- All
- Favorite
- Popular
- Most rated
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | YQ-300Q |
| Filtration Efficiency Range | 0–99.999% |
| Aerosol Flow Rate | 10–100 L/min (Accuracy Class 2.5) |
| Sampling Frequency | 1–9999 cycles/min (adjustable) |
| Aerosol Concentration | 20–30 mg/m³ |
| Count Median Diameter (CMD) | NaCl aerosol (0.075 ± 0.02) µm |
| Geometric Standard Deviation (GSD) | NaCl ≤1.86 |
| Dynamic Concentration Range | 0.001–100 mg/m³ (±1% accuracy) |
| Differential Pressure Sensor Range | 0–500 Pa |
| Dimensions | 460 mm × 525 mm × 1430 mm |
| Power Supply | AC 220 V, 50 Hz |
| Environmental Operating Conditions | 25 °C ± 5 °C, 30 %RH ± 10 %RH |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Region Classification | Domestic (China) |
| Model | YQ-300W |
| Quotation | Upon Request |
| Filtration Efficiency Range | 0–99.999% |
| Flow Rate Range | 10–100 L/min (Accuracy Class 2.5) |
| Sampling Frequency | 1–9999 times/min (Adjustable) |
| Test Aerosol Concentration | 20–30 mg/m³ |
| Count Median Diameter (CMD) | NaCl aerosol (0.075 ± 0.02) µm |
| Geometric Standard Deviation (GSD) | NaCl ≤ 1.86 |
| Dynamic Concentration Detection Range | 0.001–100 mg/m³ (Accuracy: ±1%) |
| Instrument Accuracy Class | Class 4 |
| Dimensions | 460 mm × 525 mm × 1430 mm |
| Differential Pressure Sensor Range | 0–500 Pa |
| Power Supply | AC 220 V, 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Region | Domestic (China) |
| Model | GB-KF30010 |
| Pricing | Upon Request |
| Filtration Efficiency Range | 0–99.999% |
| Flow Rate Range | 10–100 L/min (Accuracy Class 2.5) |
| Sampling Frequency | 1–9999 cycles/min (adjustable) |
| Test Aerosol Concentration | 20–30 mg/m³ |
| Count Median Diameter (CMD) | NaCl aerosol (0.075 ± 0.02) µm |
| Geometric Standard Deviation (GSD) | NaCl ≤ 1.86 |
| Dynamic Concentration Range | 0.001–100 mg/m³ (±1% accuracy) |
| Differential Pressure Sensor Range | 0–500 Pa |
| Dimensions | 460 mm × 525 mm × 1430 mm |
| Power Supply | AC 220 V, 50 Hz |
| Environmental Control | Integrated temperature & humidity sensor (operating range: 25 °C ± 5 °C, 30 %RH ± 10 %RH) |
| Brand | GBPI (Guangzhou Biaoji) |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | GB-XF1000 |
| Sampling Flow Rate (A/B) | 28.3 L/min ±2.5% |
| Aerosol Generation Flow Rate | (8–10) L/min ±2.5% |
| Peristaltic Pump Flow Range | (0.006–3.0) mL/min ±2.5% |
| Pressure Measurement Accuracy | ±2.5% (except aerosol chamber vacuum: ±2.0%) |
| Aerosol Particle Size | MMAD = 3.0 ± 0.3 µm, GSD ≤ 1.5 |
| Andersen Cascade Impactor Stages | 6-stage (I: >7 µm |
| II | 4.7–7 µm |
| III | 3.3–4.7 µm |
| IV | 2.1–3.3 µm |
| V | 1.1–2.1 µm |
| VI | 0.6–1.1 µm) |
| Aerosol Chamber Dimensions | 60 cm (L) × 8.5 cm (Ø) × 3 cm (T) |
| Cabinet Vacuum Range | −50 to −200 Pa |
| Aerosol Chamber Vacuum | −90 to −120 Pa |
| HEPA Filter Efficiency | ≥99.99% for particles ≥0.3 µm |
| Data Storage Capacity | >100,000 test records |
| Display | 10.4″ industrial-grade capacitive touchscreen |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Power Consumption | <1500 W |
| Noise Level | <65 dB(A) |
| Net Weight | ~150 kg |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | YQ-300 |
| Price | Upon Request |
| Filtration Efficiency Range | 0–99.999% |
| Flow Rate Range | 10–100 L/min (Accuracy Class 2.5) |
| Sampling Frequency | 1–9999 times/min (adjustable) |
| Aerosol Concentration | 20–30 mg/m³ |
| Count Median Diameter (CMD) | NaCl aerosol (0.075 ± 0.02) µm |
| Geometric Standard Deviation (GSD) | NaCl ≤ 1.86 |
| Dynamic Detection Range | 0.001–100 mg/m³ (Accuracy: ±1%) |
| Differential Pressure Sensor Range | 0–500 Pa |
| Dimensions | 460 mm × 525 mm × 1430 mm |
| Power Supply | AC 220 V, 50 Hz |
| Environmental Requirements | 25 °C ± 5 °C, 30 %RH ± 10 %RH |