Gas Detector
Filter
Showing 2881–2910 of 2968 results
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | XP-308II |
| Price | Available Upon Request |
| Detection Gas | Formaldehyde (HCHO) |
| Detection Principle | Potentiostatic Electrolytic Sensor |
| Measurement Range (Standard) | 0.00–3.00 ppm |
| Minimum Resolution | 0.01 ppm |
| Sampling Method | Integrated Micro-Pump (Active Draw) |
| Display | Dual-mode — Digital Numeric + Analog Bar Graph |
| Power Supply | Six AA Alkaline Batteries or Optional DC Adapter |
| Battery Life | Approx. 100 Measurements per Set |
| Filter Lifetime | Approx. 100 Measurements (DNPH Cartridge) |
| Operating Temperature | 0 °C to +40 °C |
| Dimensions (W×H×D) | 175 × 140 × 86 mm |
| Weight | 2.5 kg |
| Standard Accessories | 5 × DNPH Filters, 6 × AA Batteries, Leather Carrying Case, Sampling Tube, 10 × Replacement Filter Discs, Stainless Steel Tweezers |
| Optional Accessories | DC Power Adapter, Data Export Software, RS-232 Communication Cable |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | XP-3180 |
| Pricing | Upon Request |
| Origin | Japan |
|---|---|
| Type | Portable Gas Detector |
| Target Gas | O₂ in Combustion Exhaust |
| Response Time | ≤45 s |
| Accuracy | ±0.3 vol% (per JIS T 8201) |
| Measurement Range | 0–25.0 vol% |
| Intrinsic Safety Rating | Ex ib IIB T3 |
| Power | 4× AA alkaline batteries (≈100 h operation, no backlight/no alarm) |
| Dimensions | 82 × 162 × 36 mm |
| Weight | ≈450 g (battery-free) |
| Detection Principle | Membrane-type Galvanic Cell |
| Display | Backlit LCD with dual numeric + bar-graph readout |
| Alarm | Audible buzzer + flashing red LED (configurable threshold, default 18.0 vol%) |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | XP-329F |
| Pricing | Available Upon Request |
| Detection Principle | High-Sensitivity Indium Oxide-Based Heated Semiconductor Sensor |
|---|---|
| Display | 64×128 Dot-Matrix LCD |
| Measurement Modes | Real-Time Monitoring / Batch Sampling |
| Odor Intensity Range | 0–40 (Odor Unit Scale) |
| Odor Level Range | 0–2000 (Arbitrary Unit Scale) |
| Data Storage Capacity | Up to 8,188 points (Monitoring Mode), Up to 4,095 points (Batch Mode) |
| Operating Environment | 0°C–40°C, 30–80% RH |
| Power Supply | 4 × AA Alkaline Batteries (≈8 h operation) or Optional AC Adapter |
| Dimensions & Weight | 84 × 275 × 40 mm, ≈640 g (incl. batteries) |
| Analog Output | 0–200 mV DC (scalable to either 0–2000 or 0–40 scale) |
| Communication Interface | RS-232C with Dedicated PC Software |
| Accessories Included | Activated Carbon Filter, Exhaust Filter, Suction Kit, Metal Cap for Tubing, AC Adapter, Carrying Case, Connectorized Output Cable, Odor Analysis Software Suite, 4 × AA Batteries, 1 × PTFE Sampling Tube, 20 × Filter Cloths, 2 × Activated Carbon Packs |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | XP-329m |
| Pricing | Available Upon Request |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | XQC-15E |
| Pricing | Available Upon Request |
| Brand | Qingdao Xinye Environmental Protection Co., Ltd. |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | XY-HCS5 |
| Price | USD 13,800 (FOB Qingdao) |
| Rain Sensor Sensitivity | ≥0.03 mm/min |
| Lid Opening Time | ≤30 s |
| Lid Closing Time | ≤5 min |
| Maximum Rainfall Intensity Range | 0.03–4 mm/min |
| Measurement Accuracy | ±0.4 mm (at rainfall intensity ≤4 mm/min) |
| Funnel Diameter | 400 mm |
| Dustfall Cylinder Diameter | 150 mm |
| pH Range (25°C) | 1.0–10.0 |
| pH Accuracy | ±0.1 pH |
| Conductivity Range (25°C) | 0–50 mS/m |
| Conductivity Accuracy | ±2% FS |
| Sample Refrigeration | 4±1°C |
| Data Storage Capacity | 8,000 precipitation events (10-year retention) |
| Power Consumption | Max 100 W (25 W standby) |
| Brand | Yamatronics |
|---|---|
| Origin | Japan |
| Model | KH-3000-01A |
| Instrument Type | Aerosol Particle Counter for Pollen Detection |
| Measurement Principle | Forward + Sideways Semiconductor Laser Light Scattering |
| Particle Size Range | ~25–40 µm |
| Flow Rate | 4.1 LPM |
| Measurement Interval | 1–9999 min (adjustable) |
| Display | LCD |
| Interface | RS-232C |
| Data Storage Capacity | 180 records |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions | 320(W) × 230(D) × 140(H) mm |
| Weight | ~5 kg |
| Compliance | Designed for ambient airborne pollen surveillance in accordance with ISO 21501-4 and JIS Z 8901 Annex B for optical particle counting |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | YESAIR |
| Price | USD 11,500 (approx.) |
| Instrument Type | Portable |
| Detection Targets | Multi-component Gases (CO₂, CO, VOCs, Toxic Gases, Particulates) |
| Channels | 8 Independent Sensor Inputs |
| Display | Backlit Multiline Alphanumeric LCD |
| Data Storage | >1,000,000 Points on Removable SD Card (Optional) |
| Power | Rechargeable NiMH Battery (24 h typical runtime) |
| Enclosure | UL94-V0 Compliant ABS Housing |
| Dimensions | 254 × 89 × 178 mm |
| Weight | 1.7 kg |
| Sampling | Integrated Automatic Pump (Active Sampling Mode) |
| Connectivity | Micro-USB for Configuration & Data Export |
| Alarm | Programmable Thresholds with Internal 80 dB Buzzer |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | 2030B |
| Pricing | Available Upon Request |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | GFC-5B |
| Pricing | Available Upon Request |
| Flow Range | 1.0–5.0 L/min |
| Load Capacity | ≥5.0 L/min at 1000 Pa backpressure |
| Flow Stability | ≤5% drift over 8 h |
| Flow Accuracy | ±5% of setpoint |
| Timing Range | 0–24 h 59 min (timing error ≤0.1%) |
| Continuous Operation | ≥8 h |
| Operating Temperature | 0–40 °C |
| Power Supply | 7.4 V Li-ion battery pack |
| Dimensions | 100 × 52 × 152 mm |
| Weight | 500 g |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | QC-4 |
| Pricing | Available Upon Request |
| Load Capacity | ≥2 L/min at 4000 Pa |
| Flow Range | 0.1–1.5 L/min |
| Flow Stability | ≤5% |
| Flow Accuracy | ≤5% |
| Timer Range | 1–99 min |
| Timer Accuracy | <0.1% |
| Operating Temperature | −10 to +45 °C |
| Battery Runtime | ≥5 h (continuous) |
| Dimensions (W×H×D) | 115 × 190 × 60 mm |
| Weight (incl. battery) | 700 g |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | QC-2A |
| Pricing | Available Upon Request |
| Pump Type | High-Torque Diaphragm Vacuum Pump |
| Flow Range | 0.1–1.5 L/min |
| Minimum Flow Rate | ≥1.0 L/min at Load |
| Flow Stability | ≤5% RSD |
| Flow Accuracy | ±5% FS |
| Timer Range | 1–99 min |
| Timer Accuracy | <0.1% |
| Operating Temperature | −10 to +40 °C |
| Battery Runtime | >6 h (continuous) |
| Dimensions (L×W×H) | 210 × 125 × 95 mm |
| Weight (incl. battery) | 2.8 kg |
| Brand | YINHEKEJI |
|---|---|
| Origin | Jiangsu, China |
| Model | AKFC-92A |
| Flow Range | 5–30 L/min |
| Nominal Sampling Flow | 20 L/min |
| Maximum Vacuum Pressure | >3000 Pa |
| Load Capacity | ≥1000 Pa |
| Sampling Duration | 0–99 min (programmable) |
| Continuous Operation Time | >120 min |
| Noise Level | ≤70 dB(A) |
| Explosion Protection | ibI (150 °C) intrinsically safe |
| Operating Temperature | −5 to 35 °C |
| Relative Humidity | ≤95% RH |
| Dimensions | 200 × 140 × 80 mm |
| Weight | 1.8 kg |
| Dust Collection Modes | Total dust & respirable dust (via impactor pre-separator meeting BMRC curve specifications) |
| Brand | YINHEKEJI |
|---|---|
| Origin | Jiangsu, China |
| Model | AKFC-92G |
| Sampling Flow Rate | 2 L/min |
| Maximum Negative Pressure | >5000 Pa |
| Load Capacity | >2000 Pa |
| Dust Collection Range | Total Dust & Respirable Dust (BMRC-curve compliant) |
| Continuous Operation Time | >10 h |
| Explosion Protection Type | Mine-used Intrinsic Safety “iI” |
| Noise Level | <60 dB(A) |
| Operating Temperature | 0–35 °C |
| Relative Humidity | <95% RH |
| Dimensions | 120 × 80 × 42 mm |
| Weight | 450 g |
| Brand | YINHEKEJI |
|---|---|
| Origin | Jiangsu, China |
| Model | CCZ-30 |
| Flow Range | 3–30 L/min (user-configurable) |
| Flow Control | Closed-loop constant-flow regulation |
| Flow Accuracy | ≤±5% FS |
| Flow Stability | ≤3% FS |
| Flow Repeatability | ≤2% |
| Timing Accuracy | ≤±0.1% |
| Timer Range | 1 min – 99 h 59 min |
| Display | 4.3″ HD capacitive touchscreen |
| Data Storage | 100 sampling records |
| Volume Calculation | Automatic in-situ & standard-condition volume conversion |
| Battery Life | >8 h at 5 L/min |
| Load Capacity | ≥2500 Pa at 30 L/min |
| Operating Temperature | −10 to 50 °C |
| Relative Humidity | ≤95% RH |
| Noise Level | <70 dB(A) |
| Explosion Protection | Ex ib IIA T3 Gb |
| Sampling Modes | Time-based, volume-based, cyclic, manual |
| Compliance | Meets 2020 Occupational Health Technical Service Institution Equipment Requirements (China) |
| Brand | YINHEKEJI |
|---|---|
| Origin | Jiangsu, China |
| Model | FCD-50 |
| Flow Ranges | 1–5 L/min, 1–10 L/min, 5–25 L/min, 5–30 L/min |
| Sampling Time | 1 min – 99 h 59 min |
| Max Vacuum | >3000 Pa |
| Noise Level | ≤70 dB(A) |
| Operating Temp. | −20 °C to +40 °C |
| Relative Humidity | ≤85 % RH |
| Dimensions | 210 × 150 × 90 mm |
| Weight | ~1.8 kg |
| Power | Rechargeable LiFePO₄ Battery (DC/AC dual-mode) |
| Intrinsic Safety Rating | Ex ib IIB T4 Gb per GB 3836.4–2010 |
| Compliance | MT 162–1995, Q/320925JYH01–2019 |
| Preseparator Efficiency | Conforms to BMRC respirable dust convention |
| Brand | YINHEKEJI |
|---|---|
| Origin | Jiangsu, China |
| Model | FCD-50 Standard |
| Power Supply | DC 7.4 V / 8800 mAh Li-ion rechargeable battery |
| Adjustable Flow Rates | 1–10 L/min, 5–25 L/min, or 5–30 L/min (user-selectable) |
| Maximum Negative Pressure | >1000 Pa (metal vane pump) |
| Flowmeter Accuracy | ±2.5% F.S. |
| Flow Stability | ≤5% |
| Timing Accuracy | ±0.01% |
| Operating Noise | <75 dB(A) |
| Ambient Temperature Range | −10 °C to +40 °C |
| Relative Humidity | <95% RH |
| Charging Current | 1000 mA |
| Continuous Operation Time | >8 h |
| Dimensions (L×W×H) | 220 × 135 × 150 mm |
| Weight | 3.5 kg |
| Sampling Modes | Total dust (standard), respirable dust (optional) |
| Display | LCD with menu-driven interface |
| Timer Functions | Programmable start/stop, pause/resume, real-time elapsed time, end-of-sampling alert |
| Brand | YINHEKEJI |
|---|---|
| Origin | Jiangsu, China |
| Model | FCG-5 |
| Instrument Type | Handheld Air Sampling Pump |
| Sampling Configuration | Single-Channel |
| Flow Ranges | (50–500) mL/min |
| Maximum Vacuum Pressure | >35 kPa |
| Flow Stability | ≤±5% over 1 h |
| Flowmeter Accuracy | <±2.5% FS |
| Service Life at Max Flow & Load | >5000 h |
| Continuous Operation at Max Flow & Load | >12 h |
| Ingress Protection | IP54 (dust- and splash-resistant) |
| Explosion Protection | Ex ib IIB T3 Gb (IEC 60079-0, -11) |
| Power Supply | Rechargeable Li-ion battery, 7.4 V / 2.3 Ah |
| Operating Temperature | −10 °C to +40 °C |
| Storage Temperature | −40 °C to +60 °C |
| Ambient Pressure Range | 80–110 kPa |
| Relative Humidity | ≤95% RH (non-condensing) |
| Acoustic Noise | ≤50 dB(A) |
| Weight | ≈0.5 kg |
| Timer Range | 1 min to 99 h 59 min |
| Timer Accuracy | ≤0.1% |
| Anti-Suction System | Integrated liquid/ particulate backflow prevention |
| Battery Runtime (typical) | ≥12 h (at mid-range flow, ambient conditions) |
| Charging Time | 4–6 h (via dedicated charger, 220 V AC input) |
| Brand | YINHEKEJI |
|---|---|
| Origin | Jiangsu, China |
| Model | FCG-5H |
| Instrument Type | Single-Channel Intrinsically Safe Air Sampler |
| Volumetric Flow Ranges | (10–300) mL/min |
| Maximum Vacuum Pressure | >35 kPa |
| Flow Stability | ≤±5% over 1 h |
| Flow Meter Accuracy | ≥±2.5% of reading |
| Service Life at Max Flow & Load | ≥5000 h |
| Continuous Operation at Max Flow & Load | ≥12 h with flow deviation ≤±5% |
| Explosion Protection | Ex ib IIB T3 Gb |
| Operating Temperature | −10 °C to +50 °C |
| Dimensions | 110 × 105 × 55 mm |
| Weight | ≤0.4 kg |
| Timer Range | 1 min – 99 h 59 min |
| Timer Accuracy | ≤±0.1% |
| Data Storage Capacity | 100 sampling records |
| Display | Backlit LCD with real-time flow, cumulative volume, ambient temperature, barometric pressure, and battery status |
| Brand | YINHEKEJI |
|---|---|
| Origin | Jiangsu, China |
| Model | FCS-30 |
| Sampling Flow Options | 1–10 L/min, 5–25 L/min, or 5–30 L/min |
| Fixed Flow Settings | 5 L/min and 20 L/min |
| Maximum Vacuum Pressure | >3000 Pa |
| Timing Range | 0–99 h 59 min (programmable) |
| Continuous Operation Time | >180 min (typical) |
| Battery | Built-in high-energy LiFePO₄ rechargeable pack |
| Noise Level | <60 dB(A) |
| Operating Temperature | −5 °C to +40 °C |
| Storage Temperature | −40 °C to +60 °C |
| Atmospheric Pressure Range | 80–110 kPa |
| Relative Humidity | ≤95% RH |
| Ingress Protection | IP54 (typical for field-deployable samplers) |
| Explosion Protection | Ex ib IIB T3 Gb per GB 3836.4–2010 / IEC 60079-11 |
| Weight | ~2.0 kg |
| Dust Separation | Dual-stage pre-selector compliant with BMRC respirable dust convention (ISO 7708:1995 & EN 481:1993) |
| Standards Compliance | MT 162–1995, Q/320925JYH01–2019, GB 3836.1–2010 & GB 3836.4–2010 |
| Brand | YINHEKEJI |
|---|---|
| Origin | Jiangsu, China |
| Model | FCS-30 Non-Explosion-Proof |
| Operating Voltage | DC 11.1 V / 4500 mAh (diaphragm pump) or DC 7.4 V / 4500 mAh (rotary vane pump) |
| Flow Range | 3–30 L/min, 5–30 L/min, or 15–40 L/min (user-selectable) |
| Vacuum Pressure | >2500 Pa |
| Flow Accuracy | ±2.5% FS |
| Flow Stability & Error | ≤±5% |
| Timing Range | 1 min – 99 h 59 min |
| Timing Accuracy | ≤±0.1% |
| Operating Temperature | −10°C to 40°C |
| Relative Humidity | <95% RH |
| Noise Level | <75 dB(A) |
| Dimensions | 205 × 135 × 115 mm |
| Weight | 2.5 kg |
| Sampling Modes | Total dust (standard), respirable dust (optional) |
| Brand | YINHEKEJI |
|---|---|
| Origin | Jiangsu, China |
| Model | JFC-3 |
| Sampling Flow Range | 0.1–3 L/min |
| Maximum Vacuum Pressure | >26 kPa (≥200 mmHg) |
| Flow Accuracy | ≤±2.5% FS |
| Flow Stability | <5% over 8 h |
| Timer Accuracy | ≤±0.1% |
| Operating Temperature | 0–50 °C |
| Power Supply | AC 220 V ±10%, 50 Hz / DC 7.4 V Li-ion rechargeable battery |
| Weight | ≤0.5 kg |
| Dimensions | 137 × 88 × 45 mm |
| Battery Runtime | ≥10 h (continuous or intermittent operation) |
| Brand | YINHEKEJI |
|---|---|
| Origin | Jiangsu, China |
| Model | QCD-1000/1500/3000 |
| Sampling Channel | Single |
| Flow Range | 0.1–1.0 L/min (QCD-1000) |
| Maximum Vacuum Pressure | >35 kPa |
| Flow Stability | ≤5% |
| Flowmeter Accuracy | ±2.5% FS |
| Flow Error at Load | ≤±5% |
| Load Capacity | ≥1.0 L/min at 4.5 kPa backpressure |
| Battery | 7.4 V / 2200 mAh Li-ion |
| Operating Temperature | −10 °C to +40 °C |
| Continuous Operation Time | ≥12 h |
| Weight | ≤0.5 kg |
| Timing Range | 1 min to 99 h 59 min |
| Timing Accuracy | ≤±0.1% |
| Service Life at Max Load | >5000 h |
| Runtime at Max Flow & Max Backpressure | 8–10 h |
| Brand | YINHEKEJI |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | QCD-5 |
| Price Range | USD 140 – 280 |
| Flow Range | 1.0–5.0 L/min |
| Load Capacity | ≥5.0 L/min at 1000 Pa negative pressure |
| Flow Accuracy | ≤±5% |
| Flow Stability | ≤5% |
| Timer Range | 1 min – 99 h 59 min |
| Timer Accuracy | ≤±0.1% |
| Operating Temperature | −10°C to +40°C |
| Ambient Temperature Range | −25°C to +45°C |
| Continuous Operation Time | >8 h |
| Power Supply | Built-in 7.4 V rechargeable Li-ion battery pack |
| Weight | ≤0.7 kg |
| Dimensions | 100 × 50 × 110 mm |
| Brand | YINHEKEJI |
|---|---|
| Origin | Jiangsu, China |
| Model | QCS-3000 Standard |
| Instrument Type | Dual-Channel Passive/Active Air Sampler |
| Flow Ranges | 20–500 mL/min |
| Maximum Vacuum Pressure | >35 kPa |
| Flow Stability | ≤±5% over 1 h |
| Flowmeter Accuracy | ≤±2.5% FS |
| Operating Life at Max Flow & Backpressure | >5000 h |
| Continuous Runtime at Max Flow & Rated Resistance | >12 h |
| Power Supply | DC 7.4 V / 4500 mAh Li-ion battery or AC 220 V ±10%, 50 Hz |
| Timing Range | 1 min – 99 h 59 min |
| Timing Accuracy | ≤±0.1% |
| Noise Level | <60 dB(A) |
| Operating Temperature | −10 °C to +40 °C |
| Relative Humidity | <95% RH |
| Dimensions | 205 × 135 × 115 mm |
| Weight | 1.8 kg |
| Brand | YINHEKEJI |
|---|---|
| Origin | Jiangsu, China |
| Model | QCS-3000 |
| Instrument Type | Dual-Channel Gas Sampler |
| Flow Range | 0.1–3.0 L/min |
| Maximum Vacuum Pressure | ≥35 kPa |
| Flow Stability | ±5% |
| Flowmeter Accuracy | ±2.5% |
| Rated Service Life at Max Flow & Load | 20,000 h |
| Operating Pressure Drop at Max Flow | 4.5 kPa |
| Battery | LiFePO₄ (Lithium Iron Phosphate) |
| Dimensions | 220 × 150 × 80 mm |
| Weight | 1.6 kg |
| Ambient Operating Temperature | −10 to +40 °C |
| Relative Humidity Limit | ≤85% RH |
| Noise Level | ≤60 dB(A) |
| Explosion Protection | Ex ib IIB T3 Gb (IEC/EN 60079-0, -11) |
| Compliance | MT162-1995, Q/320925JYH05-2019, GB 3836.4-2010 |
| Brand | YINHEKEJI |
|---|---|
| Origin | Jiangsu, China |
| Model | QCS-3000A |
| Flow Range | 0–2.0 L/min (adjustable in multiple ranges: 10–300, 20–500, 50–500, 100–1000, 100–1500, 100–2000, 50–1200 mL/min) |
| Flow Resolution | 1 mL/min |
| Flow Accuracy | ≤ ±2.5% |
| Flow Stability | ≤ 5% |
| Flow Reproducibility | ≤ 2% |
| Maximum Backpressure Capability | ≥ 35,000 Pa |
| Operating Time at Max Flow & Max Resistance | ≥ 12 h (flow drift ≤ 5%) |
| Battery Runtime | ≥ 20 h (typical use) |
| Display | 7-inch resistive color touchscreen |
| Data Storage | 200 sampling records with timestamp, flow profile, volumetric calculation (actual & standard conditions), temperature, pressure, battery level |
| Sampling Modes | Timed, cyclic, intermittent, manual, delayed start |
| Environmental Operating Range | –10 to +50 °C |
| Dimensions | 200 × 125 × 105 mm |
| Weight | 1.4 kg |
| Compliance | GB 50325–2020, JJG 956–2013, HJ 194–2017, GB/T 18883–2022 |
| Brand | YINHEKEJI |
|---|---|
| Origin | Jiangsu, China |
| Model | QCS-6000 |
| Instrument Type | Multi-Channel Gas Sampler |
| Flow Ranges | (20–500) mL/min |
| Maximum Vacuum Pressure | >35 kPa |
| Flow Stability | ≤±5% over 1 h |
| Flowmeter Accuracy | <±2.5% FS |
| Operational Lifetime at Max Flow & Backpressure | >5000 h |
| Continuous Runtime at Max Flow & Backpressure | >12 h |
| Power Supply | DC 7.4 V (dual 4.5 Ah Li-ion battery packs) / AC 220 V ±10%, 50 Hz |
| Timing Range | 1 min – 99 h 59 min |
| Timing Accuracy | ≤±0.1% |
| Noise Level | ≤65 dB(A) |
| Operating Temperature | −10 °C to +40 °C |
| Relative Humidity | <95% RH |
| Dimensions | 265 × 135 × 175 mm |
| Weight | 2.5 kg |
