with EU Plant Protection Product (PPP) Regulation (EC) No 1107/2009 application protocols |
| Brand | Niklas |
|---|---|
| Origin | Germany |
| Model | W.N.5/200 |
| Batch Capacity | 75–270 L |
| Throughput | 30 t/h |
| Control System | Integrated PLC with Weight & Time-Based Dosing |
| Liquid Dosing | Precision Metering Pumps + 20 L Weighing System |
| Powder Dosing | Synchronized Volumetric Feeders |
| Spray Nozzle | Fine-Mist Parabolic Distribution System |
| Compliance | Designed for ISO 9001-aligned seed treatment facilities, compatible with GLP/GMP documentation workflows |
| Brand | Niklas |
|---|---|
| Origin | Germany |
| Model | W.N.5/50 |
| Batch Capacity | 25–70 L |
| Throughput | 9 t/h |
| Control System | Integrated PLC with Weight- and Time-Based Dosing |
| Liquid Dosing | Precision Metering Pump with 20 L Weighing System |
| Powder Dosing | Synchronized Volumetric Feeder |
| Spray Nozzle | Fine-Mist Atomizer Positioned at Parabolic Seed Trajectory Center |
| Compliance | Designed for ISO 22000-aligned food-grade seed processing environments |
| Software | Recipe-Driven Batch Management with Storage for Multiple Seed Types and Formulations |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Model | NMI20 |
| Magnet Type | Permanent Magnet |
| Field Strength | 0.5 ± 0.08 T |
| Probe Coil Diameter | 15 mm / 40 mm |
| Measurement Capabilities | Water Phase Quantification, T₁/T₂/T₂* Relaxometry, Proton Density & Weighted Imaging, Spatial Water Distribution Mapping |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | NMI20 Series+ |
| Pricing | Upon Request |
| Brand | NIUMAG |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | NMI20-015V-I |
| Pricing | Upon Request |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NMI20-060 |
| Pricing | Upon Request |
| Magnetic Field Strength | 0.50 ± 0.03 T |
| Magnet Homogeneity | ≤20 ppm |
| Magnet Orientation | Horizontal & Vertical |
| Maximum Sample Dimensions | Ø60 mm × H60 mm |
| Measurable Parameters | T₁ & T₂ relaxation times, spatial water/oil distribution, bound/free water ratio, moisture content (2–10 wt%), oil content (1–100 wt%) |
| Optional Modules | Temperature-controlled stage, humidity chamber, microwave coupling unit, vacuum freeze-drying interface |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | NMI20-060-H |
| Pricing | Available Upon Request |
| Magnetic Field Strength | 0.50 ± 0.03 T |
| Magnet Homogeneity | ≤20 ppm |
| Magnet Orientation | Horizontal & Vertical Configurable |
| Max Sample Dimensions | Ø60 mm × H60 mm |
| Measurable Parameters | T₁/T₂ Relaxation Times, Spatial Water Distribution, Bound/Free Water Ratio, Oil/Water Content (Oil: 1–100% |
| Water | 2–10%) |
| Optional Modules | Temperature Control Unit, Humidity Chamber, Microwave Irradiation Module, Vacuum Freeze-Drying Coupling Kit |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NMI20-060H-I |
| Pricing | Available Upon Request |
| Brand | NIUMAG |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PQ001 |
| Pricing | Available Upon Request |
| Magnet Type | Permanent Magnet |
| Magnetic Field Strength | 0.5 ± 0.08 T |
| Larmor Frequency | 21.3 MHz |
| Probe Coil Diameter | 25 mm |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PQ001-20 |
| Quotation | Upon Request |
| Magnet Type | Permanent Magnet |
| Magnetic Field Strength | 0.5 ± 0.08 T |
| Probe Coil Diameter | 25 mm |
| Effective Sample Volume | Ø25.4 mm × H35 mm |
| Dimensions (L×W×H) | 1685 mm × 520 mm × 386 mm |
| Weight | ~120 kg |